Jaipur
+918529833535

'orr'

Items tagged with 'orr'

product image
Clinical Chemistry

ADVIA Chemistry XPT System An advanced, automated clinical chemistry analyzer for high-volume laboratories The ADVIA® Chemistry XPT System provides timely, reliable results with continuous operation to meet the chemistry workloads of the most demanding laboratories. Delivers high throughput of up to 2400 tests per hour. Manages comprehensive testing with a menu of more than 115 assays. Improves workflow using automation and system technologies such as micro-volume and aliquot retention. Features & Benefits The ADVIA Chemistry XPT System*** is engineered for continuous operation and timely, accurate results—supporting you to reach your full potential today and be prepared for tomorrow. With an advanced user interface that is easy to use and VeriSmart Technology to support accuracy of testing, the ADVIA Chemistry XPT System predictably and consistently delivers timely, reliable results to meet expanding workloads. Simplified, Continuous Operation Simplify operation and training with the intuitive, icon-driven user interface. Extend walkaway times with concentrated reagents that provide high test capacity onboard. Quickly load most system fluids on the fly. Automate calibration, QC, startup, and shutdown. Consistent, Predictable Turnaround Time and Accuracy Offer a comprehensive chemistry menu of over 115 assays, including general and specialty chemistry, DAT, TDM, and specific proteins. Push productivity with a throughput of up to 2400 tests per hour (1800 photometric, plus 600 ISE). Control testing: STAT and specialty samples can always be front-loaded while an automation track is running. Designed for Automation Adapt and grow with direct connectivity to Siemens Healthineers and . Simplify your laboratory operations with connectivity to IT solutions including , , and . Increase productivity and efficiency with direct-from-track sampling and onboard aliquoting that allows samples to be immediately released to the next workstation. Do More with Less Reduce blood-draw requirements with micro-volume technology that uses a single 30 μL sample for up to 15 tests. Eliminate sample callback with automated, pre-programmable dilution, reflex, and rerun testing that uses an onboard aliquot. Improve workflow and accuracy with VeriSmart echnologies that perform hardware and software checks at all stages of sample processing.

Send Message
product image
Clinical Chemistry

With cutting-edge LED technology, the HyLED 7 Series offers excellent luminous efficiency, heat-free light source, and incredible long service life, giving you total support in OR. Usage/Application Operation Theater Positioning Ceiling Mounted Model Name/Number HyLED 7 Series Brand Mindray Light Source Type LED Central illuminance at 1m distance 160,000 lux Light field diameter(at 1m distance) 180~300 mm Depth of illumination(L1+L2) 1,200 mm Correlated color temperature 4,350 K Color rendering index(Ra) 96 Color rendering index(R9) 97 Shadow dilution with tube 100% Shadow dilution with one mask 75% Shadow dilution with tube and one mask 70% Shadow dilution with two masks 55% Shadow dilution with tube and two masks 50% Ambient illumination 8,000 lux Bulb power consumption 85 W Power supply 100~240 VAC, 50/60 Hz Number of LED bulbs 32 Light head dimension 600 mm Integrated Camera Optional Carrier-arm Camera Optional HyLED 7 Series Contact Us With cutting-edge LED technology, the HyLED 7 Series offers excellent luminous efficiency, heat-free light source, and incredible long service life, giving you total support in OR. Efficient & Economic • Incredible long service time up to 60,000 hours • Central Illumination: 160,000 lux/130,000 lux • Adjustable light field diameter • Max. depth of Illumination : 1,200 mm • Low power consumption Original & Unique • Perfectly integrated into laminar flow (Certified per DIN-1946 Part 4) • Touch screen panel for easier control • 330° rotatable integrated HD/FHD camera • Ultra-thin design & excellent maneuverability • Ergonomic and compact design less than 12kg Ergonomic and Compact Design • The ultra-thin concentrically circular design for better hygiene. • DIN-1946 Part 4 certificated. (12-2008) Flexible Design • Combined with an Ondal spring arm maximizes mobility and ensures stability. • Ultra-thin light head with only less than 12 Kg. • Smooth, metal back cover of the light head. High Performance • With a minimum lifetime of 60,000 hours, each latest generation LED illuminates far longer than traditional light sources. • Easier and less costly maintenance: each LED bulb with individual circuit can be replaced respectively, which will minimize the maintenance cost. Easy and Intuitive Control • Traditional control panel • Touch screen panel(optional) Shadow-free The HyLED 7 Series surgical light inherits the advanced technology from the HyLED 9 series and shows excellent shadow management function. The professional shadow dilution experiment simulated extreme situations by using tubes and masks proved that Mindray HyLED 7 Series surgical light has sufficient illumination even in extreme situations. Camera System for Communication The camera system provides better communication and documenting solutions. The camera system integrated with the surgical lights also provides a platform for medical research purpose, teaching communication and video documenting. Digital video recorder Supporting external USB storage device Supporting HDMI/YPbPr/HD-SDI/DVI-D/VGA input signal Default with camera control function Supporting video recording from other medical devices source

Send Message
product image
Hematology

BC-6800 Today, laboratories not only need more reliable routine CBC plus 5-part diff WBC testing by way of high processing speed, but are also looking for options that extend the analyzer's output in form of Reticulocytes, Nucleated RBCs, Fluorescent Platelet counts etc. for wider clinical application and research. On the other hand, they are restricted by limited budgets. BC-6800 can help to meet all these needs just perfectly and even exceed the expectations. Additional parameters for further clinical applications IMG(#,%) parameters provide information about immature granulocyte, including promyelocytes, myelocytes and metamyelocytes. HFC*(#,%) parameters represent high fluorescent cell population, such as blasts and atypical lymphocytes. RET(#,%) extend valuable help in the differential diagnosis and/or therapeutic monitoring of anemias. IRF is parameter concerning immature reticulocytes, which can assist in early diagnosis of anemia and monitoring the bone marrow response to therapy. InR*(#,‰) are parameters regarding infected red blood cell. The red blood cells may infected by plasmodium, which can cause malaria. * means research parameters SF Cube Technology SF Cube is a pathbreaking technology for reliable blood cell analysis, including WBC differential, Reticulocytes and NRBC with efficient flagging. After reaction with proprietory reagents, the targeted blood cells undergo 3D analysis using information from scatter of laser light at two angles and fluorescence signals. The 3D scattergram builds the power to better identify and differentiate blood cell populations, especially to reveal abnormal cell population undetected by other techniques. Minimizing interference to ensure more accurate results NRBCs are counted in a dedicated channel by SF cube method, which automatically corrects total WBC count and 5-part Diff results when NRBCs are detected. The Focusing Flow-DC method minimizes the interference traditionally encountered in DC technology to produce near gaussian histograms. PLT-O result avoids the interference from microcytic and fragmented RBCs, large platelets and/or platelet clumps by fluorescent stain, and enhances the results accuracy and sensitivity. High automation to minimize the workload Throughput for 125 tests/hour, autoloader for 100 sample tubes capacity Bi-directional LIS with HL7 or ASTM communication protocol Customizable re-exam rules allow users to define their re-exam criterion according to lab’s practice

Send Message
product image
Medical Equipment

Mindray believes the best way to predict the future is to create it. The revolutionary BeneVision N22/N19 is designed to optimize user experience by satisfying all your clinical demands. With visionary-stimulating design, benchmarking ease of use, confidence-maximizing innovations and workflow-transforming interoperability, BeneVision N22/N19 is creating tomorrow’s monitoring perspective today. The design excellence of BeneVision N22/N19 has great originality to lead your perspective. A seamless outlook optimizes your monitoring experience with super large touchscreen, cool rotatable landscape & portrait layout, ultra slim main unit as well as plug-n-play modules. An ingenious user interface including multi-window flat menus, infographic alarm indications and online user guide offers extremely intuitive patient data and ultimate ease-of-use, while auto screen brightness always keeps patient in mind. Benefitting from cutting-edge clinical measurements, such as rSO2, ICG, PiCCO, AG, RM, BIS, NMT, and state-of-art clinical decision support tools, such as HemoSightTM, ST GraphicTM, DSA, BeneVision N22/N19 enhances your clinical confidence to the max and helps you make easier and faster clinical decisions. The connectivity capabilities of BeneVision N22/N19 fit seamlessly into your clinical workflow for paperless future. Revolutionary iView clinical informatics workstation brings all intelligence (PACS, LIS, EMR, etc) on screen at point of care for one-stop diagnosis. Industry-leading BeneLink integrates all bedside devices to the monitor realtimely and facilitates centralized data management.

Send Message
product image
Instruments

The new and improved RTR-1 uses an image processing method. During measurement, the lateral flow device is captured using a 5-mega pixel camera and the picture is analyzed using image processing algorithms for identification of either presence or absence of test line bands or test line band intensity levels. The reader converts the image into a grayscale and then classifies the intensity levels of the image in 0 to 255 grayscale range. The image processing algorithm undergoes various levels of filtering and segmentation to yield the correct intensity levels from the picture. Based on the preconfigured intensity levels, the reader classifies the band intensity and reads out the results as either positive or negative. ACCURACY: Less than 3% intra-run CV Eliminates subjective interpretation by operator FLEXIBILITY: Single mode for low volume test setting Batch mode allows for high volume test setting Result output as semi-quantitative line intensity and visual image EASE-OF-USE: Built in barcode reader provides faster test setup Touch screen interface for easy operation Lightweight (0.7kg) and portable DATA MANAGEMENT: Results presented on screen, on a printout or uploaded to reader database Storage capacity of 1,000 test results (including images) Laboratory Information System (LIS) and Wi-Fi compatible Human Machine Interface 4-inch resistive touch screen Camera 5 mega pixel CMOS camera Barcode Scanner Integrated 1 dimensional barcode scanner Printer 48 mm inbuilt thermal printer Mode Single mode and batch mode operations Port/USB Data export and software upgrade through 2 USB ports Storage Storage capacity of 1000 test results (including images) Result output “Positive or Negative” as well as quantitative test line intensity Power 12V 2A Processor ARM Cortex-A53 Platform Embedded Linux Dimension 220 mm X 170 mm X 110 mm (L x B x H) Weight 0.7 kg (Approx CATALOG # PRODUCT RTR-1 Rapid Test Reader OTHER PRODUCTS YOU MIGHT BE INTERESTED IN.. CATALOG # PRODUCT ADX-110 ELISA Reader ADX-120 Microplate Washer

Send Message
product image
BP Apparatus

Our company has earned accolades in offering Retinoscope to the clients. Retinoscope is widely demanded in different hospitals, nursing homes and other medical institutes for the treatment of various eye diseases. This product is known for its dimensional accuracy. Offered range has the unique quality of one-hand operation and the comfort of a rubber brow rest. This product is manufactured with the best quality components under the supervision of skilled professionals in compliance with quality standards. The offered range is acknowledged for corrosion resistance, high strength, compact design, easy usage, and long service life. Features: Hassle-free performance Long lasting High-grade quality Product Details: Usage Laboratory Illumination Source 3.5V/2.8W halogen bulb Streak 3 to 50 mm Working Distance 0.67 m Streak Rotation 360 Degree Type Retinoscope

Send Message
product image
Urinalysis Analyzer

Palm-sized, fitting easily into a doctor's bag or uniform pocket. The printer can be separated from the "PocketChem" analyzer, leaving it with a weight of just 180g. Corrective features for obtaining accurate test results Accurate readings can be obtained by eliminating the effects of chromaturia using the color correction test pad, by compensating measurements for the temperature of the surrounding environment using a built-in temperature sensor and by correcting specific gravity based on pH readings. Palm-sized analyzer driven by two batteries The analyzer is detachable from the printer. The analyzer is really portable and mobile. Simple operation. Just press the start button Measurement is performed by simply pressing the start button and placing a test strip. Test results can be simultaneously viewed on the display and printed out from the printer. Reliable test results with Creatinine correction Even with the use of spot urine, test results are reliable and are not affected by urine dilutions or concentrations. The P/C ration or A/C ratio is effective for the screening of renal diseases. Sample Urine Test strips AUTION Sticks/ Uriflet S (9UB)* / AUTION SCREEN * Except devices with 10V specifications Measurement items GLU (glucose), PRO (protein), BIL (bilirubin), URO (urobilinogen), S.G. (specific gravity), BLD (blood), PH (pH), KET (ketones), NIT (nitrite), LEU (leukocytes), CRE (creatinine) and ALB (albumin). Measurement principle Test strip: Dual wavelength reflectance method. (one wavelength for BLD measurement) Measurement wavelengths 3 wavelengths LED (565, 635, 760 nm) Sample supply method Manual dipping Measurement capacity 50 tests per hour Test strip reaction time About 60 seconds per test Measurement types Normal measurement and check measurement Display Custom LCD that displays information including type of test strip, measurement number (up to 4 digits), patient ID (up to 13 digits) and test results. Operator panel Panel sheet that provides 14 buttons including numeric buttons and start button. Memory capacity Test results for 100 samples External output Compliant with RS-232 C Measurement environment Temperature: 10 to 30 °C; Humidity: 30 to 60 % R.H. (non-condensing) *Temperature correction function used Dimensions 124 (W) x 81 (D) x 36 (H) mm Weight 180 g (without batteries) Power supply Instrument only: Two AA alkaline batteries or AC adapter Instrument with printer: AC adapter 7.5 V 3 A Power consumption 3 W Printer specifications Printer Thermal recording printer Printer paper High color development thermal paper (W 58 mm x φ26 mm) Dimensions 125 (W) x 133 (D) x 36 (H) mm Weight 180 g (without printer paper) Power supply AC adapter 7.5 V 3 A Power consumption 20 W

Send Message
product image
Urinalysis Analyzer

The AUTION ELEVEN AE-4020 is intended for the qualitative and/or semi-quantitative measurement of several physiological markers in urine: Glucose, Protein, Bilirubin, pH, Blood, Urobilinogen, Ketones, Nitrite, Leukocytes, Creatinine, Albumin, Specific Gravity, P/C (Ratio of Protein to Creatinine) and A/C (Ratio of Albumin to Creatinine). These measurements are used for screening of kidney disease, liver disease, diabetes mellitus and urinary tract infection in general screening populations. Compact Design: 210(W) x 328(D) x 164(H) mm / Approx. 3.6 kg Processing speed: 514 samples per hour (maximum processing mode: 7 second interval) Auto-start function: Measurement starts automatically when a strip is set on the tray. Test strip can be placed either from the left or the right side. Maximum 11 parameters and color tone can be measured simultaneously by special test strips designed and made by ARKRAY. *Some products including test strips may not be available in all countries. Please check with your local Arkray representative or distributor about product availability in your area. Sample Urine Test Strip / Reagent pack AUTION Sticks / Uriflet S / AUTION SCREEN Measurement item GLU, KET, BIL, NIT, PRO, URO, pH, BLD, LEU, ALB, CRE, Specific Gravity, color tone Measurement range Test strip: As Rank table Color tone: As Color tone classification chart Measurement method Test strip method Dual-wavelength reflection photometric method (single wavelength for BLD) Measurement wavelength 4-wavelength LED (430, 565, 635, and 760 nm) Test strip reaction time 60 seconds Processing speed 514 samples per hour (maximum processing mode: 7-second interval) Display Custom LC display (icons are used) Built-in printer 32-digit thermal printer (58 mm width) External output Conforms to RS-232C standard (serial) Option: Ethernet Memory capacity 520 measurement results Temperature correction Auto-correction by the internal temperature sensor (between 10 to 30 °C) S. G. correction Auto-correction by pH values Chromaturia correction Auto-correction by the color tone correction section on test strips Operating environment Temperature: 10 to 30 °C; Humidity: 20 to 80% R.H. (non-condensing) Measurement environment Temperature: 10 to 30°C; Humidity: 30 to 60% R.H. (non-condensing) *Temperature correction function used DC power requirements(To instrument) 12 Vdc 3 A AC power requirements(To AC adapter) 100-240 Vac 50-60 HZ ,1200 mA Voltage fluctuation allowance is ±10% Power consumption Max. 45 VA Dimensions 210 (width) × 328 (depth) × 164 (height) mm Weight Approx. 3.6 kg

Send Message
product image
Urinalysis Analyzer

High Performance "Full Automated System" Color Touch Panel for good usability 7 inch WVGA color touchscreen with high operability displays measurement results, instrument conditions and operating instructions. "Sample delivery system" enables micro volume samples to be measured As the sample is drawn through the nozzle and delivered correctly and quantitatively to each pad of the strip, the micro volume samples (minimum 1mL) can be measured easily. No cross contaminations are found on the reagent portions despite high sample volume. Sample Urine Test items Glu, Pro, Bil, Uro, Ket, pH, Nit, Bld, Leu, S.G., Alb, Cre(Alb/Cre ratio, Pro/Cre ratio can be calculated), turbidity and color tone Wavelength 5 LED wavelengths (430, 500, 565, 635, 760nm) Measurement principle Test strip :Dual-wavelength reflectance method (One-wavelength for Bld) Specific gravity :Reflection refractometryColor hue :Light-transmission measurementTurbidity :Light-scattering measurement method Test strip AUTION Sticks (10EA & 10PA) , Uriflet S 11UA Reaction time Approximately 60 seconds Throughput 225 samples per hour Strip storage Maximum 400 strips (200 strips x 2 feeder boxes) Required sample volume Normal, STAT measurement: Minimum 2 mL Small volume measurement: Minimum 1 mL Sample consumption Normal, STAT measurement: Maximum 0.90 mL Small volume measurement: Maximum 0.45 mL Sample container Sample tubes (length: 95 - 110 mm, diameter: ø14.0 - 15.8 mm) Maximum sample load 100 samples (Circulation) Data memory Normal, STAT, small volume measurement: 2500 tests Control measurement: 200 tests Check measurement: 50 tests Trouble list: 100 tests Display Large color liquid crystal display (800 × 480 dots) Built-in printer 58-mm width printer paper (24 digits) External output 1 port (Replaceable with the optional Ethernet terminal) Communication method RS-232C compliant (Switchable between one-way and two-way) Measurement environment Temperature: 10 - 30°C; Humidity: 30 - 60% RH (No condensation) Power requirements 100 - 240 V AC (Maximum power line fluctuation of ±10%), 50/60 Hz Power consumption 150VA (Maximum) Dimensions 530 (W) × 530 (D) × 550 (H) mm (including the sampler) Weight Main body: Approximately 36 kg Sampler: Approximately 4 kg

Send Message

Still searching for
orr?