Jaipur
+918529833535

'optional lis connection function'

Items tagged with 'optional lis connection function'

product image
Immunology Analyzer

Product Description: The LisaScan EM Microplate Reader is an economical, compact and versatile 8 channel ELISA reader which can be adapted to various ELISA applications. It is India’s largest selling automated microplate ELISA reader Product Features: Wavelength Range: 400 to 750nm with a dynamic measurement range of 0.0 to 4.0 O.D 100 user-programmable test storage Inbuilt thermal printer for reports & graphs Auto self-check on start-up & external printer connectivity Compatible to various plate geometrics-96 well microplates ( Flat, U & V bottom) Wavelength selection: Monochromatic, bi-chromatic & multi-chromatic* Reading time 8 sec. for single wavelength using 8-channel optics User-friendly inbuilt operation software with 7000 sample test results storage User interface: High Resolution LCD display with 20 Keys Rugged waterproof & membrane panel Computer linked ELISA data management software - Eli-LIMS* CE marked Inbuilt shaking facility,Three Linear Speeds - Low, Medium and Fast Reports can be printed using internal thermal or external printer No need of manual calculations and documentation Documentation ease – Reports can even be stored using optional Eli-LIMS software Computer can be connected Extensive ELISA data management Product Applications: ELISA System type: Open System Plate types: 96 well plates Wells Type: U, V and Flat bottom wells Operating Modes: Absorbance Quantitative Qualitative Semi-Quantitative Kinetic Mode Measurement Modes: Continuous / Step Shaking Modes: Three Linear Speeds - Low, Medium and Fast. Time duration can be set Wavelength Selection: Monochromatic Bi-Chromatic Multi-Chromatic* (Maximum 4) Calculation Modes: Non-linear Standard Cut-off Index Formula Column Subtraction Linear Regression Point to Point Cubic Spline Linear – Log Blank Options: Blank, Control, Assay Validation equations Against Air, Well Plate, Column, Column-mean Row, Row mean Number of programmable standards / calibrators: Up to 10 standards /test Storage/ display/ printing of multi standard curves and cut-off equations for all parameters Test Programs: 100 totally “open” Test Programs Photometer: Measuring system: 8-Channel optical system Lamp Source: Tungsten Halogen with Lamp saver function Wavelength Range: 400 to 750 nm Standard Filters: 405 nm, 450 nm, 492 nm, 630 nm (Optional two filters 578 nm, 700 nm), 10 nm Band Pass Dynamic Range: 0.0 ~4.0 OD Photometric accuracy: < 1% at 2.5 OD at 450 nm Photometric resolution: 0.001 OD Linearity: <1% at 2.5 OD at 450 nm Measurement Time: SPEED : 8 Seconds single wavelength NORMAL : 17 Seconds single wavelength Display: High resolution Graphics LCD 320x240 pixels, LED Backlight, View area: 120x92 mm Keyboard: Rugged waterproof & membrane panel PC Communication: USB Based Protocol compatible with Eli-LIMS and TNW Built-in Thermal Printer: Built in High resolution, 384 dots per line, thermal Type with full graphics facility printer and option for connecting External Parallel Printer (or USB Printer using External Adaptor). Computer interfacing Software: Windows Based Software Eli-LIMS with data managemenOptional Windows Based Software with data management capabilities to store patient results, store/display calibration curve /QC curves. Reports on internal and external printers: Report generation for last 7000 Sample’s is viewed/printed/stored. Lab name in Print-out Lab name in Display Collated reports Print-out of Normal Range along with the result (on external printer only). Graphs can be printed on Thermal Printer Sorted by: Date I.D. Both by Date & I.D. Test Plate ID Online Help: At each step on-line help in each menu. Beeps and online instructions on erroneous entry. Special HELP key on keypad. Operating Temperature: 20˚ C to 40˚ C Storage Temperature: -10˚ C to 50˚ C Humidity: Max. 80% RH, non- condensing Power Supply: 16 V - 24.5 V DC using External Auto ranging SMPS adapter 115/230VAC ±10%, 50/60Hz., Max. 90 Watt. (CE & UL certified) Dimension: 502 mm X 369 mm X 216 mm Weight: 7 Kg

Send Message
product image
Clinical Chemistry

The Autochem Xact Pro is a Fully Automatic Random Access Clinical Chemistry Analyzer. It is a compact, benchtop analyser with throughput up to 200 tests per hour. First-in-Class On-board Warm-water Laundry System Probe with Collision-Protection System Multi function Probe which works as mixer also Probe with Capacitance based liquid level sensor Robust Multi-functional Software Intelligent" Mixing Arm Removable & flexible Sample - Reagent Disc with 40 Open position for reagent & samples respectively. DESIGNED FOR UNINTERRUPTED WORK FLOW OTHER FEATURES ROBUST MULTI-FUNCTIONAL SOFTWARE Probe with Collision-Protection System Both horizontal and vertical collision protection ensures that system re-starts testing after any unwanted physical intervention. This prevents wastage of reagents, saves test time and increases life of probe Multi functional Probe Probe has flexibility to work even as a mixer in case in-built mixer does not work Probe with Capacitance based liquid level sensor Probe with liquid level sensor checks and indicates the presence of adequate sample or reagent in the container before starting testing process. Thus prevents unwanted interruptions in testing process “Intelligent” Mixing Arm User defined, variable three level mixing speed ensure thorough mixing Accurate performance of regular and immunoturbidimetric assays Independent cleaning station for mixer which prevents carry-over ensuring high precision Removable & flexible Sample – Reagent Disc 40 Open position for reagent & samples respectively Facility to use primary & variable sample cup as well as non fixed position for Sample, Control, Calibrator & STAT samples Two bottle sizes of 18 mL or 5 mL with unique design to reduce reagent dead volume Optional internal Reagent & Sample barcode reader makes the operation user friendly & ensure correct result reporting Reaction tray 60 reusable plastic reaction cuvettes which is also scanned before performing the test which means less recurring cost without compromising on quality. To assure precise results Individual replacement of cuvette offer lower consumable cost REFLEX Testing Functionality Allows user to program Low & High panic value for a particular test which triggers auto-testing of assigned tests which ensures faster and comprehensive reporting Dynamic & Real-time display of Test Running Status for quicker decision making Running status of reagent tray, Sample tray & reaction tray Real-time monitoring of Reaction curve On board inventory management Real-time monitoring of reagent residual volume saves reagent cost & time In-built full QC Program Provision to run 3 levels of control with Levey Jennings graph which gives confidence in reporting with multiple rules (1SD, 2SD and 3SD) Reagent, Calibrator & Control lot monitoring User friendly Bi-Directional LIS Interface

Send Message
product image
Immunology Analyzer

The EUROIMMUN Analyzer I is an open system for fully automated ELISA processing of up to 7 microplates and 180 patient samples in one run. The combination of EUROIMMUN ELISAs and EUROIMMUN Analyzer I enables a quick and simple, but also a secure routine operation, owing to the automatic recognition and allocation of reagents and the import of QC data via Data Matrix codes. A further quality feature is the optionally available climate control unit, which ensures constant incubation conditions — regardless of fluctuating or excessively high laboratory temperatures. The EUROIMMUN Analyzer I is designed for medium to high sample volumes. Fully automated ELISA processing for medium to high sample volume with minimal manual input High reliability and traceability due to automatic identification of barcodes of patient samples and ready-to-use reagents Fast processing of up to 70 tests per hour and up to 7 plates and 180 samples per run Convenient operation of the software including scanning of QC certificates using a 2D-hand barcode scanner Specifications Sample types Plasma, serum, CSF and stool Patient sample capacity up to 180 samples Plate capacity up to 7 Parameter capacity per run up to 54 Shakeable incubators 4 Throughput up to 70 tests per hour Sample tubes Outer diameter 10 – 16 mm, height up to 100 mm Traceability integrated code scanner for identification of samples and reagents User interface Microsoft ® Windows ® 10 Enterprise 2019 LTSC (64 Bit) Online connection ASTM interface, bi-directional Dimensions (WxDxH) 1100 mm x 750 mm x 1000 mm Weight 130 kg

Send Message
product image
Immunology Analyzer

Product Description: Erba Lisa Wash II is a simple easy to Operate and use ELISA Plate Washer, Suitable for all ELISA applications. Programmable features like, dispense pressure, Single/double aspiration, Horizontal & Vertical adjustments ensures complete control on washing efficiency Product Features: Fully automated, easy operating system and friendly software with large-screen display 50 user programmable protocols to customize washing Easily removable 8- or 12-way manifolds Liquid level detection and alert function Low residual volume: <3 µl Soak time programmable up to 24 hrs. Compatible for flat-bottom, U and V bottom type microplates or microstrip High-efficiency ELISA washing with automated monitoring of Vacuum. Choice of 2 wash buffer bottles, 1 distilled water & 1 waste container with sensor Dispense pressure and the volume adjustable, so as to reduce the air bubbles and ensure thorough Washing Waste-bottle sensor to detect high-waste liquid levels Standard aerosol protection cover Easy maintenance CE marked Product Applications: ELISA Wash Head: 8 and 12 head manifold compatible Wash Mode: Row and Plate Wash Row: 1-12 rows Flat Bottom Plate Type: 96 or 48 well plate or strip (Flat, U & V - bottom) Wash Programs: 50 Moving Cycle: up to 12 cycles Dispensing Volume: 50 - 3000μl in 50μl increments Dispensing Precision: < 2% at 350μl Prime Volume: 50 - 1000μl Aspiration Pressure: Automatic Soak Time: 0 – 24 Hrs Residual Volume: ≤ 2μl for V/ U bottom plates, and ≤ 3μl for per well Flat bottom plates Nos. of Bottles: 2 wash, 1 Rinse/DI, 1 waste with level sensor, 2L each User Interface: 5 Inch LCD (90 x 53 mm), with Keypad Bottle Capacity: > 2 L Operating Environment Power Supply: AC 220 V/ 110 V, 50/60 Hz Input Power : < 80VA Operating Temperature: 10°C - 30°C Relative Humidity: Up to 95% relative humidity without condensation Storage Temperature: -10°C - 40°C Weight: 9.5 Kg Dimension: 710 mm x 530 mm x 380 mm

Send Message
product image
Clinical Chemistry

As the workload and test menu increase, simultaneous management of multiple ELISA protocols can become challenging. The LisaXL has been designed with an open architecture to meet various laboratory needs, providing all the tools necessary for hands-free ELISA processing, increasing the reliability and reproducibility, improving throughput, and freeing the laboratory staff from repetitive steps. LisaXL allows running multiple parameters for over 250 samples in a single batch. Equipped with dual probes and dedicated workstations, drastically improve ELISA workflows. LisaXL is a complete walkway system that minimizes manual errors while improving the accuracy and turnaround time for critical tests. LisaXL provides the flexibility to build and run virtually any ELISA assays. Product Features: Lisa XL is a true walk-away system for any laboratory needs. High Throughput with 6 plates, can process up to 576 tests. A dynamic scheduler ensures optimized system usage and turnaround times by processing 6 plates and up to 12 assays in each plate Onboard flexibility with sample capacity up to 272 and 20 interchangeable racks for reagents and samples. Dual probe processing ensures speed and reliability. "Zero" carryover with high-quality disposable tips. Six individually controlled incubators and shakers with variable temperature, time, and speed settings. Efficient washing with super sweep mode ensures minimum residual volume, with up to 6 different wash buffers. Easy to use touchscreen graphic user interface Product Applications: ELISA Physical Specifications 1 Dimensions Length 1375 mm 55" Height 845 mm 33" Width 850 mm 33.5" Weight 195 kgs (Approx) Power Supply Voltage 100 - 240 Volts Frequency 50 / 60Hz Power consumption 700 W General Specifications Assay per plate Up to 12 Number of ELISA plates Up to 6 Sample capacity Up to 272 Sample / Reagent capacity Total 20 racks Single rack holds 16 sample / reagent tubes Double rack holds 6 x 60 ml reagent bottles (can be used interchangeably) Tip / Dilution box Total 11 locations of 96 capacity each (can be used interchangeably) Reader Specifications Reading Range 0.0 - 3.5 O.D Reading Channels 8 Filter wheel 8 positions 405 nm, 450 nm, 492 nm, 620 nm std* 578 nm and 700 nm optional + 2 open Light source Halogen Lamp Reading mode Single, Dual, ORR Reading time < 1 min (for single filter) Linearity Up to 3.0 O.D (450 nm) Washer Specifications Manifold configuration 16 needles - 8 aspiration & 8 dispensing Precision < 5 % at 300 μl Wash cycle Programmable Residual volume < 5 μl / well Soak time Programmable Washer buffer capacity 6 × 2.25 L Waste water container 1 × 20 L Incubator Specifications Number of incubators Up to 6 Temperature range RT + 5°C up to 50°C Temperature stability ± 1°C Incubation time Programmable Time to set temperature < 6 min Shaking 200 to 800 RPM Shaking Method Orbital Pipetting Specifications Number of probes 2 Tips 300 µl / 1000 µl, Auto / Manual selected Multi-dispensing (Reagent) Minimum volume 4 μl Serum dispensing time < 14 min Reagent dispensing time < 5 min Sample mixing Yes (Automatic) Precision Sample & Reagent Sample Dispensing with 300 µl tip: 3% above 10 µl ± 0.5 µl for 10 µl & less Reagent Dispensing with 300 µl tip: 3% for 25 µl & above Reagent Dispensing with 1ml tip: 5% for 75 µl & above" Process Security Liquid level sensing Well fill verification Clot detection Onboard sample identification Onboard reagent identification Strip verification Buffer sensing Alarms Software Operating System Windows 10 (Embedded) LIS interface Bi-directional, Serial / TCPIP USB Port Graphic load interface Graphical work list Data processing Quantitative, Semi-Quantitative & Qualitative Multi password access Ability to archive data Computer (Base configuration considered, higher configuration can be considered for upgrade after testing) Intel Core i3, 4 GB RAM, 1 TB hard disk Monitor 22" Full HD touch screen

Send Message

Still searching for
optional lis connection function?