Jaipur
+918529833535

'operational biohazard'

Items tagged with 'operational biohazard'

product image
Hematology

The BC-3600 Hematology analyzer features closed tube sampling via a single push button. A built-in large 10.4 inch color touchscreen allows maximum visibility. Hemoglobin analysis is performed using cyanide-free reagent. The analyzer processes up to 60 samples per hour and stores up to 40,000 results with histograms. The barcode reader and optional LIS connectivity enable seamless sample data transmission. Nearly all scheduled maintenance procedures are automated by touch buttons. The intuitive software enhances workflow efficiency and provides operators with a pleasant user experience. Key Features CBC plus 3-part differential, 16 parameters + 3 histograms 60 samples per hour, 1 min per CBC Closed tube sampling, minimize operational biohazard Built In diluent dispenser for predilution mode All-in-one CBC result screen display; results at a glance Touch button maintenance procedures One maintenance reagent only – probe cleaner Storage capacity of 40,000 results with histograms Uploadable QC files; ensure accuracy and time efficiency Parameters WBC, Lymph#, Mid#, Gran#, Lymph%, Mid%, Gran%, RBC, HGB, HCT,MCV, MCH, MCHC, RDW,PLT, MPV and histograms for WBC, RBC, PLT Principles Electrical impedance method for cell counting and Cyanide - free for hemoglobin Sample Volume Prediluted 20µL Whole Blood 21µL Carryover WBC/RBC/HGB≤0.5% PLT≤1.0% Connectivity 4 USB ports (for external printer, software upgrade, barcode reader,keyboard and mouse), LAN port (1), RS232 (1) Printout Thermal recorder, 50mm width paper, various printout formats, external printer (optional) Product Specification Brand Mindray Differential Type 3-Part Model Name/Number BC 3600 Display Type Large color touch screen Resolution 800x600 Usage/Application Hospital Throughput 60 samples per hour Power Supply AC 100-240V,50/60 +-1Hz Weight 62 lbs Dimension 16 in(W) x 18 in(H) x 18 in(D) Humidity 30%-85% Temperature 15 ~30 Deg C Minimum Order Quantity 1

Send Message
product image
Rapid Test

Buy AccuTest COVID-19 IgG/IgM Rapid Test (Pack of 10 Tests) Online. COVID-19 IgG/IgM Rapid Test Kit is a qualitative immuno chromatographic assay for the detection of IgG & IgM antibodies produced against COVID-19 virus in human whole blood/Serum/ Plasma. COVID-19 IgG/IgM Rapid Test Kit is only intended for initial screening and reactive samples should be confirmed by a supplemental assay. Intended Use: COVID-19 IgG/IgM Rapid Test Kit is a qualitative immuno chromatographic assay for the detection of IgG & IgM antibodies produced against COVID-19 virus in human whole blood/Serum/ Plasma. COVID-19 IgG/IgM Rapid Test Kit is only intended for initial screening and reactive samples should be confirmed by a supplemental assay. SUMMARY & TEST DESCRIPTION: COVID-19 [Coronavirus Disease- 2019] is an infectious disease caused by SARS-CoV2 [Severe Acute Respiratory Syndrome coronavirus 2] virus, which is a contagious, novel strain of CoronaVirus that emerged from Wuhan, China in December 2019, which grew as a pandemic threatening human survival across the globe. The virus is thought to be of zoonotic origin and likely to have spread from large seafood and animal markets by human-animal contact in the city of Wuhan, where consumption of such products is in large. The virus causes respiratory infection with symptoms including fatigue, fever, shortness of breath, respiratory failure, renal failure and death. Patients can become infected with SARS-CoV-2 virus by person-person contact (through contact with a contaminated environment or person). The young and old (and other immune-compromised individuals) are most at risk of serious complications; however, approximately 20% of those infected can develop a critical condition. COVID-19 IgG/IgM Rapid Test device utilizes Anti-human IgG and Anti-human IgM antibodies as the capture molecules. COVID-19 Recombinant Antigens-colloidal gold conjugate are used as detection antigen. Intended Use: COVID-19 IgG/IgM Rapid Test Kit is a qualitative immuno chromatographic assay for the detection of IgG & IgM antibodies produced against COVID-19 virus in human whole blood/Serum/ Plasma. COVID-19 IgG/IgM Rapid Test Kit is only intended for initial screening and reactive samples should be confirmed by a supplemental assay. SUMMARY & TEST DESCRIPTION: COVID-19 [Coronavirus Disease- 2019] is an infectious disease caused by SARS-CoV2 [Severe Acute Respiratory Syndrome coronavirus 2] virus, which is a contagious, novel strain of CoronaVirus that emerged from Wuhan, China in December 2019, which grew as a pandemic threatening human survival across the globe. The virus is thought to be of zoonotic origin and likely to have spread from large seafood and animal markets by human-animal contact in the city of Wuhan, where consumption of such products is in large. The virus causes respiratory infection with symptoms including fatigue, fever, shortness of breath, respiratory failure, renal failure and death. Patients can become infected with SARS-CoV-2 virus by person-person contact (through contact with a contaminated environment or person). The young and old (and other immune-compromised individuals) are most at risk of serious complications; however, approximately 20% of those infected can develop a critical condition. COVID-19 IgG/IgM Rapid Test device utilizes Anti-human IgG and Anti-human IgM antibodies as the capture molecules. COVID-19 Recombinant Antigens-colloidal gold conjugate are used as detection antigen. PRECAUTIONS & WARNING 1. This package insert must be read completely before performing thetest. Failuretofollow directions in insert may yield inaccurate test results. 2. Test results should be read between 10 and 15 minutes after aspecimenisapplied to the sample well. Results read after 20 minutes may giveerroneousresults.3. Do not open the sealed pouch until you are ready to conduct theassay.Onceopened, the cassettes should be used immediately. 4. Do not use expired devices. 5. Bring all reagents to room temperature (15-30°C) prior to use. 6. Do not mix components from different kits. Use only the buffer suppliedalongwith the kit. 7. Wear protective clothing and disposable gloves while handling thekit reagentsand clinical specimens. Wash hands thoroughly after performing thetest. 8. Do not smoke, drink, or eat in areas where specimens or kit reagents arebeinghandled. 9. Dispose of all specimens and materials used to performthe test as biohazardouswaste. 10. Handle the negative and positive controls in the same manner as patientspecimens for operator protection. 11. Do not perform the test in a room with strong air flow, i.e. an electricfanorstrong air-conditioning. 12. Do not touch result window. 13. Use only for in-vitro diagnostic purpose.

Send Message
product image
Rapid Test

Buy AccuTest Typhoid IgG/IgM Rapid Card Test (5 Tests) Online from Accurex. The Typhoid IgG/IgM Rapid Test is used for detection & differentiation of anti-Salmonella typhi (S. typhi) IgG and IgM in human whole blood / serum / plasma. This Typhoid test is used as a screening test and as an aid in the diagnosis of infection with S. typhi. Salmonella typhi bacteria causes typhoid Typhoid fever, typhoid symptoms symptoms are likely to develop gradually – appearing one to three weeks after exposure to the disease. There are various typhoid treatment & typhoid vaccine which can be opted after the detetction of Typhoid. Typhoid fever is caused by S. typhi, a Gram-negative bacterium. Worldwide an estimated 17 million cases and 600,000 associated deaths occur annually. Patients who are infected with HIV are at significantly increased risk of clinical infection with S. typhi. Evidence of H. pylori infection also presents an increased risk of acquiring typhoid fever. 1-5% of patients become chronic carrier harboring S. typhi in the gall bladder. The clinical diagnosis of typhoid fever depends on the isolation of S. typhi from blood, bone marrow or a specific anatomic lesion. In the facilities that can not afford to perform this complicated and time-consuming procedure, Filix-Widal test is used to facilitate the diagnosis. However, many limitations lead to difficulties in the interpretation of the Widal test. In contrast, the Typhoid IgG/IgM Rapid Test is a simple and rapid laboratory test. The test simultaneously detects and differentiates the IgG and the IgM antibodies to S. typhi specific antigen thus to aid in the determination of current or previous exposure to the S. typhi. PRINCIPLE The Typhoid IgG/IgM Rapid Test is a lateral flow immunochromatographic assay. The test cassette consists of: 1) a pink-purple colored conjugate pad containing recombinant S. typhi H antigen and O antigen conjugated with colloid gold (Typhoid conjugates) and rabbit IgG-gold conjugates, 2) a nitrocellulose membrane strip containing two test region (Test line M and G) and a control region (control line). The test line ‘M’ is pre-coated with monoclonal anti-human IgM for the detection of IgM anti-S. typhi, test line ‘G’ is pre-coated with monoclonal anti-human IgG for the detection of IgG anti-S. typhi , and the C band is pre-coated with goat anti rabbit IgG. When an adequate volume of test specimen is dispensed into the sample well of the cassette, the test specimen migrates by capillary action across the test cassette. Anti-S. typhi IgM if present in the patient specimen will bind to the Typhoid conjugates. The immunocomplex is then captured on the membrane by the pre-coated anti-human IgM antibody at test region ‘M’, forming a pink-purple line at ‘M’ region, indicating a S. typhi IgM positive test result. Anti-S. typhi IgG if present in the patient specimen will bind to the Typhoid conjugates. The immunocomplex is then captured by the pre-coated reagents on the membrane, forming a pink-purple line at test region ‘G’, indicating a S. typhi IgG positive test result. Absence of any pink-purple line at test region (M and G) suggests a negative result. The test contains an internal control (control line) which should exhibit a pink-purple line of the immunocomplex of goat anti rabbit IgG/rabbit IgG-gold conjugate regardless of the color development on any of the test region. Otherwise, the test result is invalid and the specimen must be retested with another device. PRECAUTION 1. This package insert must be read completely before performing the test. Failure to follow the insert gives inaccurate test results. 2. Do not open the sealed pouch, unless ready to conduct the assay. 3. Do not use expired devices. 4. Bring all reagents to room temperature (15°C-30°C) before use. 5. Do not use the components in any other type of test kit as a substitute for the components in this kit. 6. Do not use hemolized blood specimen for testing. Wear protective clothing and disposable gloves while handling the kit reagents and clinical specimens. Wash hands thoroughly after performing the test. 7. Users of this test should follow the US CDC Universal Precautions for prevention of transmission of HIV, HBV and other blood-borne pathogens. 8. Do not smoke, drink, or eat in areas where specimens or kit reagents are being handled. 9. Dispose of all specimens and materials used to perform the test as biohazardous waste. 10. Handle the Negative and Positive Control in the same manner as patient specimens. 11. The testing results should be read within 15 minutes after a specimen is applied to the sample well or sample pad of the device. Read result after 15 minutes may give erroneous results. 12. Do not perform the test in a room with strong air flow, ie. an electric fan or strong air-conditioning. Other Info STORAGE AND STABILITY Typhoid IgG/IgM test card should be stored at 4-40°C. The card may be stored at room temperature but not exceeding 40°C in the original sealed pouch. The shelf life or expiry of the card is printed on Pouch as well as carton label. The test kit should be kept away from direct sunlight, moisture and heat.

Send Message
product image
Rapid Test

Buy Dengue NS1 Antigen test (Pack of 5 test) from Accurex. This NS1 Antigen Rapid test contains: A Test device in aluminum pouch with a desiccant, Disposable dropper & Pack Insert. Dengue NS1 antigen test utilizes the human serum / plasma followed by solid-phase immuno-chromatographic technology for the qualitative detection of dengue virus NS1 antigen. Dengue NS1 Antigen kit is for professional use and only for the initial screening test & reactive samples should be confirmed by a supplemental assay such as nucleic acid test & other immunological assays. EXPLANATION OF THE TEST Dengue NS1 antigen test utilizes the human serum / plasma followed by solid-phase immuno-chromatographic technology for the qualitative detection of dengue virus NS1 antigen. The membrane strip of the kit contains pre-coated anti-dengue NS1 monoclonal antibody on the test band region (T), and goat anti-mouse IgG is pre-coated on the control band region (C). During testing, if the sample containing dengue NS1 Ag, the complex of the antibody-dengueNS1 Ag-gold conjugate moves laterally on the membrane by capillary action. In this case, the colored band will appear on the membrane in test line (T). Control line (C) should always appear if the test procedure is performed properly Safety Information 1. For in-vitro diagnostic use only. Do not re-use the test device. 2. The instruction must be followed exactly to get accurate results. 3. Anyone performing an assay with this product must be trained in its use and must be experienced in laboratory procedures. 4. Do not eat or smoke while handling specimens. 5. Wear protective gloves while handling specimens. Wash hands thoroughly afterwards. 6. Avoid splashing or aerosol formation. 7. Clean up spills thoroughly using an appropriate disinfectant. 8. Decontaminate and dispose of all specimens, reaction waste, in a biohazard container. 9. Do not mix and interchange different specimen. 10. The presence of humidity may decrease the stability of the tests. Thus, carry out the test immediately after removing the device from the foil pouch. 11. Do not use it beyond the expiration date. Direction for Use 1. Place all specimens, test device and solution. Allow them to room temperature prior to testing (15~30 min.) 2. Please perform the test immediately after removing the device from the foil pouch. 3. With a disposable dropper, load 2-3 drops (50 to 75µl) of specimen into the sample well (S) in the test device. 4. Interpret the test results between 15~20 minutes. Do not read the results after 20 minutes. Other Info 1) Dengue NS1 Antigen test should be stored between 4~30 ºC 2) Expiration date of this kit is 24 months after its manufacture date. LIMITATIONS OF THE TEST Dengue NS1 antigen test is designed for primary screening test of dengue virus NS1 antigen. Although this can provide fast and easy way to get a result, the testing do not completely exclude the possibility of false positive or negative result caused by various factor. So, refer to the result of the kit, please make a final decision with clinical manifestation, other test results and doctor’s view collectively.

Send Message
product image
Rapid Test

Buy Dengue NS1 Antigen test (Pack of 10 test) from Accurex. This NS1 Antigen Rapid test contains: A Test device in aluminum pouch with a desiccant, Disposable dropper & Pack Insert. Dengue NS1 antigen test utilizes the human serum / plasma followed by solid-phase immuno-chromatographic technology for the qualitative detection of dengue virus NS1 antigen. The membrane strip of the kit contains pre coated anti-dengue NS1 monoclonal antibody on the test band region (T), & goat anti-mouse IgG is pre-coated on the control band region (C). EXPLANATION OF THE TEST Dengue NS1 antigen test utilizes the human serum / plasma followed by solid-phase immuno-chromatographic technology for the qualitative detection of dengue virus NS1 antigen. The membrane strip of the kit contains pre-coated anti-dengue NS1 monoclonal antibody on the test band region (T), and goat anti-mouse IgG is pre-coated on the control band region (C). During testing, if the sample containing dengue NS1 Ag, the complex of the antibody-dengueNS1 Ag-gold conjugate moves laterally on the membrane by capillary action. In this case, the colored band will appear on the membrane in test line (T). Control line (C) should always appear if the test procedure is performed properly PRECAUTIONS 1. For in-vitro diagnostic use only. Do not re-use the test device. 2. The instruction must be followed exactly to get accurate results. 3. Anyone performing an assay with this product must be trained in its use and must be experienced in laboratory procedures. 4. Do not eat or smoke while handling specimens. 5. Wear protective gloves while handling specimens. Wash hands thoroughly afterwards. 6. Avoid splashing or aerosol formation. 7. Clean up spills thoroughly using an appropriate disinfectant. 8. Decontaminate and dispose of all specimens, reaction waste, in a biohazard container. 9. Do not mix and interchange different specimen. 10. The presence of humidity may decrease the stability of the tests. Thus, carry out the test immediately after removing the device from the foil pouch. 11. Do not use it beyond the expiration date. SPECIMEN COLLECTION AND STORAGE Direction for Use 1. Place all specimens, test device and solution. Allow them to room temperature prior to testing (15~30 min.) 2. Please perform the test immediately after removing the device from the foil pouch. 3. With a disposable dropper, load 2-3 drops (50 to 75µl) of specimen into the sample well (S) in the test device. 4. Interpret the test results between 15~20 minutes. Do not read the results after 20 minutes. Other Info STORAGE & EXPIRATION 1) Dengue NS1 Antigen test should be stored between 4~30 ºC 2) Expiration date of this kit is 24 months after its manufacture date. LIMITATIONS OF THE TEST Dengue NS1 antigen test is designed for primary screening test of dengue virus NS1 antigen. Although this can provide fast and easy way to get a result, the testing do not completely exclude the possibility of false positive or negative result caused by various factor. So, refer to the result of the kit, please make a final decision with clinical manifestation, other test results and doctor’s view collectively.

Send Message
product image
Hematology

Buy the Best 5 Parts Hematology Analyzer – ACCULAB CBC 560+. This Hematology Analyser Machine is an advanced and automatic hematology analyzer, comprising 5 parts, 29 parameters, and 3 histograms assay, offers throughput of 60 tests/hour. Features: Tri-angle laser scatter, Flow cytometry method, Impedance method for RBC and PLT counting and Cyanide-free method for HGB test along with 3D holographic scattergram to display the accurate 5 part differentiation of WBC. Equipped with a 14 inch touch screen and large storage capacity for 100,000 results, this hematology analyzer has interface of 4 USB ports, 1 LAN port Bi-direction LIS, support HL 7 protocol, Internal RFID reader. With CBC mode, CBC+DIFF mode, Venous whole blood, Capillary whole blood and Prediluted test mode, this hematology analyzer is an ideal unit for white blood cell counts, complete blood Measuring principle Tri-angle laser scatter, Flow cytometry method, Impedance method for RBC and PLT counting, Cyanide-free method for HGB test Sample volumes CBC+DIFF mode: ≤ 20 μl CBC mode: ≤ 10 μl Throughput 60 tests/hour Assay Items 29 parameters, 3 histograms Display 14 inch touch screen Storage 100,000 sample results, including histograms, scattergrams and patient information Parameter WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PCT,PDW, P-LCR, P-LCC, NEU%, LYM%, MON%, EOS%,BAS%,NEU#, LYM#, MON#, EOS#, BAS# 4 Research parameter: ALY%, ALY#, LIC%, LIC# Performance Item Linearity range Carry Over CV WBC 0-300 × 109/L ≤ 0.5% ≤ 2.0 % RBC 0-8.00 ×1012/L ≤ 0.5% ≤ 1.5 % HGB 0-250 g/L ≤ 0.5% ≤ 1.5 % PLT 0-3000 × 109/L ≤ 1.0% ≤ 4.0 % Interface 4 USB ports, 1 LAN port Bi-direction LIS, support HL 7 protocol, Internal RFID reader Power Consumption 400 VA Power Supply AC 220V±10%, 50/60Hz, 110V±10%, 60Hz Packaging dimension (W×D×H) 670 × 590 × 790 mm Gross Weight 53 kg Safety Information All the samples, controls, calibrators, reagents, waste and areas contacted with them are potentially biohazardous. Wear proper personal protective equipment (e.g. gloves, lab coat, etc.) and follow safe laboratory procedures when handling them in the laboratory.

Send Message
product image
Clinical Chemistry

The HumaStar 300SR is the latest member of HUMAN's clinical chemistry systems. Based on the proven hardware and software quality of HumaStar 100/200 it uses the time-tested system reagent kits of HumaStar 600 with perfectly matching methods, calibrators and controls. Throughput: up to 300 tests/h Sample positions: 60 Reagent positions: 40 Prefilled and validated system reagents 2 kit sizes per assay available Open channels: 3 Low water consumption (< 3 l/h) Intuitive and powerful software Multi-language: English, Spanish, French Intuitive and powerful software > Full traceability to reagents (e.g. lot & bottle), calibrations, users and settings > Searchable result database > Onboard and calibration stability monitoring > Automatic outlier detection and unit conversion > Method specific wash options > Designed for touchscreen Flexible system reagent concept > Plug & run HumaStar system reagents > Ready-to-use and available in two kit sizes > Usable for HumaStar 300SR and HumaStar 600 > Prefilled barcoded reagent bottles > Validated assay settings for highest quality > Up to 56 days reagent onboard stability > High quality reagents “Made in Germany” Eco-friendly ProClean 2.0 Technology > Minimal carry-over – dual solution wash station > Low water consumption – less than 3 l/h > Separation and reduction of biohazard waste Easy and efficient operation > Multi-step cuvette wash station for reaction cuvettes > Pre and post dilution for long walk-away time > Bottle cap holder prevents bottle mix-ups and saves time > Quick user- and service-friendly maintenance HUMAN‘s reagent production facility In Magdeburg, Germany we produce our reagents in accordance with the latest quality standards, guaranteeing consistent quality at the highest level. HUMAN Gesellschaft für Biochemica und Diagnostica mbH Max-Planck-Ring 21 · 65205 Wiesbaden · Germany Tel. +49 6122-9988-0 · Fax +49 6122-9988-100 · e-mail: human@human.de · www.human.de Immune Status anti-Streptolysin-O, Complement C3 and C4, CRP, Immunoglobulins IgA, IgG, IgM Liver Panel Albumin, Alkaline Phosphatase, Bilirubin Total and Direct, Cholinesterase, gamma-GT, GOT (ASAT), GPT (ALAT), Total Protein Kidney Panel Calcium, Creatinine, Cystatin-C, Inorganic Phosphorus, Magnesium, Microalbumin, Potassium, Sodium, Urea/BUN, Uric Acid, Urinary Total Protein Arteriosclerosis Cardiac Risk Assessment Cholesterol, HDL-/LDL-Cholesterol, Homocysteine, Triglycerides Anemia Iron, Total Iron Binding Capacity, Transferrin Pancreatic Tests alpha-Amylase, Lipase, Pancreatic Amylase Water & Electrolyte Balance Albumin, Chloride, Potassium, Sodium, Total Protein Cardiac Panel CK-NAC, CK-MB, GOT (ASAT), GPT (ALAT), Homocysteine, LDH Diabetes Glucose, HbA1c, Microalbumin, Triglycerides, Urinary Total Protein Prostata Acid Phosphatase HumaStar 300SR Broad range of clinical chemist

Send Message
product image
Hematology

Fully Automatic Oscar Om 511 Hematology Analyzer, For Clinical, User Input: Touch Instrument Name Haematology Analyzer Usage/Application All Automation Fully Automatic Brand OSCAR Parameters CBC + 5 Diff Differential Type 5-Part Number Of Chambers 2 User Input Touch / Manual Number Of Parameters ALL Parameters Instrument Type 5 PART Cell Counter Model Name/Number OM-511 Type Of Blood Analyzer Fully Automatic Sample Mode All Method All Throughput 60 Samples Per Hour Display Digital Features Catalogs Attached Sample Volume 15ul Storage 1 Lac Results No. Of Reagents Used 2 Lyse 1 Diluent Accessories Keyboard ,Mouse ,Tubing Set ,Power Adaptor, Print Roll Calibration Automatic / Manual Chamber Type Double Chamber Depth Of Chamber 100un Detector Yes Dilution Ratio 1.0 Loading Pattern Manual Measuring Method Electric Impedance & Cytometric Measuring Principle Electric Impedance & Cytometric Measuring Range 2 SD Measuring Time 52 Sec Number Of Reading Channels 2 Number Of Squares 4 Operating Voltage 220 Power Supply 220 Reagent System Close with RFID Sample Type Whole Blood Slide Size 0.3un Test Volume 15ul Wavelength 546 Weight 20 Kg Zero Setting Blank Aperture Size RBC 80 , WBC 100 , Plt 60 Is It Portable Yes Measurement Range Mm Hr 60 Test Per Hour Portable Yes Reading Chambers 2 Direct Sample Yes Optical System Wavelength Optical Source Flow cell Height 470mm Point Of Care Yes Dimension 365x470x525mm Printer Yes - Internal Humidity 88% Operational Ambient Temperature 37% Atmospheric Pressure 85 kpa User Interface Yes Reliable Yes Minimum Order Quantity 1 Product Description Company : OSCAR MEDICARE PVT LTD Brand : OM-511 CBC 5 Part Hematology Products Specification : The Brand New Autometed 5-Part Differentials hematology analyzer. Try-angular laser scatter + flow cytometry for 5 Part WBC Counting. Whole Blood, Peripheral Blood, Pre-diluted blood. Throughput with 60 Samples / hour. 29 Parameters (Include 4 research Parameters 3 Reagents with orignal QC & Carlibrators

Send Message
product image
Clinical Chemistry

EM 360 is a Fully Automated Clinical Chemistry Analyser which is time tested and proven technology. It is designed to provide the most demanding productivity, speed and operational ease. EM 360 with a throughput of 360 tests/hour offers flexibility in operation and rugged performance to win against high workload, tight deadlines, multiple tasks and complexity of testing. It yields high quality results for virtually any biochemistry test to deliver quick, efficient and consistent performance. Product Features: Automated, Discrete, Patient prioritized, Floor model Based on proven technology, Diffraction Grating Separate probes for Reagent R1 & R2 and dedicated probe for sample Low reading volume of 200 µl only Onboard cooling for reagents to enhance the reagent stability Barcode for reagents & samples (Optional) Wide test menu Product Applications: End Point Reactions: Glucose, Cholesterol, Triglycerides, Albumin, Total Protein, Uric Acid, Calcium, Magnesium, Bilirubin Total, Bilirubin Direct Kinetic Reactions: SGOT, SGPT, GGT, LDH, CK, CK MB, ALP, ACP, Amylase, Lipase Two Point Rate Reactions: Urea, Creatinine Immunoturbidimetric Chemistries: RA, CRP, ASO, Direct HDL, Direct LDL, Apo A, ApoB, Lp (a) Special Chemistries: HbA1c, Iron, Ferritin, Phosphorus, Microprotein, Ammonia, Bicarbonates System Type: Discrete, automated, random access, patient prioritized clinical chemistry analyzer Throughput: 360 tests / hour photometric and 600 tests / hour with ISE* (*optional ISE with Na+, K+, Cl-, Li+) Analytical Methods: 1-Point, 2-Point, Rate-A, Rate-B, Direct Potentiometry (optional) Barcode Reader: For reagents and samples (optional) Reaction Tray: 60 hard glass cuvettes Reaction Mixing: Stirrer with variable speed Minimum reaction Volume: 150 μl with maximum 200 μl reading volume On-board Laundry: 5 stage cleaning, 2 stage drying Photometer: Multi-wavelength diffraction grating with 12 wavelengths (340, 376, 415, 450, 480, 505, 546, 570, 600, 660, 700, 750 nm) OD Range: 0.0 - 3.0 Light Source: Halogen lamp Detector: Silicon photo-diode Water Consumption: < 10 litres Programmable Parameters: Default system pack parameters + upto 99 user defined parameters, Unlimited profile and unlimited calculation items Quality Control: QC plot data with QC rules. Provision for lab mean. Twin plot Calibration: K-Factor, Linear (1, 2 point & multipoint), 4P and 5P Logit-log, cubic spline, exponential, polynomial, On-board serial dilution for calibrator Power Requirement: AC 220 V ± 10 %, 50 Hz or AC 110 V ± 10 %, 60 Hz Power Consumption: 800 VA Dimension (mm): Approx. 675 (W) x 840 (D) x 1120 (H) Weight: Approx. 150 kgs. SAMPLE HANDLING Sample: Serum, Plasma, Urine, CSF, Whole blood, other Sample Unit: 82 positions for samples, blank , controls, calibrators, STAT sample Sample Pipetting: 2 - 70 µl (adjustable in 0.1 µl step) for Biochemistry, 70 µl fixed for ISE Capacitance probe with liquid level sensing & vertical obstruction detection, serum indices Auto Rerun: Repeat with same, increased or decreased volume ( upto 1:150) Sample Tubes /Cups: Primary tubes of 5 ml, 7 ml, 10 ml and sample cups REAGENT HANDLING Reagent Tray: 50 positions for reagents with onboard cooling Reagent Pipetting: R1: 50 - 300 µl (adjustable in 1 µl step) R2: 10 - 200 µl (adjustable in 1 µl step) Capacitance probe with level sensing & vertical obstruction detection SYSTEM INTERFACE: Analyzer-PC: USB PC - Host Computer: Bidirectional TCP / IP & RS - 232 PC - Printer: USB Operating System: Windows Based Database: Unlimited Results

Send Message

Still searching for
operational biohazard?