Jaipur
+918529833535

'operating environment temperature'

Items tagged with 'operating environment temperature'

product image
Urinalysis Analyzer

The AUTION ELEVEN AE-4020 is intended for the qualitative and/or semi-quantitative measurement of several physiological markers in urine: Glucose, Protein, Bilirubin, pH, Blood, Urobilinogen, Ketones, Nitrite, Leukocytes, Creatinine, Albumin, Specific Gravity, P/C (Ratio of Protein to Creatinine) and A/C (Ratio of Albumin to Creatinine). These measurements are used for screening of kidney disease, liver disease, diabetes mellitus and urinary tract infection in general screening populations. Compact Design: 210(W) x 328(D) x 164(H) mm / Approx. 3.6 kg Processing speed: 514 samples per hour (maximum processing mode: 7 second interval) Auto-start function: Measurement starts automatically when a strip is set on the tray. Test strip can be placed either from the left or the right side. Maximum 11 parameters and color tone can be measured simultaneously by special test strips designed and made by ARKRAY. *Some products including test strips may not be available in all countries. Please check with your local Arkray representative or distributor about product availability in your area. Sample Urine Test Strip / Reagent pack AUTION Sticks / Uriflet S / AUTION SCREEN Measurement item GLU, KET, BIL, NIT, PRO, URO, pH, BLD, LEU, ALB, CRE, Specific Gravity, color tone Measurement range Test strip: As Rank table Color tone: As Color tone classification chart Measurement method Test strip method Dual-wavelength reflection photometric method (single wavelength for BLD) Measurement wavelength 4-wavelength LED (430, 565, 635, and 760 nm) Test strip reaction time 60 seconds Processing speed 514 samples per hour (maximum processing mode: 7-second interval) Display Custom LC display (icons are used) Built-in printer 32-digit thermal printer (58 mm width) External output Conforms to RS-232C standard (serial) Option: Ethernet Memory capacity 520 measurement results Temperature correction Auto-correction by the internal temperature sensor (between 10 to 30 °C) S. G. correction Auto-correction by pH values Chromaturia correction Auto-correction by the color tone correction section on test strips Operating environment Temperature: 10 to 30 °C; Humidity: 20 to 80% R.H. (non-condensing) Measurement environment Temperature: 10 to 30°C; Humidity: 30 to 60% R.H. (non-condensing) *Temperature correction function used DC power requirements(To instrument) 12 Vdc 3 A AC power requirements(To AC adapter) 100-240 Vac 50-60 HZ ,1200 mA Voltage fluctuation allowance is ±10% Power consumption Max. 45 VA Dimensions 210 (width) × 328 (depth) × 164 (height) mm Weight Approx. 3.6 kg

Send Message
product image
Urinalysis Analyzer

High Performance "Full Automated System" Color Touch Panel for good usability 7 inch WVGA color touchscreen with high operability displays measurement results, instrument conditions and operating instructions. "Sample delivery system" enables micro volume samples to be measured As the sample is drawn through the nozzle and delivered correctly and quantitatively to each pad of the strip, the micro volume samples (minimum 1mL) can be measured easily. No cross contaminations are found on the reagent portions despite high sample volume. Sample Urine Test items Glu, Pro, Bil, Uro, Ket, pH, Nit, Bld, Leu, S.G., Alb, Cre(Alb/Cre ratio, Pro/Cre ratio can be calculated), turbidity and color tone Wavelength 5 LED wavelengths (430, 500, 565, 635, 760nm) Measurement principle Test strip :Dual-wavelength reflectance method (One-wavelength for Bld) Specific gravity :Reflection refractometryColor hue :Light-transmission measurementTurbidity :Light-scattering measurement method Test strip AUTION Sticks (10EA & 10PA) , Uriflet S 11UA Reaction time Approximately 60 seconds Throughput 225 samples per hour Strip storage Maximum 400 strips (200 strips x 2 feeder boxes) Required sample volume Normal, STAT measurement: Minimum 2 mL Small volume measurement: Minimum 1 mL Sample consumption Normal, STAT measurement: Maximum 0.90 mL Small volume measurement: Maximum 0.45 mL Sample container Sample tubes (length: 95 - 110 mm, diameter: ø14.0 - 15.8 mm) Maximum sample load 100 samples (Circulation) Data memory Normal, STAT, small volume measurement: 2500 tests Control measurement: 200 tests Check measurement: 50 tests Trouble list: 100 tests Display Large color liquid crystal display (800 × 480 dots) Built-in printer 58-mm width printer paper (24 digits) External output 1 port (Replaceable with the optional Ethernet terminal) Communication method RS-232C compliant (Switchable between one-way and two-way) Measurement environment Temperature: 10 - 30°C; Humidity: 30 - 60% RH (No condensation) Power requirements 100 - 240 V AC (Maximum power line fluctuation of ±10%), 50/60 Hz Power consumption 150VA (Maximum) Dimensions 530 (W) × 530 (D) × 550 (H) mm (including the sampler) Weight Main body: Approximately 36 kg Sampler: Approximately 4 kg

Send Message
product image
Laboratory Testing Analyzer

For smaller Laboratories Smaller, but with full functionality Compact size Full functions and performance in a compact size. *Size comparison with HA-8180V Accuracy HPLC technology provides accurate results-inluding detailed chromatogram. it will be shown in both IFCC and NGSP units. Cap-piercing method ADAMS Lite uses a cap-piercing method which enables the placement of capped blood samples. This not only reduces the workload but also helps protect lab technicians from infection. Easy-to-maintain No special tools are required for daily maintenance. Exchanged parts are hand-tightened, minimizing the workload of users. Specifications Measurement objects Whole blood or hemolysis sample Measured items Fast Mode: HbA1c (Stable HbA1c, S-A1c) and HbF Variant Mode: HbA1c (Stable HbA1c, S-A1c) and HbF (HbS and HbC separation and HbE and HbD detection can be performed). Measurement principle Reversed-phase cation exchange chromatography Measurement wavelength 420 nm/500 nm (Dual-wavelength colorimetry) Resolution 0.1% Ratio, 1 mmol/mol Measurement range HbA1c: 3 - 20%, 9 - 195 mmol/mol HbF: 0 - 100% Processing speed Variant mode: 160 seconds/test Fast mode: 100 seconds/test Sample consumption Whole blood sample: Approximately 4µL Anemia sample: Approximately 8 µL Hemolysis sample: Approximately 350 µL Sample container Sample tube: (12.3 or 15 mm in outer diameter) × (75 to 100 mm in height) Sample cup: 500 µL Sample supply Piercing sampling Compatible rack type ARKRAY racks (for 5 samples) Operating environment Temperature: 10 - 30°C; Humidity: 20 - 80% RH (No condensation) Display 20 digits × 2 lines LCD Printer For use with 58-mm width thermal printer paper Number of measurement samples Maximum 10 samples Power requirements AC 100 - 240 V±10%, 50/60 Hz Dimensions 330 (W) × 515 (D) × 485 (H) mm (Not including protrusions, eluent packs and hemolysis washing solution bottle)

Send Message
product image
Clinical Chemistry

Find the Best Semi Automatic Biochemistry Analyzer from Accurex. Buy Acculab At 112 Plus (Semi Auto Biochemistry Analyzer) which is the best Biochemistry Machine with numerous features like Filter Check, Self-check operation for optical filters, Checks the absorbance of each of the 7 filters & free position, Ensures that all the filters are in good working condition. This Biochemistry Analyzer has Improved ergonomic touch screen display, ensures strain free viewing with End point, kinetic, fixed time & absorbance mode. FILTER CHECK • Self-check operation for optical filters. • Checks the absorbance of each of the 7 filters & free position. • Ensures that all the filters are in good working condition. WORKLIST • A unique facility by which a worklist can be prepared for every sample ID. • Printouts can be taken by sample ID or test parameters. • Print by ID : Ensures that no test is left out for a particular ID. • Print by Test : Ensures that all reagents / working solutions are prepared in correct volumes preventing wastage. • The system flags any test which is missed out for a particular ID, ensuring all assay panel is completed. LAMP SAVING • Lamp saving option available ensuring long lamp life. • The lamp can be turned off in case of sporadic sample workload ALARMS • Audio alarm is sounded when results are higher (S) or lower (L) than reference range ensuring that all abnormal samples are flagged for further review. • Improved ergonomic touch screen display, ensures strain free viewing • End point, kinetic, fixed time & absorbance mode • Single & bichromatic measurement • Memory : 3200 results • 112 programmable channels • Calibration modes – 1 standard / multi-point linear / multi-point non-linear • Easy-access maintenance chamber ensures efficient uptime management • Real-time reaction curve display • Anti-vibration & anti-disturbance optical system ensures highly accurate results • Option of 7 filters (340 – 630 nm) & 1 free position • Comprehensive quality control program with L-J graph • Lamp saving feature to prolong lamp life • Audible / visual alarm available • Easy-tear printer design Methodology: End point, kinetic, fixed time & absorbance Calibration: Single standard/multi-point linear/multi-point non-linear Programmable channels: 112 Memory: 3200 results Quality control: Comprehensive QC software with L-J graph Light source:Quartz-Halogen lamp 12V / 20W Photometric range: 0.0000 to 3.0000 Abs, Resolution : 0.0001 Abs : Drift : 0.002 Abs/hour Wavelength range: 7 standard filters: 340, 405, 492, 510, 546, 578, 630 nm & 1 free optional position ; Half Bandwidth < 8 nm : Stray light : < 1.0 % at 340 nm, Stainless steel body with quartz window; Optical path 10 mm Flowcell: Stainless steel body with quartz window; Optical path 10 mm Measuring volume: 32 μl Programmable aspiration volume:: 500-2000 μl Temperature control: Peltier elements : 25°C, 30°C & 37°C ±0.1°C Input: Ergonomic LCD touch screen display Printer: Built-in high speed thermal printer Interface: RS-232 serial port Dimension / Weight: 450 x 360 x 140 mm / 11.5 kgs Operating environment: Temperature: 15-30°C ; Humidity: 20-80 % Power requirement: AC 110-220 V ±10%, 50/60 Hz Safety Information • The position of the LCD display has been designed to reduce cervical (neck muscle) strain during continual use. • The aerial view display design makes it possible to view the screen from multiple perspectives, (standing or sitting, with equal clarity). Direction for Use • A unique facility by which a worklist can be prepared for every sample ID. • Printouts can be taken by sample ID or test parameters. • Print by ID : Ensures that no test is left out for a particular ID. • Print by Test : Ensures that all reagents / working solutions are prepared in correct volumes preventing wastage. • The system flags any test which is missed out for a particular ID, ensuring all assay panel is completed. Other Info • Improved ergonomic touch screen display, ensures strain free viewing • End point, kinetic, fixed time & absorbance mode • Single & bichromatic measurement • Memory : 3200 results • 112 programmable channels • Calibration modes – 1 standard / multi-point linear / multi-point non-linear • Easy-access maintenance chamber ensures efficient uptime management • Real-time reaction curve display • Anti-vibration & anti-disturbance optical system ensures highly accurate results • Option of 7 filters (340 – 630 nm) & 1 free position • Comprehensive quality control program with L-J graph • Lamp saving feature to prolong lamp life • Audible / visual alarm available • Easy-tear printer design

Send Message
product image
Hemoglobin Meter

Buy Accurex H12 Hemoglobin Test Strips Online – for better result & accuracy. These Hemoglobin strips are used with URIT Hemoglobin Meter, for the quantitative measurement of total hemoglobin in capillary and venous whole blood. These hb strips are to be used by health care professionals only, not to be used for patient self-testing. Accurex HB Test Strips come with a pack size of 50 strips. The Accrues test strip utilizes Dry Chemistry Colorimeter Method (Azido methemoglobin Method). Meter’s optical detectors automatically measure the change in the membrane Buy Accurex H12 Hemoglobin Test Strips Online – for better result & accuracy. These Hemoglobin strips are used with URIT Hemoglobin Meter, for the quantitative measurement of total hemoglobin in capillary and venous whole blood. These hb strips are to be used by health care professionals only, not to be used for patient self-testing. Accurex HB Test Strips come with a pack size of 50 strips. The Accrues test strip utilizes Dry Chemistry Colorimeter Method (Azido methemoglobin Method). Meter’s optical detectors automatically measure the change in the membrane Operation Principle: The test strip utilizes Dry Chemistry Colorimeter Method (Azido methaemoglobin Method). When a drop of whole blood is applied to the test spot on the strip, blood immediately disperses within the membrane, contacting the reagent. The meter’s optical detectors avtomatically measure the change in membrane reflectance. The intensity of reflectance is inversely proportional to the hemoglobin concentration. Blood Sample Collection: Fresh or EDTA-anticoagulated capillary or venous whole blood may be used. If an EDTA – treated sample is refrigeratted to come to the room temperature before testing. EDTA treated blood samples should be mixed using end to and inversions at least 8 times prior to use, and should be tested within 24nours Do not use the haemolytic sample anticogulants other than EDTA are not recommended for use. Caution: 1. Same as all diagnostic tests, hemoglobin test results should be evaluated with the specific patient’s condition. Any results demonstrating the inconsistency with the patient’s clinical status should be repeated or supplemented with additional test data. 2. Do not touch the test membrane by hand 3. H12 Hemoglobin Test Strips are one-off product, do not use again Storage & Preparation: 1.H12 Hemoglobin Test Strips should be stored at O C-30 C dry and dark places, 2 C – B C is the best storage environment emperatures recommended. Keep away from direct sunlight and heat, must not be frozen, If the container was stored in refrigerated before first use, please don’t take it back into the refrigerator again after first use. 2. H12 Hemoglobin Test Strips are ready to use. No additional preparation is required 3. Enclosed desiccants with lest strip. Remove only those strips needed for testing. The remaining lest strips should be resealed in their onginal container and used up in 3 months after first use. Do not use lest strips and throw away alter expiry date. 4. Use the strip immediately once taking it out af the container, otherwise the result will be incorrect 5. Do not fold or cut the test strip. 6. Used lest strips cannot be used again, dispose them as normal medical waste Direction for Use Operating Instructions: 1. URIT Hemoglobin Meter, H12 Hemoglobin Test Strip, Lancing Device, and disposable blood taking needle. 2. Test steps: 1) Turn the meter on and input the Code Card. Check the Code Card displaying on the meter to ensure it to match the Code Card printed on the lest strip container. Otherwise, the result is incorrect. 2) Massage the patient’s finger from the knuckle up to the tip to stimulate blood flow. Clean the sample area with alcohol and wipe it dry with a sterile gauze pad. 3) Insert the lest strip into the strip holder with the notched end in first and the hole facing up. 4) Puncture the skin on the lower side of fingertip with blood collection needle, and remove 13-15 TIL of whole biood with capillary or other micro blood collection apparatus. While waiting for the instrument to display the blood drop symbol, quickly add the drops to the test hole on the reagent sheet. Please make sure that the blood drop volume can completely cover the test hole but not overflow the test hole. 5) The meter starts the test automatically after the blood sample disperses Once the lest is in process do nol disturb or move the meter or test strip, or press any key. The test result will display within 12 seconds. Qualtiy Control Procedure: Use only H12 Hemoglobin Test Strip with QC substance to perform QC. The range of QC substance is the numerical range indicated on the label of the QCsubstance or test strips. When to do a QCtest: 1. Whenever you suspect that the meter or test strips are not working properly. 2. If your hemoglobin test results are not consistent with how you feel. Other Info Limitations of test Method: H12 Hemoglobin Test Strip is only suitable for testing fresh or whole capillary blood or whole venous blood containing EDTA anticoagulants. Do not use serum, plasma or arterial blood

Send Message
product image
Hematology

Buy the Best Automated Hematology Analyzers – Acculab CBC 360 Neo. This Hematology Analyser Machine is Truly Automated for self-checking, background test, calibration, sampling, dilution, mixing, printing, dormancy, alarms, cleaning and maintenance. CBC 360 Neo is 3 part hematology analyzer from Accurex & is Automated for Walk-away Operations. Dual Chamber: Measurement of RBC / platelets & WBC / HGB in different chambers ensure accurate counting in a short time. The micro-aperture sizes of both the chambers are well designed to avoid error due to cell misclassification Automation for Walk-away Operation: Auto Self-check : Automatic aspiration of reagents & rinsing of tubings on startup Auto Blank : Background test is run automatically on startup Auto Print : Automatic printing of report with / without histogram Auto Sleep : Dormancy status is entered after a set period of non-operation Auto Alarms : Audio / visual alarms in case of system errors & abnormal results Auto Clean : Automatic rinsing options available to maintain the system Dual Chamber: Measurement of RBC / platelets & WBC / HGB in different chambers ensure accurate counting in a short time. The micro-aperture sizes of both the chambers are well designed to avoid error due to cell misclassification Specifications: Measurement principle: Electrical resistance for counting RBC, WBC & Platelets Colorimetric estimation of HGB at 540 nm Parameters: WBC, LY, MO, GR, LY%, MO%, GR%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR Throughput: 60 samples/hour Micro-aperture: WBC : 100 um RBC / PLT : 68 um Sample type: Whole blood or pre-diluted sample Sample volume: Whole blood (venous blood) : 10 ul Chamber: Pre-diluent (capillary blood) : 20 ul, Pre-diluent (capillary blood) : 20 ul Reagents: Dual chamber : RBC / Platelets & WBC / HGB Quality control: 4 QC options : L-J, X-B, X-R & X QC, Graphs plotted with 31 data points Data memory: Upto 100,000 (with histogram) Display: 10.4 inch LCD with 640 x 480 resolution Printer: Built-in thermal printer Interface: Support RS-232C, standard network port and USB; keyboard and mouse Operating environment: Temperature : 15˚C – 35˚C, Humidity : 85% RH Electrical specification: Voltage : AC 110V/230V 23V Frequency : 50/60 Hz, Power : 180W Fuse specification : 250V/3A Dimensions / Weight: 670 x 515 x 640 mm / 27.5 kgs Specification Acculab CBC 360 Neo – Fully Automated Hematology Analyzer Features: 3-part differentiation of WBC Automated for — self-checking, background test, calibration, sampling, dilution, mixing, printing, dormancy, alarms, cleaning and maintenance High processing speed : 60 samples/hour Multi-parameter estimation : 20 parameters categorized according to corpuscle type for easy reporting Direct command keys for Mode, Prime, Flush, Drain & Record / Print for faster operation Run / Standby indicator lights denote the analyzer status i.e. test is being run or analyser is ready to test Whole blood/ Pre-diluent indicator lights denote the sample type in use i.e. whole blood/ pre-diluent Dual sample mode with low sample volume: Whole blood (venous) mode : 10 ul; pre-diluent (capillary) mode : 20 ul Audio alarm indication for abnormal findings or system errors 4 QC methods : L-J, X-B, X-R & X QC Comprehensive QC graphs with 31 data points for each parameter Internal & external probe cleaning facility Dormancy mode available to reduce power consumption Memory : 100,000 (with histogram) Safety Information • Large 10.4 inch single screen color display of all 21 parameters and 3 histograms • Sequential arrangement of WBC, RBC & PLT parameters for convenient reporing •Easy to understand & icon-based arrangement of menu for fast and convenient testing Direction for Use • WBC Histogram: R1, R2, R3, R4 & RM indications on histogram show specific abnormalities in the histogram & the probable causes • Platelet Histogram: PM indication is given when the boundary between PLT & RBC is ill-defined thus avoiding misclassification Other Info High voltage cautery function is useful in disintegrating obstinate protein or serum clog in the tubing

Send Message
product image
Immunology Analyzer

Product Description: Erba Lisa Wash II is a simple easy to Operate and use ELISA Plate Washer, Suitable for all ELISA applications. Programmable features like, dispense pressure, Single/double aspiration, Horizontal & Vertical adjustments ensures complete control on washing efficiency Product Features: Fully automated, easy operating system and friendly software with large-screen display 50 user programmable protocols to customize washing Easily removable 8- or 12-way manifolds Liquid level detection and alert function Low residual volume: <3 µl Soak time programmable up to 24 hrs. Compatible for flat-bottom, U and V bottom type microplates or microstrip High-efficiency ELISA washing with automated monitoring of Vacuum. Choice of 2 wash buffer bottles, 1 distilled water & 1 waste container with sensor Dispense pressure and the volume adjustable, so as to reduce the air bubbles and ensure thorough Washing Waste-bottle sensor to detect high-waste liquid levels Standard aerosol protection cover Easy maintenance CE marked Product Applications: ELISA Wash Head: 8 and 12 head manifold compatible Wash Mode: Row and Plate Wash Row: 1-12 rows Flat Bottom Plate Type: 96 or 48 well plate or strip (Flat, U & V - bottom) Wash Programs: 50 Moving Cycle: up to 12 cycles Dispensing Volume: 50 - 3000μl in 50μl increments Dispensing Precision: < 2% at 350μl Prime Volume: 50 - 1000μl Aspiration Pressure: Automatic Soak Time: 0 – 24 Hrs Residual Volume: ≤ 2μl for V/ U bottom plates, and ≤ 3μl for per well Flat bottom plates Nos. of Bottles: 2 wash, 1 Rinse/DI, 1 waste with level sensor, 2L each User Interface: 5 Inch LCD (90 x 53 mm), with Keypad Bottle Capacity: > 2 L Operating Environment Power Supply: AC 220 V/ 110 V, 50/60 Hz Input Power : < 80VA Operating Temperature: 10°C - 30°C Relative Humidity: Up to 95% relative humidity without condensation Storage Temperature: -10°C - 40°C Weight: 9.5 Kg Dimension: 710 mm x 530 mm x 380 mm

Send Message
product image
Hemostasis Analyzer

Product Description: It’s a modern and advanced analyzer in Hemostasis. This single channel coagulation analyzer redefines the benefits in its class Erba. ECL 105 can perform PT, APTT, Fibrinogen, Thrombin Time, All Factiors, Lupus and DDimer. Product Features: Clotting Tests such as PT, aPTT, Fibrinogen, Thrombin time, Factors, Lupus anticoagulant performed using Light scatter principle Tests like D Dimer performed using Immuno-turbidimetry principle Interactive touch screen interface Clotting Graph provides details of the clotting testCuvette and reagent management software Twelve levels of QC with Levy-Jennings Plot- Identifies random and systematic errors Temperature stability at 37 degree C to perform the tests. Low Reagent Consumption USB Connectivity CE mark Product Applications: ECL 105 has uses in various routine IVD labs for doing routine PT and aPTT It has application in Blood Banks for Quality Control of Fibrinogen and Factor VIII It is used as Standby to bigger systems, in accredited centres It is used in Research Facilities to perform PT and aPTT on animal samples such as rat, mouse, rabbit, hamsters etc Key Specifications: Single channel semi-automated hemostasis system It can analyze 1 test at a time Sample id can be 14 digits alphanumeric, with progressive id or custom id options It is also possible to have a second position of assay preparation/incubation during the analysis of the current one, using preparation line option Optically detects and automatically moves to the next assay steps and auto starts the measurements Tests principles: Clotting (scattered light at 640nm) Immuno-turbidimetric (turbidimetry at 800nm) Dimensions / Weight: Dimension : 216 x 205 x 75 mm Weight : ~1 kg Environmental requirements: Operating Temperature : 17-32°C Humidity: Max. 80% Relative Humidity, non-condensing Power: Power Supply : 100-240 VAC and 50/60 Hz Power Consumption : 45 Watts In-Rush Power : 150 VA or less Calibrations: Up to 6 calibration levels per assay Storage of the active calibration curve Quality Controls: Up to 12 different control total can be assigned to any given assay Automatic Levey-Jennings plotting Automatic statistics calculation Storage of Quality Control results Stored Results: Independent storage allocation in the instrument memory for Quality Control (QC) and patient determinations Up to 1000 results for QC determinations Up to 1000 results for patients New results automatically replace the oldest results of the appropriate category past the maximum storage allowance Reaction curves are exclusively stored on the external USB pen drive. Regular backup and file purging is recommended from the USB pen drive to insure rapid operations. USB pen drive, FAT32 formatted

Send Message
product image
Hemostasis Analyzer

Product Description: It’s an advanced analyzer for Complete Hemostasis. This four channel coagulation analyzer redefines the benefits in its class. Erba ECL 412, can perform PT, APTT, Fibrinogen, Thrombin Time , All Factors, Lupus , Protein S, Protein C , Antithrombin III and DDimer. Product Features: Clotting Tests such as PT, aPTT, Fibrinogen, Thrombin time, Factors, Lupus anticoagulant, Protein S performed using Light scatter principle. Protein C, Antithrombin III done by Chromogenic Principle Tests like D Dimer performed using Immuno-turbidimetry principle Interactive touch screen interface Clotting Graph provides details of the clotting test Cuvette and reagent management software Twelve levels of QC with Levy-Jennings Plot- Identifies random and systematic errors Temperature stability at 37 degree C to perform the tests Low Reagent Consumption USB Connectivity CE mark Product Applications: ECL 412 has uses in various routine IVD labs for doing routine PT and aPTT It has application in Blood Banks for Quality Control of Fibrinogen and Factor VIII It is used as Standby to bigger systems, in accredited centers It is used in Research Facilities to perform PT and aPTT on animal samples such as rat, mouse, rabbit, hamsters etc General Specifications: 4 channel semi-automated hemostasis instrument It can perform 4 simultaneous tests of the same parameter Sample id can be 14 digits alphanumeric, with progressive id or custom id options It is also possible to have a second row of assay preparation/incubation during the analysis of the current line, using preparation line option It can run assays in single or duplicate (programmable per assay) Optically detects and automatically moves to the next assay steps and auto starts the measurements Tests principles: Clotting (scattered light at 640nm) Chromogenic (colorimetry at 405nm) Immuno-turbidimetric (turbidimetry at 800nm) Dimensions / Weight: Dimension : 300 x 290 x 90 mm Weight : 3 kgs Environmental requirements: Operating Temperature : 17-32°C Humidity: Max. 80% Relative Humidity, non-condensing Power: Power Supply: 100-240 VAC and 50/60 Hz Power Consumption: 45 Watts In-Rush Power: 150VA or less Calibrations: Up to 6 calibration levels per assay Storage of the active calibration curve Quality Controls: Up to 12 different control names total can be assigned to any given assay Automatic Levey-Jennings plotting Automatic statistics calculation Storage of Quality Control results Stored results: Independent storage allocation in the instrument memory for Quality Control (QC) and patient determinations Up to 600 results for QC determinations (run in duplicate) Up to 900 results for patients (run in duplicate) New results automatically replace the oldest results of the appropriate category past the maximum storage allowance Reaction curves are exclusively stored on the external USB pendrive. Regular backup and file purging is recommended from the USB pendrive to insure rapid operations. (We recommend at least a monthly purge from a computer to back up and remove CH files) USB pendrive , FAT32 formatted

Send Message

Still searching for
operating environment temperature?