Jaipur
+918529833535

'open vial sampling'

Items tagged with 'open vial sampling'

product image
Hematology

At Mindray, we pride ourselves on our dedication and experience in developing better solutions for small labs. Our new 3-part hematology analyzer is the culmination of that effort. It provides small labs with more confidence in results and less turnaround time. Features CBC+3-DIFF, 20 parameters +3 Histograms Throughput: up to 30 samples per hour 8.4 inch TFT touch screen Only three reagents needed Open vial sampling Large storage capacity: up to 50,000 samples Original QC, calibrators and reagents Automation Fully Automatic Instrument Name Hematology Analyzer Brand Mindray Differential Type 2-Part Usage/Application Clinical Number Of Chambers 1 Model Name/Number BC-10 Power Source Electric Voltage 240 V Frequency 50 Hz

Send Message
product image
Hematology

At Mindray we pride ourselves on our dedication and experience in developing better solutions for small labs. Our new line of 3-part hematology analyzers is the culmination of that effort. Compact yet powerful, full featured yet affordable, the BC-20s is what a 3-part analyzer should be. Features CBC+3-DIFF, 19 parameters+3 histograms Throughput:40 samples per hour Intuitive operation system with 8.4 inch TFT touch screen Open vial sampling 200,000 results storage with histograms Original QC, calibrators and reagents Product Specification Instrument Name Haematology Analyzer Model Name/Number BC20s Usage/Application Laboratory Brand Mindray Automation Fully Automatic Operation Mode Fully Automatic

Send Message
product image
Hematology

At Mindray, we pride ourselves on our dedication and experience in developing better solutions for small labs. Our new 3-part hematology analyzer is the culmination of that effort. It provides small labs with more confidence in results and less turnaround time. Features CBC+3-DIFF, 21 parameters+3 Histograms Throughput: up to 60 samples per hour 10.4 inch TFT touch screen Only three reagents needed Open vial sampling Large storage capacity: up to 400,000 samples Original QC, calibrators and reagents Product Specification Automation Fully Automatic Instrument Name Hematology Analyzer Brand Mindray Usage/Application Clinical Differential Type 3-Part Number Of Chambers 2 Number Of Parameters LYM Model Name/Number BC-30s User Input Touch Voltage 240 V Frequency 50 Hz Power Source Electric

Send Message
product image
Clinical Chemistry

The ADVIA® 1800 Clinical Chemistry System pushes the limit of productivity. Its extensive menu allows integration of testing for clinical chemistry, drugs-of-abuse, therapeutic drug monitoring (TDM) and specific proteins such as cystatin C and CardioPhase® hsCRP. The ADVIA 1800 Clinical Chemistry System offers: Throughput of up to 1,800 tests per hour to keep pace with workload peaks 200 basic metabolic panels per hour to meet turnaround-time demands Large onboard reagent capacity and optional concentrated reagents to reduce interruptions Optimal standardization of reagents and systems for efficient consumable usage Refrigerated onboard storage of controls and reagents for extended stability and increased productivity Automation-ready design: no additional hardware required Features & Benefits The ADVIA 1800® Clinical Chemistry System pushes the limit of productivity in the core lab and meets the turnaround-time (TAT) goals of today’s laboratories. Its extensive menu allows integration of general clinical chemistry testing with testing for drugs-of-abuse, TDM, special chemistry, and specific proteins such as cystatin C and CardioPhase® hsCRP. Automation-ready design Point-in-space aspiration enables connectivity to a track, VersaCell® System. Redundant sample loading provides built-in backup and easy handling of non-routine samples. Direct sampling from track prevents tubes being detained at an analyzer and reduces aliquoting. Peak productivity Throughput of up to 1,800 tests per hour provides the speed to keep pace with workload peaks. Throughput of 200 basic metabolic panels per hour helps to meet turnaround-time demands. Automatic Sample Retain technology lets you perform reruns and dilutions without the need to retrieve primary tubes. Consolidate chemistry testing on one system with a comprehensive menu, consistent cycle times, speed, and open application capability. Total system reliability Minimal-maintenance ISEs Robust hardware and simplified software design, with automatic calibration validation and tracking Advances in reagent onboard stability, calibration frequency, interference reduction and assay linearity expansion Direct water connection Remote diagnostics and Inter-Laboratory Quality Control (ILQC) options Easy efficiency Large onboard reagent capacity and optional concentrated reagents reduce interruptions. High-resolution touchscreen delivers push-button operation. Reagent pause capability and onboard Sample Pause button make loading easy. Minimal maintenance requirements, including no-maintenance oil bath, reduce hands-on time. Sample integrity checking, include serum indices reporting, short-sample flagging, and clot detection, reducing the need for manual intervention.

Send Message
product image
Glucometer

Accu-Chek® Guide Blood Glucose Meter Surprisingly Clever Diabetes is complex. Your testing doesn’t have to be Item Description Diabetes is complex. Your testing doesn't have to be with the Accu-Chek® Guide blood glucose monitoring system. With a spill resistant SmartPack® vial, a strip that lets you place a small drop of blood anywhere along the end, and an app that automatically logs results to your phone, it's a surprisingly simple way to manage your diabetes. Benefits and Features Simple to log results without a paper logbook - automatically logs results right to a mySugr app on your smartphone Simple to take just one strip - spill-resistant SmartPack vial lets you take one and spill none Simple to dispose off used test strips - push-button strip ejector means you don't have to touch used strips Simple to see, day or night - strip port light for testing in daytime, nighttime or anytime Simple to be more accurate - delivers advanced 10/10 accuracy for reliable results you can trust1,2,3 Meter Specifications Models: Accu‑Chek Guide wireless blood glucose meter Serial number: Unique serial number etched into meter back Sample claims: Capillary: Yes Venous: ROW = Yes Arterial: ROW = Yes Non-fingerstick sample claim ROW: Palm, forearm, upper arm Measuring principle: FAD glucose dehydrogenase (GDH) Measuring time: Less than 4 seconds Measuring conditions: 4°C to 45 °C (39°F to 113 °F) Storage conditions: -25 °C to +70 °C (-13 °F to +158 °F) Hematocrit range: 10 to 65% Humidity range: 10 to 90 % Altitude independence: 0 to 3,094 m (10,150 ft) Memory capacity: Up to 720 measurements with date and time; 32 control measurements Test averages: 7, 14, 30 and 90 days Data transfer wireless connectivity: using Bluetooth Smart Low Energy Dimensions: 80 x 47 x 20 mm (L x W x H) Weight Approximately: 40 g with batteries Display: Large backlit LCD display with full-text capabilities Beep tone: Yes (factory setting ON) Batteries: (2) 3-volt lithium coin cell type CR2032 Auto power off: 15 seconds after removing a test strip; 90 seconds otherwise Blood volume: 0.6 μL Measuring range: 10 to 600 mg/dL Sample types: Capillary, venous, arterial and neonate Sample dosing: Capillary fill function; suitable for AST Test strip stability 18 months after production date: Test strips are stable (even after opening) until the expiry date printed on the test strip vial. Note: Test strip container must be tightly closed after each strip is removed. Storage temperature : 4 °C to 30 °C (39 °F to 86 °F)

Send Message
product image
Rapid Test

Buy AccuTest Vitamin D Rapid Card Test (10 Tests) Online from Accurex. The Vitamin D test kit consists of 25 AccuTest Vitamin D individually packed test, devices in foil pouches, 25 pipettes for collecting 10 ul of whole blood, 25 lancets, 1 Buffer Vial (Buffer 5 mL) with stabilizers and, thimerosal, 1 Package Insert. Vitamin D Fast test kit is a rapid chromatographic immunoassay for the semi quantitative detection of Vitamin D levels in human blood/serum. This Vitamin D test provides a preliminary screening test result. INTENDED USE AccuTest Vitamin D is a rapid chromatographic immunoassay for the semi quantitative detection of Vitamin D levels in human blood/serum. This assay provides only a preliminary screening test result. A more specific alternative chemical method must be used in order to obtain a confirmed analytical result. The performance characteristics of this assay have not been established in a pediatric population. PRINCIPLE AccuTest Vitamin D is based on the principle of a competitive enzyme immunoassay. The assay is based on the competition for 25-OH Vitamin D present in blood/serum sample and Vitamin D present on the test line for fixed number of antibody-gold conjugate. Depending upon the concentration of Vitamin D in blood/serum, there will be free antibody-gold conjugate molecules that will bind to Vitamin D on the test strip and will show a colored line in the test line zone. A control line is present in the test window to work as procedural control. PRECAUTIONS 1. For in vitro diagnostic use only. 2. The test is designed for use with human blood/serum only. 3. Reagents must be at room temperature (8⁰C – 30 ⁰C). 4. Do not use if test device packaging is open or damaged. 5. Do not use the product beyond expiration date. 6. Handle all specimens as potentially infectious. Proper handling and disposal methods should be used according to good laboratory practices. 7. Read test results for 10 minutes as required. Results may deteriorate and may not be consistent after 10 minutes. 8. In order to avoid variable results, mix the blood sample thoroughly. 9. A serum sample subjected to repeated freeze thaw cycles may give variable results Direction for Use PROCEDURE 1. Remove the cassette from the sealed pouch and place it on a hard flat surface with the view window facing up (use the cassette as soon as possible). 2. Using a micropipette, add 10 µl of whole blood or 5ul of serum sample directly into the rectangular specimen well (marked with Red drop) of the cassette. 3. Add 3 full drops of Buffer into the square buffer well of the cassette (Do not move the cassette after addition of buffer). 4. Let the cassette sit for 10 minutes and read your results immediately. Results may deteriorate after the 10 minute mark. Other Info STORAGE AND STABILITY The test device should be stored at 8 ⁰C – 30 ⁰C and will be stable until the expiration date stated on the package. The product is humidity sensitive and should be used immediately after being open. INTERPRETATION OF RESULTS Match the color of the test line with the chart provided.

Send Message
product image
Glycohemoglobin Analysis

Buy Xpress Glucometer Plus Kit Online, it’s a smart Glucometer Machine kit. This Digital Glucometer consists of 1 Blood Glucose Meter, 10 Test Strips, 1 Multilet Lancing Device, 10 Sterile Lancets, 1 Carry Pouch, 1 Warranty Card, Test Strip Insert Sheet, 1 Battery (3V) Gluco Plus Meter is intended for use in the home & in clinical settings. There are different types of Glucometers in Point of Care (POC). XPRESSGLUCO + meter measures the strength of the electrical current, calculates your blood glucose level and then displays your result in either milligrams of glucose per deciliter (mg/dL) or millimoles of glucose per liter (mmol/L). The system is intended for use outside the body (in vitro diagnostic use only). It should be used only for self-testing blood glucose (blood sugar) and only with fresh capillary whole blood samples drawn from the fingertips, forearm, upper arm, palm, calf or thigh. The system is intended for use in the home and in clinical settings. The system should not be used for the diagnosis of diabetes or for the testing of newborns. Blood glucose is measured by an electrical current that is produced when a blood samples mixes with the reagent (special chemicals) of the test strip. The electrical current changes with the amount of glucose in the blood sample. The XPRESSGLUCO+ meter measures the strength of the electrical current, calculates your blood glucose level and then displays your result in either milligrams of glucose per deciliter (mg/dL) or millimoles of glucose per liter (mmol/L). Safety Information 1. The user should not take any decision of medical relevance without first consulting his or her medical practitioner. 2. Call your doctor immediately if you experience symptoms that are not consistent with your blood glucose test results. 3. High altitudes above than 3,402 meter (11,161 ft) may affect the test results. 4. Temperatures outside the range of 10°C to 40°C (50°F to 104°F) may affect the test results. Do not test beyond of temperature range. 5. Do not perform servicing and maintenance while the meter is in use. 6. No modification of this equipment is allowed. 7. Do not use this meter near cellular or cordless telephones in a call, walkie-talkies, garage door openers, radio transmitters, or other electrical or electronic equipment that are sources of electromagnetic, radiation, as these may interfere with the proper operation of the meter. Direction for Use 1. Wash you hands and puncture sit: Wash your hands in warm, soapy water. Rinse and dry completely . Warm your fingers to increase blood flow. 2. Insert Test Strip : Remove a new test strip from vial. Be sure to tightly replace vial cap after removing test strips. Insert a test strip with the contact bar end entering into the test strip slot first. Push the test strip as far as it will go without bending it. The meter turns on automatically. 3. Hold the prepared lancing device firmly against the side of your fingertip. Press the release button. (NOTE : If you want to do alternative site testing, please refer to the “About Alternative Site Testing (AST)” section. Please consult your healthcare professional before obtaining blood from site other than your fingertip.) 4. Obtain a Blood Sample : Gently massage your finger or puncture site to obtain the required blood volume. To perform the test, you need only 0.5 μL of blood sample. Do not smear the blood sample. To obtain best accurate result, wipe off the first drop of blood and gently squeeze another drop of blood. 5. Apply Blood Sample : When the meter shows the “ ” symbol, apply blood to the opening of the absorbent channel of the test strip where it meets the narrow channel. Blood will be drawn into the test strip. If the test strip confirmation window is full, you will hear a beep. 6. Read Your Result : After the meter counts down from 5 to 1, your blood glucose test result appears along with the unit of measure, date and time. Test result is lower than the target range Test result is within the target range. Test result is higher than the target range *The default target range is 70 mg/dl to 180 mg/dl. 7. Turn Off the Meter : This blood glucose result is automatically stored in the meter memory. Turn the meter off by removing the test strip. Discard the used test strip carefully to avoid contamination. 8. After use, twist off the Lancing Device Cap. Push the exposed tip of the lancet into its Protective Cap. 9. Slide the Lancet Ejector forward and disposing the used lancet in an approved container. Discard the used lancet according to your country’s safety regulations. Replace the Lancing Device Cap. Other Info •Use only XPRESSGLUCO+ Control Solution with your XPRESSGLUCO+ meter. •Check the expiration date on the bottle. Do not use if expired. •Use within a period of 90 days from the date that you first open it. Record the discard date on the control solution bottle when you first open it to serve as a reminder to discard after 90 days. •The control solution ranges are printed on the label of the XPRESSGLUCO+ Blood Glucose Test Strip vial. They are not recommended target ranges for your blood glucose. •For in vitro diagnostic use. •Do not add any liquid to the XPRESSGLUCO+ Control Solution. •Do not take internally or inject.

Send Message
product image
Glycohemoglobin Analysis

Xpress A1c strips are used for a testing of quantitative determination of glycated hemoglobin(HBA1c) in human whole blood. It is used to monitor metabolic control in diabetic patients. it helps in diagnosis of the diabetes or pre-diabetes in adults. Buy Xpress A1c strips online (Pack of 25 Strips) – the best a1c test strips from Point of Care (POC) Range of Accurex HbA1c strips works as both a pipette and measuring element. A Blood drop of 8uL is needed for measurement. This blood is drawn into the cavity by capillary action. It helps users to understand their diabetes control status or to monitor their risk of developing diabetes. The Xpress A1c strips works as both a pipette and measuring element. A Blood drop of 8uL is needed for measurement. This blood is drawn into the cavity by capillary action. The Xpress A1c strips then needs to be inserted into Xpress A1c meter for hemoglobin measurement, The Xpress A1c meter measures the absorbance of whole blood at Hb isosbestic point. Xpress A1c meter uses two wavelengths of light to calculate Hemoglobin level, user level calibration is not required. How to use: Step 1: Wash hands using soap and warm water. Rinse and dry thoroughly. Step 2: Turn on the meter by pressing-releasing the power button. Step 3: Remove an Xpress A1c strip from the vial. Step 4: Prick a finger to obtain a blood sample. Step 5: Touch and hold the drop of blood to the pointed edge of the Xpress A1c strip. The blood is drawn into the Xpress A1c strip by capillary action Step 6: Once the blood fills the Xpress A1c strip chamber. Insert the Xpress A1c strip into the Xpress A1c meter. Step 7: Your Hemoglobin result will appear on the display window. Step 8: Remove the Xpress A1c strip from the meter and discard it. The meter will automatically turn off or long-press the power button to turn off. The Xpress A1c strips are used to quantitatively measure the concentration of HbA1C in whole blood, suitable for the self-monitoring of HbA1C for diabetes patients. It helps users to understand their diabetes control status or to monitor their risk of developing diabetes. is used to quantitatively measure the concentration of HbA1C in whole blood, suitable for the self-monitoring of HbA1C for diabetes patients. It helps users to understand their diabetes control status or to monitor their risk of developing diabetes.Features: Sample Type: Whole Blood/EDTA Blood/Capillary Blood Measuring Range: 0 to 25 g/dl Temperature: 0°C-50°C Storage Temperature: Room Temperature Expiry: Long Expiry(min 02 yrs) Pack Size: 25 Test/Vial LIMITATION AND WARNING: 1. This product is used for In Vitro Diagnostics only, not for in vivo use. 2. This product should not be used past the expiration date. 3. If there is evidence of microbial contamination or browning, discard the vial. 4. This product is not intended to be used as an HbA1c standard. 5. Preservatives contained in the control, rinse with water if splash into the mouth or eyes, and seek medical help as soon as possible. 6. Potential biological risk. Direction for Use This product should be run in accordance with instructions accompanying BioHermes Glycohemoglobin Test Kit and Glycohemoglobin Analyzer. (1) Dissolution: Open the cap of the vial, and then add 2 drops of Buffer A. Close the cap, and slightly shake the vial until the powder dissolved completely. And please shake it well before using it. (2) Testing in accordance with instructions accompanying BioHermes Glycohemoglobin Test Kit and Glycohemoglobin Analyzer. Please refer to the B Storage: 1. This product will be stable for 24 months when stored tightly capped at 2-8℃. 2. After dissolved, the product can be stable for 8 hours at 10-30℃, or 5 days at 2-8℃. Do not freeze it. COMPOSITION: This product is prepared from human blood and contains normal hemoglobin, preservatives and stabilizers. The control is provided in lyophilized powder form for increased stability. The kit contains two levels of control, level 1 is with yellow cap, and level 2 is with green cap.

Send Message
product image
Glycohemoglobin Analysis

Accurex Xpress A1c Glycohemoglobin Analysis System Kit . The Kit contains HbA1c Meter, 1 Sampler, 1 box of 25 test strips, Buffer A, Buffer B. Glycohemoglobin Analyzer It is used for testing glycohemoglobin concentration as an aid to monitor the risk of developing diabetes & control the status of diabetes. Buy Xpress A1c Meter Kit Online from Accurex Point of Care (POC ) Range – The HbA1c analyzer is specifically designed to be used with the corresponding test strip. HbA1c analyzer Hemoglobin A1C is a common blood test that measures blood glucose levels over the past two to three months. •Glycohemoglobin Analyzer •Handheld HbA1c Meter •Battery Operated •No Pipetting, No Lysing •Lab like Accuracy •Battery Operated •Truly Portable •Voice prompt for •User Guidance • Accurate result with cv <3% •Lab like accuracy with 95% •No interference of HB Variant •No pipetting •No lysing •Reagent: Suitable to store at room temperature (upto 30º C) The Power of HbA1c in your Hand esting Principle: Boronate Affinity Chromatography Testing Parameter: Glycohemoglobin (HbA1c) Measuring Range: 4.0% – 14.0% Precision: CV <3% (HbA1c: 4.0% – 6.5%) Blood Sample: Finger Prick or Venous Blood ( EDTA Anticoagulant) Blood Volume: About 3ul Testing Time: About 5 minutes Data Unit: Set in Advance the Data Unit • NGSP%; IFCC mmol/mol; eAG* mmol/l Voice Prompt: Voice Prompt to Guide the user Data Storage: 1000 Testing Data Data Port: Mini USB data interface can be connected with HIS/LIS; System Thermal Printer Power Required: AAA Battery x 4 Analyzer Dimension: 61.6 x 122.9 x 24.5 mm Screen Size: 47 x 32 mm” Safety Information LIMITATION AND WARNING: 1. This product is used for In Vitro Diagnostics only, not for in vivo use. 2. This product should not be used past the expiration date. 3. If there is evidence of microbial contamination or browning, discard the vial. 4. This product is not intended to be used as an HbA1c standard. 5. Preservatives contained in the control, rinse with water if splash into the mouth or eyes, and seek medical help as soon as possible. 6. Potential biological risk. Direction for Use This product should be run in accordance with instructions accompanying BioHermes Glycohemoglobin Test Kit and Glycohemoglobin Analyzer. (1) Dissolution: Open the cap of the vial, and then add 2 drops of Buffer A. Close the cap, and slightly shake the vial until the powder dissolved completely. And please shake it well before using it. (2) Testing in accordance with instructions accompanying BioHermes Glycohemoglobin Test Kit and Glycohemoglobin Analyzer. Please refer to the B Other Info Storage: 1. This product will be stable for 24 months when stored tightly capped at 2-8℃. 2. After dissolved, the product can be stable for 8 hours at 10-30℃, or 5 days at 2-8℃. Do not freeze it. COMPOSITION: This product is prepared from human blood and contains normal hemoglobin, preservatives and stabilizers. The control is provided in lyophilized powder form for increased stability. The kit contains two levels of control, level 1 is with yellow cap, and level 2 is with green cap.

Send Message

Still searching for
open vial sampling?