Jaipur
+918529833535

'one time use'

Items tagged with 'one time use'

product image
Clinical Chemistry

Product Specification Model Name/Number i15 Brand Edan Usage/Application Laboratory Use Throughput Results In 1 Minute After Sample Aspiration Weight 3.65 Kg Battery 5000 mAh Rechargeable Lithium-Ion Battery Dimensions 238*153*310 mm (W x H x D) Display Type 7 Inch LCD Display Frequency 50 Hz Interface 4 USB 2.0 Host,1 RS232,WLAN Voltage 110- 240 V Input Device Touch Screen And Barcode Scanner Operating Temperature 10-30 Degree C Product Description Portable, lightweight Capable to run 50 samples with fully-charged battery Diagnose at the point of care, patient side, out in the Field or exam room Easy, Quick and Convenient Zero maintenance Minimize hands on time and training requirement Auto-sampling Report is ready within one minute after sample aspiration Accurate and Reliable Innovative microchip liquid control technology and micro-sensor multifunction membrane technology High sensitivity and accuracy Calibrator, Control and Electronic simulator to TRIPLE guarantee the RESULTS! Flexible Data Management Acquire patients' information via barcode/QR code Up to 10,000 patient data storage 4 USB ports and LAN/WiFi for data management Optional data management software Multi-parameter cartridge Multi popular time-sensitive parameters come in one cartridge, including ABG, electrolytes and metabolites Single-use cartridge avoids contamination Room temperature storage with long shelf-life

Send Message
product image
Hemostasis Analyzer

Product Description: It’s a modern and advanced analyzer in Hemostasis. This single channel coagulation analyzer redefines the benefits in its class Erba. ECL 105 can perform PT, APTT, Fibrinogen, Thrombin Time, All Factiors, Lupus and DDimer. Product Features: Clotting Tests such as PT, aPTT, Fibrinogen, Thrombin time, Factors, Lupus anticoagulant performed using Light scatter principle Tests like D Dimer performed using Immuno-turbidimetry principle Interactive touch screen interface Clotting Graph provides details of the clotting testCuvette and reagent management software Twelve levels of QC with Levy-Jennings Plot- Identifies random and systematic errors Temperature stability at 37 degree C to perform the tests. Low Reagent Consumption USB Connectivity CE mark Product Applications: ECL 105 has uses in various routine IVD labs for doing routine PT and aPTT It has application in Blood Banks for Quality Control of Fibrinogen and Factor VIII It is used as Standby to bigger systems, in accredited centres It is used in Research Facilities to perform PT and aPTT on animal samples such as rat, mouse, rabbit, hamsters etc Key Specifications: Single channel semi-automated hemostasis system It can analyze 1 test at a time Sample id can be 14 digits alphanumeric, with progressive id or custom id options It is also possible to have a second position of assay preparation/incubation during the analysis of the current one, using preparation line option Optically detects and automatically moves to the next assay steps and auto starts the measurements Tests principles: Clotting (scattered light at 640nm) Immuno-turbidimetric (turbidimetry at 800nm) Dimensions / Weight: Dimension : 216 x 205 x 75 mm Weight : ~1 kg Environmental requirements: Operating Temperature : 17-32°C Humidity: Max. 80% Relative Humidity, non-condensing Power: Power Supply : 100-240 VAC and 50/60 Hz Power Consumption : 45 Watts In-Rush Power : 150 VA or less Calibrations: Up to 6 calibration levels per assay Storage of the active calibration curve Quality Controls: Up to 12 different control total can be assigned to any given assay Automatic Levey-Jennings plotting Automatic statistics calculation Storage of Quality Control results Stored Results: Independent storage allocation in the instrument memory for Quality Control (QC) and patient determinations Up to 1000 results for QC determinations Up to 1000 results for patients New results automatically replace the oldest results of the appropriate category past the maximum storage allowance Reaction curves are exclusively stored on the external USB pen drive. Regular backup and file purging is recommended from the USB pen drive to insure rapid operations. USB pen drive, FAT32 formatted

Send Message
product image
Critical Care

Product Description: Medica Corporation’s EasyLyte® analyzer is a completely automated, microprocessor-controlled electrolyte system that uses ISE (Ion Selective Electrode) technology to make electrolyte measurements. The EasyLyte measures combinations of Na+, K+, in whole blood, serum, plasma, or urine. EasyLyte incorporates state-of-the-art electronics and an innovative ergonomic design that differentiates it significantly from competitors. The analyzer also stores quality-control data that is easily accessible. Patient histories are immediately retrievable for evaluation. EasyLyte analyzers combine simple yes/no prompted operation, low maintenance, and high reliability into one economical design. Product Features: EasyLyte is Easy to Use, Easy to Operate, Easy to Maintain The entire menu is driven by 2 simple buttons Results are displayed on LCD screen as well as printouts EasyLyte does 2 point as well as 1 point calibration Facility to analyze different type of samples: whole blood, serum, plasma ,urine samples EasyLyte has capillary and syringe sampling facility EasyLyte has auto probe wiping facility Analysis of electrolytes is done using 100ul of blood and 400ul of diluted urine Rate of analysis 55 secs per sample Analyzer is capable of storing 128 patients data with trilevel QC results Analyzer has modular plug in reagent pack system EasyLyte has facility for auto calibrations with a programmed interval of 4 hrs and also calibration on demand Analyzer has facility to upgrade to a walk away Electrolyte station by use of Auto Sampler It has a built in thermal printer and a RS 232 port for interfacing Product Applications: Sodium - Na, Potassium - K CLIA Classification: Moderate Complexity Sample Type: Whole Blood, Serum, Plasma or Urine Sample Size: 100 µL Whole Blood, Serum, Plasma, 60 µL capillary or 400 µL diluted (1:10) Urine Method: Direct measurement by Ion Selective Electrode (ISE) Measurement Range: Blood Urine Na+: 20 – 200 mmol/L Na+: 25 – 1000 mmol/L K+: 0.2 – 40 mmol/L K+: 1.0 – 500 mmol/L Cl-: 25 – 200 mmol/L Cl-: 25 – 500 mmol/L Li+: 0.2 – 5.0 mmol/L Ca++: 0.1 – 6.0 mmol/L pH: 6.0 - 8.0 Units Display Resolution: Na+: 0.1 mmol/L K+: 0.01 mmol/L Cl- : 0.1 mmol/L Li+: 0.01 mmol/L Ca++: 0.01 mmol/L pH: 0.005 units Test Time: Na/K Na/K/Cl Na/K/Li Na/K/Cl/Ca Analysis time (blood) 55 sec 55 sec 55 sec 60 sec Urine mode Yes Yes Yes No Analysis time (urine) 90 sec 90 sec 90 sec N/A EasySampler Yes Yes Yes No Capillary Samples Yes Yes Yes No Data Storage: Patient Results: up to 128 samples QC Results: up to 20 each Normal, Low, and High Calibration: Automatic or On-Demand Output: 128 x 64 pixel graphic display 24 column thermal printer Serial port (RS-232), EasySampler port Ambient Conditions: 15–32oC (60–90oF), <85% humidity Power: 100-240 VAC 50/60 Hz, 0.8A Size & Weight: 9.5”W x 16.5”H x 8.0”D (24 cm W x 42 cm H x 20 cm D) 13 lbs. (5.8 kg) Reagents used with this 'EasyLyte' CLIA Classification: Moderate Complexity Sample Type: Whole Blood, Serum, Plasma or Urine Sample Size: 100 µL Whole Blood, Serum, Plasma, 60 µL capillary or 400 µL diluted (1:10) Urine Method: Direct measurement by Ion Selective Electrode (ISE) Measurement Range: Blood Urine Na+: 20 – 200 mmol/L Na+: 25 – 1000 mmol/L K+: 0.2 – 40 mmol/L K+: 1.0 – 500 mmol/L Cl-: 25 – 200 mmol/L Cl-: 25 – 500 mmol/L Li+: 0.2 – 5.0 mmol/L Ca++: 0.1 – 6.0 mmol/L pH: 6.0 - 8.0 Units Display Resolution: Na+: 0.1 mmol/L K+: 0.01 mmol/L Cl- : 0.1 mmol/L Li+: 0.01 mmol/L Ca++: 0.01 mmol/L pH: 0.005 units Test Time: Na/K Na/K/Cl Na/K/Li Na/K/Cl/Ca Analysis time (blood) 55 sec 55 sec 55 sec 60 sec Urine mode Yes Yes Yes No Analysis time (urine) 90 sec 90 sec 90 sec N/A EasySampler Yes Yes Yes No Capillary Samples Yes Yes Yes No Data Storage: Patient Results: up to 128 samples QC Results: up to 20 each Normal, Low, and High Calibration: Automatic or On-Demand Output: 128 x 64 pixel graphic display 24 column thermal printer Serial port (RS-232), EasySampler port Ambient Conditions: 15–32oC (60–90oF), <85% humidity Power: 100-240 VAC 50/60 Hz, 0.8A Size & Weight: 9.5”W x 16.5”H x 8.0”D (24 cm W x 42 cm H x 20 cm D) 13 lbs. (5.8 kg)

Send Message
product image
HEMOGLOBIN METER

Mispa HbX Portable Haemoglobin Analyzer Overview Mispa HbX , Smart Haemoglobin analyzer is a symbol of advanced point of care equipment with modern technology and convenience, designed to deliver high accuracy, quality results with least turnaround time and low maintenance. Best in Class Hemoglobin Meter Mispa HbX, the Smart Haemoglobin Analyzer, is the best example of an advanced point-of-care hemoglobin reader with modern technology. It is easy to use and designed to deliver accurate, high-quality results with the shortest turnaround time and minimal maintenance. This digital Hb meter is one of the best hemoglobin meters available. Working of A Hemoglobin Meter or a hemoglobin reader A hemoglobin meter or a hemoglobin reader measures the amounts of hemoglobin and hematocrit in whole blood. Hemoglobin tests are typically performed to determine the RBC count, the severity of anemia, hematocrit, and other haematological factors. It is widely utilized during blood donations and key decisions such as blood transfusions. HbX works with Spectrophotometry Scattered compensation Technology for accurate and quick results Results will be retrieved with in less than 3 seconds after sample reading starts Sample Required: 7ul Capillary or Venous blood Three Step procedure makes HbX more convenient to use CV value will be less than 1.5 % 6 Hours Battery Backup makes it a hand equipment 2000 Data storage capacity Micro Fluidic cuvettes with 2 year Shelf life

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ TSH Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA System for quantitative determination of thyroid stimulating hormone (TSH) in human whole blood, serum or plasma. This test is used as an aid to assist in the assessment of pituitary gland and thyroid function. STORAGE AND STABILITY 1. Store the test kit at 4℃~30℃ up to the expiration date printed on package. 2. If removed from refrigerator, allow the test kit for 30 minutes to return to room temperature before testing. 3. Do not remove the Test Cartridge from the pouch until use. The Test Cartridge should be used within 1 hour once opened.

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ Progesterone Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA System for quantitative determination of progesterone in human serum, plasma or whole blood. The test is used as an aid to the track ovulation. STORAGE AND STABILITY 1. Store the test kit at 4℃~30℃ up to the expiration date printed on package. 2. If removed from refrigerator, allow the test kit for 30 minutes to return to room temperature before testing. 3. Do not remove the Test Cartridge from the pouch until use. The Test Cartridge should be used within 1 hour once opened.

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ Testosterone Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA Meters for quantitative measurement of Testosterone in human whole blood, serum or plasma. The test is to be used as an aid in the diagnosis of diseases related to abnormal testosterone levels. STORAGE AND STABILITY 1. Store the test kit at 4~30ºC up to the expiration date printed on the package. 2. If removed from refrigerator, allow the test to return to room temperature for 30 minutes before testing. 3. Do not remove the cassette from the pouch until ready to use. The test cassette should be used within 1 hour once opened.

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ One Step cTnT Rapid Quantitative Test along with Finecare™ FIA Meters is a fluorescence immunoassay for quantitative determination of cTnT concentration in human venous whole blood, serum or plasma specimen. It is mainly used as an aid to the diagnosis of myocardial infarction. STORAGE AND STABILITY 1.Store at 4~30 °C up to the expiration date printed on the package. 2. Do not remove the Test Cartridges from the pouch until ready to use. The Test Cartridges should be used within 1 hour once opened.

Send Message

Still searching for
one time use?