Jaipur
+918529833535

'minimum reaction volume'

Items tagged with 'minimum reaction volume'

product image
Urinalysis Analyzer

High Performance "Full Automated System" Color Touch Panel for good usability 7 inch WVGA color touchscreen with high operability displays measurement results, instrument conditions and operating instructions. "Sample delivery system" enables micro volume samples to be measured As the sample is drawn through the nozzle and delivered correctly and quantitatively to each pad of the strip, the micro volume samples (minimum 1mL) can be measured easily. No cross contaminations are found on the reagent portions despite high sample volume. Sample Urine Test items Glu, Pro, Bil, Uro, Ket, pH, Nit, Bld, Leu, S.G., Alb, Cre(Alb/Cre ratio, Pro/Cre ratio can be calculated), turbidity and color tone Wavelength 5 LED wavelengths (430, 500, 565, 635, 760nm) Measurement principle Test strip :Dual-wavelength reflectance method (One-wavelength for Bld) Specific gravity :Reflection refractometryColor hue :Light-transmission measurementTurbidity :Light-scattering measurement method Test strip AUTION Sticks (10EA & 10PA) , Uriflet S 11UA Reaction time Approximately 60 seconds Throughput 225 samples per hour Strip storage Maximum 400 strips (200 strips x 2 feeder boxes) Required sample volume Normal, STAT measurement: Minimum 2 mL Small volume measurement: Minimum 1 mL Sample consumption Normal, STAT measurement: Maximum 0.90 mL Small volume measurement: Maximum 0.45 mL Sample container Sample tubes (length: 95 - 110 mm, diameter: ø14.0 - 15.8 mm) Maximum sample load 100 samples (Circulation) Data memory Normal, STAT, small volume measurement: 2500 tests Control measurement: 200 tests Check measurement: 50 tests Trouble list: 100 tests Display Large color liquid crystal display (800 × 480 dots) Built-in printer 58-mm width printer paper (24 digits) External output 1 port (Replaceable with the optional Ethernet terminal) Communication method RS-232C compliant (Switchable between one-way and two-way) Measurement environment Temperature: 10 - 30°C; Humidity: 30 - 60% RH (No condensation) Power requirements 100 - 240 V AC (Maximum power line fluctuation of ±10%), 50/60 Hz Power consumption 150VA (Maximum) Dimensions 530 (W) × 530 (D) × 550 (H) mm (including the sampler) Weight Main body: Approximately 36 kg Sampler: Approximately 4 kg

Send Message
product image
Clinical Chemistry

Best Fully Automated Clinical Chemistry Analyzer – Sphera M from Accurex. This chemistry analyzer is made in Italy & provides Accurate, Precise and Rapid Testing Solution. Sphera M is a Compact, fully automated, open random-access analyzer. The Minimum reaction volume is 210 µl, Minimal < 1L/h water consumption, 80 reusable UV transmitting Bionex® plastic cuvettes, 8-step wash station. It has Removable refrigerated tray with 30 open reagent positions for 50 ml or 20 ml bottles. Multiple virtual reagent disks can be programmed. The Chemistry analyser also does Auto-wash of inner & exterior probe surface. QUALITY CONTROL & CALIBRATION QUALITY CONTROL: • Levey-Jennings plots and Westgard multi rules • Upto 3 QC levels per test • QC monitor and reports • Method statistics: Test counter, CV%, mean, graphical trend analysis CALIBRATION: • Method and reagent monitor (volumes, available tests, calibration, QC status) • Automatic pre-dilution for calibrators • Upto 8 calibrators per method • Auto recalculation of result using last calibration. UNIQUE SOFTWARE DESIGN AND ARCHITECTURE: • Software designed for touch screen use • Intuitive user interface • Continuous loading of samples and reagents • Random-access and STAT • Free choice of execution order • Extended walk-away capability • Results archive with cumulative charts • Programmable automatic start up routine • Multiple work lists INTERFACE: • Bi-directional LIS, ASTM, over ethernet port of the external PC • Positive identification of samples with internal barcode reader (optional) • Printing on any Windows 7®/8® compatible printer • Method defined washing programs SYSTEM PACKS FOR SPHERA™ Accurex has developed dedicated system packs for Sphera™. Our biochemistry reagents have been intensively evaluated and validated to achieve the highest performance in Sphera™. Accurex recommends the use of these system packs according to instructions and applications validated by Accurex. Safety Information 8-step wash station for thorough cleaning of each cuvette (Needles: 6 dispensing, 6 aspiration, 1 cleaning) • Two types of systemic and special washing solutions for removing obstinate probe residues Direction for Use QUALITY CONTROL • Levey-Jennings plots and Westgard multi rules • Upto 3 QC levels per test • QC monitor and reports • Method statistics: Test counter, CV%, mean, graphical trend analysis CALIBRATION • Method and reagent monitor (volumes, available tests, calibration, QC status) • Automatic pre-dilution for calibrators • Upto 8 calibrators per method • Auto recalculation of result using last calibration Other Info Accurex has developed dedicated system packs for Sphera™. Our biochemistry reagents have been intensively evaluated and validated to achieve the highest performance in Sphera™. Accurex recommends the use of these system packs according to instructions and applications validated by Accurex.

Send Message
product image
Clinical Chemistry

Product Specification Model Name/Number HumaStar 200 Brand Human Automation Fully Automatic Display Digital Dimensions 69 x 76 x 52 cm (WxDxH) Frequency 50/60 Hz Voltage 220-240 or 110-120 Vac Temperature 16-30 Degree C Throughput Up to 200 t/h throughput Weight 51 kg Reaction volume 210-350 il Wash station 6 dispensing needles Water consumption < 2 l/h (8 ml/test) Languages English, French, Spanish Software (other languages can be added) Humidity < 80 % non-condensing Data External computer required (Pentium IV, 2 GHz Mode Open, random-access, STAT Product Description Product Detail : Unique Random-Access Analyzers for Small to Medium Size Laboratories Unique design Unique software architecture Unique features Analysis Endpoint (bichromatic), Differential endpoint (with sample blank), Fixed time, Kinetic (bichromatic) Multi-standard (up to 8), factor, linear, non linear (cubic-spline, poly-linear and logit-log four parameters) Samples Removable sample tray 60 positions: primary tubes 12–12.5x100 mm and 10 mm cups Optional: sample tray for 20 primary tubes 12–16x100 mm and 20 cups 3.5 ml Sample volume: 2–300 µl Internal barcode reader Automatic pre- and post-dilution Test profiles and replicates Reagents Removable reagent tray 30 reagent / diluent positions 50 and 20 ml bottles, adapter for tubes and cups Reagent volumes: 5–350 µl Refrigeration to ~9 Degree C below ambient (at bottom of bottle) Substrates, Enzymatic, Turbidimetric Reaction Reaction volume: 210–350 µl 80 reusable Bionex® cuvettes 6 mm optical path Heat transfer by air Pipetting Needle shock detector Capacitive liquid level detector Wash station 8-step cuvette wash station Systemic and special washing solution HumaStar 200: 6 dispensing needles Water consumption < 2 l/h (8 ml/test) Optical system 9 discrete wavelengths (340, 405, 505, 546, 578, 600, 650, 700 nm, one free position) Band pass: +/– 5 nm Photometric linearity: 0–2.5 Abs Stability: <1 % drift per day Management 20 GB HDD, 512 MB RAM, CD/R, USB) Windows 7® with .NET framework 4.0 English, French, Spanish OS recommended Core i3TM or dedicated graphic card recommended Minimum 900 dots resolution Designed for touch screen (1280x1024 pixel) LIS: Bi-directional, polling mode, ASTM, ethernet Printouts By patient, single test, complete sample, work sheet, method and QCs, calibration curves, kinetics, continuous printing

Send Message
product image
Clinical Chemistry

Product Specification Automation Fully Automatic Brand Erba Model Name/Number EM200 Throughput 200 Photometric Tests/Hour & 400 Tests/Hour With ISE (Optional) Number Of Reagent Positions 50 Cooled Reagent Positions Weight Approx 120 Kg Dimension 810 x 800 x 600 mm (W x D x H) Sample Type Whole Blood, Serum, Plasma, Urin And, CSF Reading Volume 180 Micloliter Power Consumption 600 VA Reaction Tray 45 Hard Glass Cuvettes Minimum Order Quantity 1 Product Description Accurate Result Environment Friendly Cost Saving Consistent performance Quality & Service

Send Message
product image
Clinical Chemistry

EM 360 is a Fully Automated Clinical Chemistry Analyser which is time tested and proven technology. It is designed to provide the most demanding productivity, speed and operational ease. EM 360 with a throughput of 360 tests/hour offers flexibility in operation and rugged performance to win against high workload, tight deadlines, multiple tasks and complexity of testing. It yields high quality results for virtually any biochemistry test to deliver quick, efficient and consistent performance. Product Features: Automated, Discrete, Patient prioritized, Floor model Based on proven technology, Diffraction Grating Separate probes for Reagent R1 & R2 and dedicated probe for sample Low reading volume of 200 µl only Onboard cooling for reagents to enhance the reagent stability Barcode for reagents & samples (Optional) Wide test menu Product Applications: End Point Reactions: Glucose, Cholesterol, Triglycerides, Albumin, Total Protein, Uric Acid, Calcium, Magnesium, Bilirubin Total, Bilirubin Direct Kinetic Reactions: SGOT, SGPT, GGT, LDH, CK, CK MB, ALP, ACP, Amylase, Lipase Two Point Rate Reactions: Urea, Creatinine Immunoturbidimetric Chemistries: RA, CRP, ASO, Direct HDL, Direct LDL, Apo A, ApoB, Lp (a) Special Chemistries: HbA1c, Iron, Ferritin, Phosphorus, Microprotein, Ammonia, Bicarbonates System Type: Discrete, automated, random access, patient prioritized clinical chemistry analyzer Throughput: 360 tests / hour photometric and 600 tests / hour with ISE* (*optional ISE with Na+, K+, Cl-, Li+) Analytical Methods: 1-Point, 2-Point, Rate-A, Rate-B, Direct Potentiometry (optional) Barcode Reader: For reagents and samples (optional) Reaction Tray: 60 hard glass cuvettes Reaction Mixing: Stirrer with variable speed Minimum reaction Volume: 150 μl with maximum 200 μl reading volume On-board Laundry: 5 stage cleaning, 2 stage drying Photometer: Multi-wavelength diffraction grating with 12 wavelengths (340, 376, 415, 450, 480, 505, 546, 570, 600, 660, 700, 750 nm) OD Range: 0.0 - 3.0 Light Source: Halogen lamp Detector: Silicon photo-diode Water Consumption: < 10 litres Programmable Parameters: Default system pack parameters + upto 99 user defined parameters, Unlimited profile and unlimited calculation items Quality Control: QC plot data with QC rules. Provision for lab mean. Twin plot Calibration: K-Factor, Linear (1, 2 point & multipoint), 4P and 5P Logit-log, cubic spline, exponential, polynomial, On-board serial dilution for calibrator Power Requirement: AC 220 V ± 10 %, 50 Hz or AC 110 V ± 10 %, 60 Hz Power Consumption: 800 VA Dimension (mm): Approx. 675 (W) x 840 (D) x 1120 (H) Weight: Approx. 150 kgs. SAMPLE HANDLING Sample: Serum, Plasma, Urine, CSF, Whole blood, other Sample Unit: 82 positions for samples, blank , controls, calibrators, STAT sample Sample Pipetting: 2 - 70 µl (adjustable in 0.1 µl step) for Biochemistry, 70 µl fixed for ISE Capacitance probe with liquid level sensing & vertical obstruction detection, serum indices Auto Rerun: Repeat with same, increased or decreased volume ( upto 1:150) Sample Tubes /Cups: Primary tubes of 5 ml, 7 ml, 10 ml and sample cups REAGENT HANDLING Reagent Tray: 50 positions for reagents with onboard cooling Reagent Pipetting: R1: 50 - 300 µl (adjustable in 1 µl step) R2: 10 - 200 µl (adjustable in 1 µl step) Capacitance probe with level sensing & vertical obstruction detection SYSTEM INTERFACE: Analyzer-PC: USB PC - Host Computer: Bidirectional TCP / IP & RS - 232 PC - Printer: USB Operating System: Windows Based Database: Unlimited Results

Send Message
product image
Clinical Chemistry

Product Description: An advanced & versatile semi automated analyzer for all Clinical chemistry, Electrolytes, Immunoturbidimetric assays and Coagulation test Product Features: Semi automated analyzer 56 direct access keys Temperature selection for 20oC - 40oC in steps of 1oC 5 reporting formats Online display of reaction curve Result recalculation Three levels of quality control with Levy Jennings plot 5 reporting formats USB port interface for PC & printer Product Applications: Entire range of Clinical chemistry, Electrolytes, Immunoturbidimetric assays and Coagulation Optical Module: Static photometer with photometric range (340-670) 8 Interference filters 340, 405, 450, 505, 546, 578, 600 and 670 n.m. Silicon photodiode detectors Photometric range from 0 to 3.0 OD Quartz Halogen lamp of 12V, 20W Measuring Module: Unique Triple cuvette system 18 µl Flow cell 10 mm Square cuvette 6 mm Round glass tube with adaptor Peltier temperature control: 20°C-40°C in steps of 1°C Peristaltic Pump Minimum aspiration volume 200 µl Analysis Modes 1-point linear Rate A non-linear 2-point linear 1-point sample blank linear 1-point non-linear 1-point sample blank non-linear 2-point non-linear Absorbance Rate A linear Coagulation Memory: 200 User defined test programs 1000 test result Reagent Blank 3 Levels of QC Result Recall: Collated Reports by Date, ID, Date & ID Test & Date wise Patient Demographics Built-in QC: Daily and monthly monitoring for 3 Levels Levy-Jenning QC graphs Display: High resolution graphics LCD with backlight. View Area: 120 x 92 mm Keyboard: 41 Multifunction Keys and 6 dynamic keys Printer: In built high resolution graphic thermal printer Interface: USB connectivity to PC Direct printer connectivity through USB port Port for External keyboard Power: External Universal SMPS adapter 18V DC, 70W, 115/230V AC (± 10%), 50/60 Hz Size: (mm): 205 (H) x 450 (W) x 300(D) Weight: Approx. 7 Kgs. Optional Accessories: External 16 Position Dry Block Incubator

Send Message
product image
Clinical Chemistry

XL 1000 with the throughput of upto 1040 tests per hour is the ideal instrument for centralizing the complete biochemistry testing load on a single fully automated platform. Increased walk away productivity and less human intervention make it an ideal analyzer for large laboratories. Equipped with all necessary advanced features that one expects from a high end fully automated chemistry analyzer; sample loading through rack system, cooled calibrator and control carousel, low reading volume of 150 µL, diffraction grating with 15 wavelengths from 340 nm to 800 nm and user-friendly software, to optimize and reliably run the daily lab workload. XL 1000 is a "dream come true" workhorse for laboratories with increased workload and the perfect solution. Fully Automatic, Discrete, Patient prioritized, Random Access Clinical Chemistry Analyzer with throughput of 1040 tests/hour 3 Reagent capabilities 147 long life Hard Glass cuvettes Separate Carousel for STAT samples Onboard refrigeration for reagents Extensive database for storing patient data and Q.C. results Primary tube sampling with bar code identification 9 stage laundry for cuvettes wash 150 samples can be loaded at a time through rack system System Discrete, open, automated, random access, patient prioritized, 1/2/3 reagent system DISPENSING OF SAMPLES AND REAGENTS Sample volume: 2-60 µl (0.1 µl step), 70 µl with ISE Reagent volume: 120 µl – 550 µl 3 dispensing probes ( R1, R2/R3) equipped with liquid -level sensor and crash detector Auto-dilution of samples and calibrators Clot detection Samples Serum, urine, plasma, CSF and other Economy Minimum reaction volume: 180 µl Reusable reaction cuvettes Mixing System 2 independent stirrers 3 user selectable mixing speeds Quality Control 4 levels of control material can be used Levey-Jennigs graphs Twin Plot diagrams for monitoring of systematic and random error Reaction unit with wash station 147 reusable hard glass cuvettes Possibility of replacement of individual cuvette Wash station – cuvette rinsing and drying in nine-step procedure Automatic cuvette blank measurement before analysis Sample Autoloader 23 racks 115 sample positions on automatic autoloader Primary tubes 5, 7 and 10 ml, vacuum system tubes Barcode reader for sample identification 2 Reagent trays With 43 cooled position each Barcode reader for reagent identification 20 ml, 50 ml reagent containers, 5 ml tube with adaptor Option to use one reagent for several test simultaneously Stat Tray 45 positions Can be used for blank, controls, STAT samples Software Convenient user interface Connection to LIS Programmable auto-start from sleep mode including automatic daily maintenance Statistical methods of processing results Data export in selected format Measurement Monitoring Colour indication of sample analysis Possibility of monitoring the reaction in real time Reagent volume monitoring Informative reports on ongoing analyzer status

Send Message
product image
Biochemistry Analyzer

Overview A fully automated POC Auto Dry Biochemistry Analyzer called Mispa Chem Dx, With Just 3 to 4 drops (100ul) of whole blood to test up to 19 General and Special chemistry tests in less than 12 minutes. Mispa Chem Dx works on absorption spectroscopy where a change in absorbance is detected by an absorption spectrum and an algorithm is used to calculate the end concentration of the sample in the reagent dry disc. The reagent disc consists of lyophilized reagent beads, diluent, and calibration details in the QR code. The reagent disc contains an intelligent internal quality control system IQC which continuously monitors the disc function to ensure reaction stability and optimal disc performance, IQC is the engine that drives the Mispa Chem Dx accurately and precisely Low Sample Consumption Easy to Use Maintenance Free Accurate Result Disposable reagent disc Sample volume: 100µl Testing time: 12 minutes / sample Temperature: 37°C ± 0.3°C Resolution: 0.001Abs Absorbance: 0-3.0Abs Sample type: Heparinized whole blood, serum, plasma (heparin) QC&Calibration: IQC (Intelligent Quality Control/Calibration) Work condition: Temperature:10-30°C Humidity: 30%-70% Testing method: End point, kinetic, fixed time, turbidmetry etc Light source: 12V/20W, Halogen tungsten lamp with life span over 2500 hours Power supply: AC 100V-240V, 50-60Hz Display: Android 7.0 inch 800*480, multi-point capacitive touch screen Storage: 500,000 results Printer: Built-in thermal printer Interface: 4 USB ports, 1 LAN port Dimension: 315*375*475mm. 4.2kg(N.W.), 7kg(G.W.)

Send Message
product image
Hematology

The BC-3600 Hematology analyzer features closed tube sampling via a single push button. A built-in large 10.4 inch color touchscreen allows maximum visibility. Hemoglobin analysis is performed using cyanide-free reagent. The analyzer processes up to 60 samples per hour and stores up to 40,000 results with histograms. The barcode reader and optional LIS connectivity enable seamless sample data transmission. Nearly all scheduled maintenance procedures are automated by touch buttons. The intuitive software enhances workflow efficiency and provides operators with a pleasant user experience. Key Features CBC plus 3-part differential, 16 parameters + 3 histograms 60 samples per hour, 1 min per CBC Closed tube sampling, minimize operational biohazard Built In diluent dispenser for predilution mode All-in-one CBC result screen display; results at a glance Touch button maintenance procedures One maintenance reagent only – probe cleaner Storage capacity of 40,000 results with histograms Uploadable QC files; ensure accuracy and time efficiency Parameters WBC, Lymph#, Mid#, Gran#, Lymph%, Mid%, Gran%, RBC, HGB, HCT,MCV, MCH, MCHC, RDW,PLT, MPV and histograms for WBC, RBC, PLT Principles Electrical impedance method for cell counting and Cyanide - free for hemoglobin Sample Volume Prediluted 20µL Whole Blood 21µL Carryover WBC/RBC/HGB≤0.5% PLT≤1.0% Connectivity 4 USB ports (for external printer, software upgrade, barcode reader,keyboard and mouse), LAN port (1), RS232 (1) Printout Thermal recorder, 50mm width paper, various printout formats, external printer (optional) Product Specification Brand Mindray Differential Type 3-Part Model Name/Number BC 3600 Display Type Large color touch screen Resolution 800x600 Usage/Application Hospital Throughput 60 samples per hour Power Supply AC 100-240V,50/60 +-1Hz Weight 62 lbs Dimension 16 in(W) x 18 in(H) x 18 in(D) Humidity 30%-85% Temperature 15 ~30 Deg C Minimum Order Quantity 1

Send Message

Still searching for
minimum reaction volume?