product image
Urinalysis

Product Description: It is a hybrid & walkaway system for automated chemistry & sedimentation/ microscopic analysis of Urine sample Product Features: Fast and accurate classification and quantitative determination of the urine sediment Clear and sharp images of the actual appearance of elements simulating visual microscopy Automatic recognition of elements in sediment based on sophisticated artificial intelligence Accurate evaluation of test strips by color matrix definition technology Product Application: This system is truly walk away analyzer aiding rapid and reliable urine analysis for labs and hospitals with high workload. Strip Analysis: Method - Reflective Photometry , Input Tray Capacity- 200 strips, Parameters- 10 Sediment Analysis: Method- Automated Brightfield Microscopy with Advanced Element recognition, Number of Images- 15 images/sample, Parameters- 16 categories System throughput: Hybrid Mode (Chemistry & Sediment) - 100 samples/h, Sediment Only- 180 samples/h Sample handling: Memory capacity- 500,000 results, Rack Size- 10 tubes, Sample load capacity - 120 samples, Sample Volume- Min 2ml Control System: Display- 23'' Multi-touch screen, OS- Windows 8.1, Printer interface-USB, LIS Interface-Bi-directional Certification: CE certified

Send Message
product image
Urinalysis Analyzer

High Performance "Full Automated System" Color Touch Panel for good usability 7 inch WVGA color touchscreen with high operability displays measurement results, instrument conditions and operating instructions. "Sample delivery system" enables micro volume samples to be measured As the sample is drawn through the nozzle and delivered correctly and quantitatively to each pad of the strip, the micro volume samples (minimum 1mL) can be measured easily. No cross contaminations are found on the reagent portions despite high sample volume. Sample Urine Test items Glu, Pro, Bil, Uro, Ket, pH, Nit, Bld, Leu, S.G., Alb, Cre(Alb/Cre ratio, Pro/Cre ratio can be calculated), turbidity and color tone Wavelength 5 LED wavelengths (430, 500, 565, 635, 760nm) Measurement principle Test strip :Dual-wavelength reflectance method (One-wavelength for Bld) Specific gravity :Reflection refractometryColor hue :Light-transmission measurementTurbidity :Light-scattering measurement method Test strip AUTION Sticks (10EA & 10PA) , Uriflet S 11UA Reaction time Approximately 60 seconds Throughput 225 samples per hour Strip storage Maximum 400 strips (200 strips x 2 feeder boxes) Required sample volume Normal, STAT measurement: Minimum 2 mL Small volume measurement: Minimum 1 mL Sample consumption Normal, STAT measurement: Maximum 0.90 mL Small volume measurement: Maximum 0.45 mL Sample container Sample tubes (length: 95 - 110 mm, diameter: ø14.0 - 15.8 mm) Maximum sample load 100 samples (Circulation) Data memory Normal, STAT, small volume measurement: 2500 tests Control measurement: 200 tests Check measurement: 50 tests Trouble list: 100 tests Display Large color liquid crystal display (800 × 480 dots) Built-in printer 58-mm width printer paper (24 digits) External output 1 port (Replaceable with the optional Ethernet terminal) Communication method RS-232C compliant (Switchable between one-way and two-way) Measurement environment Temperature: 10 - 30°C; Humidity: 30 - 60% RH (No condensation) Power requirements 100 - 240 V AC (Maximum power line fluctuation of ±10%), 50/60 Hz Power consumption 150VA (Maximum) Dimensions 530 (W) × 530 (D) × 550 (H) mm (including the sampler) Weight Main body: Approximately 36 kg Sampler: Approximately 4 kg

Send Message
product image
Urinalysis Analyzer

COBIO S50 is Fully Automated Urine Sediment Analyser. COBIO S50 is Automation of the "Gold Standard" manual microscopy! • Throughput - 50 sample/hours • Large (13.3') high-resolution touch-screen for viewing actual images • Each test is processed in 1 cuvette - no carry-over between samples • Just 1.5 mins testing time / sample • High-definition in-built cameras capture "whole view-field" images similar to HPF images of manual microscopy • Latest "deep learning AI" technology identify, classify, label and count each sediment particle - Fully automated sample preparation (sample mixing, centrifuging, preparation of homogenized layer) to minimize manual errors - Large touch-screen helps zoom-in / zoom-out to access and review images and easily access the menu. - Each test is processed in 1 cuvette – no carry-over between samples - Just 1.5 mins testing time / sample

Send Message
product image
Clinical Chemistry

TURBOSTAT PLUS – SEMI AUTOMATED CHEMISTRY ANALYZER Photometric linearity range from 0 to 4.0 Abs 8 filters standard wavelength and 2 more free position Windows-based user-friendly interface with high-speed CPU processor Analysis method: Endpoint, Kinetic, Fixed time, Turbidimetry, Multipoint, Factor etc., Real-time reaction monitoring graph for each test Interactive test programs up to 300 parameters Sample Result storage up to 2,00,000 Built-in incubator to maintain the temperature for sample testing 7” touch screen TFT LCD display 4 USB Host, 1 USB slave and 1 Ethernet port for efficient support Built-in thermal printer Technical Specs Linear Measuring Range 0 to 4.0Abs Light Source Tungsten Lamp with lamp saver feature Standard Wavelength 340,405,450,505,546,578, 630 nm. 2 more for optional Modes End-point, Two-point, Kinetic, Multi-point, Factor Test Menu 300 open programmable test option Illuminated volume of Flow Cell 32 μL Printer Thermal Printer Display 7 inches LCD touch screen Storage 2,00,000 Result Interface 4 USB Hosts, 1USB Slave, 1 Ethernet port. Power Requirement 100~240VAC, 50/60Hz Dimensions 400mm (L) x 300mm (W) x 160mm (H)

Send Message
product image
Clinical Chemistry

Best Fully Automated Clinical Chemistry Analyzer – Sphera M from Accurex. This chemistry analyzer is made in Italy & provides Accurate, Precise and Rapid Testing Solution. Sphera M is a Compact, fully automated, open random-access analyzer. The Minimum reaction volume is 210 µl, Minimal < 1L/h water consumption, 80 reusable UV transmitting Bionex® plastic cuvettes, 8-step wash station. It has Removable refrigerated tray with 30 open reagent positions for 50 ml or 20 ml bottles. Multiple virtual reagent disks can be programmed. The Chemistry analyser also does Auto-wash of inner & exterior probe surface. QUALITY CONTROL & CALIBRATION QUALITY CONTROL: • Levey-Jennings plots and Westgard multi rules • Upto 3 QC levels per test • QC monitor and reports • Method statistics: Test counter, CV%, mean, graphical trend analysis CALIBRATION: • Method and reagent monitor (volumes, available tests, calibration, QC status) • Automatic pre-dilution for calibrators • Upto 8 calibrators per method • Auto recalculation of result using last calibration. UNIQUE SOFTWARE DESIGN AND ARCHITECTURE: • Software designed for touch screen use • Intuitive user interface • Continuous loading of samples and reagents • Random-access and STAT • Free choice of execution order • Extended walk-away capability • Results archive with cumulative charts • Programmable automatic start up routine • Multiple work lists INTERFACE: • Bi-directional LIS, ASTM, over ethernet port of the external PC • Positive identification of samples with internal barcode reader (optional) • Printing on any Windows 7®/8® compatible printer • Method defined washing programs SYSTEM PACKS FOR SPHERA™ Accurex has developed dedicated system packs for Sphera™. Our biochemistry reagents have been intensively evaluated and validated to achieve the highest performance in Sphera™. Accurex recommends the use of these system packs according to instructions and applications validated by Accurex. Safety Information 8-step wash station for thorough cleaning of each cuvette (Needles: 6 dispensing, 6 aspiration, 1 cleaning) • Two types of systemic and special washing solutions for removing obstinate probe residues Direction for Use QUALITY CONTROL • Levey-Jennings plots and Westgard multi rules • Upto 3 QC levels per test • QC monitor and reports • Method statistics: Test counter, CV%, mean, graphical trend analysis CALIBRATION • Method and reagent monitor (volumes, available tests, calibration, QC status) • Automatic pre-dilution for calibrators • Upto 8 calibrators per method • Auto recalculation of result using last calibration Other Info Accurex has developed dedicated system packs for Sphera™. Our biochemistry reagents have been intensively evaluated and validated to achieve the highest performance in Sphera™. Accurex recommends the use of these system packs according to instructions and applications validated by Accurex.

Send Message
product image
Hematology

Buy the Best Automated Hematology Analyzers – Acculab CBC 360 Neo. This Hematology Analyser Machine is Truly Automated for self-checking, background test, calibration, sampling, dilution, mixing, printing, dormancy, alarms, cleaning and maintenance. CBC 360 Neo is 3 part hematology analyzer from Accurex & is Automated for Walk-away Operations. Dual Chamber: Measurement of RBC / platelets & WBC / HGB in different chambers ensure accurate counting in a short time. The micro-aperture sizes of both the chambers are well designed to avoid error due to cell misclassification Automation for Walk-away Operation: Auto Self-check : Automatic aspiration of reagents & rinsing of tubings on startup Auto Blank : Background test is run automatically on startup Auto Print : Automatic printing of report with / without histogram Auto Sleep : Dormancy status is entered after a set period of non-operation Auto Alarms : Audio / visual alarms in case of system errors & abnormal results Auto Clean : Automatic rinsing options available to maintain the system Dual Chamber: Measurement of RBC / platelets & WBC / HGB in different chambers ensure accurate counting in a short time. The micro-aperture sizes of both the chambers are well designed to avoid error due to cell misclassification Specifications: Measurement principle: Electrical resistance for counting RBC, WBC & Platelets Colorimetric estimation of HGB at 540 nm Parameters: WBC, LY, MO, GR, LY%, MO%, GR%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR Throughput: 60 samples/hour Micro-aperture: WBC : 100 um RBC / PLT : 68 um Sample type: Whole blood or pre-diluted sample Sample volume: Whole blood (venous blood) : 10 ul Chamber: Pre-diluent (capillary blood) : 20 ul, Pre-diluent (capillary blood) : 20 ul Reagents: Dual chamber : RBC / Platelets & WBC / HGB Quality control: 4 QC options : L-J, X-B, X-R & X QC, Graphs plotted with 31 data points Data memory: Upto 100,000 (with histogram) Display: 10.4 inch LCD with 640 x 480 resolution Printer: Built-in thermal printer Interface: Support RS-232C, standard network port and USB; keyboard and mouse Operating environment: Temperature : 15˚C – 35˚C, Humidity : 85% RH Electrical specification: Voltage : AC 110V/230V 23V Frequency : 50/60 Hz, Power : 180W Fuse specification : 250V/3A Dimensions / Weight: 670 x 515 x 640 mm / 27.5 kgs Specification Acculab CBC 360 Neo – Fully Automated Hematology Analyzer Features: 3-part differentiation of WBC Automated for — self-checking, background test, calibration, sampling, dilution, mixing, printing, dormancy, alarms, cleaning and maintenance High processing speed : 60 samples/hour Multi-parameter estimation : 20 parameters categorized according to corpuscle type for easy reporting Direct command keys for Mode, Prime, Flush, Drain & Record / Print for faster operation Run / Standby indicator lights denote the analyzer status i.e. test is being run or analyser is ready to test Whole blood/ Pre-diluent indicator lights denote the sample type in use i.e. whole blood/ pre-diluent Dual sample mode with low sample volume: Whole blood (venous) mode : 10 ul; pre-diluent (capillary) mode : 20 ul Audio alarm indication for abnormal findings or system errors 4 QC methods : L-J, X-B, X-R & X QC Comprehensive QC graphs with 31 data points for each parameter Internal & external probe cleaning facility Dormancy mode available to reduce power consumption Memory : 100,000 (with histogram) Safety Information • Large 10.4 inch single screen color display of all 21 parameters and 3 histograms • Sequential arrangement of WBC, RBC & PLT parameters for convenient reporing •Easy to understand & icon-based arrangement of menu for fast and convenient testing Direction for Use • WBC Histogram: R1, R2, R3, R4 & RM indications on histogram show specific abnormalities in the histogram & the probable causes • Platelet Histogram: PM indication is given when the boundary between PLT & RBC is ill-defined thus avoiding misclassification Other Info High voltage cautery function is useful in disintegrating obstinate protein or serum clog in the tubing

Send Message
product image
Hemostasis Analyzer

ECL 760 ECL 760 is an advanced Fully automated coagulation analyzer with seven detection channels providing operators with a compact easy-to-use system. Dedicated for mid-volume throughput labs, the ECL 760 been designed to optimize your productivity. ECL 760 is a blend of modernity and simplicity. Erba reagents oers a wide menu of test parameters for automated coagulation analyzers. KEY FEATURES ECL 760 uses the proven system of percentage intensity of light scatter at 640 nm LED. This optical system ensures early light stability, longer duration usage time and greater lamp life. It minimizes the interference of hemolysis, ictericity and lipemia, in samples at each assay, The system monitors the entire clotting process from reagent addition to complete clot formation with the generation of Clot curve. Clotting Tests  All clotting tests, such as Prothrombin Time, Activated Partial Thromboplastin Time, Fibrinogen, Thrombin time, Factors (II / V / Vll / X / Vlll / IX\ Xl / Xll), Lupus and Protein S are performed. Chromogenic Tests  Chromogenic tests use the colorimetric principle of measuring absorbance of light (405nm LED) by the test in a cuvette. Protein C and Antithrombin Illare some of the tests done by this method. Immunological Assay  The change in light intensity caused by the antigen antibody reaction is detected at 575 nm LED, as the change in the transmitted light.  D Dimer is the most common test performed

Send Message
product image
Hematology

A Truly Automated Walkaway ESR Analyzer for Midsize labs (Meets CLSI and ICSH Guidelines) Product Features: Gold Standard Method -Measures all three phases of sedimentation as per Westergren method Dry Technology - No sample & reagent consumption, no waste generation Faster TAT - Throughput of 60 samples/hr Zero consumption cost by using EDTA tubes HCT correction feature eliminates manual correction in Anaemic samples Temperature correction at 18° ensures reliable results No additional cost of Calibration Analyzer Product Code Product Name Pack size ESL 30 122020 SMART CARD 2500 1x 2500 ESL 30 122021 SMART CARD 5000 1x 5000 ype of Sample : EDTA Sample Volume : > 1.5 ml Display : TFT high resolution 640 * 480 dots with LED Backlight Result Cycle Time : < 25 min Measuring Range : 0-140 mm/hr Touch screen : 5.7 inch resistive TFT high resolution Temperature Correction : At 18 Degree HCT Correction : HCT Correction facility available for Anaemic samples QC : Inbuilt Quality Control program with LJ Graphs Quality Control Level : 3 Level QC with LJ Graph QC Data Storage : 250 QC results Sample position : 30 sample position Throughput : 60 samples per hour Sample Consumption : No Type of Mode : Continuous mode STAT Facility : Available Calibration Requirement : No Mixer : Inbuilt Mixer Printer : Inbuilt Printer Barcode reader : Inbuilt Barcode reader Data Storage : 5000 results Operating Temperature : 20 - 30 Degree Celsius Storage Temperature : 15 - 35 Degree Celsius Relative Humidity : Max. 80% RH Power Adapter external : 240V DC , 90W Main supply : 100V-240V AC, 50/60 Hz (input for power adapter ) Dimension (mm) : 550(L) x 500 (W) x 395 (H) Weight : 20 kg (Approx )

Send Message

Still searching for