Jaipur
+918529833535

'membrane wicking'

Items tagged with 'membrane wicking'

product image
Laboratory Usage

We are the Leading Supplier of Nylon Membranes. Listed among the topmost companies, we offer Nylon Membranes to the clientele. This Nylon Membranes is developed by professional’s team using high grade material and advanced equipments in compliance with the international quality standards. In addition to this, our products are accurately designed without any flaws. This product range is offered in best specification to our clients. It is perfect in deigning and well tested on different quality parameters. Moreover, our clients can avail this product from us at industrial leading rates and customized packaging. Features: Long lasting service life Quality product Flawlessly finish

Send Message
product image
Rapid Test

Buy AccuTest Syphilis Rapid Card Test (50 Tests) Online from Accurex. This Syphilis test is a special test kit designed to detect Syphilis (Treponema Pallidum- IgA, IgM, IgG) antibodies in serum/plasma. Syphilis is caused by the bacterium Treponema pallidum. There different types of test like VDRL test, RPR test, FTA-ABS, etc. AccuTest Syphilis Test Kit is easy to use at home and gives you 99% accurate result in just 5 -20 minutes, with sensitivity & specificity of 99.67%. Recombinant syphilis antigen (17KDa, 15KDa, 47KDa) is immobilized in the lest line region of the device. AccuTest Syphilis Rapid Test is a special test kit designed to detect Syphilis (Treponema Pallidum- IgA, IgM, IgG) antibodies in serum/plasma. This kit is easy to use at home and gives you 99% accurate result in just 5 -20 minutes, with sensitivity and specificity of 99.67%. 1. AccuTest Syphilis is a chromatographic immunoassay kit for rapid qualitative detection of Treponemal antibodies (IgA, IgM, IgG) generated against Treponema pallidum Antigens (17KDa, 15KDa, 47KDa) in human serum or plasma with high sensitivity and specificity. 2. Results just in 5-20 minutes 3. Accu Test Syphilis exhibits sensitivity and specificity of 99.67%. Features: Based on Chromatographic Immunoassay assay for detection of Treponema pallidum antigens Sample: Human Serum or Plasma 2-3 drops of Serum/Plasma sample required for testing Fast: 1 step method, result in just 5 to 20 minutes Excellent sensitivity and specificity of 99.67% Store unused kit at 2-30C Pack size: 50 T Recombinant syphilis antigen (17KDa, 15KDa, 47KDa) is immobilized in the lest line region of the device. After the specimen is added to the specimen well in the device, it reacts with syphilis antigen coated particles in the test. The mixture migrates chromatographically along the length of the test strip and interacts with the immobilized syphilis antigen. The double antigen test format can detect IgA, IgG & IgM in specimens. If the specimen contains TP antibodies a coloured band will appear in the lest line region indicating a positive result. In the absence of TP antibodies a coloured band will not appear in the region indicating a negative result. To serve as a procedural control, a coloured band will always appear in the control line region indicating that proper volume of specimen has been added and membrane wicking has occurred. Based on Chromatographic Immunoassay assay for detection of Treponema pallidum antigens Sample: Human Serum or Plasma 2-3 drops of Serum/Plasma sample required for testing Fast: 1 step method, result in just 5 to 20 minutes Excellent sensitivity and specificity of 99.67% Store unused kit at 2-30C Pack size: 50 T Direction for Use Procedure: 1. Bring the pouch to room temperature before opening to avoid condensation of moisture on the membrane of the device. Also bring the specimen to R.T. prior to testing. 2. Label the device with patient’s identification. 3. Add 2-3 drops (approx. 30 pl) of sample into the sample well of the test device. Avoid overflowing. 4. Wait for 5 – 20 minutes and read the result. It is important that the background is clear beforg the result is read. Note: Do not read the result after 30 minutes since specimen back flow may cause false result. STORAGE, STABILITY & HANDLING 1. The kit should be stored at 2 – 30° C. Do not freeze. 2. Do not use the kit past the expiration date stated on label. 3. Take off the device from the sealed pouch just before use as the device is sensitive to humidity and heat.

Send Message
product image
Rapid Test

Buy AccuTest HCV Rapid Card Test (30 Tests) Online from Accurex. HCV means Hepatitis C Virus which is a is a small, enveloped, positive-sense, single-stranded RNA virus. Hepatitis C symptoms are fever, fatigue, decreased appetite, nausea, vomiting, abdominal pain, dark urine, pale feces, joint pain and jaundice. HCV test is a rapid Chromatographic Immunoassay work on principle of the double antigen sandwich technique, Qualitative detection of antibodies generated against proteins that are encoded by conserved sequence of core NS3, NS4, NS5 parts of HCV genome in human whole blood/serum or plasma. AccuTest HCV Test is a rapid Chromatographic Immunoassay for the Qualitative detection of antibodies generated against proteins that are encoded by conserved sequence of core NS3, NS4, NS5 parts of HCV genome in human whole blood/serum or plasma. Hepatitis C Virus (HCV) is a small, enveloped, positive-sense, single-stranded RNA virus. Antibody to HCV is found in over 80% of patients with well documented non-A, non-B hepatitis. Conventional methods fail to isolate the virus in cell culture or visualize it by electron microscope. Cloning the viral genome has made it possible to develop serologic assays that use recombinant antigen, multiple antigens using recombinant protein and/or synthetic peptides have been added in new serologic tests to avoid nonspecific cross-reactivity to increase the sensitivity of HCV antibody tests. Storage and Stability: AccuTest HCV should be stored at 4-30C. However, the card may be stored at room temperature not exceeding 30C in the original sealed pouch. Test Procedure: 1. Allow the test, specimen and or control to room temperature prior to the testing 2. Remove one test card from the pouch and place it on a clean flat surface 3. Using the dropper provided one drop of serum/plasma or W. blood sample (30ul) then two drops of buffer (40ul) immediately into the sample well. Avoid overflowing 4. Read results within 15 minutes. Strong positive reaction may visible within 5 minutes. Do not read results after 15 minutes. 5. If negative or quest Principle: AccuTest HCV Rapid Hepatitis C Virus Test (Serum/Plasma/Whole Blood) is a lateral flow chromatographic immunoassay based on the principle of the double antigen-sandwich technique. The membrane is coated with recombinant HCV antigen on the test line region of the device. During testing, the serum/plasma or W.Blood specimen reacts with HCV antigen coated particles. The mixture migrates upward on the membrane chromatographically by capillary action to react with recombinant HCV antigen or membrane and generate a colored line. Presence of this colored line indicates a positive result, while its absence indicates a negative result. To serve as a procedural control, a colored line will always appear at the control line region, indicating that the correct volume of specimen has been added and membrane wicking has occurred. Storage and Stability: AccuTest HCV should be stored at 4-30C. However, the card may be stored at room temperature not exceeding 30C in the original sealed pouch. Test Procedure: 1. Allow the test, specimen and or control to room temperature prior to the testing 2. Remove one test card from the pouch and place it on a clean flat surface 3. Using the dropper provided one drop of serum/plasma or W. blood sample (30ul) then two drops of buffer (40ul) immediately into the sample well. Avoid overflowing 4. Read results within 15 minutes. Strong positive reaction may visible within 5 minutes. Do not read results after 15 minutes. 5. If negative or questionable results are obtained, the HCV infection is suspected, the test should be repeated ona fresh serum specimen. Safety Information •Positive: If a distinct purple line is formed at the test one marked ‘T’ (Test Line) and the Control Zone marked ‘C’ (Control Line) the test result is positive, indicating the sample contains Hepatitis C antibody. The interpretation of test results (+ve for hepatitis) remains unchanged even if there is a difference in intensity of color in positive line and control line as is many a time found. •Negative: If a distinct purple line is formed only at the control zone marked ‘C’ (control line) the test result is negative • Invalid: A total absence of color in both © and (T) regions or no colored band appears on the control © region is an indication of procedure error and/or the test reagent has deteriorated. Repeat with a new test kit. Direction for Use Test Procedure 1. Allow the test, specimen and or control to room temperature prior to the testing 2. Remove one test card from the pouch and place it on a clean flat surface 3. Using the dropper provided one drop of serum/plasma or W. blood sample (30ul) then two drops of buffer (40ul) immediately into the sample well. Avoid overflowing 4. Read results within 15 minutes. Strong positive reaction may visible within 5 minutes. Do not read results after 15 minutes. 5. If negative or questionable results are obtained, the HCV infection is suspected, the test should be repeated ona fresh serum specimen. Other Info Storage and Stability AccuTest HCV should be stored at 4-30C. However, the card may be stored at room temperature not exceeding 30C in the original sealed pouch.

Send Message
product image
Rapid Test

Buy AccuTest H Pylori AB Rapid Card Test (50 Tests) Online from Accurex. The Helicobacter Pylori is a lateral flow chromatographic immunoassay for the qualitative detection of antibodies to H.pylori in human Whole Blood/Serum/Plasma. H Pylori test provides an aid in the diagnosis of infection with H.pylori. H.pylori is implicated in the etiology of a variety of gastrointestinal diseases, including duodenal and gastric ulcer, non-ulcer dyspepsia and active and chronic gastritis. h pylori symptoms are an ache or burning pain in your stomach (abdomen), Nausea, Loss of appetite, Frequent burping, Bloating & Unintentional weight loss NTENDED USE The H.pylori Antibody Rapid Test Card is a lateral flow chromatographic immunoassay for the qualitative detection of antibodies to H.pylori in human Whole Blood/Serum/Plasma. It provides an aid in the diagnosis of infection with H.pylori. INTRODUCTION H.pylori is implicated in the etiology of a variety of gastrointestinal diseases, including duodenal and gastric ulcer, non-ulcer dyspepsia and active and chronic gastritis. H.pylori infection is found in more than 90% of duodenal ulcer patients and in around 75% of all peptic ulcer sufferers. H.pylori infection is also more common in gastric cancer patients. The risk of gastric cancer has been estimated to be six-fold higher in H.pylori infected populations than in uninfected populations. H.pylori infections occur in human populations throughout the world. In developed countries, about 50% of the population may have H.pylori infection by the age of 60 years, while only 10-20% of adults in the third decade of life have it. Transmission is most probably by the fecal-oral or oral-oral route. Both invasive and non-invasive methods are used to diagnose H.pylori infection in patients with symptoms of gastrointestinal disease. Invasive methods include culture of gastric biopsy samples, histologic examination of stained biopsy specimens, or direct detection of the urease activity in the biopsy (CLO test). These methods need to obtain a biopsy sample by endoscopy.which is expensive,and usually results discomfort and risk to the patient.noninasive techniques include urea breath tests and serological methods. Urea breath test requires expensive laboratory equipment and moderate radiation exposure. Serologic tests are employed to detect antibodies as human immune response to H.pylori, for example the ELISA and the Western immunoblot. The H.pylori Antibody Rapid Test Card detect antibodies to H.pylori infection in human Whole Blood/Serum/Plasma. It is a noninvasive method and does not use radioactive isotopes. The test is easy to perform and requires no specialized equipment. Visual interpretation provides an accurate qualitative result. It is a useful on-site aid in the diagnosis of H.pylori infection. Diagnosis of H.pylori infection by antibody immunoassay can reduce the number of patients requiring endoscopy. PRINCIPLE The H.pylori Antibody Rapid Test Card is an immunoassay based on the principle of the double antigen-sandwich technique. During testing, a Whole Blood/Serum/Plasma specimen migrates upward by capillary action. The antibodies to H.pylori if present in the specimen will bind to the H.pylori conjugates. The immune complex is then captured on the membrane by the pre-coated H.pylori antigens, and a visible pink-purple line will show up in the test line region indicating a positive result. If antibodies to H.pylori are not present or are present below the detectable level, a pink-purple line will not form in the test line region indicating a negative result. To serve as a procedural control, a pink-purple line will always appear at the control line region, indicating that proper volume of specimen has been added and membrane wicking has occurred. Safety Information The H.pylori Antibody Rapid Test Card is limited to provide a qualitative detection. The intensity of the test line does not necessarily correlate to the concentration of the antibody in the blood. x The results obtained from this test are intended to be an aid in diagnosis only. Each physician must interpret the results in conjunction with the patient’s history, physical findings, and other diagnostic procedures. x A negative test result indicates that antibodies to H.pylori are either not present or at levels undetectable by the test. Direction for Use TEST PROCEDURE 1. Remove the test cassette from the sealed pouch and use it as soon as possible. 2. Place the test cassette on a clean and level surface. 3. For serum or plasma specimen: Hold the dropper vertically and transfer 3 drops of serum or plasma to the specimen well (S) of the test cassette, then start the timer. See illustration below. 4. For whole blood specimens: Hold the dropper vertically and transfer 1 drop of whole blood (approximately 30μl) to the specimen well(S) of the test cassette, then add 2 drops of buffer (approximately 70μl) and start the timer. 5. Read results at 15 minutes. Do not interpret the result after 20 minutes. Other Info STORAGE AND STABILITY x Store as packaged in the sealed pouch at 4-40℃. The kit is stable within the expiration date printed on the label. x Once open the pouch, the test should be used within one hour. Prolonged exposure to hot and humid environment will cause product deterioration.

Send Message
product image
Rapid Test

Intended Use The HIV TRI-DOT test is a visual, rapid, sensitive and accurate immunoassay for the differential detection of HIV-1 & HIV-2 antibodies (IgG,IgM & IgA) in human serum or plasma using HIV-1 & HIV-2 Antigens immobilized on an immunofiltration membrane. The test is a screening test for Anti HIV-1 and HIV-2 and is for in vitro diagnostic use only. Salient Features Rapid visual test ,based on Flow Through Technology. Differential detection of HIV-1 & HIV-2. Detection of group ‘O’ & subtype ‘C’. Use of envelop antigens gp41& C terminus of gp120 for HIV-1 & gp36 for HIV-2. 100% sensitivity & 100% specificity as per WHO Evaluation. Shelf life 24 months at 2-8°C Available in convenient pack sizes- 50 Tests and 100 Tests. Results within 3 minutes. No instrument required. In built quality control dot.

Send Message
product image
Rapid Test

Intended Use The Diagnos HIV BI-DOT Test is a visual, rapid, sensitive and accurate immunoassay for the detection of HIV-1 & HIV-2 antibodies (IgM,IgG & IgA) in human serum or plasma using HIV-1 & HIV-2 Antigens immobilized on an immunofiltration membrane. The test is a screening test for Anti HIV-1 and HIV-2 and is for in vitro diagnostic use only. Salient Features Rapid visual test ,based on Flow Through Technology. Detection of group ‘O’ & subtype ‘C’ strain of HIV-1 prevalent in Asian subcontinent. Use of Envelope antigen; gp41& C terminus of gp120 for HIV-1 & gp36 for HIV-2. Shelf life 24 Months at 2-8°C. Results within 3 minutes. No instrument required. In built quality control dot.

Send Message
product image
Glucometer

Product Name: FreeStyle Freedom Lite 100 Test Strips FreeStyle Lite test strips are specially designed for fast, easy testing and are intended to be used with FreeStyle Lite and FreeStyle Freedom Lite blood glucose monitoring systems only. Our patented ZipWik tabs break the surface of the blood sample for instant wicking action. Plus, there’s no coding required. Easy to Use · Patented ZipWik tabs target blood sample for easy application and fast uptake · No coding required means one less step Product Specification Minimum Order Quantity 1 Pack Product Description Product Name: FreeStyle Freedom Lite 100 Test Strips FreeStyle Lite test strips are specially designed for fast, easy testing and are intended to be used with FreeStyle Lite and FreeStyle Freedom Lite blood glucose monitoring systems only. Our patented ZipWik tabs break the surface of the blood sample for instant wicking action. Plus, there’s no coding required. Easy to Use · Patented ZipWik tabs target blood sample for easy application and fast uptake · No coding required means one less step Proven accuracy Patented ZipWik Tabs · Greater accuracy versus OneTouch Ultra2 and Contour systems1 · Minimizes interference from 22 common substances2 Minimizes Wasted Test Strips · Up to 60 seconds to reapply blood · Smallest sample size – uses just one-third the blood of OneTouch Ultra3 Contents: 2 x 50 Test Strips

Send Message
product image
Hemoglobin Meter

Buy Accurex H12 Hemoglobin Test Strips Online – for better result & accuracy. These Hemoglobin strips are used with URIT Hemoglobin Meter, for the quantitative measurement of total hemoglobin in capillary and venous whole blood. These hb strips are to be used by health care professionals only, not to be used for patient self-testing. Accurex HB Test Strips come with a pack size of 50 strips. The Accrues test strip utilizes Dry Chemistry Colorimeter Method (Azido methemoglobin Method). Meter’s optical detectors automatically measure the change in the membrane Buy Accurex H12 Hemoglobin Test Strips Online – for better result & accuracy. These Hemoglobin strips are used with URIT Hemoglobin Meter, for the quantitative measurement of total hemoglobin in capillary and venous whole blood. These hb strips are to be used by health care professionals only, not to be used for patient self-testing. Accurex HB Test Strips come with a pack size of 50 strips. The Accrues test strip utilizes Dry Chemistry Colorimeter Method (Azido methemoglobin Method). Meter’s optical detectors automatically measure the change in the membrane Operation Principle: The test strip utilizes Dry Chemistry Colorimeter Method (Azido methaemoglobin Method). When a drop of whole blood is applied to the test spot on the strip, blood immediately disperses within the membrane, contacting the reagent. The meter’s optical detectors avtomatically measure the change in membrane reflectance. The intensity of reflectance is inversely proportional to the hemoglobin concentration. Blood Sample Collection: Fresh or EDTA-anticoagulated capillary or venous whole blood may be used. If an EDTA – treated sample is refrigeratted to come to the room temperature before testing. EDTA treated blood samples should be mixed using end to and inversions at least 8 times prior to use, and should be tested within 24nours Do not use the haemolytic sample anticogulants other than EDTA are not recommended for use. Caution: 1. Same as all diagnostic tests, hemoglobin test results should be evaluated with the specific patient’s condition. Any results demonstrating the inconsistency with the patient’s clinical status should be repeated or supplemented with additional test data. 2. Do not touch the test membrane by hand 3. H12 Hemoglobin Test Strips are one-off product, do not use again Storage & Preparation: 1.H12 Hemoglobin Test Strips should be stored at O C-30 C dry and dark places, 2 C – B C is the best storage environment emperatures recommended. Keep away from direct sunlight and heat, must not be frozen, If the container was stored in refrigerated before first use, please don’t take it back into the refrigerator again after first use. 2. H12 Hemoglobin Test Strips are ready to use. No additional preparation is required 3. Enclosed desiccants with lest strip. Remove only those strips needed for testing. The remaining lest strips should be resealed in their onginal container and used up in 3 months after first use. Do not use lest strips and throw away alter expiry date. 4. Use the strip immediately once taking it out af the container, otherwise the result will be incorrect 5. Do not fold or cut the test strip. 6. Used lest strips cannot be used again, dispose them as normal medical waste Direction for Use Operating Instructions: 1. URIT Hemoglobin Meter, H12 Hemoglobin Test Strip, Lancing Device, and disposable blood taking needle. 2. Test steps: 1) Turn the meter on and input the Code Card. Check the Code Card displaying on the meter to ensure it to match the Code Card printed on the lest strip container. Otherwise, the result is incorrect. 2) Massage the patient’s finger from the knuckle up to the tip to stimulate blood flow. Clean the sample area with alcohol and wipe it dry with a sterile gauze pad. 3) Insert the lest strip into the strip holder with the notched end in first and the hole facing up. 4) Puncture the skin on the lower side of fingertip with blood collection needle, and remove 13-15 TIL of whole biood with capillary or other micro blood collection apparatus. While waiting for the instrument to display the blood drop symbol, quickly add the drops to the test hole on the reagent sheet. Please make sure that the blood drop volume can completely cover the test hole but not overflow the test hole. 5) The meter starts the test automatically after the blood sample disperses Once the lest is in process do nol disturb or move the meter or test strip, or press any key. The test result will display within 12 seconds. Qualtiy Control Procedure: Use only H12 Hemoglobin Test Strip with QC substance to perform QC. The range of QC substance is the numerical range indicated on the label of the QCsubstance or test strips. When to do a QCtest: 1. Whenever you suspect that the meter or test strips are not working properly. 2. If your hemoglobin test results are not consistent with how you feel. Other Info Limitations of test Method: H12 Hemoglobin Test Strip is only suitable for testing fresh or whole capillary blood or whole venous blood containing EDTA anticoagulants. Do not use serum, plasma or arterial blood

Send Message
product image
Hemoglobin Meter

Get the fastest hemoglobin and HCT test within 10 seconds, Buy Accurex URIT-12 Hemoglobin Meter Online. This Hemoglobin tester gives Accurate & Reliable Result. The Urit 12 hemoglobin machine is the best digital hemoglobin Meter with easy 3-step operation. The hb meter is is perfectly fit for the filtration of the numbers of blood donors, POCT, and hemoglobin testing in medical examination center. etc. It works on the prinicple of Optical reflectance. Sample: Capillary or venous whole blood (13~15 ul) & Strips: Accurex H12 Hemoglobin Test Strip URIT-12 is an easy-operation, fast-testing and portable hemoglobin testing Meter, which is perfectly fit for the filtration of the numbers of blood donors, POCT, and hemoglobin testing in medical examination center (MEC) etc. Compared to HiCN-HB method, the results are satisfactory. • Fast hemoglobin and HCT test within 10 seconds • Accurate & Reliable Result • Easy 3-step operation Parameter: Hemoglobin, HCT (Hematocrit) Principle: Optical reflectance Strip: H12 Hemoglobin Test Strip Speed: 10 seconds Sample: Capillary or venous whole blood (13~15 ul) Memory: 250 test results Measuring Range: 4.0g/dL 24.0g/dL(g/L optional) Quality Control: HQ-A Hemoglonbin control solution Calibration: Factory calibrated according to ICSH Power: DC 6V (Two CR2032 Batteries) Automatization: Self-checking, auto-judging and displaying malfunction Dimension: 102mm 50mm 19mm Accuracy: accuracy ≥ 96%,the correlation is very good in the comparison between URIT-12 and ICSH method. Precision: CV < 5%,testing samples including high, medium & low concentration, the CV of 10 repeated test results is 1.8% 2.2% 2.7% respectively. Hematology analyzer is not suitable for the fast and single hemoglobin testing out of the laboratory and the fast hemoglobin filtration for numbers of blood donors, therefore, it’s very necessary to find a kind of method for fast and accurate hemoglobin testing. When a drop of whole blood is applied to the test spot on the strip, blood immediately disperses within the membrane, contacting the reagent. The meter’s optical detectors automatically measure the change of reflectance in membrane. The intensity of reflectance is inversely proportional to the hemoglobin concentration. Other Info Hemoglobin testing is one of the important clinical hemanalysis items. It is useful for the diagnosis of all kinds of anemia. In clinical laboratory, many test items including hemoglobin can be gotten from hematology analyzer.

Send Message

Still searching for
membrane wicking?