Jaipur
+918529833535

'measurement monitoring'

Items tagged with 'measurement monitoring'

product image
Glucometer

SD CodeFree A representative model of of SD BIOSENSOR which is easy to use and provides accurate results without the need for coding. The SD Codefree Blood Glucose Meter is a compact, hand-held, and easy-to-read monitor that stores up to 500 test results. It provides an accurate picture of your blood glucose level at the time of the test from a small droplet of blood. Specification Enzyme Glucose Oxidase biosensor Measurement Range 10 - 600mg/dL (0.6 - 33.3 mmol/L) Specimen volume 5 sec Sample Volume 0.9 µl Hematocrit 20 - 60% Unit mg/dL Memory Up to 500 tests Battery 3V battery (CR2032) Interpretation of results Cat. No. Product Component Note 01GC110 SD CodeFree™ Blood Glucose Monitoring System Meter, Test Strip (10EA) / Lancet(10EA) / Lancing Device / Check Strip 01GS11 SD CodeFree™ Blood Glucose Test Strip SD CodeFree™ Test Strip (25EA x 2 bottle)

Send Message
product image
Clinical Chemistry

ADVIA 2400 Chemistry System The right balance of speed and efficiency The ADVIA® 2400 Clinical Chemistry System manages the most demanding workloads and meets high turnaround-time (TAT) goals. Its menu includes methods for testing drugs-of-abuse, therapeutic drugs (TDM) and new assays such as cystatin C and CardioPhase® hsCRP. The ADVIA 2400 Clinical Chemistry System offers: High throughput of up to 2400 tests/hour (1800 photometric and 600 ISE) to manage heavy workloads Rapid, consistent, 2-second cycle time for faster tube speed and test throughput User-defined automatic repeat, dilution, and reflex testing Large onboard reagent capacity and optional concentrated reagents help to minimize intervention demands Refrigerated onboard storage of controls and reagents for extended stability and increased productivity Automation-ready design: no additional hardware required Features & Benefits The ADVIA 2400 Clinical Chemistry System meets today’s high turnaround-time goals with a throughput of up to 2400 tests/hour. In addition to assays for general and specialty chemistries, its menu includes assays for specific protein measurement, drugs-of-abuse testing (DAT), and therapeutic drug monitoring (TDM). Interesting new assays such as cystatin C, HbA1c with automated sample pretreatment, and CardioPhase® hsCRP can now be included in your routine testing. The ADVIA 2400 Chemistry System pushes productivity levels while maintaining the reliability and stability that keep laboratories up and running. A rapid, 2-second probe cycle time maximizes tube speed and test throughput and combines with the system’s efficient automation-readiness to provide the turnaround time needed for high-volume laboratories Superior Speed and Productivity Throughput of up to 2400 tests/hour (1800 photometric and 600 ISE) to manage the heaviest workloads Rapid, consistent, 2-second cycle time Throughput of 200 tubes per hour, even when running three ISE tests and nine photometric tests per sample Automatic Sample Retain technology, auto-repeat, auto-dilution, and auto-reflex testing Automation-ready Point-in-space aspiration enables connectivity to a track. Redundant sample loading provides built-in backup and easy handling of non-routine samples. Direct sampling from track prevents tubes being detained at an analyzer and reduces aliquoting. Minimal Need for Operator Intervention Minimal-maintenance ISEs Large onboard reagent capacity and optional concentrated reagents for fewer interruptions No-maintenance, 37°C incubation oil bath Auto-calibration and auto-QC from refrigerated onboard calibrators and controls Microvolume technology with 32,000 tests onboard and up to 60 days' onboard stability for improved walkaway time. Concentrated reagents for increased maximum capacity. Remote diagnostics and Inter-Laboratory Quality Control (ILQC) options Exceptional Reliability Sample integrity check for icterus, hemolysis, and lipemia Sample probe with automatic clot/clog detection, liquid-level sensing, short-sample detection, and crash protection Advances in onboard reagent stability, calibration frequency, reduction in interferences, and expanded assay linearity

Send Message
product image
Medical Equipment

In compliance with out-of-hospital patient transport standards such as EN1789, EN13718-1, IEC60601-1-12 and U.S. military standards, N1 is a highly competent solution for various out-of-hospital transport settings both on land and in air. The N1's exceptional reliability and strong performance enhance your confidence to provide seamless patient care during transport no matter intra or out of hospital. One monitor, Multiple solutions Mirror Mode Two-way screen or remote control functionality and viewing on both the 19" external display and the N1 unit - simultaneously. benevision-n1-fig2-2-pc BeneVision N1 as a Transport Monitor Enhanced data analysis greatly improves parameters' accuracy and anti-interference ability. Its fully integrated sidestream CO2 module monitors the patient's breathing situation by connecting with sampling line directly, freeing caregivers from the shackles of expanding external modules for transport. One monitor, Multiple solutions Mirror Mode Two-way screen or remote control functionality and viewing on both the 19" external display and the N1 unit - simultaneously. benevision-n1-fig2-2-pc BeneVision N1 as a Transport Monitor Enhanced data analysis greatly improves parameters' accuracy and anti-interference ability. Its fully integrated sidestream CO2 module monitors the patient's breathing situation by connecting with sampling line directly, freeing caregivers from the shackles of expanding external modules for transport. benevision-n1-fig2-1-pc BeneVision N1 as a Multi-Parameter Module Slide directly into the module slot or SMR of the N-Series monitor providing an expansive set of parameter measurements. When combined with our additional advanced parameter modules, this solution fits even the highest level of critical care environments. benevision-n1-fig2-3-pc Companion Mode Connect with N-Series host monitor via cable connection to N1 dock and have the ability for dual-screen monitoring and bi-directional control of the bedside monitor - expanding slot space for more advanced parameters and enhanced ICU workflow. Patient-Centric Data Collection When connected to a bedside patient monitor, advanced parameters collected from the host monitor such as AG and BIS, etc., will also be stored in N1 with trend data and alarm events reviewable even when it is disconnected.

Send Message
product image
Medical Equipment

With state-of-the-art screen technology, BeneVision N Series patient monitors deliver clear, multi-color, wide-format displays for users to capture and review information at a glance. With multi-touch operation, users can control the monitor and review patient data quickly and easily. BeneVision N Series provides the world's best monitoring technologies for you, with new applications being developed. Perfect hemodynamic monitoring solution, not only provides a variety of measurement methods, ICG, PiCCO, ScvO2, C.O., but also provides comprehensive analysis tool – HemoSight™. HemoSight™ focuses on hemodynamic treatment process, and provides appropriate tools for each stage. Advanced modular regional tissue oxygenation measurement -- INVOS rSO2. Volumetric capnography & metabolic measurement help to evaluate the adequacy of ventilation and determine the ventilator setting effectively, and improve the safety of weaning and extubation. Powerful Clinical Assistive Applications (CAAs) to support efficient decision making when time is critical. Each CAA focuses on major clinical workflow challenges that individual departments face. Solutions optimized for each point of care At every point of care, such as ICU, CCU, NICU, OR, PACU, ER, BeneVision N Series patient monitors always provide a suitable solution to meet your clinical needs for monitoring your patient's status anywhere, anytime, even on your way through mobile devices. With excellent transport solution, BeneVision N Series patient monitor brings a smooth workflow and safe data management through the entire care process. BeneVision takes less time to operate, and helps you understand the patient's variables quickly. With HL7,BeneVision N Series patient monitors can directly connect to the hospital clinical network.BeneVision N12 is capable of monitoring multiple parameters simultaneously both at bedside and during transport. IT structure designed for seamless connectivity Mindray patient monitoring system incorporates extensive network adaptability to integrate with the hospital's current network infrastructure, ensuring that critical data is on hand for clinical decision making - and is integrated with the patient record. Mindray's central station and eGateway further enhances the connectivity of BeneVision to your clinical world. Bedside devices data and other clinical systems data are shared to support your diagnosis and clinical decisions.

Send Message
product image
Medical Equipment

Mindray believes the best way to predict the future is to create it. The revolutionary BeneVision N22/N19 is designed to optimize user experience by satisfying all your clinical demands. With visionary-stimulating design, benchmarking ease of use, confidence-maximizing innovations and workflow-transforming interoperability, BeneVision N22/N19 is creating tomorrow’s monitoring perspective today. The design excellence of BeneVision N22/N19 has great originality to lead your perspective. A seamless outlook optimizes your monitoring experience with super large touchscreen, cool rotatable landscape & portrait layout, ultra slim main unit as well as plug-n-play modules. An ingenious user interface including multi-window flat menus, infographic alarm indications and online user guide offers extremely intuitive patient data and ultimate ease-of-use, while auto screen brightness always keeps patient in mind. Benefitting from cutting-edge clinical measurements, such as rSO2, ICG, PiCCO, AG, RM, BIS, NMT, and state-of-art clinical decision support tools, such as HemoSightTM, ST GraphicTM, DSA, BeneVision N22/N19 enhances your clinical confidence to the max and helps you make easier and faster clinical decisions. The connectivity capabilities of BeneVision N22/N19 fit seamlessly into your clinical workflow for paperless future. Revolutionary iView clinical informatics workstation brings all intelligence (PACS, LIS, EMR, etc) on screen at point of care for one-stop diagnosis. Industry-leading BeneLink integrates all bedside devices to the monitor realtimely and facilitates centralized data management.

Send Message
product image
Laboratory Testing Analyzer

The ADAMS A1c, HA-8180 is a fully automated Glycohemoglobin (HbA1c) analyzer based on HPLC (High Performance Liquid Chromatography). HbA1c is a good parameter for long-term blood glucose monitoring in patients suffering from diabetes mellitus. Measurement Speed: 48 sec/test for Fast Mode and 90 sec/test for Variant mode. Measurement items are as follows. HA-8180V, Fast Mode HbA1c (Stable HbA1c, S-A1c) and HbF HA-8180V, Variant Mode  HbA1c (Stable HbA1c, S-A1c) and HbF HbS and HbC separation and HbE and HbD detection can be performed. ・Column design with no more pre-filter change ・Economical - improved aluminium reagents for more efficient reagent supply ・Color LCD with reagent level, graphs on screen Specifications Configuration Main body, sampler (with sample tube spinning unit) and accessories Measurement objects Whole blood or hemolysis sample Column COLUMN UNIT 80 Reagents ELUENT 80A, ELUENT 80B, ELUENT 80CV and HEMOLYSIS WASHING SOLUTION 80H Measurement items Fast Mode HbA1c (Stable HbA1c, S-A1c) and HbF Variant Mode HbA1c (Stable HbA1c, S-A1c) and HbF (HbS and HbC separation and HbE and HbD detection can be performed) Measurement ranges *1 HbA1C: 3 - 20%, 9 - 195 mmol/mol HbF: 0 - 100% Guaranteed measurement ranges *2 HbA1C: 4 - 16%, 20 - 151 mmol/mol HbF: 0.3 - 5% Measurement principle Reversed-phase cation exchange chromatography Measurement wavelength 420 nm / 500 nm (Dual-wavelength colorimetry) Sample supply Sampler Resolution 0.1 % Ratio, 1 mmol / mol Processing speed Variant mode : 90 seconds / test Fast mode : 48 seconds / test Sample consumption Approximately 14 μL (Whole blood) Required sample volume Sample tube : Minimum 10 mm away from the bottom Sample cup : 400 μL or more Sample container Sample tube : (12.3/15 mm diameter) × (75 to 100 mm length) Sample cup: 500 μL Compatible rack type ARKRAY racks Number of measurement samples One-way transportation (factory-set) : Maximum 50 samples Loop transportation : Maximum 100 samples Column temperature Approximately 40°C Warm-up time Maximum 30 minutes Display Large color LCD with backlight Printer For use with 58-mm width thermal printer paper Memory capacity 900 measurement results (including calibration results) External output Serial 1 port (Can be optionally used as an Ethernet port.) Communication system RS-232C compliant (Switchable between one-way and two-way communications.) Transmission speed RS-232C : Selectable from 300, 600, 1200, 2400, 4800, 9600 and 19200 bps Ethernet: 10BASE-T Dimensions 530 (W) × 530 (D) × 530 (H) mm (Not including the hemolysis washing solution bottle) Weight Main body: Approximately 39 kg, Sampler: Approximately 4 kg Power requirements 100 - 240 V AC ± 10 %, 50 / 60 Hz Power input Maximum 300 VA *1 Error-free measurement ranges *2 Guaranteed ranges for obtaining results equivalent to those from HA-8160 VP mode measurement

Send Message
product image
Glucometer

STANDARD GlucoNavii Pro BT It can measure blood glucose through venous, capillary, arterial blood and as well as neonatal blood using GDH-FAD enzyme.. Its Easy Light™ function helps the user check the glucose level through the LED light and the ejector allows an easier removal of the strip. By using Bluetooth(BLE), it helps manage blood glucose levels through smart devices. Advantage Blood glucose data transfer using NFC and Blootooth(BLE) communication technology GDH-FAD enzyme (Capillary, Venous, Arterial and Neonatal blood available) No Coding Fasting, Pre & Post Meal Mark Wide Hematocrit Range(0~70%) Strip Ejection Function Easy Light™(Glucose level indicaitor) Specification Enzyme Glucose Dehydregenase-FAD biosensor Measurement Range 10 - 600mg/dL (0.6 - 33.3 mmol/L) Test Time 5 sec Sample Volume 0.5 µl Hematocrit 0 - 70% Unit mg/dL Memory Up to 1,000 tests Battery 3V battery (CR2032) Interpretation of results Cat. No. Product Component Note 01GC610 STANDARD™ GlucoNavii® PRO Blood Glucose Monitoring System Meter, Meter, Test Strip (10EA) / Lancet(10EA) / Lancing Device 01GS60 STANDARD™ GlucoNavii® PRO Blood Glucose Test Strip STANDARD™ GlucoNavii® PRO Test Strip (25EA x 2 bottle) Download

Send Message
product image
Glucometer

STANDARD GlucoNavii Pro It can measure blood glucose through venous, capillary, arterial blood and as well as neonatal blood using GDH-FAD enzyme.. Its Easy Light™ function helps the user check the glucose level through the LED light and the ejector allows an easier removal of the strip. Advantage GDH-FAD enzyme (Capillary, Venous, Arterial and Neonatal blood available) No coding Fasting, Pre & Post Meal Mark Wide Hematocrit Range (0~70%) Strip Ejection Function Easy Light™ (Glucose level indicaitor) Specification Enzyme Glucose Dehydregenase-FAD biosensor Measurement Range 10 - 600mg/dL (0.6 - 33.3 mmol/L) Test Time 5 sec Sample Volume 0.5 µl Hematocrit 0 - 70% Unit mg/dL Memory Up to 1,000 tests Battery 3V battery (CR2032) Interpretation of results Cat. No. Product Component Note 01GC610 STANDARD™ GlucoNavii® PRO Blood Glucose Monitoring System Meter, Test Strip (10EA) / Lancet(10EA) / Lancing Device 01GS60 STANDARD™ GlucoNavii® PRO Blood Glucose Test Strip STANDARD™ GlucoNavii® PRO Test Strip (25EA x 2 bottle)

Send Message
product image
Glucometer

STANDARD CodeFree Plus SD Codefree plus is an easy and simple blood glucose monitor that intuitively tells the user if the blood glucose level is low, on target or high with LED light and beep sound. Advantage Intuitive notification of result with LED light and beep sound No coding SD CodeFree test strips can be shared with other devices Specification Enzyme Glucose Oxidase biosensor Measurement Range 10 - 600mg/dL (0.6 - 33.3 mmol/L) Test Time 5 sec Sample Volume 0.9 µl Hematocrit 20 - 60% Unit mg/dL Memory Up to 100 tests Battery 3V battery (CR2032) Interpretation of results Cat. No. Product Component Note 01GC50 STANDARD™ CodeFree® Plus Blood Glucose Monitoring System Meter, Test Strip (10EA) / Lancet(10EA) / Lancing Device / Check Strip 01GS50 STANDARD™ CodeFree® Plus Blood Glucose Test Strip STANDARD™ CodeFree® Plus Test Strip (25EA x 2 bottle)

Send Message

Still searching for
measurement monitoring?