Jaipur
+918529833535

'measurement accuracy'

Items tagged with 'measurement accuracy'

product image
Medical Equipment

Since the company was founded, Mindray has been continuously exploring new ways to improve diagnostic confidence. Powered by the most revolutionary ZONE Sonography® Technology, Resona 7’s new ZST+ platform brings ultrasound image quality to a higher level by zone acquisition and channel data processing. As well as the premium level image quality, Resona 7 also enhances clinical research capabilities with the revolutionary V Flow for vascular hemodynamic evaluation, and the most intelligent plane acquisition from 3D datasets for fetal CNS diagnosis. Combining the most intuitive gesture-based multi-touch operation and all the essential clinical features, Resona 7 is truly leading new waves in ultrasound innovation. With core platform advantages of ZST+ The channel data based ZST+ is an extraordinary innovation, representing an ultrasound evolution. Transforming ultrasound metrics from conventional beamforming to channel data based processing, ZST+ is able to deliver multiple imaging advances: Advanced Acoustic Acquisition, Dynamic Pixel Focusing, Sound Speed Compensation, Enhanced Channel Data Processing and Total Recall Imaging. Advanced features V Flow V Flow (Vector Flow) is a novel approach for vascular hemodynamic analysis. V Flow uses color coded vector arrows to indicate the velocity’s magnitude and direction of blood cells. With ultra-high frame rates, it provides extremely accurate and angle-independent visualization of complex vascular hemodynamic profiles. With comprehensive data information, V Flow is the most valuable tool for vascular clinical research. resona-7-fig3-1-pc UWN+ Contrast Imaging UWN+ (Ultra-Wideband Non-linear Plus) CEUS enables the Resona 7 to detect and utilize both the 2nd harmonic and non-linear fundamental signals, generating significantly enhanced images, resulting in greater sensitivity of minor signals and longer agent duration with lower MI. Forwarding smart to clinical intelligence The Resona 7 elevates clinical intelligence with a complete solution that enables clinicians to manage both routine and advanced studies more efficiently,consistently, and accurately, from acquisition to calculation. As an example, Smart Planes CNS shows exceptional intelligence in accurate diagnosis and analysis of the fetal central nervous system (CNS) Smart Planes CNS Mindray’s exclusive pioneering technology positions the Resona 7 as the industry’s first ultrasound system to allow fully automatic and accurate detection of the most significant planes and frequently used measurements of fetal CNS, leading to intelligent diagnosis, improved throughput, and reduced user dependence. Smart Planes CNS provides a user-friendly tool that greatly improves scanning efficiency through increased accuracy coupled with automated operation. With a simple button click on a 3D fetal brain volume image, the standard CNS scanning planes (MSP, TCP, TTP and TVP) and a range of related anatomical measurements (BPD, HC, OFD, TCD, CM and LVW) are obtained immediately. Smart Face Acquiring an optimal view of the fetal face in 3D ultrasound is cumbersome and time-consuming. In some cases, it is impossible to get rid of the occlusions such as cord, placenta, uterus and extremities. The new Resona 7 with Zone Intelligence provides a fast and intelligent optimization for fetal face with simply one-touch. It can immediately remove occlusions in the volume data, eliminate unwanted noise information, and generate an optimal view of the fetal face with minimal effort. Ergonomics The Resona 7 is designed around you. Gesture-based operation opens up a new trend in cart-based ultrasound with an agile, smart, and intuitive user experience beyond your expectations. Gel warmer’s three level temperature and swiveling angle adjustment of the control panel delivers great patient comfort and user convenience.

Send Message
product image
Medical Equipment

In compliance with out-of-hospital patient transport standards such as EN1789, EN13718-1, IEC60601-1-12 and U.S. military standards, N1 is a highly competent solution for various out-of-hospital transport settings both on land and in air. The N1's exceptional reliability and strong performance enhance your confidence to provide seamless patient care during transport no matter intra or out of hospital. One monitor, Multiple solutions Mirror Mode Two-way screen or remote control functionality and viewing on both the 19" external display and the N1 unit - simultaneously. benevision-n1-fig2-2-pc BeneVision N1 as a Transport Monitor Enhanced data analysis greatly improves parameters' accuracy and anti-interference ability. Its fully integrated sidestream CO2 module monitors the patient's breathing situation by connecting with sampling line directly, freeing caregivers from the shackles of expanding external modules for transport. One monitor, Multiple solutions Mirror Mode Two-way screen or remote control functionality and viewing on both the 19" external display and the N1 unit - simultaneously. benevision-n1-fig2-2-pc BeneVision N1 as a Transport Monitor Enhanced data analysis greatly improves parameters' accuracy and anti-interference ability. Its fully integrated sidestream CO2 module monitors the patient's breathing situation by connecting with sampling line directly, freeing caregivers from the shackles of expanding external modules for transport. benevision-n1-fig2-1-pc BeneVision N1 as a Multi-Parameter Module Slide directly into the module slot or SMR of the N-Series monitor providing an expansive set of parameter measurements. When combined with our additional advanced parameter modules, this solution fits even the highest level of critical care environments. benevision-n1-fig2-3-pc Companion Mode Connect with N-Series host monitor via cable connection to N1 dock and have the ability for dual-screen monitoring and bi-directional control of the bedside monitor - expanding slot space for more advanced parameters and enhanced ICU workflow. Patient-Centric Data Collection When connected to a bedside patient monitor, advanced parameters collected from the host monitor such as AG and BIS, etc., will also be stored in N1 with trend data and alarm events reviewable even when it is disconnected.

Send Message
product image
Instruments

The new and improved RTR-1 uses an image processing method. During measurement, the lateral flow device is captured using a 5-mega pixel camera and the picture is analyzed using image processing algorithms for identification of either presence or absence of test line bands or test line band intensity levels. The reader converts the image into a grayscale and then classifies the intensity levels of the image in 0 to 255 grayscale range. The image processing algorithm undergoes various levels of filtering and segmentation to yield the correct intensity levels from the picture. Based on the preconfigured intensity levels, the reader classifies the band intensity and reads out the results as either positive or negative. ACCURACY: Less than 3% intra-run CV Eliminates subjective interpretation by operator FLEXIBILITY: Single mode for low volume test setting Batch mode allows for high volume test setting Result output as semi-quantitative line intensity and visual image EASE-OF-USE: Built in barcode reader provides faster test setup Touch screen interface for easy operation Lightweight (0.7kg) and portable DATA MANAGEMENT: Results presented on screen, on a printout or uploaded to reader database Storage capacity of 1,000 test results (including images) Laboratory Information System (LIS) and Wi-Fi compatible Human Machine Interface 4-inch resistive touch screen Camera 5 mega pixel CMOS camera Barcode Scanner Integrated 1 dimensional barcode scanner Printer 48 mm inbuilt thermal printer Mode Single mode and batch mode operations Port/USB Data export and software upgrade through 2 USB ports Storage Storage capacity of 1000 test results (including images) Result output “Positive or Negative” as well as quantitative test line intensity Power 12V 2A Processor ARM Cortex-A53 Platform Embedded Linux Dimension 220 mm X 170 mm X 110 mm (L x B x H) Weight 0.7 kg (Approx CATALOG # PRODUCT RTR-1 Rapid Test Reader OTHER PRODUCTS YOU MIGHT BE INTERESTED IN.. CATALOG # PRODUCT ADX-110 ELISA Reader ADX-120 Microplate Washer

Send Message
product image
Laboratory Usage

Soil moisture meter TDR 150 Portable soil moisture meter allows you to obtain readings on the go at the press of a button. Variable rod length options provide soil moisture measurements at your ideal root zone. With new enhancements, the TDR 150 provides significant improvements in performance and measurement accuracy for optimal turf and soil environments. Increased accuracy of soil moisture (Volumetric Water Content) Measures EC (Electrical Conductivity) Measures Turf Surface Temperature Option to add on Bluetooth and GPS Data logger records approximately 50,000 measurements Industry exclusive backlit display Ergonomic handle Data collected with USB flash drive No PC interface needed Powered by AA lithium batteries Ideal for measuring containers on benches Optional IR Temp sensor to measure canopy TDR 150 SPECIFICATIONS Measurement Principle: Time - domain measurement methods Measurement Units: Percent Volumetric Water Content (VWC) Resolution: 0.1% VWC Accuracy: +- 3.0% VWC with Electrical Conductivity (EC) < 2 mS/cm Range: 0% to saturation (Saturation up to about 50% volumetric water depending on soil type) Battery/Life: 4 AA lithium batteries; approximately 100,000 readings without backlight Data Logger: 50,000 measurements EC Range: 0 to 5 mS/cm, Resolution: 0.01 mS/cm, Accuracy: +/- 0.1 mS/cm Temperature Range: -30°C to 60°C, Resolution: 0.1°, Accuracy: +/- 1°C

Send Message
product image
Laboratory Usage

TACHOMETER/STROBOSCOPE, Model : BP-2259 ( 2 in 1, DIGITAL PHOTO TACHOMETER with DIGITAL STROBOSCOPE ) FEATURES* Intelligent, microprocessor circuit design, high accuracy, wide range, digital readout.* One instrument include two functions of " Digital Photo Tachometer " & " Digital Stroboscope "* Digital Stroboscope :Wide setting range from 100 RPM to 100,000 RPM, digital display with high accuracy. Modern solid state high visible orange light, long life, almost maintenance free. It is ideal for inspectingand measuring the speed of moving gears, fans, centrifuges, pumps, motors and other equipment used in general industrial maintenance, production, quality control, laboratories and as well as for schools and colleges for demonstrating strobe action.* Digital Photo Tachometer :No contact RPM measurement, wide measuring range from 0.5 to 100,000 RPM. 0.1 RPM resolution for the measured value < 1000 RPM. The last value, max., value, min. value can be stored into the memory automatically & be obtained by pressing " Memory Call Button ". High visible LCD display gives RPM reading exactly with no guessing or errors.* The use of durable, long lasting components, including a strong, light weight ABS plastic housing.Cabinet has been carefully shaped to fit comfortable in either hand. GENERAL SPECIFICATIONS Display 5 digits, 10 mm ( 0.4" ) LCD Operation 0 - 50 (32 - 122 ). ( Liquid Crystal display ) with Temperature function annunciation. Operating Less than 80% RH.Accuracy ± ( 0.1 % + 2 digit ). Humidity Sampling Time 1 second ( 60 RPM ). Size 215 x 65 x 38 mm.Time base:Quartz crystal. (8.5 x 2.6 x 1.5 inch). Circuit Exclusive one-chip design Weight 300g(0.66 LB)/including battery.microprocessor LSI circuit. Accessories : Carrying case ................... 1 PC.Battery 4 x 1.5V AA ( UM-3 ) battery. Operation manual ..............1 PC.ELECTRICAL SPECIFICATIONS ( PHOTO TACHOMETER )Measurement Range 5 to 99,999 RPM Resolution 0.1 RPM ( < 1,000 RPM ) 1 RPM ( 1,000 RPM )Photo Tach. detecting distance 50 to 150 mm/2 to 6 inch. * Typical max. 300 mm/12 inch depending upon ambient light.ELECTRICAL SPECIFICATIONS ( STROBOSCOPE )Stroboscopic 100 to 100,000 FPM/RPM Flash tube High efficiency orange LED Flash Rate FPM: flash per minute lamp.RPM : round per minute Flash Duration Approximately 60 to 1,000Flash Adjust 3 ranges : microseconds. Range Range A: 100-1,000 FPM Flash color Orange Range B: 1,000-10,000 FPM Flash Duration Approx. 16% of period time. Range C: 10,000-100,000 FPM Flash Adjust Coarse adjust knob and Resolution 0.1 FPM/RPM. Knob Fine adjust knob.(Less than 1,000 FPM/RPM) Calibration Crystal time base and1 FPM/RPM microprocessor circuit, don't(Over 1,000 FPM/RPM) necessary take any external calibration process. OPERATIONS PROCEDURES ( STROBOSCOPE )Preparation Determine the range switch to " 1000 RPM " ," 10,000 RPM " or" 100,000 RPM " position.Checking When checking speed, care must be taken to insure that the strobe is flashing in Speed unison (one to one) with the object being monitored. A Stroboscope will also stop motion at 2:1, 3:1, 4:1 et., this is normally referred to as harmonies. To be sure of unison, turn the dial until two images appear - this will double the actual speed. Then lower the flashing rate until a single and stationary image appears -this is the actual true speed.Checking For motion analysis, simply locate the actual speed as mentioned above and then Motion turn the dial slowly up or down. This will give a slow motion effect allowing complete inspection.

Send Message
product image
Distance Meter Digital

Product Details: Weight 305 g Model No GM-06 Measuring Geometry 60 Degrees Power Supply Batter, 4 X 1.5 VA Display 4 digits backlit LCD Range 0.1 to 200 gloss units We are offering Digital Gloss Meter which is widely used in Floor maintenance, Surface cleaning quality control, Stone and tile gloss measurement, Checking printed matter, Quality control of paint and ink, Polished metal surface , measurement (chrome plating), Inspection of paint protection and waxing, Auto-body paint inspection,Surface inspection of plastic moldings, Evaluation of detergents and washers,Checking masonry and washers, Checking building exteriors. Specifications: Accuracy: ±1.0 gloss unit ( against reference standard ) Resolution: 0.1 gloss unit Repeatability: ±0.5 GU(0 ... 99.9) Measuring Area: mm ellipse Data Memorized: groups Data Output: RS 232 C serial interface Dimensions: Main unit: 156 x67x28 mm Separate Sensor: 58x28x108 mm Weight : About 305g ( including fitted batteries ) Working condition: Temperature range 0 - 40¿¿¿ and Humidity up to 85%.

Send Message
product image
Laboratory Testing Analyzer

For smaller Laboratories Smaller, but with full functionality Compact size Full functions and performance in a compact size. *Size comparison with HA-8180V Accuracy HPLC technology provides accurate results-inluding detailed chromatogram. it will be shown in both IFCC and NGSP units. Cap-piercing method ADAMS Lite uses a cap-piercing method which enables the placement of capped blood samples. This not only reduces the workload but also helps protect lab technicians from infection. Easy-to-maintain No special tools are required for daily maintenance. Exchanged parts are hand-tightened, minimizing the workload of users. Specifications Measurement objects Whole blood or hemolysis sample Measured items Fast Mode: HbA1c (Stable HbA1c, S-A1c) and HbF Variant Mode: HbA1c (Stable HbA1c, S-A1c) and HbF (HbS and HbC separation and HbE and HbD detection can be performed). Measurement principle Reversed-phase cation exchange chromatography Measurement wavelength 420 nm/500 nm (Dual-wavelength colorimetry) Resolution 0.1% Ratio, 1 mmol/mol Measurement range HbA1c: 3 - 20%, 9 - 195 mmol/mol HbF: 0 - 100% Processing speed Variant mode: 160 seconds/test Fast mode: 100 seconds/test Sample consumption Whole blood sample: Approximately 4µL Anemia sample: Approximately 8 µL Hemolysis sample: Approximately 350 µL Sample container Sample tube: (12.3 or 15 mm in outer diameter) × (75 to 100 mm in height) Sample cup: 500 µL Sample supply Piercing sampling Compatible rack type ARKRAY racks (for 5 samples) Operating environment Temperature: 10 - 30°C; Humidity: 20 - 80% RH (No condensation) Display 20 digits × 2 lines LCD Printer For use with 58-mm width thermal printer paper Number of measurement samples Maximum 10 samples Power requirements AC 100 - 240 V±10%, 50/60 Hz Dimensions 330 (W) × 515 (D) × 485 (H) mm (Not including protrusions, eluent packs and hemolysis washing solution bottle)

Send Message
product image
Hematology

Product Description AutoCell Plus 3 Part WBC Differential Automated Hematology Analyzer Large Touch Screen Display Easy analysis of patient data on single screen ensuring efficient work-flow 10.4" color touch-screen Data + Hitogram Based Result 20 parameters numerical data 8 3 histo grams Results are displayed as group of "data + histogram" for each parameter enabling easier correlation. Dual Sample Mode Ft Small Sample Volume Just 9 pL whole blood required for test - Very useful for pediatric & geriatric patients where sample collection may be very difficult 20 pL Pre-dilution mode - Automatic dilution in case of capillary sample by analyser which minimizes manual dilution-related errors. Other Important Features: Direct access Clog removal key saves time for user by not needing to come back to main menu. Comprehensive built-in QC program for up to 10 lots with X -R, X B, X D CV value. Flexibility of dual calibration (Automatic 8 Manual calibration)allows user to calibrate the instrument according to his need to ensure the accuracy of measurements (results) Dual chamber for WBC Et RBC makes faster test results with more accurate & avoids cross-contamination Reagent depletion alarm for Lyse, Cleanser and Diluent, as optional function (Liquid Sensors) 10, 000 test results with histogram to meet all requirements Auto background measurement during start-up for ensuring trouble-free operation Internal thermal printer or facility to connect optional external printer RS232 interface & PC connectivity

Send Message
product image
Glucometer

STANDARD GlucoNavii GDH It can measure blood glucose through venous, capillary, arterial blood and as well as neonatal blood using GDH-FAD enzyme.Advantage Qualified accuracy that meets ISO15197:2013 No coding GDH-FAD enzyme (Capillary, Venous, Arterial and Neonatal blood) Specification Enzyme Glucose Dehydregenase-FAD biosensor Measurement Range 10 - 600mg/dL (0.6 - 33.3 mmol/L) Test Time 5 sec Sample Volume 0.5 µl Hematocrit 0 - 70% Unit mg/dL Memory Up to 500 tests Battery 3V battery (CR2032) Interpretation of results Cat. No. Product Component Note 01GC30 STANDARD™ GlucoNavii® GDH Blood Glucose Monitoring System Meter, Test Strip (10EA) / Lancet(10EA) / Lancing Device / Check Strip 01GS30 STANDARD™ GlucoNavii® GDH Blood Glucose Test Strip STANDARD™ GlucoNavii® GDH Test Strip (25EA x 2 bottle)

Send Message

Still searching for
measurement accuracy?