Jaipur
+918529833535

'maximum'

Items tagged with 'maximum'

product image
Clinical Chemistry

ADVIA 2400 Chemistry System The right balance of speed and efficiency The ADVIA® 2400 Clinical Chemistry System manages the most demanding workloads and meets high turnaround-time (TAT) goals. Its menu includes methods for testing drugs-of-abuse, therapeutic drugs (TDM) and new assays such as cystatin C and CardioPhase® hsCRP. The ADVIA 2400 Clinical Chemistry System offers: High throughput of up to 2400 tests/hour (1800 photometric and 600 ISE) to manage heavy workloads Rapid, consistent, 2-second cycle time for faster tube speed and test throughput User-defined automatic repeat, dilution, and reflex testing Large onboard reagent capacity and optional concentrated reagents help to minimize intervention demands Refrigerated onboard storage of controls and reagents for extended stability and increased productivity Automation-ready design: no additional hardware required Features & Benefits The ADVIA 2400 Clinical Chemistry System meets today’s high turnaround-time goals with a throughput of up to 2400 tests/hour. In addition to assays for general and specialty chemistries, its menu includes assays for specific protein measurement, drugs-of-abuse testing (DAT), and therapeutic drug monitoring (TDM). Interesting new assays such as cystatin C, HbA1c with automated sample pretreatment, and CardioPhase® hsCRP can now be included in your routine testing. The ADVIA 2400 Chemistry System pushes productivity levels while maintaining the reliability and stability that keep laboratories up and running. A rapid, 2-second probe cycle time maximizes tube speed and test throughput and combines with the system’s efficient automation-readiness to provide the turnaround time needed for high-volume laboratories Superior Speed and Productivity Throughput of up to 2400 tests/hour (1800 photometric and 600 ISE) to manage the heaviest workloads Rapid, consistent, 2-second cycle time Throughput of 200 tubes per hour, even when running three ISE tests and nine photometric tests per sample Automatic Sample Retain technology, auto-repeat, auto-dilution, and auto-reflex testing Automation-ready Point-in-space aspiration enables connectivity to a track. Redundant sample loading provides built-in backup and easy handling of non-routine samples. Direct sampling from track prevents tubes being detained at an analyzer and reduces aliquoting. Minimal Need for Operator Intervention Minimal-maintenance ISEs Large onboard reagent capacity and optional concentrated reagents for fewer interruptions No-maintenance, 37°C incubation oil bath Auto-calibration and auto-QC from refrigerated onboard calibrators and controls Microvolume technology with 32,000 tests onboard and up to 60 days' onboard stability for improved walkaway time. Concentrated reagents for increased maximum capacity. Remote diagnostics and Inter-Laboratory Quality Control (ILQC) options Exceptional Reliability Sample integrity check for icterus, hemolysis, and lipemia Sample probe with automatic clot/clog detection, liquid-level sensing, short-sample detection, and crash protection Advances in onboard reagent stability, calibration frequency, reduction in interferences, and expanded assay linearity

Send Message
product image
Clinical Chemistry

Designed to fulfill the clinical requirements of minimally invasive surgeries, Mindray's HD3 endoscope camera system comes with the advanced 3-chip CMOS sensor, premium optical lens, real-time optimization software and a FHD screen. Through delivering exceptional image quality and user experiences, the HD3 endoscope camera system enables surgeons to focus on their patients, helping facilitate more accurate diagnosis and treatments. HD3 Camera System 3-chip CMOS sensor FHD picture taking and video recording with USB port Advanced parfocal technology 2X optical zoom Focal length: 14mm-30mm Laparoscopes · High-resolution images and outstanding color rendition · Scratch-resistant sapphire lens · Fog reduction function · Autoclavable lens · Compatible with third-party optical fiber cables HS50 Insufflator · Maximum flow rate: 50L/min · Large 7-inch touchscreen · Gas heating function · Smoke evacuation · Automatic flow compensation · Auto-switchover between veress needle mode and trocar mode · Up to 5 insufflation modes, satisfy all insufflation needs HB200L LED Light Source · Equivalent to 300W Xenon light source · Autoclavable light cable · Auto-detection of light guide cable · Light intensity indicator · LED life expectancy: 40,000 hours PV27 FHD Monitor · 1920*1080 resolution · Picture-in-picture mode · Adjustable brightness · Flexible input: DVI,SDI,S-video,VGA

Send Message
product image
Hematology

The BC-3600 Hematology analyzer features closed tube sampling via a single push button. A built-in large 10.4 inch color touchscreen allows maximum visibility. Hemoglobin analysis is performed using cyanide-free reagent. The analyzer processes up to 60 samples per hour and stores up to 40,000 results with histograms. The barcode reader and optional LIS connectivity enable seamless sample data transmission. Nearly all scheduled maintenance procedures are automated by touch buttons. The intuitive software enhances workflow efficiency and provides operators with a pleasant user experience. Key Features CBC plus 3-part differential, 16 parameters + 3 histograms 60 samples per hour, 1 min per CBC Closed tube sampling, minimize operational biohazard Built In diluent dispenser for predilution mode All-in-one CBC result screen display; results at a glance Touch button maintenance procedures One maintenance reagent only – probe cleaner Storage capacity of 40,000 results with histograms Uploadable QC files; ensure accuracy and time efficiency Parameters WBC, Lymph#, Mid#, Gran#, Lymph%, Mid%, Gran%, RBC, HGB, HCT,MCV, MCH, MCHC, RDW,PLT, MPV and histograms for WBC, RBC, PLT Principles Electrical impedance method for cell counting and Cyanide - free for hemoglobin Sample Volume Prediluted 20µL Whole Blood 21µL Carryover WBC/RBC/HGB≤0.5% PLT≤1.0% Connectivity 4 USB ports (for external printer, software upgrade, barcode reader,keyboard and mouse), LAN port (1), RS232 (1) Printout Thermal recorder, 50mm width paper, various printout formats, external printer (optional) Product Specification Brand Mindray Differential Type 3-Part Model Name/Number BC 3600 Display Type Large color touch screen Resolution 800x600 Usage/Application Hospital Throughput 60 samples per hour Power Supply AC 100-240V,50/60 +-1Hz Weight 62 lbs Dimension 16 in(W) x 18 in(H) x 18 in(D) Humidity 30%-85% Temperature 15 ~30 Deg C Minimum Order Quantity 1

Send Message
product image
Instruments

Our organization is counted amongst the most distinguished providers of Diffraction Gratings. Diffraction Gratings we offer is widely used by the maximum number of user in the market. This product is developed with latest technology as per the set industry norms. To assure its flawlessness finish, offered products range is stringently tested on various quality parameters by our team of professional experts. We have carved a niche as the most prominent organization of this industry due to our commitment for the timely delivery at any part of the country. Features: Strong construction Dimensional accuracy Easy to use roduct Details: Usage Industrial Size Customized Material Glass Height Difference 0.2366 US Type Gratings

Send Message
product image
Distance Meter Digital

We are the Leading Supplier of Battery Hydrometer. With the assistance of our skilled professionals, we are offering a quality tested array of Battery Hydrometers to our valuable clients. Our Battery Hydrometers is available in varied specification as per the different demands of the clients. They give trouble free performance to the user as they are stringently tested on different quality parameters. We give complete finishing to our products before the final dispatch and satisfy maximum number of customers. This product range is offered in best specification to our clients. It is perfect in deigning and well tested on different quality parameters. Features: High strength Reasonable Prices Sturdy construction

Send Message
product image
Distance Meter Digital

We are the Leading Supplier of Vernier Caliper Digital. Our company has emerged as one of the top most positions in the industry for offering a wide range of Vernier Caliper Digital. This range of Vernier Caliper Digital is sturdily constructed to provide optimum efficiency to the user. These products are highly acclaimed by the clients for their preciseness, flawless performance and many other unique features. We have reasonably priced our entire product range without finding grounds for quality. We have given extra fine finishing to our final product range to attain maximum satisfaction of our clients. Features: High quality Less maintenance Feasible prices

Send Message
product image
Urinalysis Analyzer

The AUTION ELEVEN AE-4020 is intended for the qualitative and/or semi-quantitative measurement of several physiological markers in urine: Glucose, Protein, Bilirubin, pH, Blood, Urobilinogen, Ketones, Nitrite, Leukocytes, Creatinine, Albumin, Specific Gravity, P/C (Ratio of Protein to Creatinine) and A/C (Ratio of Albumin to Creatinine). These measurements are used for screening of kidney disease, liver disease, diabetes mellitus and urinary tract infection in general screening populations. Compact Design: 210(W) x 328(D) x 164(H) mm / Approx. 3.6 kg Processing speed: 514 samples per hour (maximum processing mode: 7 second interval) Auto-start function: Measurement starts automatically when a strip is set on the tray. Test strip can be placed either from the left or the right side. Maximum 11 parameters and color tone can be measured simultaneously by special test strips designed and made by ARKRAY. *Some products including test strips may not be available in all countries. Please check with your local Arkray representative or distributor about product availability in your area. Sample Urine Test Strip / Reagent pack AUTION Sticks / Uriflet S / AUTION SCREEN Measurement item GLU, KET, BIL, NIT, PRO, URO, pH, BLD, LEU, ALB, CRE, Specific Gravity, color tone Measurement range Test strip: As Rank table Color tone: As Color tone classification chart Measurement method Test strip method Dual-wavelength reflection photometric method (single wavelength for BLD) Measurement wavelength 4-wavelength LED (430, 565, 635, and 760 nm) Test strip reaction time 60 seconds Processing speed 514 samples per hour (maximum processing mode: 7-second interval) Display Custom LC display (icons are used) Built-in printer 32-digit thermal printer (58 mm width) External output Conforms to RS-232C standard (serial) Option: Ethernet Memory capacity 520 measurement results Temperature correction Auto-correction by the internal temperature sensor (between 10 to 30 °C) S. G. correction Auto-correction by pH values Chromaturia correction Auto-correction by the color tone correction section on test strips Operating environment Temperature: 10 to 30 °C; Humidity: 20 to 80% R.H. (non-condensing) Measurement environment Temperature: 10 to 30°C; Humidity: 30 to 60% R.H. (non-condensing) *Temperature correction function used DC power requirements(To instrument) 12 Vdc 3 A AC power requirements(To AC adapter) 100-240 Vac 50-60 HZ ,1200 mA Voltage fluctuation allowance is ±10% Power consumption Max. 45 VA Dimensions 210 (width) × 328 (depth) × 164 (height) mm Weight Approx. 3.6 kg

Send Message
product image
Urinalysis Analyzer

High Performance "Full Automated System" Color Touch Panel for good usability 7 inch WVGA color touchscreen with high operability displays measurement results, instrument conditions and operating instructions. "Sample delivery system" enables micro volume samples to be measured As the sample is drawn through the nozzle and delivered correctly and quantitatively to each pad of the strip, the micro volume samples (minimum 1mL) can be measured easily. No cross contaminations are found on the reagent portions despite high sample volume. Sample Urine Test items Glu, Pro, Bil, Uro, Ket, pH, Nit, Bld, Leu, S.G., Alb, Cre(Alb/Cre ratio, Pro/Cre ratio can be calculated), turbidity and color tone Wavelength 5 LED wavelengths (430, 500, 565, 635, 760nm) Measurement principle Test strip :Dual-wavelength reflectance method (One-wavelength for Bld) Specific gravity :Reflection refractometryColor hue :Light-transmission measurementTurbidity :Light-scattering measurement method Test strip AUTION Sticks (10EA & 10PA) , Uriflet S 11UA Reaction time Approximately 60 seconds Throughput 225 samples per hour Strip storage Maximum 400 strips (200 strips x 2 feeder boxes) Required sample volume Normal, STAT measurement: Minimum 2 mL Small volume measurement: Minimum 1 mL Sample consumption Normal, STAT measurement: Maximum 0.90 mL Small volume measurement: Maximum 0.45 mL Sample container Sample tubes (length: 95 - 110 mm, diameter: ø14.0 - 15.8 mm) Maximum sample load 100 samples (Circulation) Data memory Normal, STAT, small volume measurement: 2500 tests Control measurement: 200 tests Check measurement: 50 tests Trouble list: 100 tests Display Large color liquid crystal display (800 × 480 dots) Built-in printer 58-mm width printer paper (24 digits) External output 1 port (Replaceable with the optional Ethernet terminal) Communication method RS-232C compliant (Switchable between one-way and two-way) Measurement environment Temperature: 10 - 30°C; Humidity: 30 - 60% RH (No condensation) Power requirements 100 - 240 V AC (Maximum power line fluctuation of ±10%), 50/60 Hz Power consumption 150VA (Maximum) Dimensions 530 (W) × 530 (D) × 550 (H) mm (including the sampler) Weight Main body: Approximately 36 kg Sampler: Approximately 4 kg

Send Message

Still searching for
maximum?