Jaipur
+918529833535

'longer walk away time'

Items tagged with 'longer walk away time'

product image
Hematology

A Truly Automated Walkaway ESR Analyzer for Midsize labs (Meets CLSI and ICSH Guidelines) Product Features: Gold Standard Method -Measures all three phases of sedimentation as per Westergren method Dry Technology - No sample & reagent consumption, no waste generation Faster TAT - Throughput of 60 samples/hr Zero consumption cost by using EDTA tubes HCT correction feature eliminates manual correction in Anaemic samples Temperature correction at 18° ensures reliable results No additional cost of Calibration Analyzer Product Code Product Name Pack size ESL 30 122020 SMART CARD 2500 1x 2500 ESL 30 122021 SMART CARD 5000 1x 5000 ype of Sample : EDTA Sample Volume : > 1.5 ml Display : TFT high resolution 640 * 480 dots with LED Backlight Result Cycle Time : < 25 min Measuring Range : 0-140 mm/hr Touch screen : 5.7 inch resistive TFT high resolution Temperature Correction : At 18 Degree HCT Correction : HCT Correction facility available for Anaemic samples QC : Inbuilt Quality Control program with LJ Graphs Quality Control Level : 3 Level QC with LJ Graph QC Data Storage : 250 QC results Sample position : 30 sample position Throughput : 60 samples per hour Sample Consumption : No Type of Mode : Continuous mode STAT Facility : Available Calibration Requirement : No Mixer : Inbuilt Mixer Printer : Inbuilt Printer Barcode reader : Inbuilt Barcode reader Data Storage : 5000 results Operating Temperature : 20 - 30 Degree Celsius Storage Temperature : 15 - 35 Degree Celsius Relative Humidity : Max. 80% RH Power Adapter external : 240V DC , 90W Main supply : 100V-240V AC, 50/60 Hz (input for power adapter ) Dimension (mm) : 550(L) x 500 (W) x 395 (H) Weight : 20 kg (Approx )

Send Message
product image
Clinical Chemistry

The SAL 9000 Modular System delivers high throughput of chemistry and immunoassay testing by integrating Mindray BS-2000 Chemistry Analyzer and CL-6000i Chemiluminescence Immunoassay Analyzer, and new Sample Processing line SPL 2000. With patented automatic serum analysis design, SAL 9000 not only helps you optimize the management of lab space and manpower, it also offers highly reliable test results. Product Specification Automation Fully Automatic Brand Mindray Model Name/Number SAL 9000 Assays Clinical Chemistry Power Supply 230 V Reaction Cuvette Reusable Cuvette Storage 300000 Samples Features Seamless Integration Usage/Application Lab Wavelength 5000nm Number Of Reagent Positions 4 Weight 130kg Frequency 50 Hertz Power 45 Watt Product Description The SAL 9000 Modular System delivers high throughput of chemistry and immunoassay testing by integrating Mindray BS-2000 Chemistry Analyzer and CL-6000i Chemiluminescence Immunoassay Analyzer, and new Sample Processing line SPL 2000. With patented automatic serum analysis design, SAL 9000 not only helps you optimize the management of lab space and manpower, it also offers highly reliable test results. Features Maximize laboratory efficiency Integration: Optimize your lab’s customized arrangement with better automation system Efficiency: High-throughput chemistry and immunology modules for longer walk-away time Reliability: Ingenious and comprehensive analytic system provides reliable and accurate results Easy operation: Fully automated design,user-friendly operation interface and intelligent software function

Send Message
product image
Immunology Analyzer

Fully Automated Chemiluminescence Immunoassay Analyzer Introducing iFlash 1200, a chemiluminescence immunoassay analyzer that offers fully automated immunoassay analysis using Magnetic particle-based Direct Chemiluminescence technology. With a high throughput of up to 120 tests per hour and a first result available in just 13 minutes, iFlash 1200 is one of the fastest and most efficient immunoassay analyzers available on the market. The instrument features continuous STAT sample loading capacity with 16 sample positions, continuous reagents loading capacity with 15 reagent positions, and continuous loading of reaction vessels with a capacity of 500 cuvettes. Additionally, iFlash 1200 uses Acridinium Ester Labeled Direct Chemiluminescence for highly accurate and reliable results, and comes with ready-to-use reagents in convenient 2 x 50 tests pack size for simplified testing. Overall, iFlash 1200 is an innovative and versatile immunoassay analyzer that is perfect for laboratories that require high throughput and rapid turnaround times. iFlash 1200 chemiluminescence immunoassay analyzer Key Features: 1.Continuous loading of reagents with convenient pack size of 2 x 50 tests 2.Continous loading of 500 reaction cuvettes for longer walkaway time 3. 4 step magnetic separation for achieving high precision and quality results 4.Non contact vortex mixer-Highly Efficient technology to prevent carryover & cross contamination Additional information General Information Throughput : upto 120 tests/hour Time to First Results :13 minutes Detection Principle Magnetic particle Based Direct Chemiluminescence Chemiluminescence Label :Acridinium Ester Sample System Sample Position :16 sample position Types of Sample tube :Microcup & blood collecting tubes Sample Volume :5~150μL Reagent System Reagent Position :15 reagent positions with onboard refrigeration Reagent Carousel Temp :2-8 °C Reagent Detection :Reagent Level Tracking Reagent Pack : 2 x 50 tests Reagent Carousel Incubation Capacity :48 reaction vessels Incubation Temperature :37°C+-0.3°C Mixing System :Non-Contact Vortex Mixer Operating Conditions Power Supply :100~240V, 50/60HZ Power Consumption :600VA Temperature :10~30°C Weight :120 Kg Reagents iFlash 1200 reagents iFlash 1200 reagents Pack size 2 x 50 Tests 28 days On board reagent stability 28 days Calibration stability Built in Calibrators for all Parameters

Send Message
product image
Clinical Chemistry

ADVIA 2400 Chemistry System The right balance of speed and efficiency The ADVIA® 2400 Clinical Chemistry System manages the most demanding workloads and meets high turnaround-time (TAT) goals. Its menu includes methods for testing drugs-of-abuse, therapeutic drugs (TDM) and new assays such as cystatin C and CardioPhase® hsCRP. The ADVIA 2400 Clinical Chemistry System offers: High throughput of up to 2400 tests/hour (1800 photometric and 600 ISE) to manage heavy workloads Rapid, consistent, 2-second cycle time for faster tube speed and test throughput User-defined automatic repeat, dilution, and reflex testing Large onboard reagent capacity and optional concentrated reagents help to minimize intervention demands Refrigerated onboard storage of controls and reagents for extended stability and increased productivity Automation-ready design: no additional hardware required Features & Benefits The ADVIA 2400 Clinical Chemistry System meets today’s high turnaround-time goals with a throughput of up to 2400 tests/hour. In addition to assays for general and specialty chemistries, its menu includes assays for specific protein measurement, drugs-of-abuse testing (DAT), and therapeutic drug monitoring (TDM). Interesting new assays such as cystatin C, HbA1c with automated sample pretreatment, and CardioPhase® hsCRP can now be included in your routine testing. The ADVIA 2400 Chemistry System pushes productivity levels while maintaining the reliability and stability that keep laboratories up and running. A rapid, 2-second probe cycle time maximizes tube speed and test throughput and combines with the system’s efficient automation-readiness to provide the turnaround time needed for high-volume laboratories Superior Speed and Productivity Throughput of up to 2400 tests/hour (1800 photometric and 600 ISE) to manage the heaviest workloads Rapid, consistent, 2-second cycle time Throughput of 200 tubes per hour, even when running three ISE tests and nine photometric tests per sample Automatic Sample Retain technology, auto-repeat, auto-dilution, and auto-reflex testing Automation-ready Point-in-space aspiration enables connectivity to a track. Redundant sample loading provides built-in backup and easy handling of non-routine samples. Direct sampling from track prevents tubes being detained at an analyzer and reduces aliquoting. Minimal Need for Operator Intervention Minimal-maintenance ISEs Large onboard reagent capacity and optional concentrated reagents for fewer interruptions No-maintenance, 37°C incubation oil bath Auto-calibration and auto-QC from refrigerated onboard calibrators and controls Microvolume technology with 32,000 tests onboard and up to 60 days' onboard stability for improved walkaway time. Concentrated reagents for increased maximum capacity. Remote diagnostics and Inter-Laboratory Quality Control (ILQC) options Exceptional Reliability Sample integrity check for icterus, hemolysis, and lipemia Sample probe with automatic clot/clog detection, liquid-level sensing, short-sample detection, and crash protection Advances in onboard reagent stability, calibration frequency, reduction in interferences, and expanded assay linearity

Send Message
product image
Clinical Chemistry

ADVIA Chemistry XPT System An advanced, automated clinical chemistry analyzer for high-volume laboratories The ADVIA® Chemistry XPT System provides timely, reliable results with continuous operation to meet the chemistry workloads of the most demanding laboratories. Delivers high throughput of up to 2400 tests per hour. Manages comprehensive testing with a menu of more than 115 assays. Improves workflow using automation and system technologies such as micro-volume and aliquot retention. Features & Benefits The ADVIA Chemistry XPT System*** is engineered for continuous operation and timely, accurate results—supporting you to reach your full potential today and be prepared for tomorrow. With an advanced user interface that is easy to use and VeriSmart Technology to support accuracy of testing, the ADVIA Chemistry XPT System predictably and consistently delivers timely, reliable results to meet expanding workloads. Simplified, Continuous Operation Simplify operation and training with the intuitive, icon-driven user interface. Extend walkaway times with concentrated reagents that provide high test capacity onboard. Quickly load most system fluids on the fly. Automate calibration, QC, startup, and shutdown. Consistent, Predictable Turnaround Time and Accuracy Offer a comprehensive chemistry menu of over 115 assays, including general and specialty chemistry, DAT, TDM, and specific proteins. Push productivity with a throughput of up to 2400 tests per hour (1800 photometric, plus 600 ISE). Control testing: STAT and specialty samples can always be front-loaded while an automation track is running. Designed for Automation Adapt and grow with direct connectivity to Siemens Healthineers and . Simplify your laboratory operations with connectivity to IT solutions including , , and . Increase productivity and efficiency with direct-from-track sampling and onboard aliquoting that allows samples to be immediately released to the next workstation. Do More with Less Reduce blood-draw requirements with micro-volume technology that uses a single 30 μL sample for up to 15 tests. Eliminate sample callback with automated, pre-programmable dilution, reflex, and rerun testing that uses an onboard aliquot. Improve workflow and accuracy with VeriSmart echnologies that perform hardware and software checks at all stages of sample processing.

Send Message
product image
Hematology

The BC-5390 is a 5-part Auto Hematology Analyzer that delivers high productivity, better accuracy and improved patient care, without sacrificing your budget. The analyzer utilizes the power of three mainstream technologies: laser scatter, flow cytometry, and chemical dye, to provide more accurate clinical information. The BC-5390 has been approved by FDA. Features Robust capacity and functionality Its throughput of 60 samples per hour saves your time, and the capacity of 40 autoloading tubes can extend your walk-away time. More reliable test result.The new reagent, with better anti-aging capacity, helps better differentiate Eosinophils from Neutrophils in the DIFF scattergram, even on samples with high density of Eosinophils. The analyzer is empowered by the fluid sensing technology to detect clot, bubble and insufficient sample, ensuring accurate sample aspiration. Flexible sample aspiration With different holder adapters, the analyzer supports three analysis modes - venous whole blood mode, pre-diluted mode and capillary whole blood mode. Product Specification Model Name/Number BC-5390 Operation Mode Fully Automatic Usage/Application Hospital Brand Mindray Capacity 40 autoloading tubes Throughput 60 samples per hour

Send Message
product image
Hematology

n large laboratories, rows of instruments are seen working tirelessly like miniature factories – only they produce not commodities but medical test results. Mindray CAL 8000 new-generation cellular automation line is one of them, but unlike a typical workhorse, it is intelligent. It is a highly automated workstation for smarter, faster, and more accurate cellular analysis. It can perform competently in the face of these challenges. The workstation can hold up to four units of BC-6800 automated hematology analyzer, which utilizes the advanced SF Cube technology and 3-D scatter grams to help doctors better differentiate blood cell populations and reveal abnormal cells undetectable by conventional techniques. With 125 CBC tests per hour per unit, BC-6800 brings the process rate of the workstation to 20–30 percent higher than other similar models, effectively alleviating laboratory's stress during the peak processing hours. On CAL 8000, the hematology analyzer, slide maker and stainer, CRP analyzer, and HbA1c analyzer are all integrated into one seamless production line through automated track modules and trolley. Simply by loading a single tube of blood sample onto the automation system, one can get all the test results. This innovative walk-away automation functionality has made possible the CBC+CRP+HbA1c testing all in one streamlined workstation for the first time in the industry. It offers a smart solution, or rather, a smart expert – the labX pert 2.0. It is a software that can automatically sort out the suspected samples for manual validation. The pathologist then decides if rerun or microscopic review is warranted based on their clinical experience. It avoids wasting slides and reduces extra work. Moreover, the onboard automated re-exam functionality also helps enhance work efficiency. The CMU software The touch screen is the “brain” of CAL 8000. It optimizes the distribution of workload between each analyzer unit and decides which sample requires a blood smear. It displays the status of each analyzer or SC-120 installed on CAL 8000 as well as the volume of balance reagent. This intuitive software can tell the users all necessary information of CAL 8000 at any given time. Consequently, the users spend less time operating CAL 8000 and can arrange their working schedule better. Multi “R” tests The CAL 8000 can automatically distribute the samples with “Repeat”, “Rerun” and “Reflex” criteria which are pre-defined by users.The re-exam criteria on CAL 8000 can be defined by many conditions, such as time, patient’s age, gender, department, etc. This helps minimize the number of blood smears. Special tube racks The special tube racks utilize different barcodes to differentiate specific testing purposes, such as “QC”, “Slide making & staining only” and “RET test only”. The special tube racks can carry the tubes to perform these specific functions in the simplest way.

Send Message
product image
Rapid Test

Xpress Gluco strips make the testing experience better. These Glucometer strips are designed for self-testing, for both professional and home use. Accurex Blood Glucose test strips provide accurate results in just 5 seconds. Buy Xpress Gluco Test Strips (Pack of 10 Strips) Online from Accurex Point of Care (POC) Diagnostics. The Sugar machine strips do not require any coding & are compatible with Accurex glucometers only. Sample size: 0.5uL, System Measurement Range: 20-800 mg/dL, Hemocrit Range: 25-55 %, Works only with Accurex Glucometer. TEST PRINCIPLE: ELECTROANALYTICALAMPEROMETRY When blood is added to the Xpress Gluco test strip, the chemicals within the strip react with the blood to create a tiny electrical current. Your meter will read that current and display you the blood glucose level. • Accurex test strips make the testing experience better. • Longer shelf life and clearly marked expiry date. • Designed for self testing for both professional and home use. • Accurate results in just 5 seconds. • Works only with Accurex Glucometer. • Uses only 0.5uL blood sample size • Alternate site testing possible • No-coding required • Compatible with Accurex glucometers only CHEMICAL COMPOSITION: Each Xpress Gluco test strip contains: • Enzyme Glucose Oxidase (Aspergillus Sp.) ≥ 1IU • Other ingredients (Mediator, Surfactant, Stabilizing agents etc.) ≥ 200μg • Xpress Gluco Test Strips are used to measure glucose in Capillary whole blood outside of the body (in vitro diagnostic use). • Use Xpress Gluco Test Strips only with the Xpress Gluco Blood Glucose Test System. • Xpress Gluco Test Strips are plasma calibrated to allow easy comparison of results with laboratory methods. • This system is not intended for use in the diagnosis of diabetes mellitus. • This system is not recommended for Neonates Blood samples. Result interpretation: • Xpress Gluco Meter delivers plasma equivalent results and are displayed in mg/dL. • The measurement range of the meter is 20-800mg/dL. • Your blood glucose values will vary due to such things as diet, time of day and what you are doing. Your healthcare professional will help you to understand these variations. You should set your own range of expected blood glucose values, testing times, and discuss your blood glucose results with your healthcare professional. • When blood is added to the Xpress Gluco test strip, the chemicals within the strip react with the blood to create a tiny electrical current. • Your meter will read that current and display you the blood glucose level. • Use fresh whole blood sample only. • Sample size: 0.5uL • Analysis time: 5 seconds • System Measurement Range: 20-800 mg/dL • Hemocrit Range: 25-55 % Safety Information Important saftey handling: • Wash hands thoroughly, with soap and water before and after testing • Never use fingerstick devices for more than one person. Use auto disabling, single use fingerstick devices for assisted monitoring of blood glucose. Storage & Handling: • Store the strips in their original vial in a cool, dry place between: 0°-50° C (32° and 122° F). Keep away from direct sunlight and heat. • Do not refrigerate or freeze. • When you take a strip from the vial, close the cap immediately. Use the strip immediately. • Check the expiry date on the vial. If the expiry date has passed, do not use the strips. Important health-related information: • Severe dehydration and excessive water loss may cause false low results. If you believe you are suffering from severe dehydration, consult your physician or doctor immediately. • Test results below 70 mg/dL. mean low blood glucose (hypoglycemia). • Test results greater than 180 mg/dL mean high blood glucose (hyperglycemia). • If you get results below 70 mg/dL or above 180 mg/dL and do not have symptoms of hypoglycemia or hyperglycemia, repeat the test. If you have symptoms or continue to get results that fall below 70 mg/dL or above 180 mg/dL, follow the treatment/advice of your healthcare professional. • If you are experiencing symptoms that are not consistent with your blood glucose test and you have followed all instructions described in the Xpress Gluco owner’s booklet, consult your healthcare professional Other Info UNEXPECTED RESULTS: Very high or very low blood glucose readings can indicate a serious medical condition. Repeat the test if you see an unusual reading. If these results are still unusual, or do not match your symptoms, contact your health care professional for advice. Hi or Low readings may indicate hyper or hypoglycemia and should be treated immediately. ABOUT ALTERNATIVE SITE TESTING: Test can be done on alternative site (other than fingertip). However, there are limitations. Please consult your physician before perfoming AST.

Send Message

Still searching for
longer walk away time?