Jaipur
+918529833535

'liquid surface'

Items tagged with 'liquid surface'

product image
Laboratory Usage

We are the Leading Supplier of Abbe Refractometer Rajdhani. In the Abbe'' refractometer the liquid sample is sandwiched into a thin layer between an illuminating prism and a refracting prism. The refracting prism is made of a glass with a high refractive index (e.g., 1.75) and the refractometer is designed to be used with samples having a refractive index smaller than that of the refracting prism. A light source is projected through the illuminating prism, the bottom surface of which is ground (i.e., roughened like a ground-glass joint), so each point on this surface can be thought of as generating light rays traveling in all directions. A detector placed on the back side of the refracting prism would show a light and a dark region. Over a century after Abbe''s work, the usefulness and precision of refractometers has improved, although their principle of operation has changed very little. They are also possibly the easiest device to use for measuring the refractive index of solid samples, such as glass, plastics, and polymer films. Some modern Abbe refractometers use a digital display for measurement, eliminating the need for discerning between small graduations. However, the user still has to adjust the view to get a final reading. The first truly digital laboratory refractometers began appearing in the late 1970s and early 1980s, and no longer depended on the user''s eye to determine the reading. They still required the use of circulating water baths to control instrument and fluid temperature. They did, however, have the ability to electronically compensate for the temperature differences of many fluids where there is a known concentration-to-refractive-index conversion. Most digital laboratory refractometers, while much more accurate and versatile than their analog Abbe counterparts, are incapable of readings on solid samples. In the late 1990s, Abbe refractometers became available with the capability of measurements at wavelengths other than the standard 589 nanometers. These instruments use special filters to reach the desired wavelength, and can extend measurements well into the near infrared (though a special viewer is required to see the infrared rays). Multi-wavelength Abbe refractometers can be used to easily determine a sample''s Abbe number.

Send Message
product image
BP Apparatus

Product Details: Material Plastic Automation Type Semi-Automatic Color White Usage/Application Industrial Range 0/20 A 0/20 20/40 40/60 60/80 80/100 Type Hydrometers We are engaged in manufacturing and supplying of Sikes Hydrometers of superior quality range. Hydrometers is a device to measure relative density of liquids such as Grease, oil etc. Components used in a hydrometer are glass frame, cylindrical stem and bulb floating in the mercury fluid.To test the density of a liquid, we use a long glass jar.The jar is filled with liquid and hydrometer is floated inside the fluid.The liquid surface touches the stem of hydrometer at specific point, which indicates specific gravity of that fluid. Features: Alcohol meter (V / V, Volume By Volume) Zeal U.K. at 15.6ºC Range: 0-20, 20-40, 40-60, 60-80, & 80-100 JAWA (Brix) Hydrometers with work Certificate Germany Range: No.1 - 2 to 13 No.2 - 13 to 21 No.3 - 19 to 27 Heavy Liquid Hydrometers, Germany Sp.Gr.1000/2000 & BE 0/70 Light Liquid Hydrometers, Germany Sp.Gr. 700/1000 & BE 10/70 Heavy Liquid Hydrometers, 305 mm Long, Range - 1.000 / 2.000 & 0/70 Baume Light Liquid Hydrometers, 230 mm Long, Range : 700 / 1.000 Baume Hydrometers, Germany at 20ºC Range: 0/10, 10/20, 20/30, 0/20, 0/30, 0/40, 0/50, 30/40 & 40/50 Baume Hydrometers, Digital, Atago, Japan Model PAL-84S, Range : 0.0 - 210 Twaddle Hydrometers German at 60ºF, No. 1, 2, 3, 4, 5, & 6 Twaddle Hydrometer Zeal England at 84ºF, No. 1, 2, 3 & 6 Twaddle Hydrometer Zeal England at 84ºF, No. 4 & 5 Brix Hydrometer w/o Thermometer Germany at 20ºC Range: 0/10, 10/20 & 20/30 Brix Hydrometer w/o Thermometer Germany at 27.5ºC Range: 0/10, 10/20, 20/30, 30/40, 0/30, 30/60 & 60/90 Brix Hydrometer with Thermometer Germany at 27.5ºC & 20ºC Range: 0/10, 10/20, 20/30, 0/30, 30/60 & 60/90 Brix Hydrometer with Thermometer Germany GDR, German at 27.5ºC & 20ºC Range: 0/10, 10/20 & 20/30 Brix Hydrometer with Thermometer German with NPL Certificate Brix Hydrometer, Sugar Percent Temp. 27.5ºC Made in West Germany Specific Gravity Hydrometers, Germany at 20ºC 600/700, 700/800, 800/900 & 900/1000 & 800/10001000/1100, 1100/1200, 1200/1300, 1300/14001400/1500, 1500/1600, 1600/1700, 1700/18001000/1200, 1200/1400, 1400/1600, 1600/1800, 1800/2000 800/1000 GDR German Make Sikes Table Book Indian Soil Hydrometer, Zeal England, ASTM 152 H Range: 5 to 60 gm / ltr, Temp: 68ºF Yes! I am interested

Send Message
product image
Distance Meter Digital

Product Details: Warranty 6 Months Material Glass Temperature 15.6oC equal to 60oF Standard ASTM We are the Leading supplying of Hydrometer Device of superior quality range. Hydrometers is a device to measure relative density of liquids such as Grease, oil etc. Components used in a hydrometer are glass frame, cylindrical stem and bulb floating in the mercury fluid. To test the density of a liquid, we use a long glass jar. The jar is filled with liquid and hydrometer is floated inside the fluid. The liquid surface touches the stem of hydrometer at specific point, which indicates specific gravity of that fluid. Specifications: Sikes Hydrometer at 51ºF, Zeal England: Range: 0/20 A 0/20 20/40 40/60 60/80 80/100 Alcohol meter (V / V, Volume By Volume) Zeal U.K. at 15.6ºC Range: 0-20, 20-40, 40-60, 60-80, & 80-100 JAWA (Brix) Hydrometers with work Certificate Germany Range: No.1 - 2 to 13 No.2 - 13 to 21 No.3 - 19 to 27 Heavy Liquid Hydrometers, Germany Sp.Gr.1000/2000 & BE 0/70 Light Liquid Hydrometers, Germany Sp.Gr. 700/1000 & BE 10/70 Heavy Liquid Hydrometers, 305 mm Long, Range - 1.000 / 2.000 & 0/70 Baume Light Liquid Hydrometers, 230 mm Long, Range : 700 / 1.000 Baume Hydrometers, Germany at 20ºC Range: 0/10, 10/20, 20/30, 0/20, 0/30, 0/40, 0/50, 30/40 & 40/50 Baume Hydrometers, Digital, Atago, Japan Model PAL-84S, Range : 0.0 - 210 Twaddle Hydrometers German at 60ºF, No. 1, 2, 3, 4, 5, & 6 Twaddle Hydrometer Zeal England at 84ºF, No. 1, 2, 3 & 6 Twaddle Hydrometer Zeal England at 84ºF, No. 4 & 5 Brix Hydrometer w/o Thermometer Germany at 20ºC Range: 0/10, 10/20 & 20/30 Brix Hydrometer w/o Thermometer Germany at 27.5ºC Range: 0/10, 10/20, 20/30, 30/40, 0/30, 30/60 & 60/90 Brix Hydrometer with Thermometer Germany at 27.5ºC & 20ºC Range: 0/10, 10/20, 20/30, 0/30, 30/60 & 60/90 Brix Hydrometer with Thermometer Germany GDR, German at 27.5ºC & 20ºC Range: 0/10, 10/20 & 20/30 Brix Hydrometer with Thermometer German with NPL Certificate Brix Hydrometer, Sugar Percent Temp. 27.5ºC Made in West Germany Specific Gravity Hydrometers, Germany at 20ºC 600/700, 700/800, 800/900 & 900/1000 & 800/10001000/1100, 1100/1200, 1200/1300, 1300/14001400/1500, 1500/1600, 1600/1700, 1700/18001000/1200, 1200/1400, 1400/1600, 1600/1800, 1800/2000 800/1000 GDR German Make Sikes Table Book Indian Soil Hydrometer, Zeal England, ASTM 152 H Range: 5 to 60 gm / ltr, Temp: 68ºF

Send Message
product image
Rapid Test

Buy AccuTest HIV – 1/2 Ab Rapid Card Test (50 Tests) Online from Accurex. This Rapid HIV test is a visual, solid phase immunochromatographic assay for qualitative in-vitro diagnostic detection of antibodies against HIV-1 and HIV-2 in human serum/plasma. This HIV test may be used as an aid in diagnosis of HIV infection. In the HIV blood test – A reactive result should be confirmed by supplemental testing as part of a validated HIV testing algorithm. INTENDED USE: AccuTest HIV – 1/2 Ab test is a visual, solid phase immunochromatographic assay for qualitative in-vitro diagnostic detection of antibodies against HIV-1 and HIV-2 in human serum/plasma. The product may be used as an aid in diagnosis of HIV infection. A reactive result should be confirmed by supplemental testing as part of a validated HIV testing algorithm. INTRODUCTION: The Human Immunodeficiency Virus (HIV) is a retrovirus that infects cells of the immune system, destroying or impairing their function. The most advanced stage of HIV infection is Acquired Immunodeficiency Syndrome (AIDS). The general method of detecting infection with HIV is to observe the presence of antibodies to the virus by an EIA method followed by confirmation with any confirmation method. AccuTest HIV – 1/2 Ab is a simple, visual qualitative test that detects antibodies in human serum/plasma. The test is based on immunochromatography and can give a result within 15 minutes. PRINCIPLE: AccuTest HIV – 1/2 Ab employs chromatographic lateral flow device in a cassette format. Colloidal gold conjugated recombinant antigens (Au-Ag) corresponding to HIV-1 (gp120 + gp41) and HIV-2 (gp-36) are dry-immobilized at the end of nitrocellulose membrane strip. HIV-1 & HIV-2 antigens are bound at the Test Zone (1 & 2) respectively. Goat Anti-Mouse IgG antibodies are bound at the Control Zone(C). When the sample is added, it migrates by capillary diffusion rehydrating the gold conjugate. If there are HIV-1 or HIV-2 antibodies in sample, they will bind with the gold conjugated antigens forming particles. These particles will continue to migrate along the strip until the Test Zone (1 or 2) where they are captured by the HIV-1 or HIV-2 antigens generating a visible purple line. If the specimen contains antibodies to HIV-1, the specimen will bind to the 1 test line and produce line. If specimen contains antibodies to HIV2, the specimen will bind to the 2 test line. If there are no HIV-1 or HIV-2 antibodies in sample, no purple line is formed in the Test Zone. The gold conjugate will continue to migrate alone until it is captured in the Control Zone (C) by the Goat Anti Mouse IgG antibodies aggregating in a purple line, which indicates that the migration of liquid has been successful. The control line must be present for the test to be valid. PRECAUTIONS: 1. For best results, adhere to instructions provided. 2. All specimens should be handled as potentially infectious. 3. The test device is sensitive to humidity as well as heat. 4. Do not use beyond expiration date. 5. Do not use test kit if pouch is damaged or seal is broken. 6. Use test device immediately after removing from the pouch. 7. The components (test device and assay diluents) in this kit have been quality control tested as a standard batch unit. Do not mix components from different lot numbers. 8. The AccuTest HIV – 1/2 Ab Test devices should be stored at 4 to 30 °C. Do not expose the kit to temperature over 30 °C. 9. Specimen with extremely high concentrations of red blood cells, fibrin should be recentrifuged before use. 10. AccuTest HIV – 1/2 Ab Test Device (Serum/Plasma) is for in vitro diagnostic use only. 11. AccuTest HIV – 1/2 Ab Test Device (Serum/Plasma) will only indicate the presence of antibodies to HIV-1/2 in the specimen and should not be used as the sole criteria for the diagnosis of HIV-1, HIV-2, and/or HIV-1 subtype O infection. 12. For confirmation of reactive test results, specimens should undergo further testing using different assays, such as rapid diagnostic tests, EIA and/or Western blotting in accordance with a validated HIV testing algorithm. 13. As with all diagnostic tests, all results must be interpreted together with other clinical information available to the physician. 14. Results should not be used to determine the serotype of HIV infections TEST PROCEDURE: 1. Allow the test device, buffer and specimen to reach room temperature (15-30 °C) prior to testing. 2. Remove the test device from the foil pouch and use the test device as soon as possible (within one hour). 3. Place the device on a flat, dry surface. Label with specimen ID. 4. Holding the sample dropper vertically above the test disk, slowly transfer 1 drop (10µl) of sample in to the sample well, then add 2 drops of assay diluent (about 75 µl) and start the timer. 5. As the test begins to work, you will see purple color moving across the result Window in the center of the Test Disk. 6. Wait for the colored lines to appear. Interpret test results at 15 to 20 minutes. Do not interpret test result after 20 minutes. STORAGE AND STABILITY Store as packaged in the sealed pouch at 4-30 °C (storage in refrigerator is permitted). Do not store in the freezer. Protect the test kit from humidly. The test device is stable until the expiration date printed on the test kit and/or sealed test device pouch. Do not use beyond the expiration date. The test device must remain in the sealed pouch until use.

Send Message
product image
Rapid Test

Intended Use Hepacard is visual, rapid, sensitive and accurate one step immunoassay for the qualitative detection of Hepatitis B surface antigen (HBsAg) in Human serum or plasma.The assay is intended to be used as an aid in the recognition and diagnosis of acute infections and chronic infectious carriers of the Hepatitis B Virus(HBV). Salient Features Detects all the 11 subtype of HBsAg. Antigen Sensitivity- 0.5 ng/ml. No sample preparation required. See through Device for easy result interpretation. Shelf life-30 months at 2-30°C. WHO Evaluated with 100% Sensitivity.

Send Message
product image
Clinical Chemistry

ADVIA 2400 Chemistry System The right balance of speed and efficiency The ADVIA® 2400 Clinical Chemistry System manages the most demanding workloads and meets high turnaround-time (TAT) goals. Its menu includes methods for testing drugs-of-abuse, therapeutic drugs (TDM) and new assays such as cystatin C and CardioPhase® hsCRP. The ADVIA 2400 Clinical Chemistry System offers: High throughput of up to 2400 tests/hour (1800 photometric and 600 ISE) to manage heavy workloads Rapid, consistent, 2-second cycle time for faster tube speed and test throughput User-defined automatic repeat, dilution, and reflex testing Large onboard reagent capacity and optional concentrated reagents help to minimize intervention demands Refrigerated onboard storage of controls and reagents for extended stability and increased productivity Automation-ready design: no additional hardware required Features & Benefits The ADVIA 2400 Clinical Chemistry System meets today’s high turnaround-time goals with a throughput of up to 2400 tests/hour. In addition to assays for general and specialty chemistries, its menu includes assays for specific protein measurement, drugs-of-abuse testing (DAT), and therapeutic drug monitoring (TDM). Interesting new assays such as cystatin C, HbA1c with automated sample pretreatment, and CardioPhase® hsCRP can now be included in your routine testing. The ADVIA 2400 Chemistry System pushes productivity levels while maintaining the reliability and stability that keep laboratories up and running. A rapid, 2-second probe cycle time maximizes tube speed and test throughput and combines with the system’s efficient automation-readiness to provide the turnaround time needed for high-volume laboratories Superior Speed and Productivity Throughput of up to 2400 tests/hour (1800 photometric and 600 ISE) to manage the heaviest workloads Rapid, consistent, 2-second cycle time Throughput of 200 tubes per hour, even when running three ISE tests and nine photometric tests per sample Automatic Sample Retain technology, auto-repeat, auto-dilution, and auto-reflex testing Automation-ready Point-in-space aspiration enables connectivity to a track. Redundant sample loading provides built-in backup and easy handling of non-routine samples. Direct sampling from track prevents tubes being detained at an analyzer and reduces aliquoting. Minimal Need for Operator Intervention Minimal-maintenance ISEs Large onboard reagent capacity and optional concentrated reagents for fewer interruptions No-maintenance, 37°C incubation oil bath Auto-calibration and auto-QC from refrigerated onboard calibrators and controls Microvolume technology with 32,000 tests onboard and up to 60 days' onboard stability for improved walkaway time. Concentrated reagents for increased maximum capacity. Remote diagnostics and Inter-Laboratory Quality Control (ILQC) options Exceptional Reliability Sample integrity check for icterus, hemolysis, and lipemia Sample probe with automatic clot/clog detection, liquid-level sensing, short-sample detection, and crash protection Advances in onboard reagent stability, calibration frequency, reduction in interferences, and expanded assay linearity

Send Message
product image
Clinical Chemistry

HyPort B30 With the higher requirement of the healthcare, and continuing focus on the efficient clinical workflow, the advanced medical technology is always demanded from the patients and hospital. While some hospitals have limited space and budget, they search for a simple pendant solution to enhance the work efficiency and better care for the patient. Mindray HyPort B30 provides a simple, compact and cost-effective design for Anesthesia Pendant and Surgical Pendant in OR and ICU Pendant to meet this requirement. Less space needed with slimmer column design Easy to handle for nurse after reducing pendant weight Hygienic surface with anti-bacteria coating Built-in rails for accessories and no exposed screws

Send Message

Still searching for
liquid surface?