Jaipur
+918529833535

'limitation'

Items tagged with 'limitation'

product image
Hemoglobin Meter

Buy Accurex H12 Hemoglobin Test Strips Online – for better result & accuracy. These Hemoglobin strips are used with URIT Hemoglobin Meter, for the quantitative measurement of total hemoglobin in capillary and venous whole blood. These hb strips are to be used by health care professionals only, not to be used for patient self-testing. Accurex HB Test Strips come with a pack size of 50 strips. The Accrues test strip utilizes Dry Chemistry Colorimeter Method (Azido methemoglobin Method). Meter’s optical detectors automatically measure the change in the membrane Buy Accurex H12 Hemoglobin Test Strips Online – for better result & accuracy. These Hemoglobin strips are used with URIT Hemoglobin Meter, for the quantitative measurement of total hemoglobin in capillary and venous whole blood. These hb strips are to be used by health care professionals only, not to be used for patient self-testing. Accurex HB Test Strips come with a pack size of 50 strips. The Accrues test strip utilizes Dry Chemistry Colorimeter Method (Azido methemoglobin Method). Meter’s optical detectors automatically measure the change in the membrane Operation Principle: The test strip utilizes Dry Chemistry Colorimeter Method (Azido methaemoglobin Method). When a drop of whole blood is applied to the test spot on the strip, blood immediately disperses within the membrane, contacting the reagent. The meter’s optical detectors avtomatically measure the change in membrane reflectance. The intensity of reflectance is inversely proportional to the hemoglobin concentration. Blood Sample Collection: Fresh or EDTA-anticoagulated capillary or venous whole blood may be used. If an EDTA – treated sample is refrigeratted to come to the room temperature before testing. EDTA treated blood samples should be mixed using end to and inversions at least 8 times prior to use, and should be tested within 24nours Do not use the haemolytic sample anticogulants other than EDTA are not recommended for use. Caution: 1. Same as all diagnostic tests, hemoglobin test results should be evaluated with the specific patient’s condition. Any results demonstrating the inconsistency with the patient’s clinical status should be repeated or supplemented with additional test data. 2. Do not touch the test membrane by hand 3. H12 Hemoglobin Test Strips are one-off product, do not use again Storage & Preparation: 1.H12 Hemoglobin Test Strips should be stored at O C-30 C dry and dark places, 2 C – B C is the best storage environment emperatures recommended. Keep away from direct sunlight and heat, must not be frozen, If the container was stored in refrigerated before first use, please don’t take it back into the refrigerator again after first use. 2. H12 Hemoglobin Test Strips are ready to use. No additional preparation is required 3. Enclosed desiccants with lest strip. Remove only those strips needed for testing. The remaining lest strips should be resealed in their onginal container and used up in 3 months after first use. Do not use lest strips and throw away alter expiry date. 4. Use the strip immediately once taking it out af the container, otherwise the result will be incorrect 5. Do not fold or cut the test strip. 6. Used lest strips cannot be used again, dispose them as normal medical waste Direction for Use Operating Instructions: 1. URIT Hemoglobin Meter, H12 Hemoglobin Test Strip, Lancing Device, and disposable blood taking needle. 2. Test steps: 1) Turn the meter on and input the Code Card. Check the Code Card displaying on the meter to ensure it to match the Code Card printed on the lest strip container. Otherwise, the result is incorrect. 2) Massage the patient’s finger from the knuckle up to the tip to stimulate blood flow. Clean the sample area with alcohol and wipe it dry with a sterile gauze pad. 3) Insert the lest strip into the strip holder with the notched end in first and the hole facing up. 4) Puncture the skin on the lower side of fingertip with blood collection needle, and remove 13-15 TIL of whole biood with capillary or other micro blood collection apparatus. While waiting for the instrument to display the blood drop symbol, quickly add the drops to the test hole on the reagent sheet. Please make sure that the blood drop volume can completely cover the test hole but not overflow the test hole. 5) The meter starts the test automatically after the blood sample disperses Once the lest is in process do nol disturb or move the meter or test strip, or press any key. The test result will display within 12 seconds. Qualtiy Control Procedure: Use only H12 Hemoglobin Test Strip with QC substance to perform QC. The range of QC substance is the numerical range indicated on the label of the QCsubstance or test strips. When to do a QCtest: 1. Whenever you suspect that the meter or test strips are not working properly. 2. If your hemoglobin test results are not consistent with how you feel. Other Info Limitations of test Method: H12 Hemoglobin Test Strip is only suitable for testing fresh or whole capillary blood or whole venous blood containing EDTA anticoagulants. Do not use serum, plasma or arterial blood

Send Message
product image
Rapid Test

Buy AccuTest Typhoid IgG/IgM Rapid Card Test (5 Tests) Online from Accurex. The Typhoid IgG/IgM Rapid Test is used for detection & differentiation of anti-Salmonella typhi (S. typhi) IgG and IgM in human whole blood / serum / plasma. This Typhoid test is used as a screening test and as an aid in the diagnosis of infection with S. typhi. Salmonella typhi bacteria causes typhoid Typhoid fever, typhoid symptoms symptoms are likely to develop gradually – appearing one to three weeks after exposure to the disease. There are various typhoid treatment & typhoid vaccine which can be opted after the detetction of Typhoid. Typhoid fever is caused by S. typhi, a Gram-negative bacterium. Worldwide an estimated 17 million cases and 600,000 associated deaths occur annually. Patients who are infected with HIV are at significantly increased risk of clinical infection with S. typhi. Evidence of H. pylori infection also presents an increased risk of acquiring typhoid fever. 1-5% of patients become chronic carrier harboring S. typhi in the gall bladder. The clinical diagnosis of typhoid fever depends on the isolation of S. typhi from blood, bone marrow or a specific anatomic lesion. In the facilities that can not afford to perform this complicated and time-consuming procedure, Filix-Widal test is used to facilitate the diagnosis. However, many limitations lead to difficulties in the interpretation of the Widal test. In contrast, the Typhoid IgG/IgM Rapid Test is a simple and rapid laboratory test. The test simultaneously detects and differentiates the IgG and the IgM antibodies to S. typhi specific antigen thus to aid in the determination of current or previous exposure to the S. typhi. PRINCIPLE The Typhoid IgG/IgM Rapid Test is a lateral flow immunochromatographic assay. The test cassette consists of: 1) a pink-purple colored conjugate pad containing recombinant S. typhi H antigen and O antigen conjugated with colloid gold (Typhoid conjugates) and rabbit IgG-gold conjugates, 2) a nitrocellulose membrane strip containing two test region (Test line M and G) and a control region (control line). The test line ‘M’ is pre-coated with monoclonal anti-human IgM for the detection of IgM anti-S. typhi, test line ‘G’ is pre-coated with monoclonal anti-human IgG for the detection of IgG anti-S. typhi , and the C band is pre-coated with goat anti rabbit IgG. When an adequate volume of test specimen is dispensed into the sample well of the cassette, the test specimen migrates by capillary action across the test cassette. Anti-S. typhi IgM if present in the patient specimen will bind to the Typhoid conjugates. The immunocomplex is then captured on the membrane by the pre-coated anti-human IgM antibody at test region ‘M’, forming a pink-purple line at ‘M’ region, indicating a S. typhi IgM positive test result. Anti-S. typhi IgG if present in the patient specimen will bind to the Typhoid conjugates. The immunocomplex is then captured by the pre-coated reagents on the membrane, forming a pink-purple line at test region ‘G’, indicating a S. typhi IgG positive test result. Absence of any pink-purple line at test region (M and G) suggests a negative result. The test contains an internal control (control line) which should exhibit a pink-purple line of the immunocomplex of goat anti rabbit IgG/rabbit IgG-gold conjugate regardless of the color development on any of the test region. Otherwise, the test result is invalid and the specimen must be retested with another device. PRECAUTION 1. This package insert must be read completely before performing the test. Failure to follow the insert gives inaccurate test results. 2. Do not open the sealed pouch, unless ready to conduct the assay. 3. Do not use expired devices. 4. Bring all reagents to room temperature (15°C-30°C) before use. 5. Do not use the components in any other type of test kit as a substitute for the components in this kit. 6. Do not use hemolized blood specimen for testing. Wear protective clothing and disposable gloves while handling the kit reagents and clinical specimens. Wash hands thoroughly after performing the test. 7. Users of this test should follow the US CDC Universal Precautions for prevention of transmission of HIV, HBV and other blood-borne pathogens. 8. Do not smoke, drink, or eat in areas where specimens or kit reagents are being handled. 9. Dispose of all specimens and materials used to perform the test as biohazardous waste. 10. Handle the Negative and Positive Control in the same manner as patient specimens. 11. The testing results should be read within 15 minutes after a specimen is applied to the sample well or sample pad of the device. Read result after 15 minutes may give erroneous results. 12. Do not perform the test in a room with strong air flow, ie. an electric fan or strong air-conditioning. Other Info STORAGE AND STABILITY Typhoid IgG/IgM test card should be stored at 4-40°C. The card may be stored at room temperature but not exceeding 40°C in the original sealed pouch. The shelf life or expiry of the card is printed on Pouch as well as carton label. The test kit should be kept away from direct sunlight, moisture and heat.

Send Message
product image
Rapid Test

Buy Dengue NS1 Antigen test (Pack of 5 test) from Accurex. This NS1 Antigen Rapid test contains: A Test device in aluminum pouch with a desiccant, Disposable dropper & Pack Insert. Dengue NS1 antigen test utilizes the human serum / plasma followed by solid-phase immuno-chromatographic technology for the qualitative detection of dengue virus NS1 antigen. Dengue NS1 Antigen kit is for professional use and only for the initial screening test & reactive samples should be confirmed by a supplemental assay such as nucleic acid test & other immunological assays. EXPLANATION OF THE TEST Dengue NS1 antigen test utilizes the human serum / plasma followed by solid-phase immuno-chromatographic technology for the qualitative detection of dengue virus NS1 antigen. The membrane strip of the kit contains pre-coated anti-dengue NS1 monoclonal antibody on the test band region (T), and goat anti-mouse IgG is pre-coated on the control band region (C). During testing, if the sample containing dengue NS1 Ag, the complex of the antibody-dengueNS1 Ag-gold conjugate moves laterally on the membrane by capillary action. In this case, the colored band will appear on the membrane in test line (T). Control line (C) should always appear if the test procedure is performed properly Safety Information 1. For in-vitro diagnostic use only. Do not re-use the test device. 2. The instruction must be followed exactly to get accurate results. 3. Anyone performing an assay with this product must be trained in its use and must be experienced in laboratory procedures. 4. Do not eat or smoke while handling specimens. 5. Wear protective gloves while handling specimens. Wash hands thoroughly afterwards. 6. Avoid splashing or aerosol formation. 7. Clean up spills thoroughly using an appropriate disinfectant. 8. Decontaminate and dispose of all specimens, reaction waste, in a biohazard container. 9. Do not mix and interchange different specimen. 10. The presence of humidity may decrease the stability of the tests. Thus, carry out the test immediately after removing the device from the foil pouch. 11. Do not use it beyond the expiration date. Direction for Use 1. Place all specimens, test device and solution. Allow them to room temperature prior to testing (15~30 min.) 2. Please perform the test immediately after removing the device from the foil pouch. 3. With a disposable dropper, load 2-3 drops (50 to 75µl) of specimen into the sample well (S) in the test device. 4. Interpret the test results between 15~20 minutes. Do not read the results after 20 minutes. Other Info 1) Dengue NS1 Antigen test should be stored between 4~30 ºC 2) Expiration date of this kit is 24 months after its manufacture date. LIMITATIONS OF THE TEST Dengue NS1 antigen test is designed for primary screening test of dengue virus NS1 antigen. Although this can provide fast and easy way to get a result, the testing do not completely exclude the possibility of false positive or negative result caused by various factor. So, refer to the result of the kit, please make a final decision with clinical manifestation, other test results and doctor’s view collectively.

Send Message
product image
Rapid Test

Buy Dengue NS1 Antigen test (Pack of 10 test) from Accurex. This NS1 Antigen Rapid test contains: A Test device in aluminum pouch with a desiccant, Disposable dropper & Pack Insert. Dengue NS1 antigen test utilizes the human serum / plasma followed by solid-phase immuno-chromatographic technology for the qualitative detection of dengue virus NS1 antigen. The membrane strip of the kit contains pre coated anti-dengue NS1 monoclonal antibody on the test band region (T), & goat anti-mouse IgG is pre-coated on the control band region (C). EXPLANATION OF THE TEST Dengue NS1 antigen test utilizes the human serum / plasma followed by solid-phase immuno-chromatographic technology for the qualitative detection of dengue virus NS1 antigen. The membrane strip of the kit contains pre-coated anti-dengue NS1 monoclonal antibody on the test band region (T), and goat anti-mouse IgG is pre-coated on the control band region (C). During testing, if the sample containing dengue NS1 Ag, the complex of the antibody-dengueNS1 Ag-gold conjugate moves laterally on the membrane by capillary action. In this case, the colored band will appear on the membrane in test line (T). Control line (C) should always appear if the test procedure is performed properly PRECAUTIONS 1. For in-vitro diagnostic use only. Do not re-use the test device. 2. The instruction must be followed exactly to get accurate results. 3. Anyone performing an assay with this product must be trained in its use and must be experienced in laboratory procedures. 4. Do not eat or smoke while handling specimens. 5. Wear protective gloves while handling specimens. Wash hands thoroughly afterwards. 6. Avoid splashing or aerosol formation. 7. Clean up spills thoroughly using an appropriate disinfectant. 8. Decontaminate and dispose of all specimens, reaction waste, in a biohazard container. 9. Do not mix and interchange different specimen. 10. The presence of humidity may decrease the stability of the tests. Thus, carry out the test immediately after removing the device from the foil pouch. 11. Do not use it beyond the expiration date. SPECIMEN COLLECTION AND STORAGE Direction for Use 1. Place all specimens, test device and solution. Allow them to room temperature prior to testing (15~30 min.) 2. Please perform the test immediately after removing the device from the foil pouch. 3. With a disposable dropper, load 2-3 drops (50 to 75µl) of specimen into the sample well (S) in the test device. 4. Interpret the test results between 15~20 minutes. Do not read the results after 20 minutes. Other Info STORAGE & EXPIRATION 1) Dengue NS1 Antigen test should be stored between 4~30 ºC 2) Expiration date of this kit is 24 months after its manufacture date. LIMITATIONS OF THE TEST Dengue NS1 antigen test is designed for primary screening test of dengue virus NS1 antigen. Although this can provide fast and easy way to get a result, the testing do not completely exclude the possibility of false positive or negative result caused by various factor. So, refer to the result of the kit, please make a final decision with clinical manifestation, other test results and doctor’s view collectively.

Send Message
product image
Glycohemoglobin Analysis

Xpress Gluco strips make the testing experience better. These Glucometer strips are designed for self-testing, for both professional and home use. Accurex Blood Glucose test strips provide accurate results in just 5 seconds. Buy Xpress Gluco Test Strips (Pack of 100 Strips) Online from Accurex Point of Care (POC) Diagnostics. The Sugar machine strips do not require any coding & are compatible with Accurex glucometers only. Sample size: 0.5uL, System Measurement Range: 20-800 mg/dL, Hemocrit Range: 25-55 %, Works only with Accurex Glucometer. TEST PRINCIPLE: ELECTROANALYTICALAMPEROMETRY When blood is added to the Xpress Gluco test strip, the chemicals within the strip react with the blood to create a tiny electrical current. Your meter will read that current and display you the blood glucose level. • Accurex test strips make the testing experience better. • Longer shelf life and clearly marked expiry date. • Designed for self testing for both professional and home use. • Accurate results in just 5 seconds. • Works only with Accurex Glucometer. • Uses only 0.5uL blood sample size • Alternate site testing possible • No-coding required • Compatible with Accurex glucometers only CHEMICAL COMPOSITION: Each Xpress Gluco test strip contains: • Enzyme Glucose Oxidase (Aspergillus Sp.) ≥ 1IU • Other ingredients (Mediator, Surfactant, Stabilizing agents etc.) ≥ 200μg • Xpress Gluco Test Strips are used to measure glucose in Capillary whole blood outside of the body (in vitro diagnostic use). • Use Xpress Gluco Test Strips only with the Xpress Gluco Blood Glucose Test System. • Xpress Gluco Test Strips are plasma calibrated to allow easy comparison of results with laboratory methods. • This system is not intended for use in the diagnosis of diabetes mellitus. • This system is not recommended for Neonates Blood samples. Result interpretation: • Xpress Gluco Meter delivers plasma equivalent results and are displayed in mg/dL. • The measurement range of the meter is 20-800mg/dL. • Your blood glucose values will vary due to such things as diet, time of day and what you are doing. Your healthcare professional will help you to understand these variations. You should set your own range of expected blood glucose values, testing times, and discuss your blood glucose results with your healthcare professional. • When blood is added to the Xpress Gluco test strip, the chemicals within the strip react with the blood to create a tiny electrical current. • Your meter will read that current and display you the blood glucose level. • Use fresh whole blood sample only. • Sample size: 0.5uL • Analysis time: 5 seconds • System Measurement Range: 20-800 mg/dL • Hemocrit Range: 25-55 % UNEXPECTED RESULTS: Very high or very low blood glucose readings can indicate a serious medical condition. Repeat the test if you see an unusual reading. If these results are still unusual, or do not match your symptoms, contact your health care professional for advice. Hi or Low readings may indicate hyper or hypoglycemia and should be treated immediately. ABOUT ALTERNATIVE SITE TESTING: Test can be done on alternative site (other than fingertip). However, there are limitations. Please consult your physician before perfoming AST.

Send Message
product image
Rapid Test

Xpress Gluco strips make the testing experience better. These Glucometer strips are designed for self-testing, for both professional and home use. Accurex Blood Glucose test strips provide accurate results in just 5 seconds. Buy Xpress Gluco Test Strips (Pack of 10 Strips) Online from Accurex Point of Care (POC) Diagnostics. The Sugar machine strips do not require any coding & are compatible with Accurex glucometers only. Sample size: 0.5uL, System Measurement Range: 20-800 mg/dL, Hemocrit Range: 25-55 %, Works only with Accurex Glucometer. TEST PRINCIPLE: ELECTROANALYTICALAMPEROMETRY When blood is added to the Xpress Gluco test strip, the chemicals within the strip react with the blood to create a tiny electrical current. Your meter will read that current and display you the blood glucose level. • Accurex test strips make the testing experience better. • Longer shelf life and clearly marked expiry date. • Designed for self testing for both professional and home use. • Accurate results in just 5 seconds. • Works only with Accurex Glucometer. • Uses only 0.5uL blood sample size • Alternate site testing possible • No-coding required • Compatible with Accurex glucometers only CHEMICAL COMPOSITION: Each Xpress Gluco test strip contains: • Enzyme Glucose Oxidase (Aspergillus Sp.) ≥ 1IU • Other ingredients (Mediator, Surfactant, Stabilizing agents etc.) ≥ 200μg • Xpress Gluco Test Strips are used to measure glucose in Capillary whole blood outside of the body (in vitro diagnostic use). • Use Xpress Gluco Test Strips only with the Xpress Gluco Blood Glucose Test System. • Xpress Gluco Test Strips are plasma calibrated to allow easy comparison of results with laboratory methods. • This system is not intended for use in the diagnosis of diabetes mellitus. • This system is not recommended for Neonates Blood samples. Result interpretation: • Xpress Gluco Meter delivers plasma equivalent results and are displayed in mg/dL. • The measurement range of the meter is 20-800mg/dL. • Your blood glucose values will vary due to such things as diet, time of day and what you are doing. Your healthcare professional will help you to understand these variations. You should set your own range of expected blood glucose values, testing times, and discuss your blood glucose results with your healthcare professional. • When blood is added to the Xpress Gluco test strip, the chemicals within the strip react with the blood to create a tiny electrical current. • Your meter will read that current and display you the blood glucose level. • Use fresh whole blood sample only. • Sample size: 0.5uL • Analysis time: 5 seconds • System Measurement Range: 20-800 mg/dL • Hemocrit Range: 25-55 % Safety Information Important saftey handling: • Wash hands thoroughly, with soap and water before and after testing • Never use fingerstick devices for more than one person. Use auto disabling, single use fingerstick devices for assisted monitoring of blood glucose. Storage & Handling: • Store the strips in their original vial in a cool, dry place between: 0°-50° C (32° and 122° F). Keep away from direct sunlight and heat. • Do not refrigerate or freeze. • When you take a strip from the vial, close the cap immediately. Use the strip immediately. • Check the expiry date on the vial. If the expiry date has passed, do not use the strips. Important health-related information: • Severe dehydration and excessive water loss may cause false low results. If you believe you are suffering from severe dehydration, consult your physician or doctor immediately. • Test results below 70 mg/dL. mean low blood glucose (hypoglycemia). • Test results greater than 180 mg/dL mean high blood glucose (hyperglycemia). • If you get results below 70 mg/dL or above 180 mg/dL and do not have symptoms of hypoglycemia or hyperglycemia, repeat the test. If you have symptoms or continue to get results that fall below 70 mg/dL or above 180 mg/dL, follow the treatment/advice of your healthcare professional. • If you are experiencing symptoms that are not consistent with your blood glucose test and you have followed all instructions described in the Xpress Gluco owner’s booklet, consult your healthcare professional Other Info UNEXPECTED RESULTS: Very high or very low blood glucose readings can indicate a serious medical condition. Repeat the test if you see an unusual reading. If these results are still unusual, or do not match your symptoms, contact your health care professional for advice. Hi or Low readings may indicate hyper or hypoglycemia and should be treated immediately. ABOUT ALTERNATIVE SITE TESTING: Test can be done on alternative site (other than fingertip). However, there are limitations. Please consult your physician before perfoming AST.

Send Message
product image
Glycohemoglobin Analysis

Xpress A1c strips are used for a testing of quantitative determination of glycated hemoglobin(HBA1c) in human whole blood. It is used to monitor metabolic control in diabetic patients. it helps in diagnosis of the diabetes or pre-diabetes in adults. Buy Xpress A1c strips online (Pack of 25 Strips) – the best a1c test strips from Point of Care (POC) Range of Accurex HbA1c strips works as both a pipette and measuring element. A Blood drop of 8uL is needed for measurement. This blood is drawn into the cavity by capillary action. It helps users to understand their diabetes control status or to monitor their risk of developing diabetes. The Xpress A1c strips works as both a pipette and measuring element. A Blood drop of 8uL is needed for measurement. This blood is drawn into the cavity by capillary action. The Xpress A1c strips then needs to be inserted into Xpress A1c meter for hemoglobin measurement, The Xpress A1c meter measures the absorbance of whole blood at Hb isosbestic point. Xpress A1c meter uses two wavelengths of light to calculate Hemoglobin level, user level calibration is not required. How to use: Step 1: Wash hands using soap and warm water. Rinse and dry thoroughly. Step 2: Turn on the meter by pressing-releasing the power button. Step 3: Remove an Xpress A1c strip from the vial. Step 4: Prick a finger to obtain a blood sample. Step 5: Touch and hold the drop of blood to the pointed edge of the Xpress A1c strip. The blood is drawn into the Xpress A1c strip by capillary action Step 6: Once the blood fills the Xpress A1c strip chamber. Insert the Xpress A1c strip into the Xpress A1c meter. Step 7: Your Hemoglobin result will appear on the display window. Step 8: Remove the Xpress A1c strip from the meter and discard it. The meter will automatically turn off or long-press the power button to turn off. The Xpress A1c strips are used to quantitatively measure the concentration of HbA1C in whole blood, suitable for the self-monitoring of HbA1C for diabetes patients. It helps users to understand their diabetes control status or to monitor their risk of developing diabetes. is used to quantitatively measure the concentration of HbA1C in whole blood, suitable for the self-monitoring of HbA1C for diabetes patients. It helps users to understand their diabetes control status or to monitor their risk of developing diabetes.Features: Sample Type: Whole Blood/EDTA Blood/Capillary Blood Measuring Range: 0 to 25 g/dl Temperature: 0°C-50°C Storage Temperature: Room Temperature Expiry: Long Expiry(min 02 yrs) Pack Size: 25 Test/Vial LIMITATION AND WARNING: 1. This product is used for In Vitro Diagnostics only, not for in vivo use. 2. This product should not be used past the expiration date. 3. If there is evidence of microbial contamination or browning, discard the vial. 4. This product is not intended to be used as an HbA1c standard. 5. Preservatives contained in the control, rinse with water if splash into the mouth or eyes, and seek medical help as soon as possible. 6. Potential biological risk. Direction for Use This product should be run in accordance with instructions accompanying BioHermes Glycohemoglobin Test Kit and Glycohemoglobin Analyzer. (1) Dissolution: Open the cap of the vial, and then add 2 drops of Buffer A. Close the cap, and slightly shake the vial until the powder dissolved completely. And please shake it well before using it. (2) Testing in accordance with instructions accompanying BioHermes Glycohemoglobin Test Kit and Glycohemoglobin Analyzer. Please refer to the B Storage: 1. This product will be stable for 24 months when stored tightly capped at 2-8℃. 2. After dissolved, the product can be stable for 8 hours at 10-30℃, or 5 days at 2-8℃. Do not freeze it. COMPOSITION: This product is prepared from human blood and contains normal hemoglobin, preservatives and stabilizers. The control is provided in lyophilized powder form for increased stability. The kit contains two levels of control, level 1 is with yellow cap, and level 2 is with green cap.

Send Message
product image
Glycohemoglobin Analysis

Accurex Xpress A1c Glycohemoglobin Analysis System Kit . The Kit contains HbA1c Meter, 1 Sampler, 1 box of 25 test strips, Buffer A, Buffer B. Glycohemoglobin Analyzer It is used for testing glycohemoglobin concentration as an aid to monitor the risk of developing diabetes & control the status of diabetes. Buy Xpress A1c Meter Kit Online from Accurex Point of Care (POC ) Range – The HbA1c analyzer is specifically designed to be used with the corresponding test strip. HbA1c analyzer Hemoglobin A1C is a common blood test that measures blood glucose levels over the past two to three months. •Glycohemoglobin Analyzer •Handheld HbA1c Meter •Battery Operated •No Pipetting, No Lysing •Lab like Accuracy •Battery Operated •Truly Portable •Voice prompt for •User Guidance • Accurate result with cv <3% •Lab like accuracy with 95% •No interference of HB Variant •No pipetting •No lysing •Reagent: Suitable to store at room temperature (upto 30º C) The Power of HbA1c in your Hand esting Principle: Boronate Affinity Chromatography Testing Parameter: Glycohemoglobin (HbA1c) Measuring Range: 4.0% – 14.0% Precision: CV <3% (HbA1c: 4.0% – 6.5%) Blood Sample: Finger Prick or Venous Blood ( EDTA Anticoagulant) Blood Volume: About 3ul Testing Time: About 5 minutes Data Unit: Set in Advance the Data Unit • NGSP%; IFCC mmol/mol; eAG* mmol/l Voice Prompt: Voice Prompt to Guide the user Data Storage: 1000 Testing Data Data Port: Mini USB data interface can be connected with HIS/LIS; System Thermal Printer Power Required: AAA Battery x 4 Analyzer Dimension: 61.6 x 122.9 x 24.5 mm Screen Size: 47 x 32 mm” Safety Information LIMITATION AND WARNING: 1. This product is used for In Vitro Diagnostics only, not for in vivo use. 2. This product should not be used past the expiration date. 3. If there is evidence of microbial contamination or browning, discard the vial. 4. This product is not intended to be used as an HbA1c standard. 5. Preservatives contained in the control, rinse with water if splash into the mouth or eyes, and seek medical help as soon as possible. 6. Potential biological risk. Direction for Use This product should be run in accordance with instructions accompanying BioHermes Glycohemoglobin Test Kit and Glycohemoglobin Analyzer. (1) Dissolution: Open the cap of the vial, and then add 2 drops of Buffer A. Close the cap, and slightly shake the vial until the powder dissolved completely. And please shake it well before using it. (2) Testing in accordance with instructions accompanying BioHermes Glycohemoglobin Test Kit and Glycohemoglobin Analyzer. Please refer to the B Other Info Storage: 1. This product will be stable for 24 months when stored tightly capped at 2-8℃. 2. After dissolved, the product can be stable for 8 hours at 10-30℃, or 5 days at 2-8℃. Do not freeze it. COMPOSITION: This product is prepared from human blood and contains normal hemoglobin, preservatives and stabilizers. The control is provided in lyophilized powder form for increased stability. The kit contains two levels of control, level 1 is with yellow cap, and level 2 is with green cap.

Send Message

Still searching for
limitation?