Jaipur
+918529833535

'lab space'

Items tagged with 'lab space'

product image
Clinical Chemistry

ADVIA 2400 Chemistry System The right balance of speed and efficiency The ADVIA® 2400 Clinical Chemistry System manages the most demanding workloads and meets high turnaround-time (TAT) goals. Its menu includes methods for testing drugs-of-abuse, therapeutic drugs (TDM) and new assays such as cystatin C and CardioPhase® hsCRP. The ADVIA 2400 Clinical Chemistry System offers: High throughput of up to 2400 tests/hour (1800 photometric and 600 ISE) to manage heavy workloads Rapid, consistent, 2-second cycle time for faster tube speed and test throughput User-defined automatic repeat, dilution, and reflex testing Large onboard reagent capacity and optional concentrated reagents help to minimize intervention demands Refrigerated onboard storage of controls and reagents for extended stability and increased productivity Automation-ready design: no additional hardware required Features & Benefits The ADVIA 2400 Clinical Chemistry System meets today’s high turnaround-time goals with a throughput of up to 2400 tests/hour. In addition to assays for general and specialty chemistries, its menu includes assays for specific protein measurement, drugs-of-abuse testing (DAT), and therapeutic drug monitoring (TDM). Interesting new assays such as cystatin C, HbA1c with automated sample pretreatment, and CardioPhase® hsCRP can now be included in your routine testing. The ADVIA 2400 Chemistry System pushes productivity levels while maintaining the reliability and stability that keep laboratories up and running. A rapid, 2-second probe cycle time maximizes tube speed and test throughput and combines with the system’s efficient automation-readiness to provide the turnaround time needed for high-volume laboratories Superior Speed and Productivity Throughput of up to 2400 tests/hour (1800 photometric and 600 ISE) to manage the heaviest workloads Rapid, consistent, 2-second cycle time Throughput of 200 tubes per hour, even when running three ISE tests and nine photometric tests per sample Automatic Sample Retain technology, auto-repeat, auto-dilution, and auto-reflex testing Automation-ready Point-in-space aspiration enables connectivity to a track. Redundant sample loading provides built-in backup and easy handling of non-routine samples. Direct sampling from track prevents tubes being detained at an analyzer and reduces aliquoting. Minimal Need for Operator Intervention Minimal-maintenance ISEs Large onboard reagent capacity and optional concentrated reagents for fewer interruptions No-maintenance, 37°C incubation oil bath Auto-calibration and auto-QC from refrigerated onboard calibrators and controls Microvolume technology with 32,000 tests onboard and up to 60 days' onboard stability for improved walkaway time. Concentrated reagents for increased maximum capacity. Remote diagnostics and Inter-Laboratory Quality Control (ILQC) options Exceptional Reliability Sample integrity check for icterus, hemolysis, and lipemia Sample probe with automatic clot/clog detection, liquid-level sensing, short-sample detection, and crash protection Advances in onboard reagent stability, calibration frequency, reduction in interferences, and expanded assay linearity

Send Message
product image
Clinical Chemistry

The ADVIA® 1800 Clinical Chemistry System pushes the limit of productivity. Its extensive menu allows integration of testing for clinical chemistry, drugs-of-abuse, therapeutic drug monitoring (TDM) and specific proteins such as cystatin C and CardioPhase® hsCRP. The ADVIA 1800 Clinical Chemistry System offers: Throughput of up to 1,800 tests per hour to keep pace with workload peaks 200 basic metabolic panels per hour to meet turnaround-time demands Large onboard reagent capacity and optional concentrated reagents to reduce interruptions Optimal standardization of reagents and systems for efficient consumable usage Refrigerated onboard storage of controls and reagents for extended stability and increased productivity Automation-ready design: no additional hardware required Features & Benefits The ADVIA 1800® Clinical Chemistry System pushes the limit of productivity in the core lab and meets the turnaround-time (TAT) goals of today’s laboratories. Its extensive menu allows integration of general clinical chemistry testing with testing for drugs-of-abuse, TDM, special chemistry, and specific proteins such as cystatin C and CardioPhase® hsCRP. Automation-ready design Point-in-space aspiration enables connectivity to a track, VersaCell® System. Redundant sample loading provides built-in backup and easy handling of non-routine samples. Direct sampling from track prevents tubes being detained at an analyzer and reduces aliquoting. Peak productivity Throughput of up to 1,800 tests per hour provides the speed to keep pace with workload peaks. Throughput of 200 basic metabolic panels per hour helps to meet turnaround-time demands. Automatic Sample Retain technology lets you perform reruns and dilutions without the need to retrieve primary tubes. Consolidate chemistry testing on one system with a comprehensive menu, consistent cycle times, speed, and open application capability. Total system reliability Minimal-maintenance ISEs Robust hardware and simplified software design, with automatic calibration validation and tracking Advances in reagent onboard stability, calibration frequency, interference reduction and assay linearity expansion Direct water connection Remote diagnostics and Inter-Laboratory Quality Control (ILQC) options Easy efficiency Large onboard reagent capacity and optional concentrated reagents reduce interruptions. High-resolution touchscreen delivers push-button operation. Reagent pause capability and onboard Sample Pause button make loading easy. Minimal maintenance requirements, including no-maintenance oil bath, reduce hands-on time. Sample integrity checking, include serum indices reporting, short-sample flagging, and clot detection, reducing the need for manual intervention.

Send Message
product image
Clinical Chemistry

With the built-in oxygen concentration monitoring system and effective cable management system, the HyPort R80 is capable of creating a reliable and streamlined ICU environment to ensure patient safety. Recovery The lighting system of the HyPort R80 aims to create a comfortable, near-natural light ICU environment to enhance patient recovery. 1234 1 Circadian Light Simulating 24-hour natural daylight change to reflect circadian rhythm. 2 Examination Light Up to 10,000 lux, 5-level adjustable illuminance meets various needs of head and abdominal examination. 3 Reading Light Effectively avoid invalid glare to meet the reading needs of rehabilitating patients. 4 Navigation Light Providing enough lighting with less glare for medical staff’s easy observation and intervention. Efficiency The HyPort R80 is a highly integrated bedside device management system that helps caregivers organize medical devices to meet various clinical needs. It makes efficient use of beside space with a series of easy-to-use designs, enabling a more efficient workflow for medical staff. Folding-shelf design Suitable for both portable ventilators and integrated ventilators. p46-s3-2-web Bag-valve-mask management Making sure bag valve mask is easy to access and ready for emergency situations anytime when needed. p46-s3-3-web Partition management The pump separation layout allows medical staff to easily identify infusion pumps and feeding pumps. p46-s3-4-web Smooth movement The advanced braking technology ensures stability of the column when moving. NextPrevious Variety The HyPort R80 has been designed to meet the demands of different ICU layouts to create a safer, more efficient and comfortable ICU environment with patient-centric design.ICU double room solution A Product Specification Usage/Application Hospital Brand Mindray Model Name/Number HyPort B80 Features 60 Degreepanel interface for easier plug-in of gas and electricity Color White Panel Interface 60 Degree Product Description Gas and electricity separated 60°panel interface for easier plug-in of gas and electricity Flexible movement of sliding and rotating of the distributions Additional accessories for better management of details Considerate lighting option Safer and more effective workflow Gas and electricity separated 60°panel for easier plug-in of gas and electricity Better management Customized drawer solutions Wire basket - dfferent size options available Cable management solutions

Send Message
product image
Hematology

At Mindray we pride ourselves on our dedication and experience in developing better solutions for small labs. Our new line of 3-part hematology analyzers is the culmination of that effort. Compact yet powerful, full featured yet affordable, the BC-20s is what a 3-part analyzer should be. Features CBC+3-DIFF, 19 parameters+3 histograms Throughput:40 samples per hour Intuitive operation system with 8.4 inch TFT touch screen Open vial sampling 200,000 results storage with histograms Original QC, calibrators and reagents Product Specification Instrument Name Haematology Analyzer Model Name/Number BC20s Usage/Application Laboratory Brand Mindray Automation Fully Automatic Operation Mode Fully Automatic

Send Message
product image
Hematology

The advanced BC-6800Plus not only provides more reliable routine CBC plus 5-part DIFF results, but also has a higher throughput of up to 200 samples per hour. Based on the new SF Cube technology platform, the BC-6800Plus could provide more reliable blood cell results and abnormal cells flagging results with anticipated warning messages, exceeding clinicians’ expectations and setting a new standard for blood analysis. SF Cube Technology With the newly designed opticals and reagent systems, the SF Cube technology can help doctors to better differentiate the clusters of cells, which is the key to revealing more abnormal cells. NRBC result in every CBC In WNB scattergram, BC-6800Plus provides NRBC, Basophils and WBC-N* results. It means that the actual number of NRBCs can be measured in routine CBC, if they are present in the sample. Basophils are counted in this counting channel with NRBC results. Basophil and NRBC results are generated on BC-6800Plus without extra reagent or cost. NLR parameter in each CBC+DIFF Neutrophil-to-lymphocyte ratio (NLR) is calculated by dividing neutrophil count by lymphocyte count, usually from peripheral blood sample. In laboratory medicine, NLR is used as a marker of subclinical inflammation. According to clinical studies, NLR can be used as a prognostic factor of severe illness in COVID-19 patients. More accurate RET and PLT-O result By utilizing the new fluorescent dye, the reticulocytes and platelets are more specific stained with stronger fluorescent signal, that brings more reliable reticulocyte and platelet results. Automatic Rerun & Reflex Should the sample results trigger the criteria, the sample rack can automatically step back for a “rerun” or “reflex” check. 200 test/hour BC-6800Plus can load up to 100 samples at a time and offers a throughput of up to 200 tests per hour.

Send Message
product image
Hematology

Based on Mindray’s continuous innovation in hematology field, BC-5130 is especially tailored to assist diagnostic labs who need full CBC + 5-part results, with relatively low daily sample volume, restricted lab space and tight budget. As the lightest and most compact 5-part hematology analyzer so far from Mindray, BC-5130 is a highly user-friendly and innovative analyzer that offers cost efficient CBC and 5-part white cell differential results. It is targeted to fulfill and exceed the demands of our global customers by providing more accurate, more efficient and more innovative solutions for labs. Improved DC impedance technology is used to count and size the RBC and PLT. The smaller counting aperture (50 μm in diameter) provides better performance on samples with low PLT. Efficient Only three routine reagents are required. These have 2 years shelf life and also less consumed by BC-5130. Original QC and calibrator are also provided to ensure the hematology analyzer’s traceability and testing quality. WBC 5-Part differentiation,25 reportable parameters & 23 research parameters,3 histograms Whole blood Mode, Capillary whole blood mode & Prediluted Mode Tri-angle Laser Scatter + Chemical dye + Flow cytometry technology Dedicated optical counting channel for Basophil measurement 10.4 inch large TFT touch screen with user-friendly software Large storage capacity: Up to 1,50,000 samples Throughput:60 samples/Hour Compact Two kinds of lyse reagents are located inside of BC-5130, which helps the small labs to save space. BC-5130, the 5-part hematology analyzer offers a great solution for clinical labs, especially for those who have limited space. Its compact foot-print is a result of innovative technology improvements, including miniaturized semi-conductor laser source, highly integrated electronic boards and optimized liquid handling system. BC-5130 inherits it’s convenient and proven powerful software design from BC-6800 and BC-3600 platforms, the friendly interface is ideal for small sized labs. Running capillary blood through the sample probe directly is more convenient for the users in children’s hospitals, etc. For Prediluted mode, BC-5130 has higher dilution ratio than other 5-part hematology There’s NLR parameter in each CBC+DIFF result. Neutrophil-to-lymphocyte ratio (NLR) is calculated by dividing neutrophil count by lymphocyte count, usually from peripheral blood sample. In laboratory medicine, NLR is used as a marker of subclinical inflammation. According to clinical studies, NLR can be used as a prognostic factor of severe illness in COVID-19 patients. BC-5130 supports bi-directional LIS with test results and patient information. HL7 protocol is supported as well. Technology Compared with traditional helium neon laser or argon laser, semi -conductor laser has smaller size, lower cost and longer life cycle.

Send Message
product image
Clinical Chemistry

The SAL 9000 Modular System delivers high throughput of chemistry and immunoassay testing by integrating Mindray BS-2000 Chemistry Analyzer and CL-6000i Chemiluminescence Immunoassay Analyzer, and new Sample Processing line SPL 2000. With patented automatic serum analysis design, SAL 9000 not only helps you optimize the management of lab space and manpower, it also offers highly reliable test results. Product Specification Automation Fully Automatic Brand Mindray Model Name/Number SAL 9000 Assays Clinical Chemistry Power Supply 230 V Reaction Cuvette Reusable Cuvette Storage 300000 Samples Features Seamless Integration Usage/Application Lab Wavelength 5000nm Number Of Reagent Positions 4 Weight 130kg Frequency 50 Hertz Power 45 Watt Product Description The SAL 9000 Modular System delivers high throughput of chemistry and immunoassay testing by integrating Mindray BS-2000 Chemistry Analyzer and CL-6000i Chemiluminescence Immunoassay Analyzer, and new Sample Processing line SPL 2000. With patented automatic serum analysis design, SAL 9000 not only helps you optimize the management of lab space and manpower, it also offers highly reliable test results. Features Maximize laboratory efficiency Integration: Optimize your lab’s customized arrangement with better automation system Efficiency: High-throughput chemistry and immunology modules for longer walk-away time Reliability: Ingenious and comprehensive analytic system provides reliable and accurate results Easy operation: Fully automated design,user-friendly operation interface and intelligent software function

Send Message
product image
Laboratory Usage

Product Description We are engaged in manufacturing and supplying of flamephoto Meters. This is a measuring device for ascertaining presence of metal ions like calcium, potassium, lithium and sodium in the inorganic chemical compounds. Most flamephoto meters are equipped with sodium or potassium filters. We supply both single and dual chambers flamephoto meters to cater the varying needs of our esteemed clients. Specifications: Digital Flame Photometer( Single chamber) Model No. Ist Lab-65 Digital Flame Photometer (Single Channel) with filter (NA K) 3 1/2 digit LED display (PPm)along with compressor and other accessories Ca Li filter can be provided on request. Digital Flame Photometer (Dual Channel) Model No. Ist Lab-66 Single aspirations,with filter (NA K).Final result in ppm,2 1/2 digit dual LED display for simultaneos result along with compressor accessories

Send Message

Still searching for
lab space?