Jaipur
+918529833535

'kg safety information'

Items tagged with 'kg safety information'

product image
Clinical Chemistry

Best Semi Automatic Biochemistry Analyzer AT Smart from Accurex. AT SMART is a Biochemistry/Clinical Analyzer with a user-friendly and the human interface is via touch screen. It measures the optical densities of samples & calculates the sample concentration which are used for biochemical investigation. This Biochemistry Machine operates from near UV to visible range. Semi Auto Analyzer AT SMART is CE certified and has undergone rigors testing before being delivered to customers. About •SMART MAINTENANCE •SMART LIS •SMART INVENTORY MANAGEMENT REDUCED ERRORS: IT allows for the accurate collection of data, automated workflows & minimized waste. SAVES TIME: Patient monitoring can be done in real-time, saves engineers visiting time. BETTER PATIENT EXPERIENCE: A connected laboratory system creates an environment that meets each patient’s needs. INSTRUMENT BREAKDOWN MANAGEMENT: Real-time data helps to monitor instrument performance. ONLINE REACTION CURVES: • Real time reaction curve with special • Flagging gives confidence in patient reports. INTELLECTUAL SOFTWARE: • User friendly Device. • 150 Direct access test keys gives freedom to select parameters easily. • Availability of different assay modes. DRY BATH INCUBATOR: • Dry bath incubator with 12 test tube positions • Mini size with 15 minutes start up time FEATURES: •Remote access & monitoring via Internet •150 test parameters •Built-in thermal printer to print results, enzymatic curves and standard calibration curves •Large graphic display with real time graph display for enzymatic reaction •Touch screen interface with dynamic test access key SPECIFICATIONS: Methodology- • Absorbance • Endpoint with standard, factor, sample blank & diffrential • Two-point (fixed time) and multi point kinetics • Multi standard calibration • Mono or bi-chromatic reading • Turbidimetry Optical System- • Principle: photometry • Range of measurement: 0.0-3.0A • Spectral range selection: Automatic via filter wheel • Filters: 340, 405, 505, 546, 578 and 630 nm plus two free position • Bandwidth:10nm (+/- 2nm) • Light source: Life Long Halogen lamp • Blanking: Automatic • Detector: Silicon Photodiode Photometer- • Peltier regulated 25ºC, 30ºC and 37ºC • Flow cell of 18 µ L • Continuous flow system with peristaltic pump • Programmable Sipping Volume Memory- • 150+ User Defined Test Programs • 1000 test results in instrument memory and unlimited test resultresult storage via cloud • Reagent Blank • 2 Level of QC Quality Control- • Levy-Jennings chart using westgard’s rules • 30 Normal and abnormal QC values for selected test User Interface- • Graphic LCD back Lit 240×64 pixels • Touch Screen input • Data port and cloud connectivity • Type : Graphic thermal printer Power & Dimensions- • Voltage : 220 V • Frequency : 50 Hz • Maximum power : < 150 VA • Maximum relative humidity : 75% • Compact form factor • Weight: < 6kgs Safety Information Precautions • Instrument should be operated only by authorised or trained personnel • For any reasons, unauthorised personnel should not be engaged for servicing or removing the cabinet • Power source should be regulated either by voltage stabilizer or regulated power back up (UPS). If inverter is been used, please ensure there exists a voltage stabilizer • Reagents recommended by the company to be preferably used • Flow cell needs to be rinsed regularly with the company recommended flow cell cleaning solution • User is requested not to use any other pointing devices other than being supplied by company while operating touch screen • The operating environment should be clean and protected from direct sunlight • During the day at the end of the work, it should be ensured that flow cell is always filled with distilled water • During transport / longer duration of shut down, th Direction for Use Please ensure that the power source is properly grounded and voltage between Line and Ground is less than 2V AC – 5V AC. • Please ensure that the instrument is placed on a firm table, clean environment, and sufficient ventilation space. • Switch On the instrument. • Instrument will run its own internal diagnostic routines, to ensure proper working of critical functions. • Allow the instrument to stabilize for 10 minutes. • During the stabilization time, please wash the flow cell with cleaning solution and distilled water for at least two times. • During shut down, ensure that the flow cell is cleaned with flow cell cleaning solution and rinsed thoroughly using distilled water. • For overnight shutdown, please ensure flow cell is filled with distilled water. • Cover the instrument with the given dust cover Other Info GENERAL INFORMATION While installing and setting up the instrument, few safety warnings and general precautions described in the further sections must be observed. A. Power Supply : • Power source should be grounded and have either servo stabilizer or regulated power back up • Power cord should be CE , CSA and UL marked • Voltage : 115 – 230 Volts ± 10% 50 – 60 Hz • Grounding: Make sure that electrical power source is properly grounded.

Send Message
product image
Clinical Chemistry

Find the Best Semi Automatic Biochemistry Analyzer from Accurex. Buy Acculab At 112 Plus (Semi Auto Biochemistry Analyzer) which is the best Biochemistry Machine with numerous features like Filter Check, Self-check operation for optical filters, Checks the absorbance of each of the 7 filters & free position, Ensures that all the filters are in good working condition. This Biochemistry Analyzer has Improved ergonomic touch screen display, ensures strain free viewing with End point, kinetic, fixed time & absorbance mode. FILTER CHECK • Self-check operation for optical filters. • Checks the absorbance of each of the 7 filters & free position. • Ensures that all the filters are in good working condition. WORKLIST • A unique facility by which a worklist can be prepared for every sample ID. • Printouts can be taken by sample ID or test parameters. • Print by ID : Ensures that no test is left out for a particular ID. • Print by Test : Ensures that all reagents / working solutions are prepared in correct volumes preventing wastage. • The system flags any test which is missed out for a particular ID, ensuring all assay panel is completed. LAMP SAVING • Lamp saving option available ensuring long lamp life. • The lamp can be turned off in case of sporadic sample workload ALARMS • Audio alarm is sounded when results are higher (S) or lower (L) than reference range ensuring that all abnormal samples are flagged for further review. • Improved ergonomic touch screen display, ensures strain free viewing • End point, kinetic, fixed time & absorbance mode • Single & bichromatic measurement • Memory : 3200 results • 112 programmable channels • Calibration modes – 1 standard / multi-point linear / multi-point non-linear • Easy-access maintenance chamber ensures efficient uptime management • Real-time reaction curve display • Anti-vibration & anti-disturbance optical system ensures highly accurate results • Option of 7 filters (340 – 630 nm) & 1 free position • Comprehensive quality control program with L-J graph • Lamp saving feature to prolong lamp life • Audible / visual alarm available • Easy-tear printer design Methodology: End point, kinetic, fixed time & absorbance Calibration: Single standard/multi-point linear/multi-point non-linear Programmable channels: 112 Memory: 3200 results Quality control: Comprehensive QC software with L-J graph Light source:Quartz-Halogen lamp 12V / 20W Photometric range: 0.0000 to 3.0000 Abs, Resolution : 0.0001 Abs : Drift : 0.002 Abs/hour Wavelength range: 7 standard filters: 340, 405, 492, 510, 546, 578, 630 nm & 1 free optional position ; Half Bandwidth < 8 nm : Stray light : < 1.0 % at 340 nm, Stainless steel body with quartz window; Optical path 10 mm Flowcell: Stainless steel body with quartz window; Optical path 10 mm Measuring volume: 32 μl Programmable aspiration volume:: 500-2000 μl Temperature control: Peltier elements : 25°C, 30°C & 37°C ±0.1°C Input: Ergonomic LCD touch screen display Printer: Built-in high speed thermal printer Interface: RS-232 serial port Dimension / Weight: 450 x 360 x 140 mm / 11.5 kgs Operating environment: Temperature: 15-30°C ; Humidity: 20-80 % Power requirement: AC 110-220 V ±10%, 50/60 Hz Safety Information • The position of the LCD display has been designed to reduce cervical (neck muscle) strain during continual use. • The aerial view display design makes it possible to view the screen from multiple perspectives, (standing or sitting, with equal clarity). Direction for Use • A unique facility by which a worklist can be prepared for every sample ID. • Printouts can be taken by sample ID or test parameters. • Print by ID : Ensures that no test is left out for a particular ID. • Print by Test : Ensures that all reagents / working solutions are prepared in correct volumes preventing wastage. • The system flags any test which is missed out for a particular ID, ensuring all assay panel is completed. Other Info • Improved ergonomic touch screen display, ensures strain free viewing • End point, kinetic, fixed time & absorbance mode • Single & bichromatic measurement • Memory : 3200 results • 112 programmable channels • Calibration modes – 1 standard / multi-point linear / multi-point non-linear • Easy-access maintenance chamber ensures efficient uptime management • Real-time reaction curve display • Anti-vibration & anti-disturbance optical system ensures highly accurate results • Option of 7 filters (340 – 630 nm) & 1 free position • Comprehensive quality control program with L-J graph • Lamp saving feature to prolong lamp life • Audible / visual alarm available • Easy-tear printer design

Send Message
product image
Hematology

Buy the Best 5 Parts Hematology Analyzer – ACCULAB CBC 560+. This Hematology Analyser Machine is an advanced and automatic hematology analyzer, comprising 5 parts, 29 parameters, and 3 histograms assay, offers throughput of 60 tests/hour. Features: Tri-angle laser scatter, Flow cytometry method, Impedance method for RBC and PLT counting and Cyanide-free method for HGB test along with 3D holographic scattergram to display the accurate 5 part differentiation of WBC. Equipped with a 14 inch touch screen and large storage capacity for 100,000 results, this hematology analyzer has interface of 4 USB ports, 1 LAN port Bi-direction LIS, support HL 7 protocol, Internal RFID reader. With CBC mode, CBC+DIFF mode, Venous whole blood, Capillary whole blood and Prediluted test mode, this hematology analyzer is an ideal unit for white blood cell counts, complete blood Measuring principle Tri-angle laser scatter, Flow cytometry method, Impedance method for RBC and PLT counting, Cyanide-free method for HGB test Sample volumes CBC+DIFF mode: ≤ 20 μl CBC mode: ≤ 10 μl Throughput 60 tests/hour Assay Items 29 parameters, 3 histograms Display 14 inch touch screen Storage 100,000 sample results, including histograms, scattergrams and patient information Parameter WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PCT,PDW, P-LCR, P-LCC, NEU%, LYM%, MON%, EOS%,BAS%,NEU#, LYM#, MON#, EOS#, BAS# 4 Research parameter: ALY%, ALY#, LIC%, LIC# Performance Item Linearity range Carry Over CV WBC 0-300 × 109/L ≤ 0.5% ≤ 2.0 % RBC 0-8.00 ×1012/L ≤ 0.5% ≤ 1.5 % HGB 0-250 g/L ≤ 0.5% ≤ 1.5 % PLT 0-3000 × 109/L ≤ 1.0% ≤ 4.0 % Interface 4 USB ports, 1 LAN port Bi-direction LIS, support HL 7 protocol, Internal RFID reader Power Consumption 400 VA Power Supply AC 220V±10%, 50/60Hz, 110V±10%, 60Hz Packaging dimension (W×D×H) 670 × 590 × 790 mm Gross Weight 53 kg Safety Information All the samples, controls, calibrators, reagents, waste and areas contacted with them are potentially biohazardous. Wear proper personal protective equipment (e.g. gloves, lab coat, etc.) and follow safe laboratory procedures when handling them in the laboratory.

Send Message
product image
Hematology

Buy the Best Automated Hematology Analyzers – Acculab CBC 360 Neo. This Hematology Analyser Machine is Truly Automated for self-checking, background test, calibration, sampling, dilution, mixing, printing, dormancy, alarms, cleaning and maintenance. CBC 360 Neo is 3 part hematology analyzer from Accurex & is Automated for Walk-away Operations. Dual Chamber: Measurement of RBC / platelets & WBC / HGB in different chambers ensure accurate counting in a short time. The micro-aperture sizes of both the chambers are well designed to avoid error due to cell misclassification Automation for Walk-away Operation: Auto Self-check : Automatic aspiration of reagents & rinsing of tubings on startup Auto Blank : Background test is run automatically on startup Auto Print : Automatic printing of report with / without histogram Auto Sleep : Dormancy status is entered after a set period of non-operation Auto Alarms : Audio / visual alarms in case of system errors & abnormal results Auto Clean : Automatic rinsing options available to maintain the system Dual Chamber: Measurement of RBC / platelets & WBC / HGB in different chambers ensure accurate counting in a short time. The micro-aperture sizes of both the chambers are well designed to avoid error due to cell misclassification Specifications: Measurement principle: Electrical resistance for counting RBC, WBC & Platelets Colorimetric estimation of HGB at 540 nm Parameters: WBC, LY, MO, GR, LY%, MO%, GR%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR Throughput: 60 samples/hour Micro-aperture: WBC : 100 um RBC / PLT : 68 um Sample type: Whole blood or pre-diluted sample Sample volume: Whole blood (venous blood) : 10 ul Chamber: Pre-diluent (capillary blood) : 20 ul, Pre-diluent (capillary blood) : 20 ul Reagents: Dual chamber : RBC / Platelets & WBC / HGB Quality control: 4 QC options : L-J, X-B, X-R & X QC, Graphs plotted with 31 data points Data memory: Upto 100,000 (with histogram) Display: 10.4 inch LCD with 640 x 480 resolution Printer: Built-in thermal printer Interface: Support RS-232C, standard network port and USB; keyboard and mouse Operating environment: Temperature : 15˚C – 35˚C, Humidity : 85% RH Electrical specification: Voltage : AC 110V/230V 23V Frequency : 50/60 Hz, Power : 180W Fuse specification : 250V/3A Dimensions / Weight: 670 x 515 x 640 mm / 27.5 kgs Specification Acculab CBC 360 Neo – Fully Automated Hematology Analyzer Features: 3-part differentiation of WBC Automated for — self-checking, background test, calibration, sampling, dilution, mixing, printing, dormancy, alarms, cleaning and maintenance High processing speed : 60 samples/hour Multi-parameter estimation : 20 parameters categorized according to corpuscle type for easy reporting Direct command keys for Mode, Prime, Flush, Drain & Record / Print for faster operation Run / Standby indicator lights denote the analyzer status i.e. test is being run or analyser is ready to test Whole blood/ Pre-diluent indicator lights denote the sample type in use i.e. whole blood/ pre-diluent Dual sample mode with low sample volume: Whole blood (venous) mode : 10 ul; pre-diluent (capillary) mode : 20 ul Audio alarm indication for abnormal findings or system errors 4 QC methods : L-J, X-B, X-R & X QC Comprehensive QC graphs with 31 data points for each parameter Internal & external probe cleaning facility Dormancy mode available to reduce power consumption Memory : 100,000 (with histogram) Safety Information • Large 10.4 inch single screen color display of all 21 parameters and 3 histograms • Sequential arrangement of WBC, RBC & PLT parameters for convenient reporing •Easy to understand & icon-based arrangement of menu for fast and convenient testing Direction for Use • WBC Histogram: R1, R2, R3, R4 & RM indications on histogram show specific abnormalities in the histogram & the probable causes • Platelet Histogram: PM indication is given when the boundary between PLT & RBC is ill-defined thus avoiding misclassification Other Info High voltage cautery function is useful in disintegrating obstinate protein or serum clog in the tubing

Send Message
product image
Instruments

A high-end ventilator featured with 1080P HD wide screen, combines an intuitive customized UI with powerful assistive tools and modules. Operate with Ease In the modern busy clinical environment, ease of use is a fundamental requirement for all medical devices. With this in mind, the new SV800/SV600 ventilators enable clinicians to set and deliver ventilation therapies quickly and easily via the intelligent ergonomic design and flat user interface. Intelligent Decision Making Ventilation modes and decision-supporting tools like SBT are developed on the basis of clinical needs and professional guidelines to help free up medical personnel’s time on device operation and focus more on their patients. p68-s4 Extensive ventilation therapy and decision support tools Smart ventilation solution: AMV TM + IntelliCycle TM Emergency solution: CPRV TM Sequential treatment regimen: Non-invasive ventilation & high flow oxygen therapy Dual channel auxiliary pressure measurements Lung protection kit Expandable Capabilities Securing your devices future is reliant on being able to expand your devices capabilities by interacting or integrating new features and technologies. The SV800/SV600 ventilators allow just this. Thanks to latest software and platform it is utilizing, your device is ready to embrace new technological advancement with ease. p68-s0-0 Integrated neonatal module with tidal volume setting down to 2ml Plug & Play modules , including SpO₂, mainstream or sidestream CO₂ Backup air supply in case of central air supply failure and during intra-hospital transport Seamlessly connected to the hospitals clinical information system via the Mindray BeneLink and eGateway modules, or directly via the HL7 p68-s5 Brand - Mindray Model Name/Number SV800 Patient Age Group Adult, Pediatrics & Neonatal Tidal Volume For adult : 100 to 4000 ml, For Pediatric 20 to 300 ml, For neonatal : 2 to 100 ml Ventilation Mode V-A/C, P-A/C, V-SIMV,P-SIMV, Duolevel, CPAP, PSV, APRV, PRVC, NIV, PRVC-SIMV, AMV, CPRV, PSV-S/T, nCPAP, VS Respiratory Rate For adult/pediactrics : 1 to 100/min,for neonate :-1 to 150/min Additional Details Weight 45 kg ventilator + 16.3 kg trolley Plateu (%) OFF, 5% to 60% Peak airway pressure 0 to 100 cm H2O SIMV Rate ,Cycle/min 1 to 60 rpm Mounting type Trolley I:E Ratio 1:10 to 4:1 Touch screen 18.5 inch color active matrix TFT touch screen RSBI 0-9999/1/(L-min) Features Customizing the UI Graphic guidelines Single level menu design Dual channel auxiliary pressure monitore

Send Message
product image
Medical Equipment

With state-of-the-art screen technology, BeneVision N Series patient monitors deliver clear, multi-color, wide-format displays for users to capture and review information at a glance. With multi-touch operation, users can control the monitor and review patient data quickly and easily. BeneVision N Series provides the world's best monitoring technologies for you, with new applications being developed. Perfect hemodynamic monitoring solution, not only provides a variety of measurement methods, ICG, PiCCO, ScvO2, C.O., but also provides comprehensive analysis tool – HemoSight™. HemoSight™ focuses on hemodynamic treatment process, and provides appropriate tools for each stage. Advanced modular regional tissue oxygenation measurement -- INVOS rSO2. Volumetric capnography & metabolic measurement help to evaluate the adequacy of ventilation and determine the ventilator setting effectively, and improve the safety of weaning and extubation. Powerful Clinical Assistive Applications (CAAs) to support efficient decision making when time is critical. Each CAA focuses on major clinical workflow challenges that individual departments face. Solutions optimized for each point of care At every point of care, such as ICU, CCU, NICU, OR, PACU, ER, BeneVision N Series patient monitors always provide a suitable solution to meet your clinical needs for monitoring your patient's status anywhere, anytime, even on your way through mobile devices. With excellent transport solution, BeneVision N Series patient monitor brings a smooth workflow and safe data management through the entire care process. BeneVision takes less time to operate, and helps you understand the patient's variables quickly. With HL7,BeneVision N Series patient monitors can directly connect to the hospital clinical network.BeneVision N12 is capable of monitoring multiple parameters simultaneously both at bedside and during transport. IT structure designed for seamless connectivity Mindray patient monitoring system incorporates extensive network adaptability to integrate with the hospital's current network infrastructure, ensuring that critical data is on hand for clinical decision making - and is integrated with the patient record. Mindray's central station and eGateway further enhances the connectivity of BeneVision to your clinical world. Bedside devices data and other clinical systems data are shared to support your diagnosis and clinical decisions.

Send Message
product image
Instruments

The new and improved RTR-1 uses an image processing method. During measurement, the lateral flow device is captured using a 5-mega pixel camera and the picture is analyzed using image processing algorithms for identification of either presence or absence of test line bands or test line band intensity levels. The reader converts the image into a grayscale and then classifies the intensity levels of the image in 0 to 255 grayscale range. The image processing algorithm undergoes various levels of filtering and segmentation to yield the correct intensity levels from the picture. Based on the preconfigured intensity levels, the reader classifies the band intensity and reads out the results as either positive or negative. ACCURACY: Less than 3% intra-run CV Eliminates subjective interpretation by operator FLEXIBILITY: Single mode for low volume test setting Batch mode allows for high volume test setting Result output as semi-quantitative line intensity and visual image EASE-OF-USE: Built in barcode reader provides faster test setup Touch screen interface for easy operation Lightweight (0.7kg) and portable DATA MANAGEMENT: Results presented on screen, on a printout or uploaded to reader database Storage capacity of 1,000 test results (including images) Laboratory Information System (LIS) and Wi-Fi compatible Human Machine Interface 4-inch resistive touch screen Camera 5 mega pixel CMOS camera Barcode Scanner Integrated 1 dimensional barcode scanner Printer 48 mm inbuilt thermal printer Mode Single mode and batch mode operations Port/USB Data export and software upgrade through 2 USB ports Storage Storage capacity of 1000 test results (including images) Result output “Positive or Negative” as well as quantitative test line intensity Power 12V 2A Processor ARM Cortex-A53 Platform Embedded Linux Dimension 220 mm X 170 mm X 110 mm (L x B x H) Weight 0.7 kg (Approx CATALOG # PRODUCT RTR-1 Rapid Test Reader OTHER PRODUCTS YOU MIGHT BE INTERESTED IN.. CATALOG # PRODUCT ADX-110 ELISA Reader ADX-120 Microplate Washer

Send Message
product image
Instruments

CLIAlyzer is an intuitive bench-top chemiluminescent analyzer allowing for quick operation and use. CLIAlyzer delivers results when paired with our RapidLight tests. Laboratories can run multiple specimen options and six tests simultaneously, providing up to 24 test results per hour. The CLIAlyzer is an in vitro diagnostic device used for the quantitative determination of concentrations of various analytes found in serum, whole blood, or plasma specimens. Compact size Automated walkaway system Easy operation with 7-inch touchscreen Barcode reader reduces manual entry errors Results on screen, on a printout, or uploaded to database Storage capacity of 100,000 test results Laboratory Information System (LIS) connectivity High accuracy and precision with highly sensitive PMT for signal detection Assay results as quick as 15 minutes (test-specific) Compatibility with whole blood, serum, plasma (test-specific) Six cartridge positions Automatic detection of test parameter through barcode on test strip, thus reducing any user-related errors Low maintenance analyzer due to no storage of buffer System: Automated chemiluminescence system Interface: 7-inch color touch screen Methodology: Magnetic particle-based assay with chemiluminescence detection Reaction mode: Batch mode Sample type: Serum, plasma, whole blood (test specific) Sample positions: 6 Volume: 420mm x 610mm x 321mm Weight: 35kg Connectivity: USB, RS232, LIS connection Barcode Scanner: 1-D & 2-D barcode

Send Message
product image
Digital Spectrophotometer

Detector Silicon Photodiode Path Length 10 mm Range 340 to 960 nm Resolution 0.1% T,0.001 Abs Light Source 6V, 1 Amp, Tungsten Halogne lamp Grating 600 lines/cm Specifications: Range 340 to 960 nm Resolution 0.1% T,0.001 Abs Output % T: 0 to 100%, Abs:0 to 1.999 Conc: 0 to 1999 Detector Silicon Photodiode Light Source 6V, 1 Amp, Tungsten Halogne lamp Grating 600 lines/cm Path length 10 mm Spectral Bandwidth 10 nm Wavelength Resolution 1 nm on Display 2% digit LED Wavelength Accuracy 1 nm Repeatability ±1 nm Read out 3½ digit LED, 1 nm step Operating Temp 5 to 45°C Path length 10 & 50 mm in Model LT-38 Additional Information: Item Code: UV-Mini-1240 Yes! I am interested Spectrophotometer REQUEST CALLBACK Spectrophotometer Ask for Price Product Price :Get Latest Price Product Details: Wavelength Range 340-950 nm Mobility Portable Brand Spectronic Model No / Item Code Spectronic-20D Photometric Range 0 to 100%T 0 to 1.95 Abs 0 to 1999 Conc Display Digital Weight 8.2 kg (18 lbs) Power Requirements 100/115 V, 50/60 Hz; 220/240 V We are the Manufacturers of Spectrophotometer. Product Specifications Spectronic 20 Part Number 333182000 Series Spectronic 20D Part Number 333183000 Series Spectral Slit Width 20 nm 20 nm Wavelength Range 340 to 950 nm 340 to 950 nm Wavelength Accuracy /- 2.5 nm near 525 nm /- 2.5 nm near 525 nm Display Meter LED 5 1/2" mirrored scale, linear %T, Abs, Conc, Concentration Factor %T, non-linear Abs Wavelength Photometric Range 0 to 100%T 0 to 100%T 0 to 2 A 0 to 1.95 Abs 0 to 1999 Conc 0.1 to 1000 Concentration Factor Photometric Accuracy /- 2%T /- 2%T Photometric Noise /- 0.5%T /- 0.5%T Photometric Drift 1.0%T/Hour 1.0%T/Hour Accessory Output 1.0 VDC nominal at 100%T 1.0 VDC nominal at 100%T RS-232C Serial I/O Port Stray Radiant Energy <0.5%T over entire wavelength range*

Send Message

Still searching for
kg safety information?