Jaipur
+918529833535

'infinite liquid ldh'

Items tagged with 'infinite liquid ldh'

product image
Clinical Chemistry

Infinite ADA 60 Diagnostic Reagent (R1 1 X 20ml: R2 1 X 10 ml) from Accurex. Infinite ADA reagent is used for direct quantitative determination of Adenosine deaminase (ADA) activity in human serum, plasma and other body fluids. The Reagent is a ready-to-use two liquid reagent system & can be performed in 11 minutes at 37° C. ADA is also know as Adenosine Deaminase which eliminates a molecule called deoxyadenosine, which is generated when DNA is broken down. About Infinite ADA is a reagent set for direct quantitative determination of Adenosine deaminase (ADA) activity in human serum, plasma and other body fluids. Infinite ADA is a ready-to-use, two liquid reagent system. With Infinite ADA, the assay is linear upto 200 U/L. Infinite ADA assay can be performed in 11 minutes at 37° C. Principle ADA catalyzes deamination of adenosine to inosine which is then converted to hypoxanthine by purine nucleoside phosphorylase (PNP). Hypoxanthine is then converted to uric acid and hydrogen peroxide (H2O2) by xanthine oxidase (XOD). H2O2 is further reacted with N-Ethyl-N-(2-hydroxy-3- sulfopropyl)-3-methylaniline (EHSPT) and 4-aminoantipyrine (4 AAP) in the presence of peroxidase (POD) to generate quinone dye. Quality Control To ensure adequate quality control, it is recommended that each laboratory should use a normal and an abnormal commercial reference control material. It should be realized that the use of quality control material checks both reagent and instrument functions together. Factors which might affect the performance of this test include instrument function, temperature control, cleanliness of glasswares and accuracy of pipetting. Other Details The reagents R1 & R2 are ready-to-use. The reagent kit should be stored at 2° – 8° C and is stable till the expiry date indicated on the label. Reagent R1 is light-sensitive & to be stored in dark. Contamination of the reagents should be strictly avoided.

Send Message
product image
Clinical Chemistry

Ready to use liquid stable reagents. Pack sizes cater to specific customer needs. High quality reagents manufactured to international standards. Categories: Clinical Chemistry, Reagents Description Reagents Technical Information KITS Albumin Alkaline Phosphatase AST/SGOT Bilirubin Direct Calcium CK-NAC Creatinine GGT LDL Direct Magnesium Total Protein Uric Acid ALT/SGPT Amylase Bilirubin Total Bilirubin Total & Direct Cholesterol CK-MB Glucose HDL Direct LDH-L Phosphorus Triglycerides Urea Kinetic (Rate BUN) Lipase information every single reagents has a diffrent price 1 pack single price.

Send Message
product image
Clinical Chemistry

Infinite Liquid a-Amylase 12 ml Diagnostic Reagent from Accurex (Pack Size : 6 x 2 ml). a-Amylase reagent is used for determination of amylase activity based on kinetic method using Gal G2 – a CNP. Amylase is a ready-to-use reagent. Normal amylase level is 40 to 140 units per liter (U/L) or 0.38 to 1.42 microkat/L (µkat/L). Infinite a-Amylase can be used on any Spectrophotometer, Discrete semiautomated & Automated analyzers. Reaction type is Kinetic. Accurex Biomedical is the first biochemical reagents manufacturing company in India About Infinite a-Amylase ‘is a reagent set for determination of amylase activity based on kinetic method using Gal G2 – a CNP. Infinite a-Amylase is a ready-to-use reagent. Infinite a-Amylase can be determined in just 21/2 minutes at 37°C. Infinite a-Amylase is linear upto 2000 IU/1. Infinite a-Amylase is a High Stability Reagent. Infinite a-Amylase can be used on any Spectrophotometer, Discrete semiautomated and Automated analyzers. Programme can be designed for any specific analyzer upon request. Pack Size : 6 x 2 ml Principle Amylase test involves use of a chromogenic substrate Gal G, – a CNP (2-chloro-4-nitrophenyl linked with galactosyl maltoside). The direct action of amylase with this substrate results in the release of more than 90% of 2-chloro-4-nitrophenol, which can be monitored by kinetic assay at 405 nm. The increase in absorbance is directly proportional to the amylase activity in the sample. Quality Control To ensure adequate quality control, it is recommended that each batch should include a normal and abnormal commercial reference control serum. It should be realized that the use of quality control material checks both instrument and reagent functions together. Factors which might affect the performance of this test include proper instrument function, temperature control, cleanliness of glassware and accuracy of pipetting. Other Details Mix thoroughly and transfer the assay mixture immediately to the thermostated cuvette and start the stopwatch simultaneously. Record the first reading at 60 second and subsequently three more readings with 30 seconds interval at 405 nm.

Send Message
product image
Clinical Chemistry

EM 360 is a Fully Automated Clinical Chemistry Analyser which is time tested and proven technology. It is designed to provide the most demanding productivity, speed and operational ease. EM 360 with a throughput of 360 tests/hour offers flexibility in operation and rugged performance to win against high workload, tight deadlines, multiple tasks and complexity of testing. It yields high quality results for virtually any biochemistry test to deliver quick, efficient and consistent performance. Product Features: Automated, Discrete, Patient prioritized, Floor model Based on proven technology, Diffraction Grating Separate probes for Reagent R1 & R2 and dedicated probe for sample Low reading volume of 200 µl only Onboard cooling for reagents to enhance the reagent stability Barcode for reagents & samples (Optional) Wide test menu Product Applications: End Point Reactions: Glucose, Cholesterol, Triglycerides, Albumin, Total Protein, Uric Acid, Calcium, Magnesium, Bilirubin Total, Bilirubin Direct Kinetic Reactions: SGOT, SGPT, GGT, LDH, CK, CK MB, ALP, ACP, Amylase, Lipase Two Point Rate Reactions: Urea, Creatinine Immunoturbidimetric Chemistries: RA, CRP, ASO, Direct HDL, Direct LDL, Apo A, ApoB, Lp (a) Special Chemistries: HbA1c, Iron, Ferritin, Phosphorus, Microprotein, Ammonia, Bicarbonates System Type: Discrete, automated, random access, patient prioritized clinical chemistry analyzer Throughput: 360 tests / hour photometric and 600 tests / hour with ISE* (*optional ISE with Na+, K+, Cl-, Li+) Analytical Methods: 1-Point, 2-Point, Rate-A, Rate-B, Direct Potentiometry (optional) Barcode Reader: For reagents and samples (optional) Reaction Tray: 60 hard glass cuvettes Reaction Mixing: Stirrer with variable speed Minimum reaction Volume: 150 μl with maximum 200 μl reading volume On-board Laundry: 5 stage cleaning, 2 stage drying Photometer: Multi-wavelength diffraction grating with 12 wavelengths (340, 376, 415, 450, 480, 505, 546, 570, 600, 660, 700, 750 nm) OD Range: 0.0 - 3.0 Light Source: Halogen lamp Detector: Silicon photo-diode Water Consumption: < 10 litres Programmable Parameters: Default system pack parameters + upto 99 user defined parameters, Unlimited profile and unlimited calculation items Quality Control: QC plot data with QC rules. Provision for lab mean. Twin plot Calibration: K-Factor, Linear (1, 2 point & multipoint), 4P and 5P Logit-log, cubic spline, exponential, polynomial, On-board serial dilution for calibrator Power Requirement: AC 220 V ± 10 %, 50 Hz or AC 110 V ± 10 %, 60 Hz Power Consumption: 800 VA Dimension (mm): Approx. 675 (W) x 840 (D) x 1120 (H) Weight: Approx. 150 kgs. SAMPLE HANDLING Sample: Serum, Plasma, Urine, CSF, Whole blood, other Sample Unit: 82 positions for samples, blank , controls, calibrators, STAT sample Sample Pipetting: 2 - 70 µl (adjustable in 0.1 µl step) for Biochemistry, 70 µl fixed for ISE Capacitance probe with liquid level sensing & vertical obstruction detection, serum indices Auto Rerun: Repeat with same, increased or decreased volume ( upto 1:150) Sample Tubes /Cups: Primary tubes of 5 ml, 7 ml, 10 ml and sample cups REAGENT HANDLING Reagent Tray: 50 positions for reagents with onboard cooling Reagent Pipetting: R1: 50 - 300 µl (adjustable in 1 µl step) R2: 10 - 200 µl (adjustable in 1 µl step) Capacitance probe with level sensing & vertical obstruction detection SYSTEM INTERFACE: Analyzer-PC: USB PC - Host Computer: Bidirectional TCP / IP & RS - 232 PC - Printer: USB Operating System: Windows Based Database: Unlimited Results

Send Message
product image
Rapid Test

Intended Use Advantage Malaria Card is a visual, rapid and sensitive immunoassay for the qualitative differential detection of P.falciparum (HRP-2) and P.vivax (pLDH) malaria antigen in human blood only. Salient Features Rapid, visual antigen based test for detecting infection with P.falciparum (HRP-2) & P.vivax (pLDH) malaria parasite in whole blood. Excellent Sensitivity & Specificity. See through Device for easy result interpretation. Longer shelf life of 30 months at 4-30° C. Easy to interpret colour bands Results within 20 minutes.

Send Message
product image
Rapid Test

Intended Use Advantage PAN Malaria Card is a rapid, visual and sensitive immunoassay for the qualitative diagnosis of all four Plasmodium Species (P.falciparum/P.vivax/P.malariae/P.ovale) based on pLDH antigen in human whole blood only. Salient Features Detects infection with Plasmodium species(P.falciparum/P.vivax/P.malariae/P.ovale) Excellent Sensitivity & Specificity as per WHO Malaria RDTs Evaluation. See through Device for easy result interpretation. Longer shelf life -30 months, storage at 4-30° C. Results within 20 minutes.

Send Message
product image
Rapid Test

Intended Use Advantage PAN Malaria Card is a rapid, visual and sensitive immunoassay for the qualitative diagnosis of all four Plasmodium Species (P.falciparum/P.vivax/P.malariae/P.ovale) based on pLDH antigen in human whole blood only. Salient Features Detects infection with Plasmodium species(P.falciparum/P.vivax/P.malariae/P.ovale) Excellent Sensitivity & Specificity as per WHO Malaria RDTs Evaluation. See through Device for easy result interpretation. Longer shelf life -30 months, storage at 4-30° C. Results within 20 minutes.

Send Message

Still searching for
infinite liquid ldh?