Jaipur
+918529833535

'ilqc options'

Items tagged with 'ilqc options'

product image
Clinical Chemistry

ADVIA 2400 Chemistry System The right balance of speed and efficiency The ADVIA® 2400 Clinical Chemistry System manages the most demanding workloads and meets high turnaround-time (TAT) goals. Its menu includes methods for testing drugs-of-abuse, therapeutic drugs (TDM) and new assays such as cystatin C and CardioPhase® hsCRP. The ADVIA 2400 Clinical Chemistry System offers: High throughput of up to 2400 tests/hour (1800 photometric and 600 ISE) to manage heavy workloads Rapid, consistent, 2-second cycle time for faster tube speed and test throughput User-defined automatic repeat, dilution, and reflex testing Large onboard reagent capacity and optional concentrated reagents help to minimize intervention demands Refrigerated onboard storage of controls and reagents for extended stability and increased productivity Automation-ready design: no additional hardware required Features & Benefits The ADVIA 2400 Clinical Chemistry System meets today’s high turnaround-time goals with a throughput of up to 2400 tests/hour. In addition to assays for general and specialty chemistries, its menu includes assays for specific protein measurement, drugs-of-abuse testing (DAT), and therapeutic drug monitoring (TDM). Interesting new assays such as cystatin C, HbA1c with automated sample pretreatment, and CardioPhase® hsCRP can now be included in your routine testing. The ADVIA 2400 Chemistry System pushes productivity levels while maintaining the reliability and stability that keep laboratories up and running. A rapid, 2-second probe cycle time maximizes tube speed and test throughput and combines with the system’s efficient automation-readiness to provide the turnaround time needed for high-volume laboratories Superior Speed and Productivity Throughput of up to 2400 tests/hour (1800 photometric and 600 ISE) to manage the heaviest workloads Rapid, consistent, 2-second cycle time Throughput of 200 tubes per hour, even when running three ISE tests and nine photometric tests per sample Automatic Sample Retain technology, auto-repeat, auto-dilution, and auto-reflex testing Automation-ready Point-in-space aspiration enables connectivity to a track. Redundant sample loading provides built-in backup and easy handling of non-routine samples. Direct sampling from track prevents tubes being detained at an analyzer and reduces aliquoting. Minimal Need for Operator Intervention Minimal-maintenance ISEs Large onboard reagent capacity and optional concentrated reagents for fewer interruptions No-maintenance, 37°C incubation oil bath Auto-calibration and auto-QC from refrigerated onboard calibrators and controls Microvolume technology with 32,000 tests onboard and up to 60 days' onboard stability for improved walkaway time. Concentrated reagents for increased maximum capacity. Remote diagnostics and Inter-Laboratory Quality Control (ILQC) options Exceptional Reliability Sample integrity check for icterus, hemolysis, and lipemia Sample probe with automatic clot/clog detection, liquid-level sensing, short-sample detection, and crash protection Advances in onboard reagent stability, calibration frequency, reduction in interferences, and expanded assay linearity

Send Message
product image
Clinical Chemistry

The ADVIA® 1800 Clinical Chemistry System pushes the limit of productivity. Its extensive menu allows integration of testing for clinical chemistry, drugs-of-abuse, therapeutic drug monitoring (TDM) and specific proteins such as cystatin C and CardioPhase® hsCRP. The ADVIA 1800 Clinical Chemistry System offers: Throughput of up to 1,800 tests per hour to keep pace with workload peaks 200 basic metabolic panels per hour to meet turnaround-time demands Large onboard reagent capacity and optional concentrated reagents to reduce interruptions Optimal standardization of reagents and systems for efficient consumable usage Refrigerated onboard storage of controls and reagents for extended stability and increased productivity Automation-ready design: no additional hardware required Features & Benefits The ADVIA 1800® Clinical Chemistry System pushes the limit of productivity in the core lab and meets the turnaround-time (TAT) goals of today’s laboratories. Its extensive menu allows integration of general clinical chemistry testing with testing for drugs-of-abuse, TDM, special chemistry, and specific proteins such as cystatin C and CardioPhase® hsCRP. Automation-ready design Point-in-space aspiration enables connectivity to a track, VersaCell® System. Redundant sample loading provides built-in backup and easy handling of non-routine samples. Direct sampling from track prevents tubes being detained at an analyzer and reduces aliquoting. Peak productivity Throughput of up to 1,800 tests per hour provides the speed to keep pace with workload peaks. Throughput of 200 basic metabolic panels per hour helps to meet turnaround-time demands. Automatic Sample Retain technology lets you perform reruns and dilutions without the need to retrieve primary tubes. Consolidate chemistry testing on one system with a comprehensive menu, consistent cycle times, speed, and open application capability. Total system reliability Minimal-maintenance ISEs Robust hardware and simplified software design, with automatic calibration validation and tracking Advances in reagent onboard stability, calibration frequency, interference reduction and assay linearity expansion Direct water connection Remote diagnostics and Inter-Laboratory Quality Control (ILQC) options Easy efficiency Large onboard reagent capacity and optional concentrated reagents reduce interruptions. High-resolution touchscreen delivers push-button operation. Reagent pause capability and onboard Sample Pause button make loading easy. Minimal maintenance requirements, including no-maintenance oil bath, reduce hands-on time. Sample integrity checking, include serum indices reporting, short-sample flagging, and clot detection, reducing the need for manual intervention.

Send Message
product image
Clinical Chemistry

With the built-in oxygen concentration monitoring system and effective cable management system, the HyPort R80 is capable of creating a reliable and streamlined ICU environment to ensure patient safety. Recovery The lighting system of the HyPort R80 aims to create a comfortable, near-natural light ICU environment to enhance patient recovery. 1234 1 Circadian Light Simulating 24-hour natural daylight change to reflect circadian rhythm. 2 Examination Light Up to 10,000 lux, 5-level adjustable illuminance meets various needs of head and abdominal examination. 3 Reading Light Effectively avoid invalid glare to meet the reading needs of rehabilitating patients. 4 Navigation Light Providing enough lighting with less glare for medical staff’s easy observation and intervention. Efficiency The HyPort R80 is a highly integrated bedside device management system that helps caregivers organize medical devices to meet various clinical needs. It makes efficient use of beside space with a series of easy-to-use designs, enabling a more efficient workflow for medical staff. Folding-shelf design Suitable for both portable ventilators and integrated ventilators. p46-s3-2-web Bag-valve-mask management Making sure bag valve mask is easy to access and ready for emergency situations anytime when needed. p46-s3-3-web Partition management The pump separation layout allows medical staff to easily identify infusion pumps and feeding pumps. p46-s3-4-web Smooth movement The advanced braking technology ensures stability of the column when moving. NextPrevious Variety The HyPort R80 has been designed to meet the demands of different ICU layouts to create a safer, more efficient and comfortable ICU environment with patient-centric design.ICU double room solution A Product Specification Usage/Application Hospital Brand Mindray Model Name/Number HyPort B80 Features 60 Degreepanel interface for easier plug-in of gas and electricity Color White Panel Interface 60 Degree Product Description Gas and electricity separated 60°panel interface for easier plug-in of gas and electricity Flexible movement of sliding and rotating of the distributions Additional accessories for better management of details Considerate lighting option Safer and more effective workflow Gas and electricity separated 60°panel for easier plug-in of gas and electricity Better management Customized drawer solutions Wire basket - dfferent size options available Cable management solutions

Send Message
product image
Hematology

BC-6800 Today, laboratories not only need more reliable routine CBC plus 5-part diff WBC testing by way of high processing speed, but are also looking for options that extend the analyzer's output in form of Reticulocytes, Nucleated RBCs, Fluorescent Platelet counts etc. for wider clinical application and research. On the other hand, they are restricted by limited budgets. BC-6800 can help to meet all these needs just perfectly and even exceed the expectations. Additional parameters for further clinical applications IMG(#,%) parameters provide information about immature granulocyte, including promyelocytes, myelocytes and metamyelocytes. HFC*(#,%) parameters represent high fluorescent cell population, such as blasts and atypical lymphocytes. RET(#,%) extend valuable help in the differential diagnosis and/or therapeutic monitoring of anemias. IRF is parameter concerning immature reticulocytes, which can assist in early diagnosis of anemia and monitoring the bone marrow response to therapy. InR*(#,‰) are parameters regarding infected red blood cell. The red blood cells may infected by plasmodium, which can cause malaria. * means research parameters SF Cube Technology SF Cube is a pathbreaking technology for reliable blood cell analysis, including WBC differential, Reticulocytes and NRBC with efficient flagging. After reaction with proprietory reagents, the targeted blood cells undergo 3D analysis using information from scatter of laser light at two angles and fluorescence signals. The 3D scattergram builds the power to better identify and differentiate blood cell populations, especially to reveal abnormal cell population undetected by other techniques. Minimizing interference to ensure more accurate results NRBCs are counted in a dedicated channel by SF cube method, which automatically corrects total WBC count and 5-part Diff results when NRBCs are detected. The Focusing Flow-DC method minimizes the interference traditionally encountered in DC technology to produce near gaussian histograms. PLT-O result avoids the interference from microcytic and fragmented RBCs, large platelets and/or platelet clumps by fluorescent stain, and enhances the results accuracy and sensitivity. High automation to minimize the workload Throughput for 125 tests/hour, autoloader for 100 sample tubes capacity Bi-directional LIS with HL7 or ASTM communication protocol Customizable re-exam rules allow users to define their re-exam criterion according to lab’s practice

Send Message
product image
Instruments

CLIAlyzer is an intuitive bench-top chemiluminescent analyzer allowing for quick operation and use. CLIAlyzer delivers results when paired with our RapidLight tests. Laboratories can run multiple specimen options and six tests simultaneously, providing up to 24 test results per hour. The CLIAlyzer is an in vitro diagnostic device used for the quantitative determination of concentrations of various analytes found in serum, whole blood, or plasma specimens. Compact size Automated walkaway system Easy operation with 7-inch touchscreen Barcode reader reduces manual entry errors Results on screen, on a printout, or uploaded to database Storage capacity of 100,000 test results Laboratory Information System (LIS) connectivity High accuracy and precision with highly sensitive PMT for signal detection Assay results as quick as 15 minutes (test-specific) Compatibility with whole blood, serum, plasma (test-specific) Six cartridge positions Automatic detection of test parameter through barcode on test strip, thus reducing any user-related errors Low maintenance analyzer due to no storage of buffer System: Automated chemiluminescence system Interface: 7-inch color touch screen Methodology: Magnetic particle-based assay with chemiluminescence detection Reaction mode: Batch mode Sample type: Serum, plasma, whole blood (test specific) Sample positions: 6 Volume: 420mm x 610mm x 321mm Weight: 35kg Connectivity: USB, RS232, LIS connection Barcode Scanner: 1-D & 2-D barcode

Send Message
product image
Laboratory Usage

Soil moisture meter TDR 150 Portable soil moisture meter allows you to obtain readings on the go at the press of a button. Variable rod length options provide soil moisture measurements at your ideal root zone. With new enhancements, the TDR 150 provides significant improvements in performance and measurement accuracy for optimal turf and soil environments. Increased accuracy of soil moisture (Volumetric Water Content) Measures EC (Electrical Conductivity) Measures Turf Surface Temperature Option to add on Bluetooth and GPS Data logger records approximately 50,000 measurements Industry exclusive backlit display Ergonomic handle Data collected with USB flash drive No PC interface needed Powered by AA lithium batteries Ideal for measuring containers on benches Optional IR Temp sensor to measure canopy TDR 150 SPECIFICATIONS Measurement Principle: Time - domain measurement methods Measurement Units: Percent Volumetric Water Content (VWC) Resolution: 0.1% VWC Accuracy: +- 3.0% VWC with Electrical Conductivity (EC) < 2 mS/cm Range: 0% to saturation (Saturation up to about 50% volumetric water depending on soil type) Battery/Life: 4 AA lithium batteries; approximately 100,000 readings without backlight Data Logger: 50,000 measurements EC Range: 0 to 5 mS/cm, Resolution: 0.01 mS/cm, Accuracy: +/- 0.1 mS/cm Temperature Range: -30°C to 60°C, Resolution: 0.1°, Accuracy: +/- 1°C

Send Message
product image
Instruments

Our company has created niche in the field of offering Tunning Forks to the clients. This product is rigorously tested by the team of quality controllers to ensure that our product meets expectations. Offered range is designed by professionals utilizing the quality material and technically advanced tools. Tunning Forks is available in different modified options as per the requirements of clients. This product is checked on various quality parameters before final dispatch in the market. Offered range is available to clients at affordable rates to fulfill the demands. Features: Rigid construction Low maintenance Quality approved Product Details: Material Stainless steel Application Industrial Color Silver Packing Type Box Use Medical Handle Solid

Send Message
product image
Glucometer

Item Description The Accu-Chek Softclix lancing device can help make lancing easy. Its rotatable cap offers 11 fixed depth settings for different skin types. Clixmotion technology minimizes any painful side-to-side motion of the lancet, which is why this lancing device is virtually pain-free to use. Benefits and features Virtually pain-free lancing Clixmotion technology controls the lancet’s movement Less side-to-side motion of the lancet means less skin damage Turn the rotatable cap for 11 penetration depth settings for different skin types The Accu-Chek Softclix lancets are precisely manufactured for precise entry Additional specifications Penetration Depth: 11 fixed-depth options, set with the rotatable cap Penetration Range: 0.8 to 2.3 mm Lancing Technology: Clixmotion Technology Weight: 21 g Alternative Site Testing: AST cap provided Needle Diameter: 0.4 mm Gauge: 28 Coating: Silicon How to use the Accu-Chek Softclix lancing device The Accu-Chek Softclix lancing device is small and easy to operate, with one-hand priming and lancing. Pull off the cap. Insert a new lancet into the lancet holder and push it in until it clicks. Press the cap on again until it clicks. Rotate the cap until the desired penetration depth is set. Press the priming button down until it clicks. Press the lancing device firmly against the side of the fingertip. Press the yellow release button. After measuring your blood glucose, pull off the cap and slide the ejector forwards to remove the lancet.

Send Message
product image
Hematology

Buy the Best Automated Hematology Analyzers – Acculab CBC 360 Neo. This Hematology Analyser Machine is Truly Automated for self-checking, background test, calibration, sampling, dilution, mixing, printing, dormancy, alarms, cleaning and maintenance. CBC 360 Neo is 3 part hematology analyzer from Accurex & is Automated for Walk-away Operations. Dual Chamber: Measurement of RBC / platelets & WBC / HGB in different chambers ensure accurate counting in a short time. The micro-aperture sizes of both the chambers are well designed to avoid error due to cell misclassification Automation for Walk-away Operation: Auto Self-check : Automatic aspiration of reagents & rinsing of tubings on startup Auto Blank : Background test is run automatically on startup Auto Print : Automatic printing of report with / without histogram Auto Sleep : Dormancy status is entered after a set period of non-operation Auto Alarms : Audio / visual alarms in case of system errors & abnormal results Auto Clean : Automatic rinsing options available to maintain the system Dual Chamber: Measurement of RBC / platelets & WBC / HGB in different chambers ensure accurate counting in a short time. The micro-aperture sizes of both the chambers are well designed to avoid error due to cell misclassification Specifications: Measurement principle: Electrical resistance for counting RBC, WBC & Platelets Colorimetric estimation of HGB at 540 nm Parameters: WBC, LY, MO, GR, LY%, MO%, GR%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR Throughput: 60 samples/hour Micro-aperture: WBC : 100 um RBC / PLT : 68 um Sample type: Whole blood or pre-diluted sample Sample volume: Whole blood (venous blood) : 10 ul Chamber: Pre-diluent (capillary blood) : 20 ul, Pre-diluent (capillary blood) : 20 ul Reagents: Dual chamber : RBC / Platelets & WBC / HGB Quality control: 4 QC options : L-J, X-B, X-R & X QC, Graphs plotted with 31 data points Data memory: Upto 100,000 (with histogram) Display: 10.4 inch LCD with 640 x 480 resolution Printer: Built-in thermal printer Interface: Support RS-232C, standard network port and USB; keyboard and mouse Operating environment: Temperature : 15˚C – 35˚C, Humidity : 85% RH Electrical specification: Voltage : AC 110V/230V 23V Frequency : 50/60 Hz, Power : 180W Fuse specification : 250V/3A Dimensions / Weight: 670 x 515 x 640 mm / 27.5 kgs Specification Acculab CBC 360 Neo – Fully Automated Hematology Analyzer Features: 3-part differentiation of WBC Automated for — self-checking, background test, calibration, sampling, dilution, mixing, printing, dormancy, alarms, cleaning and maintenance High processing speed : 60 samples/hour Multi-parameter estimation : 20 parameters categorized according to corpuscle type for easy reporting Direct command keys for Mode, Prime, Flush, Drain & Record / Print for faster operation Run / Standby indicator lights denote the analyzer status i.e. test is being run or analyser is ready to test Whole blood/ Pre-diluent indicator lights denote the sample type in use i.e. whole blood/ pre-diluent Dual sample mode with low sample volume: Whole blood (venous) mode : 10 ul; pre-diluent (capillary) mode : 20 ul Audio alarm indication for abnormal findings or system errors 4 QC methods : L-J, X-B, X-R & X QC Comprehensive QC graphs with 31 data points for each parameter Internal & external probe cleaning facility Dormancy mode available to reduce power consumption Memory : 100,000 (with histogram) Safety Information • Large 10.4 inch single screen color display of all 21 parameters and 3 histograms • Sequential arrangement of WBC, RBC & PLT parameters for convenient reporing •Easy to understand & icon-based arrangement of menu for fast and convenient testing Direction for Use • WBC Histogram: R1, R2, R3, R4 & RM indications on histogram show specific abnormalities in the histogram & the probable causes • Platelet Histogram: PM indication is given when the boundary between PLT & RBC is ill-defined thus avoiding misclassification Other Info High voltage cautery function is useful in disintegrating obstinate protein or serum clog in the tubing

Send Message

Still searching for
ilqc options?