Jaipur
+918529833535

'identification'

Items tagged with 'identification'

product image
Clinical Chemistry

Mindray HyPixel U1 endoscope camera system delivers high-definition images and enables surgeons to view organs and tissues in real color, perfectly identify .. 4K Resolution Deliver ultra-high-definition image with 3840×2160 resolution. Wide Color Gamut Restore the organs and tissues in real color, perfect identification of blood vessels, lymph nodes and nerves. 3-200mm Depth of Field Focus remains clear while switching between multiple operating scenes. 55 inch Immersive Experience The surgical image is enlarged without reducing the resolution, so that the details are no longer small, and the doctor's visual fatigue is reduced. Built-in USB Recording p42-s3-1-web p42-s3-2-web The built-in USB recording starts with one click, and the high-quality video will be saved as Full HD version as predefined. p42-s3-3-web With bookmark function, it is convenient for video record review and post-editing. Ergonomics Trolley TITAN Can support a 55 inch large screen and camera system to meet common surgical needs. The innovative structural design ensures convenient and stable moving. Cable Management The camera cup holder combined with the cable hook makes storage and management easier. 7 inch Touch Panel The important information is available at a glance. The main functions are available with only one touch of the panel, and a 10° tilt up screen is easier for observation.

Send Message
product image
Instruments

The new and improved RTR-1 uses an image processing method. During measurement, the lateral flow device is captured using a 5-mega pixel camera and the picture is analyzed using image processing algorithms for identification of either presence or absence of test line bands or test line band intensity levels. The reader converts the image into a grayscale and then classifies the intensity levels of the image in 0 to 255 grayscale range. The image processing algorithm undergoes various levels of filtering and segmentation to yield the correct intensity levels from the picture. Based on the preconfigured intensity levels, the reader classifies the band intensity and reads out the results as either positive or negative. ACCURACY: Less than 3% intra-run CV Eliminates subjective interpretation by operator FLEXIBILITY: Single mode for low volume test setting Batch mode allows for high volume test setting Result output as semi-quantitative line intensity and visual image EASE-OF-USE: Built in barcode reader provides faster test setup Touch screen interface for easy operation Lightweight (0.7kg) and portable DATA MANAGEMENT: Results presented on screen, on a printout or uploaded to reader database Storage capacity of 1,000 test results (including images) Laboratory Information System (LIS) and Wi-Fi compatible Human Machine Interface 4-inch resistive touch screen Camera 5 mega pixel CMOS camera Barcode Scanner Integrated 1 dimensional barcode scanner Printer 48 mm inbuilt thermal printer Mode Single mode and batch mode operations Port/USB Data export and software upgrade through 2 USB ports Storage Storage capacity of 1000 test results (including images) Result output “Positive or Negative” as well as quantitative test line intensity Power 12V 2A Processor ARM Cortex-A53 Platform Embedded Linux Dimension 220 mm X 170 mm X 110 mm (L x B x H) Weight 0.7 kg (Approx CATALOG # PRODUCT RTR-1 Rapid Test Reader OTHER PRODUCTS YOU MIGHT BE INTERESTED IN.. CATALOG # PRODUCT ADX-110 ELISA Reader ADX-120 Microplate Washer

Send Message
product image
Immunology Analyzer

The EUROIMMUN Analyzer I is an open system for fully automated ELISA processing of up to 7 microplates and 180 patient samples in one run. The combination of EUROIMMUN ELISAs and EUROIMMUN Analyzer I enables a quick and simple, but also a secure routine operation, owing to the automatic recognition and allocation of reagents and the import of QC data via Data Matrix codes. A further quality feature is the optionally available climate control unit, which ensures constant incubation conditions — regardless of fluctuating or excessively high laboratory temperatures. The EUROIMMUN Analyzer I is designed for medium to high sample volumes. Fully automated ELISA processing for medium to high sample volume with minimal manual input High reliability and traceability due to automatic identification of barcodes of patient samples and ready-to-use reagents Fast processing of up to 70 tests per hour and up to 7 plates and 180 samples per run Convenient operation of the software including scanning of QC certificates using a 2D-hand barcode scanner Specifications Sample types Plasma, serum, CSF and stool Patient sample capacity up to 180 samples Plate capacity up to 7 Parameter capacity per run up to 54 Shakeable incubators 4 Throughput up to 70 tests per hour Sample tubes Outer diameter 10 – 16 mm, height up to 100 mm Traceability integrated code scanner for identification of samples and reagents User interface Microsoft ® Windows ® 10 Enterprise 2019 LTSC (64 Bit) Online connection ASTM interface, bi-directional Dimensions (WxDxH) 1100 mm x 750 mm x 1000 mm Weight 130 kg

Send Message
product image
Immunology Analyzer

EUROIMMUN ANALYZER 1-2P KEY FACTS Complete automated processing of all EUROIMMUN ELISA – Autoimmune diagnostics, Infectious serology with one system. Open system with more than 800 validated EUROIMMUN parameters for autoimmune and infection diagnostics Convenient, simple and reliable operation. Up to 3 microtitre plates can be loaded and 144 samples can be run Automated barcode identification of samples and reagents and ready to use reagents Option for reloading patient samples, microtiter plates, reagents and materials. Fast processing of up to 50 tests per hour Convenient operation of the software including scanning of QC certificates using a 2D-hand barcode scanner Categories: Fully Automated Immunoassay Analyzer, Fully Automated Immunoassay Analyzer category, Fully Automated Immunoassay Analyzer instruments

Send Message
product image
Clinical Chemistry

Best Fully Automated Clinical Chemistry Analyzer – Sphera M from Accurex. This chemistry analyzer is made in Italy & provides Accurate, Precise and Rapid Testing Solution. Sphera M is a Compact, fully automated, open random-access analyzer. The Minimum reaction volume is 210 µl, Minimal < 1L/h water consumption, 80 reusable UV transmitting Bionex® plastic cuvettes, 8-step wash station. It has Removable refrigerated tray with 30 open reagent positions for 50 ml or 20 ml bottles. Multiple virtual reagent disks can be programmed. The Chemistry analyser also does Auto-wash of inner & exterior probe surface. QUALITY CONTROL & CALIBRATION QUALITY CONTROL: • Levey-Jennings plots and Westgard multi rules • Upto 3 QC levels per test • QC monitor and reports • Method statistics: Test counter, CV%, mean, graphical trend analysis CALIBRATION: • Method and reagent monitor (volumes, available tests, calibration, QC status) • Automatic pre-dilution for calibrators • Upto 8 calibrators per method • Auto recalculation of result using last calibration. UNIQUE SOFTWARE DESIGN AND ARCHITECTURE: • Software designed for touch screen use • Intuitive user interface • Continuous loading of samples and reagents • Random-access and STAT • Free choice of execution order • Extended walk-away capability • Results archive with cumulative charts • Programmable automatic start up routine • Multiple work lists INTERFACE: • Bi-directional LIS, ASTM, over ethernet port of the external PC • Positive identification of samples with internal barcode reader (optional) • Printing on any Windows 7®/8® compatible printer • Method defined washing programs SYSTEM PACKS FOR SPHERA™ Accurex has developed dedicated system packs for Sphera™. Our biochemistry reagents have been intensively evaluated and validated to achieve the highest performance in Sphera™. Accurex recommends the use of these system packs according to instructions and applications validated by Accurex. Safety Information 8-step wash station for thorough cleaning of each cuvette (Needles: 6 dispensing, 6 aspiration, 1 cleaning) • Two types of systemic and special washing solutions for removing obstinate probe residues Direction for Use QUALITY CONTROL • Levey-Jennings plots and Westgard multi rules • Upto 3 QC levels per test • QC monitor and reports • Method statistics: Test counter, CV%, mean, graphical trend analysis CALIBRATION • Method and reagent monitor (volumes, available tests, calibration, QC status) • Automatic pre-dilution for calibrators • Upto 8 calibrators per method • Auto recalculation of result using last calibration Other Info Accurex has developed dedicated system packs for Sphera™. Our biochemistry reagents have been intensively evaluated and validated to achieve the highest performance in Sphera™. Accurex recommends the use of these system packs according to instructions and applications validated by Accurex.

Send Message
product image
Rapid Test

Buy AccuTest Syphilis Rapid Card Test (50 Tests) Online from Accurex. This Syphilis test is a special test kit designed to detect Syphilis (Treponema Pallidum- IgA, IgM, IgG) antibodies in serum/plasma. Syphilis is caused by the bacterium Treponema pallidum. There different types of test like VDRL test, RPR test, FTA-ABS, etc. AccuTest Syphilis Test Kit is easy to use at home and gives you 99% accurate result in just 5 -20 minutes, with sensitivity & specificity of 99.67%. Recombinant syphilis antigen (17KDa, 15KDa, 47KDa) is immobilized in the lest line region of the device. AccuTest Syphilis Rapid Test is a special test kit designed to detect Syphilis (Treponema Pallidum- IgA, IgM, IgG) antibodies in serum/plasma. This kit is easy to use at home and gives you 99% accurate result in just 5 -20 minutes, with sensitivity and specificity of 99.67%. 1. AccuTest Syphilis is a chromatographic immunoassay kit for rapid qualitative detection of Treponemal antibodies (IgA, IgM, IgG) generated against Treponema pallidum Antigens (17KDa, 15KDa, 47KDa) in human serum or plasma with high sensitivity and specificity. 2. Results just in 5-20 minutes 3. Accu Test Syphilis exhibits sensitivity and specificity of 99.67%. Features: Based on Chromatographic Immunoassay assay for detection of Treponema pallidum antigens Sample: Human Serum or Plasma 2-3 drops of Serum/Plasma sample required for testing Fast: 1 step method, result in just 5 to 20 minutes Excellent sensitivity and specificity of 99.67% Store unused kit at 2-30C Pack size: 50 T Recombinant syphilis antigen (17KDa, 15KDa, 47KDa) is immobilized in the lest line region of the device. After the specimen is added to the specimen well in the device, it reacts with syphilis antigen coated particles in the test. The mixture migrates chromatographically along the length of the test strip and interacts with the immobilized syphilis antigen. The double antigen test format can detect IgA, IgG & IgM in specimens. If the specimen contains TP antibodies a coloured band will appear in the lest line region indicating a positive result. In the absence of TP antibodies a coloured band will not appear in the region indicating a negative result. To serve as a procedural control, a coloured band will always appear in the control line region indicating that proper volume of specimen has been added and membrane wicking has occurred. Based on Chromatographic Immunoassay assay for detection of Treponema pallidum antigens Sample: Human Serum or Plasma 2-3 drops of Serum/Plasma sample required for testing Fast: 1 step method, result in just 5 to 20 minutes Excellent sensitivity and specificity of 99.67% Store unused kit at 2-30C Pack size: 50 T Direction for Use Procedure: 1. Bring the pouch to room temperature before opening to avoid condensation of moisture on the membrane of the device. Also bring the specimen to R.T. prior to testing. 2. Label the device with patient’s identification. 3. Add 2-3 drops (approx. 30 pl) of sample into the sample well of the test device. Avoid overflowing. 4. Wait for 5 – 20 minutes and read the result. It is important that the background is clear beforg the result is read. Note: Do not read the result after 30 minutes since specimen back flow may cause false result. STORAGE, STABILITY & HANDLING 1. The kit should be stored at 2 – 30° C. Do not freeze. 2. Do not use the kit past the expiration date stated on label. 3. Take off the device from the sealed pouch just before use as the device is sensitive to humidity and heat.

Send Message
product image
Rapid Test

Buy AccuTest HBsAg Rapid Card Test (50 Tests) Online from Accurex. HBsAg means Hepatitis B surface antigen which is a protein on the surface of hepatitis B virus. It can be detected in high levels in serum during acute or chronic hepatitis B virus infection. HBsAg positive indicates that the person is infectious. The hbsag test kit is a one-step immunochromatographic assay based on the antigen capture, or Sandwich principle. HBsAg positive treatment may include Antiviral medications. AccuTest HBsAg Card Test Hepatitis BHepatitis B is a viral infection that attacks the liver and can cause both acute and chronic disease. An estimated 240 million people are chronically infected with hepatitis B (defined as hepatitis B surface antigen positive for at least 6 months). Laboratory diagnosis of hepatitis B infection focuses on the detection of the hepatitis B surface antigen HBsAg. Hepatitis B surface antigen (HBsAg) consists of lipid carbohydrate and protein elements; the protein moiety provides a marker for identification of chronic, infectious BBV infections. Hepatitis B is transmitted sexually or intravenously and has an incubation period of six months. If not diagnosed properly and in time, it can develop into acute or chronic infection, liver cirrhosis and fulminant hepatitis. This test is very useful for screening blood donors, to find out whether they are HBsAg positive before collection of blood. Principle: AccuTest HBsAg is a qualitative test based on immunochromatography sandwich principle. The test card includes a combination of monoclonal anti-body gold conjugate (colloidal gold) and polyclonal solid phase antibodies which selectively binds Hepatitis B surface antigen with high degree of sensitivity. The HBsAg test is a one-step immunochromatographic assay based on the antigen capture, or Sandwich principle. The method uses monoclonal antibodies conjugated to colloidal gold and polyclonal antibodies immobilized on a nitrocellulose strip in a thin line. The test sample is introduced into well and flows laterally through an absorbent pad where it mixes with the signal reagent. If sample contains HBsAg, the colloidal gold-antibody (mouse) conjugate binds to the antigen, forming an antigen-antibody-colloidal gold complex. The complexes then migrate through the nitrocellulose strip by capillary action, which are stopped by an immobilized antibody zone forming a purple band. The formation of the first purple band (T zone) is indicative of hepatitis positive. To serve as a procedural control, an additional line of antibody antimouse IgG has been immobilized on the card. If the test is performed correctly, this will result in the formation of purple and upon contact with the conjugate as a control line. Safety Information AccuTest HBsAg test kit is designed lor detection of Hepalitis B Surface Antigenin the specimen. As with all diagnostic tests, il is recommended to interpret all the results in line wilh clinical manifestations, other lest resulls & clinicians’s view colleclively. If the lest device is showing stagnancy in flow on chromalography, it is most likely due lo problem in the sample. In this case, relest with a fresh sample or diluted sample. Direction for Use Test Procedure: 1. Allow the test, specimen and or control to room temperature prior to the testing 2. Remove one test card from the pouch and place it on a clean flat surface 3. Using the dropper provided one drop of serum/plasma or W. blood sample (25 ul), wait for few seconds till the Whole blood absorbed by sample pad (approx. 30 second), 4. Add 2-3 drops of buffer (60 ul) into the sample well. (If needed add one more drop of assay buffer). 5. Let reaction proceed until the appearance of positive line and control line or up to 20 minutes. 6. Read results after 20 minutes, strong positive reaction may visible within 5 minutes. 7. If negative or questionable results are obtained, the HBV infection is suspected, the test should be repeated ona fresh serum specimen. Storage: AccuTest HBsAg should be stored at 4-30C. However, the card may be stored at room temperature not exceeding 30C in the original sealed pouch.

Send Message
product image
Urinalysis

Product Description: This is a continuous loading system for automatic movement, timing, measurement & evaluation of urine test strips. Product Features: High Throughput - High Memory Capacity Easy operation via touchscreen Product Application: Automated reading of Urine test strips that avoids subjective errors in visual reading Technical Specifications: System: Continuous loading Semi-automated Urine test strip analyzer Type: Reflectance photometer Measuring System: Wavelengths – 460 nm, 530 nm, 610 nm Memory: 1000 results Throughput: 400 tests /hr User interface: LCD touchscreen (800 x 480 pixel) Printer: Built-in Thermal Printer Certificates: CE Physical Dimensions: 300 x 287 x 148 mm Weight : 3.2 Kg Test Strips: DekaPHAN Laura & MicroalbuPHAN Laura Parameters: Specific Gravity, Leucocytes, Nitrite, pH, Protein, Glucose, Ketone, Urobilinogen, Bilirubin, Blood & Microalbumin, Creatinine Optical QC: Grey QC strip System Interface: Communication via RS232 & USB port Host Protocol: Uni-directional Sample Identification: Sample ID via keyboard entry, barcode reader Power source: AC 100-240V/50-60 Hz Power consumption: ≤45 W

Send Message
product image
Urinalysis

Product Description: Laura SMART is a simple, quick and compact solution for routine clinical laboratories, ambulances and para clinics. It helps in automated timing, measurement and evaluation of urine test strips. Product Features: Two measuring modes (Standard: 60 samples/h & Smart Timing:240 samples/h) Portable mode using batteries Calculation of Microalbumin & Creatinine ratio Easy operation via touchscreen Product Applications: Automated reading of Urine test strips avoiding subjective errors in visual reading System: Semi-automated Urine strip analyzer Type: Reflectance photometer Measuring System: Wavelengths – 470, 540, 650 nm Memory: 400 results Throughput: 60 tests/hr in Normal Mode & 240 testes/hr in Smart mode User interface: Color TFT LCD display Printer: Built-in Thermal Printer Certificates: CE Physical Dimensions: 230 X 127 x 110 mm Weight: 0.8 Kg Test Strips: DekaPHAN Laura & MicroalbuPHAN Laura Parameters: Specific Gravity, Leucocytes, Nitrite, pH, Protein, Glucose, Ketone, Urobilinogen, Bilirubin, Blood & Microalbumin, Creatinine Optical QC: Grey QC strip System Interface: Communication via RS232 & USB port Host Protocol: Uni-directional Sample Identification: Sample ID via keyboard entry, barcode reader Power source: AC 90-230V/50-60 Hz Power consumption: 20 W max./1 W standby

Send Message

Still searching for
identification?