Jaipur
+918529833535

'identi reagents'

Items tagged with 'identi reagents'

product image
Clinical Chemistry

Ready to use liquid stable reagents. Pack sizes cater to specific customer needs. High quality reagents manufactured to international standards. Categories: Clinical Chemistry, Reagents Description Reagents Technical Information KITS Albumin Alkaline Phosphatase AST/SGOT Bilirubin Direct Calcium CK-NAC Creatinine GGT LDL Direct Magnesium Total Protein Uric Acid ALT/SGPT Amylase Bilirubin Total Bilirubin Total & Direct Cholesterol CK-MB Glucose HDL Direct LDH-L Phosphorus Triglycerides Urea Kinetic (Rate BUN) Lipase information every single reagents has a diffrent price 1 pack single price.

Send Message
product image
Hematology

BC-6800 Today, laboratories not only need more reliable routine CBC plus 5-part diff WBC testing by way of high processing speed, but are also looking for options that extend the analyzer's output in form of Reticulocytes, Nucleated RBCs, Fluorescent Platelet counts etc. for wider clinical application and research. On the other hand, they are restricted by limited budgets. BC-6800 can help to meet all these needs just perfectly and even exceed the expectations. Additional parameters for further clinical applications IMG(#,%) parameters provide information about immature granulocyte, including promyelocytes, myelocytes and metamyelocytes. HFC*(#,%) parameters represent high fluorescent cell population, such as blasts and atypical lymphocytes. RET(#,%) extend valuable help in the differential diagnosis and/or therapeutic monitoring of anemias. IRF is parameter concerning immature reticulocytes, which can assist in early diagnosis of anemia and monitoring the bone marrow response to therapy. InR*(#,‰) are parameters regarding infected red blood cell. The red blood cells may infected by plasmodium, which can cause malaria. * means research parameters SF Cube Technology SF Cube is a pathbreaking technology for reliable blood cell analysis, including WBC differential, Reticulocytes and NRBC with efficient flagging. After reaction with proprietory reagents, the targeted blood cells undergo 3D analysis using information from scatter of laser light at two angles and fluorescence signals. The 3D scattergram builds the power to better identify and differentiate blood cell populations, especially to reveal abnormal cell population undetected by other techniques. Minimizing interference to ensure more accurate results NRBCs are counted in a dedicated channel by SF cube method, which automatically corrects total WBC count and 5-part Diff results when NRBCs are detected. The Focusing Flow-DC method minimizes the interference traditionally encountered in DC technology to produce near gaussian histograms. PLT-O result avoids the interference from microcytic and fragmented RBCs, large platelets and/or platelet clumps by fluorescent stain, and enhances the results accuracy and sensitivity. High automation to minimize the workload Throughput for 125 tests/hour, autoloader for 100 sample tubes capacity Bi-directional LIS with HL7 or ASTM communication protocol Customizable re-exam rules allow users to define their re-exam criterion according to lab’s practice

Send Message
product image
Immunology Analyzer

The EUROIMMUN Analyzer I is an open system for fully automated ELISA processing of up to 7 microplates and 180 patient samples in one run. The combination of EUROIMMUN ELISAs and EUROIMMUN Analyzer I enables a quick and simple, but also a secure routine operation, owing to the automatic recognition and allocation of reagents and the import of QC data via Data Matrix codes. A further quality feature is the optionally available climate control unit, which ensures constant incubation conditions — regardless of fluctuating or excessively high laboratory temperatures. The EUROIMMUN Analyzer I is designed for medium to high sample volumes. Fully automated ELISA processing for medium to high sample volume with minimal manual input High reliability and traceability due to automatic identification of barcodes of patient samples and ready-to-use reagents Fast processing of up to 70 tests per hour and up to 7 plates and 180 samples per run Convenient operation of the software including scanning of QC certificates using a 2D-hand barcode scanner Specifications Sample types Plasma, serum, CSF and stool Patient sample capacity up to 180 samples Plate capacity up to 7 Parameter capacity per run up to 54 Shakeable incubators 4 Throughput up to 70 tests per hour Sample tubes Outer diameter 10 – 16 mm, height up to 100 mm Traceability integrated code scanner for identification of samples and reagents User interface Microsoft ® Windows ® 10 Enterprise 2019 LTSC (64 Bit) Online connection ASTM interface, bi-directional Dimensions (WxDxH) 1100 mm x 750 mm x 1000 mm Weight 130 kg

Send Message
product image
Immunology Analyzer

EUROIMMUN ANALYZER 1-2P KEY FACTS Complete automated processing of all EUROIMMUN ELISA – Autoimmune diagnostics, Infectious serology with one system. Open system with more than 800 validated EUROIMMUN parameters for autoimmune and infection diagnostics Convenient, simple and reliable operation. Up to 3 microtitre plates can be loaded and 144 samples can be run Automated barcode identification of samples and reagents and ready to use reagents Option for reloading patient samples, microtiter plates, reagents and materials. Fast processing of up to 50 tests per hour Convenient operation of the software including scanning of QC certificates using a 2D-hand barcode scanner Categories: Fully Automated Immunoassay Analyzer, Fully Automated Immunoassay Analyzer category, Fully Automated Immunoassay Analyzer instruments

Send Message