Jaipur
+918529833535

'hz weight'

Items tagged with 'hz weight'

product image
Hematology

The BC-3600 Hematology analyzer features closed tube sampling via a single push button. A built-in large 10.4 inch color touchscreen allows maximum visibility. Hemoglobin analysis is performed using cyanide-free reagent. The analyzer processes up to 60 samples per hour and stores up to 40,000 results with histograms. The barcode reader and optional LIS connectivity enable seamless sample data transmission. Nearly all scheduled maintenance procedures are automated by touch buttons. The intuitive software enhances workflow efficiency and provides operators with a pleasant user experience. Key Features CBC plus 3-part differential, 16 parameters + 3 histograms 60 samples per hour, 1 min per CBC Closed tube sampling, minimize operational biohazard Built In diluent dispenser for predilution mode All-in-one CBC result screen display; results at a glance Touch button maintenance procedures One maintenance reagent only – probe cleaner Storage capacity of 40,000 results with histograms Uploadable QC files; ensure accuracy and time efficiency Parameters WBC, Lymph#, Mid#, Gran#, Lymph%, Mid%, Gran%, RBC, HGB, HCT,MCV, MCH, MCHC, RDW,PLT, MPV and histograms for WBC, RBC, PLT Principles Electrical impedance method for cell counting and Cyanide - free for hemoglobin Sample Volume Prediluted 20µL Whole Blood 21µL Carryover WBC/RBC/HGB≤0.5% PLT≤1.0% Connectivity 4 USB ports (for external printer, software upgrade, barcode reader,keyboard and mouse), LAN port (1), RS232 (1) Printout Thermal recorder, 50mm width paper, various printout formats, external printer (optional) Product Specification Brand Mindray Differential Type 3-Part Model Name/Number BC 3600 Display Type Large color touch screen Resolution 800x600 Usage/Application Hospital Throughput 60 samples per hour Power Supply AC 100-240V,50/60 +-1Hz Weight 62 lbs Dimension 16 in(W) x 18 in(H) x 18 in(D) Humidity 30%-85% Temperature 15 ~30 Deg C Minimum Order Quantity 1

Send Message
product image
Digital Spectrophotometer

Product Details: Wavelength Range 340-950 nm Mobility Portable Brand Spectronic Model No / Item Code Spectronic-20D Photometric Range 0 to 100%T 0 to 1.95 Abs 0 to 1999 Conc Display Digital Weight 8.2 kg (18 lbs) Power Requirements 100/115 V, 50/60 Hz; 220/240 V We are the Manufacturers of Spectrophotometer. Product Specifications Spectronic 20 Part Number 333182000 Series Spectronic 20D Part Number 333183000 Series Spectral Slit Width 20 nm 20 nm Wavelength Range 340 to 950 nm 340 to 950 nm Wavelength Accuracy /- 2.5 nm near 525 nm /- 2.5 nm near 525 nm Display Meter LED 5 1/2" mirrored scale, linear %T, Abs, Conc, Concentration Factor %T, non-linear Abs Wavelength Photometric Range 0 to 100%T 0 to 100%T 0 to 2 A 0 to 1.95 Abs 0 to 1999 Conc 0.1 to 1000 Concentration Factor Photometric Accuracy /- 2%T /- 2%T Photometric Noise /- 0.5%T /- 0.5%T Photometric Drift 1.0%T/Hour 1.0%T/Hour Accessory Output 1.0 VDC nominal at 100%T 1.0 VDC nominal at 100%T RS-232C Serial I/O Port Stray Radiant Energy <0.5%T over entire wavelength range* <0.5%T over entire wavelength range* ,

Send Message
product image
Digital Spectrophotometer

Detector Silicon Photodiode Path Length 10 mm Range 340 to 960 nm Resolution 0.1% T,0.001 Abs Light Source 6V, 1 Amp, Tungsten Halogne lamp Grating 600 lines/cm Specifications: Range 340 to 960 nm Resolution 0.1% T,0.001 Abs Output % T: 0 to 100%, Abs:0 to 1.999 Conc: 0 to 1999 Detector Silicon Photodiode Light Source 6V, 1 Amp, Tungsten Halogne lamp Grating 600 lines/cm Path length 10 mm Spectral Bandwidth 10 nm Wavelength Resolution 1 nm on Display 2% digit LED Wavelength Accuracy 1 nm Repeatability ±1 nm Read out 3½ digit LED, 1 nm step Operating Temp 5 to 45°C Path length 10 & 50 mm in Model LT-38 Additional Information: Item Code: UV-Mini-1240 Yes! I am interested Spectrophotometer REQUEST CALLBACK Spectrophotometer Ask for Price Product Price :Get Latest Price Product Details: Wavelength Range 340-950 nm Mobility Portable Brand Spectronic Model No / Item Code Spectronic-20D Photometric Range 0 to 100%T 0 to 1.95 Abs 0 to 1999 Conc Display Digital Weight 8.2 kg (18 lbs) Power Requirements 100/115 V, 50/60 Hz; 220/240 V We are the Manufacturers of Spectrophotometer. Product Specifications Spectronic 20 Part Number 333182000 Series Spectronic 20D Part Number 333183000 Series Spectral Slit Width 20 nm 20 nm Wavelength Range 340 to 950 nm 340 to 950 nm Wavelength Accuracy /- 2.5 nm near 525 nm /- 2.5 nm near 525 nm Display Meter LED 5 1/2" mirrored scale, linear %T, Abs, Conc, Concentration Factor %T, non-linear Abs Wavelength Photometric Range 0 to 100%T 0 to 100%T 0 to 2 A 0 to 1.95 Abs 0 to 1999 Conc 0.1 to 1000 Concentration Factor Photometric Accuracy /- 2%T /- 2%T Photometric Noise /- 0.5%T /- 0.5%T Photometric Drift 1.0%T/Hour 1.0%T/Hour Accessory Output 1.0 VDC nominal at 100%T 1.0 VDC nominal at 100%T RS-232C Serial I/O Port Stray Radiant Energy <0.5%T over entire wavelength range*

Send Message
product image
Urinalysis Analyzer

The AUTION ELEVEN AE-4020 is intended for the qualitative and/or semi-quantitative measurement of several physiological markers in urine: Glucose, Protein, Bilirubin, pH, Blood, Urobilinogen, Ketones, Nitrite, Leukocytes, Creatinine, Albumin, Specific Gravity, P/C (Ratio of Protein to Creatinine) and A/C (Ratio of Albumin to Creatinine). These measurements are used for screening of kidney disease, liver disease, diabetes mellitus and urinary tract infection in general screening populations. Compact Design: 210(W) x 328(D) x 164(H) mm / Approx. 3.6 kg Processing speed: 514 samples per hour (maximum processing mode: 7 second interval) Auto-start function: Measurement starts automatically when a strip is set on the tray. Test strip can be placed either from the left or the right side. Maximum 11 parameters and color tone can be measured simultaneously by special test strips designed and made by ARKRAY. *Some products including test strips may not be available in all countries. Please check with your local Arkray representative or distributor about product availability in your area. Sample Urine Test Strip / Reagent pack AUTION Sticks / Uriflet S / AUTION SCREEN Measurement item GLU, KET, BIL, NIT, PRO, URO, pH, BLD, LEU, ALB, CRE, Specific Gravity, color tone Measurement range Test strip: As Rank table Color tone: As Color tone classification chart Measurement method Test strip method Dual-wavelength reflection photometric method (single wavelength for BLD) Measurement wavelength 4-wavelength LED (430, 565, 635, and 760 nm) Test strip reaction time 60 seconds Processing speed 514 samples per hour (maximum processing mode: 7-second interval) Display Custom LC display (icons are used) Built-in printer 32-digit thermal printer (58 mm width) External output Conforms to RS-232C standard (serial) Option: Ethernet Memory capacity 520 measurement results Temperature correction Auto-correction by the internal temperature sensor (between 10 to 30 °C) S. G. correction Auto-correction by pH values Chromaturia correction Auto-correction by the color tone correction section on test strips Operating environment Temperature: 10 to 30 °C; Humidity: 20 to 80% R.H. (non-condensing) Measurement environment Temperature: 10 to 30°C; Humidity: 30 to 60% R.H. (non-condensing) *Temperature correction function used DC power requirements(To instrument) 12 Vdc 3 A AC power requirements(To AC adapter) 100-240 Vac 50-60 HZ ,1200 mA Voltage fluctuation allowance is ±10% Power consumption Max. 45 VA Dimensions 210 (width) × 328 (depth) × 164 (height) mm Weight Approx. 3.6 kg

Send Message
product image
Urinalysis Analyzer

High Performance "Full Automated System" Color Touch Panel for good usability 7 inch WVGA color touchscreen with high operability displays measurement results, instrument conditions and operating instructions. "Sample delivery system" enables micro volume samples to be measured As the sample is drawn through the nozzle and delivered correctly and quantitatively to each pad of the strip, the micro volume samples (minimum 1mL) can be measured easily. No cross contaminations are found on the reagent portions despite high sample volume. Sample Urine Test items Glu, Pro, Bil, Uro, Ket, pH, Nit, Bld, Leu, S.G., Alb, Cre(Alb/Cre ratio, Pro/Cre ratio can be calculated), turbidity and color tone Wavelength 5 LED wavelengths (430, 500, 565, 635, 760nm) Measurement principle Test strip :Dual-wavelength reflectance method (One-wavelength for Bld) Specific gravity :Reflection refractometryColor hue :Light-transmission measurementTurbidity :Light-scattering measurement method Test strip AUTION Sticks (10EA & 10PA) , Uriflet S 11UA Reaction time Approximately 60 seconds Throughput 225 samples per hour Strip storage Maximum 400 strips (200 strips x 2 feeder boxes) Required sample volume Normal, STAT measurement: Minimum 2 mL Small volume measurement: Minimum 1 mL Sample consumption Normal, STAT measurement: Maximum 0.90 mL Small volume measurement: Maximum 0.45 mL Sample container Sample tubes (length: 95 - 110 mm, diameter: ø14.0 - 15.8 mm) Maximum sample load 100 samples (Circulation) Data memory Normal, STAT, small volume measurement: 2500 tests Control measurement: 200 tests Check measurement: 50 tests Trouble list: 100 tests Display Large color liquid crystal display (800 × 480 dots) Built-in printer 58-mm width printer paper (24 digits) External output 1 port (Replaceable with the optional Ethernet terminal) Communication method RS-232C compliant (Switchable between one-way and two-way) Measurement environment Temperature: 10 - 30°C; Humidity: 30 - 60% RH (No condensation) Power requirements 100 - 240 V AC (Maximum power line fluctuation of ±10%), 50/60 Hz Power consumption 150VA (Maximum) Dimensions 530 (W) × 530 (D) × 550 (H) mm (including the sampler) Weight Main body: Approximately 36 kg Sampler: Approximately 4 kg

Send Message
product image
Clinical Chemistry

Autochem Ingeniious is a semi automated clinical chemistry analyser & has been designed to meet the demands of the research as well as laboratory staff. Compact ergonomic design which is ideal for use in small-to-medium-sized laboratory. In-built Peltier regulated incubation compartment Integrated Coagulation Testing Mode Single & profile wise testing facility Flexible calibration modes Direct access key to run tests Enhanced Patient Data Storage & Retrieval Daily & monthlty QC program Wash & Aspiration function can be controlled using External Keyboard (PS/2 keyboard) roduct Specification Automation Semi Automatic Brand ARKRAY Assays Clinical Chemistry Power Supply Input Voltage : 90-260 VAC, 50/60 Hz Reaction Cuvette Flow Cell Weight <10 kg Power 100 Watts Max Country of Origin Made in India

Send Message
product image
Laboratory Testing Analyzer

The ADAMS A1c, HA-8180T is a fully automated Glycohemoglobin analyzer based on HPLC (High Performance Liquid Chromatography) and is highly effective for ß-thalassemia testing. Measurement speed: 3.5 minutes/test Measurement Item as below HbA2 HbF HbA1c (Stable HbA1c, S-A1c), HbS, HbC, HbE and HbD can be detected. Column design with no more pre-filter change. Color LCD with reagent level, graphs on screen. Samples Whole blood or hemolysis sample Measurement items HbA1c(Stable HbA1c, S-A1c), HbA2 and HbF (HbS, HbC, HbE and HbD can be detected.) Reagents *1 ELUENT 80A, ELUENT 80B, ELUENT 80CT and HEMOLYSIS WASHING SOLUTION 80H Column *2 COLUMN UNIT 80T Measurement principle Reversed-phase cation exchange chromatography Detection method Dual-wavelength colorimetry (wavelengths measured: 420nm/500nm) Resolution 0.1% Ratio, 1 mmol/mol Measurement range *3 HbA1c : 3-20%, 9-195 mmol/mol HbA2 : 2-10% HbF : 0-100% Guaranteed measurement range *4 HbA1c : 4.2-12.9%, 22-117 mmol/mol HbA2 : 2.4-6.3% HbF : 0.1-14.3% Processing speed 210 seconds per sample Sample consumption Approx.14μL(whole blood) Sample container Blood collection tube (12.3 to 15mm diameter) × ( 75 to 100mm length) Sample cup(500μL) Sampling method Cap-Piercing Rack type ARKRAY racks Number of measurement samples One-way transportation (factory set) : Maximum 50 samples Loop transportation : Maximum 100 samples Column temperature Approx. 39℃ Display Color graphic LCD with backlight Memory capacity 500 test results ( including calibration results ) Built-in Printer Termal printer, 58mm thermal paper External output Serial 1 port (Can be optionally used as an Ethernet port.) Measurement conditions Temperature : 15-30℃ Humidity : 20-80% relative humidity (non-condensing ) Required sample volume Blood collection tube : Minimum 10mm away from the bottom Sample cup : 400μL or more Warm-up time Maximum 30 min. Dimensions 530(W)×530(D)×530(H)mm (Not including the hemolysis washing solution bottle) Weight Analyzer: Approx. 39kg, Sampler: Approx. 4kg Power supply AC100V-240V ±10% 50/60Hz Power consumption Max. 300 VA *1, *2 Reagents and column are sold separately from HA-8180T analyzer. *3 Error-free measurement ranges. *4 Guaranteed ranges for obtaining results equivalent to those from HA-8160 TP mode measurement. ※Design and specications may be changed without prior notice

Send Message
product image
Laboratory Testing Analyzer

The ADAMS A1c, HA-8180 is a fully automated Glycohemoglobin (HbA1c) analyzer based on HPLC (High Performance Liquid Chromatography). HbA1c is a good parameter for long-term blood glucose monitoring in patients suffering from diabetes mellitus. Measurement Speed: 48 sec/test for Fast Mode and 90 sec/test for Variant mode. Measurement items are as follows. HA-8180V, Fast Mode HbA1c (Stable HbA1c, S-A1c) and HbF HA-8180V, Variant Mode  HbA1c (Stable HbA1c, S-A1c) and HbF HbS and HbC separation and HbE and HbD detection can be performed. ・Column design with no more pre-filter change ・Economical - improved aluminium reagents for more efficient reagent supply ・Color LCD with reagent level, graphs on screen Specifications Configuration Main body, sampler (with sample tube spinning unit) and accessories Measurement objects Whole blood or hemolysis sample Column COLUMN UNIT 80 Reagents ELUENT 80A, ELUENT 80B, ELUENT 80CV and HEMOLYSIS WASHING SOLUTION 80H Measurement items Fast Mode HbA1c (Stable HbA1c, S-A1c) and HbF Variant Mode HbA1c (Stable HbA1c, S-A1c) and HbF (HbS and HbC separation and HbE and HbD detection can be performed) Measurement ranges *1 HbA1C: 3 - 20%, 9 - 195 mmol/mol HbF: 0 - 100% Guaranteed measurement ranges *2 HbA1C: 4 - 16%, 20 - 151 mmol/mol HbF: 0.3 - 5% Measurement principle Reversed-phase cation exchange chromatography Measurement wavelength 420 nm / 500 nm (Dual-wavelength colorimetry) Sample supply Sampler Resolution 0.1 % Ratio, 1 mmol / mol Processing speed Variant mode : 90 seconds / test Fast mode : 48 seconds / test Sample consumption Approximately 14 μL (Whole blood) Required sample volume Sample tube : Minimum 10 mm away from the bottom Sample cup : 400 μL or more Sample container Sample tube : (12.3/15 mm diameter) × (75 to 100 mm length) Sample cup: 500 μL Compatible rack type ARKRAY racks Number of measurement samples One-way transportation (factory-set) : Maximum 50 samples Loop transportation : Maximum 100 samples Column temperature Approximately 40°C Warm-up time Maximum 30 minutes Display Large color LCD with backlight Printer For use with 58-mm width thermal printer paper Memory capacity 900 measurement results (including calibration results) External output Serial 1 port (Can be optionally used as an Ethernet port.) Communication system RS-232C compliant (Switchable between one-way and two-way communications.) Transmission speed RS-232C : Selectable from 300, 600, 1200, 2400, 4800, 9600 and 19200 bps Ethernet: 10BASE-T Dimensions 530 (W) × 530 (D) × 530 (H) mm (Not including the hemolysis washing solution bottle) Weight Main body: Approximately 39 kg, Sampler: Approximately 4 kg Power requirements 100 - 240 V AC ± 10 %, 50 / 60 Hz Power input Maximum 300 VA *1 Error-free measurement ranges *2 Guaranteed ranges for obtaining results equivalent to those from HA-8160 VP mode measurement

Send Message
product image
Immunology Analyzer

Fully Automated Chemiluminescence Immunoassay Analyzer Introducing iFlash 1200, a chemiluminescence immunoassay analyzer that offers fully automated immunoassay analysis using Magnetic particle-based Direct Chemiluminescence technology. With a high throughput of up to 120 tests per hour and a first result available in just 13 minutes, iFlash 1200 is one of the fastest and most efficient immunoassay analyzers available on the market. The instrument features continuous STAT sample loading capacity with 16 sample positions, continuous reagents loading capacity with 15 reagent positions, and continuous loading of reaction vessels with a capacity of 500 cuvettes. Additionally, iFlash 1200 uses Acridinium Ester Labeled Direct Chemiluminescence for highly accurate and reliable results, and comes with ready-to-use reagents in convenient 2 x 50 tests pack size for simplified testing. Overall, iFlash 1200 is an innovative and versatile immunoassay analyzer that is perfect for laboratories that require high throughput and rapid turnaround times. iFlash 1200 chemiluminescence immunoassay analyzer Key Features: 1.Continuous loading of reagents with convenient pack size of 2 x 50 tests 2.Continous loading of 500 reaction cuvettes for longer walkaway time 3. 4 step magnetic separation for achieving high precision and quality results 4.Non contact vortex mixer-Highly Efficient technology to prevent carryover & cross contamination Additional information General Information Throughput : upto 120 tests/hour Time to First Results :13 minutes Detection Principle Magnetic particle Based Direct Chemiluminescence Chemiluminescence Label :Acridinium Ester Sample System Sample Position :16 sample position Types of Sample tube :Microcup & blood collecting tubes Sample Volume :5~150μL Reagent System Reagent Position :15 reagent positions with onboard refrigeration Reagent Carousel Temp :2-8 °C Reagent Detection :Reagent Level Tracking Reagent Pack : 2 x 50 tests Reagent Carousel Incubation Capacity :48 reaction vessels Incubation Temperature :37°C+-0.3°C Mixing System :Non-Contact Vortex Mixer Operating Conditions Power Supply :100~240V, 50/60HZ Power Consumption :600VA Temperature :10~30°C Weight :120 Kg Reagents iFlash 1200 reagents iFlash 1200 reagents Pack size 2 x 50 Tests 28 days On board reagent stability 28 days Calibration stability Built in Calibrators for all Parameters

Send Message

Still searching for
hz weight?