Jaipur
+918529833535

'human based serum'

Items tagged with 'human based serum'

product image
immunoassayReagents

INTENDED USE The Finecare™ SAA Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA System for quantitative determination of serum amyloid A (SAA) in human whole blood, serum or plasma. This test is used as an aid to assist in the diagnosis of infection and inflammation. STORAGE AND STABILITY 1. Store the test kit at 4℃~30℃ up to the expiration date printed on package. 2. If removed from refrigerator, allow the test kit for 30 minutes to return to room temperature before testing. 3. Do not remove the Test Cartridge from the pouch until use. The Test Cartridge should be used within 1 hour once opened.

Send Message
product image

Intended Use The 4th Generation HCV TRI-DOT is a rapid, visual, sensitive and qualitative in vitro diagnostic test for the detection of (IgM,IgG & IgA) antibodies to Hepatitis C virus in human serum or plasma. It has been developed and designed with increased sensitivity for core and NS3 antibodies using a unique combination of modified HCV antigen. Salient Features Based on “Flow Through Technology”, which is similar to Elisa technology because of involvement of washing steps at various levels to enhance the specificity. Use of highly purified HCV antigens for Core, NS3, NS4, NS5 immobilized on the device. Detection of all the subtypes of HCV. Results within 3 minutes. In built quality control dot which validates the test. 100% Sensitivity & 98.9% Specificity as per WHO evaluation. Shelf life : 24 months at 2-8°C

Send Message
product image
Rapid Test

Intended Use Advantage Dengue NS1 Ag card is a rapid solid phase Immuno-chromatographic test for the qualitative detection of Dengue NS1 Antigen in Human serum /Plasma.This test is for in vitro diagnostic use only and is intended as an aid in the earlier diagnosis of Dengue Infection. Salient Features Rapid test based on lateral flow technique. Detection of Dengue in the seronegative stage i.e. from Day 1 of fever. Detection of all the 4 Dengue serotypes (DEN-1, DEN-2, DEN-3 and DEN-4). Results with in 20 minutes Longer shelf life : 30 months at 2-30°C. Convenient pack size : 25 tests Sensitivity-96% and Specificity- 98%

Send Message
product image
Rapid Test

Intended Use Dengue NS1 Antigen FP is a rapid solid phase immuno- chromatographic test for the qualitative detection of Dengue NS1 Antigen in human Whole Blood/ Serum/ Plasma. This test is for in vitro diagnostic use only and is intended as an aid in the earlier diagnosis of dengue infection. Salient Features Rapid ,visual test for the qualitative detection of Dengue NS1 Antigen in whole blood/serum/Plasma. Sample can be taken from Finger prick and sample required is 4µl. Based on Sandwich principle. Detection of Dengue in Seronegative stage i.e From Day 1 of fever. Detection of all 4 serotypes of dengue virus. Reliable diagnosis of both primary and secondary infection. 100% Sensitivity & 99.96 % Specificity. Shelf life: 24 month at 2-30 °C Convenient pack Size: 10 Test. Evaluated By Referral Medical college / Hospitals /Research institutes / Labs.

Send Message
product image
Rapid Test

ntended Use The 4th Generation DIAGNOS HCV BI-DOT is a visual, rapid, sensitive and qualitative in vitro diagnostic test for the detection of (IgM,IgG & IgA) antibodies to Hepatitis C Virus in human serum or plasma. The 4th Generation DIAGNOS HCV BI-DOT has been developed and designed with increased sensitivity for core and NS3 antibodies using a unique combination of modified HCV antigens. Salient Features Rapid ,visual 4th generation test. Based on Flow Through Technology. Use of unique combination of Core, NS3, NS4, NS5 antigen. Detects all the subtypes of HCV. Result with in 3 min. Shelf life : 24 months at 2-8°C. Sensitivity- 100 %. Specificity- 99.8 %.

Send Message
product image
Rapid Test

Intended Use The HIV TRI-DOT test is a visual, rapid, sensitive and accurate immunoassay for the differential detection of HIV-1 & HIV-2 antibodies (IgG,IgM & IgA) in human serum or plasma using HIV-1 & HIV-2 Antigens immobilized on an immunofiltration membrane. The test is a screening test for Anti HIV-1 and HIV-2 and is for in vitro diagnostic use only. Salient Features Rapid visual test ,based on Flow Through Technology. Differential detection of HIV-1 & HIV-2. Detection of group ‘O’ & subtype ‘C’. Use of envelop antigens gp41& C terminus of gp120 for HIV-1 & gp36 for HIV-2. 100% sensitivity & 100% specificity as per WHO Evaluation. Shelf life 24 months at 2-8°C Available in convenient pack sizes- 50 Tests and 100 Tests. Results within 3 minutes. No instrument required. In built quality control dot.

Send Message
product image
Rapid Test

Intended Use The 4th Generation HIV TRI-DOT + Ag test is a visual, rapid, sensitive and accurate immunoassay for the differential detection of HIV-1 p24 antigen and HIV-1 & HIV-2 antibodies (IgM,IgG & IgA) in Human Serum or Plasma. The test is a screening test for p24 antigen (HIV-1), anti-HIV-1 & anti-HIV-2 and is for in vitro diagnostic use only. It is intended for screening of blood donors or other individuals at risk for HIV-1 & HIV-2 infection and for clinical diagnostic testing. Salient Features Rapid visual test ,based on enzyme immuno assay & Flow Through Technology. Rapid test for simultaneous and differential detection of p24 Antigen & antibodies for HIV on the same device. Ideal for Blood screening: detects sero-negative HIV Cases. Use of gp-41, C terminus of gp120 for HIV-1 antibodies & gp-36 for HIV -2 antibodies. Detection of Group ‘0’ & subtype ‘C’ of HIV-1, which is most prevalent in India. Unique washing steps for clear Interpretation of Results. Evaluated by National Institute of Biologicals- 100 % Sensitivity & 100 % Specificity. Long Shelf life: 15 months at 2-8° C.

Send Message
product image
Rapid Test

Intended Use The Diagnos HIV BI-DOT Test is a visual, rapid, sensitive and accurate immunoassay for the detection of HIV-1 & HIV-2 antibodies (IgM,IgG & IgA) in human serum or plasma using HIV-1 & HIV-2 Antigens immobilized on an immunofiltration membrane. The test is a screening test for Anti HIV-1 and HIV-2 and is for in vitro diagnostic use only. Salient Features Rapid visual test ,based on Flow Through Technology. Detection of group ‘O’ & subtype ‘C’ strain of HIV-1 prevalent in Asian subcontinent. Use of Envelope antigen; gp41& C terminus of gp120 for HIV-1 & gp36 for HIV-2. Shelf life 24 Months at 2-8°C. Results within 3 minutes. No instrument required. In built quality control dot.

Send Message

Still searching for
human based serum?