Jaipur
+918529833535

'heparin'

Items tagged with 'heparin'

product image
Biochemistry Analyzer

Overview A fully automated POC Auto Dry Biochemistry Analyzer called Mispa Chem Dx, With Just 3 to 4 drops (100ul) of whole blood to test up to 19 General and Special chemistry tests in less than 12 minutes. Mispa Chem Dx works on absorption spectroscopy where a change in absorbance is detected by an absorption spectrum and an algorithm is used to calculate the end concentration of the sample in the reagent dry disc. The reagent disc consists of lyophilized reagent beads, diluent, and calibration details in the QR code. The reagent disc contains an intelligent internal quality control system IQC which continuously monitors the disc function to ensure reaction stability and optimal disc performance, IQC is the engine that drives the Mispa Chem Dx accurately and precisely Low Sample Consumption Easy to Use Maintenance Free Accurate Result Disposable reagent disc Sample volume: 100µl Testing time: 12 minutes / sample Temperature: 37°C ± 0.3°C Resolution: 0.001Abs Absorbance: 0-3.0Abs Sample type: Heparinized whole blood, serum, plasma (heparin) QC&Calibration: IQC (Intelligent Quality Control/Calibration) Work condition: Temperature:10-30°C Humidity: 30%-70% Testing method: End point, kinetic, fixed time, turbidmetry etc Light source: 12V/20W, Halogen tungsten lamp with life span over 2500 hours Power supply: AC 100V-240V, 50-60Hz Display: Android 7.0 inch 800*480, multi-point capacitive touch screen Storage: 500,000 results Printer: Built-in thermal printer Interface: 4 USB ports, 1 LAN port Dimension: 315*375*475mm. 4.2kg(N.W.), 7kg(G.W.)

Send Message
product image
Rapid Test

The OnSite Chikungunya IgM Combo Rapid Test is a lateral flow chromatographic immunoassay for the qualitative detection of IgM anti-chikungunya (CHIK) virus in human serum, plasma or whole blood. Uses serum, plasma or whole blood specimen Utilizes recombinant antigen derived from the CHIK structure protein IgM immunoassay is the most practical lab method Distinguish from dengue infection which presents with similar symptoms Clinical performance: Sensitivity: 90.4% Specificity: 98.0% comparing to a commercial ELISA Cross-Reactivity: no cross-reactivity found on 10-40 specimens from the 14 disease states and special conditions, such as dengue, Zika, malaria, HIV, TB, HAV, pregnant woman and others No interference with some common substances, such as Acetominophen (20 mg/dL), Heparin (3000 U/L), Ascorbic acid (20 mg/dL), Human IgG (1000 mg/dL), Bilirubin (20 mg/dL), Glucose (55 mmol/L), Creatinine (442 μmol/L), Salicylic acid (4.34 mmol/L), EDTA (3.4 μmol/L), Sodium citrate (3.8%) Individually sealed foil pouches containing: One cassette device One desiccant Capillary tubes (5 μL) Sample diluent (REF SB-R0066, 5 mL/bottle) One package insert (instruction for use) CTK Products at a Glance Inserts U.S. CDC Chikungunya Virus Homepage: (Transmission, Prevention, etc.) WHO: Chikungunya Virus Fact Sheets

Send Message
product image
Rapid Test

The OnSite Leptospira IgG/IgM Combo Rapid Test is a lateral flow chromatographic immunoassay that can be performed within 15-20 minutes by minimally skilled personnel, and without the use of laboratory equipment. This test is intended to be used for the simultaneous detection and differentiation of IgG and IgM antibodies to Leptospira interrogans (L. interrogans) in human serum, plasma or whole blood. It is intended to be used as a screening test by professionals, and provides a preliminary test result to aid in the diagnosis of infection with L. interrogans. Any interpretation or use of this test result must also rely on other clinical findings as well as on the professional judgment of health care providers. Recommended for use: Any person presenting with clinical signs or symptoms consistent with acute infection with interrogans including: high fever, headache, chills, muscle aches, vomiting, jaundice, red eyes, abdominal pain, diarrhea, skin rash After exposure to a known contaminated source Accuracy: 100% specificity and 100% sensitivity in comparison with a reference rapid test on the market Cross Reactivity: No false positive results were observed on specimens from TP, HIV, Dengue, TB, Typhoid Ab , HBsAg, HCV Ab, HEV Ab, H.P Ab, HAV, HCG, RF, ANA, HAMA Interference: No interference were seen with substances: Salicylic acid: 4.34 mmol/L; Glucose: 55 mmol/L; Sodium citrate: 3.8 %; Heparin: 3,000 U/L; Creatinine: 442 μmol/L; Bilirubin: 20 mg/dL; EDTA: 3.4 μmol/L; Hemoglobin: 2g/L; Human IgG: 1000 mg/dL; AlbuminL 60 g/L Shelf life: 24 month Individually sealed foil pouches containing: One cassette device One desiccant 5 μL capillary tubes Sample diluent (REF SB-R0101, 5 mL/bottle) One package insert (instruction for use) CTK Products at a Glance Inserts U.S. CDC Leptospira Homepage: About Leptospira WHO: Leptospirosis Fact Sheets

Send Message
product image
Rapid Test

The OnSite Duo HSV-1/2 IgG/IgM Rapid Test is a lateral flow chromatographic immunoassay for qualitative detection and differentiation of antibodies (IgG and IgM) to herpes simplex virus 1 (HSV-1) and herpes simplex virus 2 (HSV-2) in human serum, plasma or whole blood. This test can be performed in 10 minutes by minimally skilled personnel without the use of laboratory equipment. This test is intended to be used by professionals as a screening test and provides a preliminary test result to aid in the diagnosis of infection with HSV-1 and/or HSV-2. The OnSite Duo HSV-1/2 IgG/IgM Rapid Test uses HSV-1 glycoprotein G1 and HSV-2 glycoprotein G2 for the specific detection and differentiation of IgG and IgM antibodies to HSV-1 and HSV-2 in serum, plasma and whole blood. An HSV-1 and/or HSV-2 IgM positive result indicates an active infection, which may be primary or recurrent. An HSV-1 and/or HSV-2 IgG positive result indicates a recent or past infection. However, a negative test result does not preclude the possibility of infection with HSV-1 and/or HSV-2. Any interpretation or use of this preliminary test result must also rely on other clinical findings as well as on the professional judgment of health care providers. Alternative test method(s) should be considered to confirm the test result obtained by this device. Clinical accuracy: 90.6% sensitivity and 91.4% specificity for anti-HSV-1 IgG detection 93.8% sensitivity and 96.0% specificity for anti-HSV-2 IgG detection 85.0% overall agreement for anti-HSV-1 IgM detection comparing to commercial ELISA 100% overall agreement for anti-HSV-2 IgM detection comparing to BBI Panel (PTH202) Positive rate on random clinical specimens:8% for IgG anti-HSV-1 and 4.9% for IgM anti-HSV-1 (n=10,000); 4.6% for anti-HSV-2 IgG and 1.7% for anti-HSV-2 IgM Cross reactivity: no cross reactivity with the following disease states or special conditions, respectively: palladium, H. pylori, Dengue, Malaria, Typhoid, Toxoplasma, Rubella, CMV, hCG, TB, HAV, HBV, HCV, HEV, HIV, ANA, HAMA, RF (up to 1,000 IU/mL) Interference: No interference was seen with Albumin 60 g/L , Hemoglobin 2 g/L, Bilirubin 20 mg/dL, Heparin 3,000 U/L, Creatinine 442 µmol/L, Salicylic acid 4.24 mmol/L, EDTA 3.4 µmol/L, Sodium citrate 8%, Glucose 55 mmol/L Shelf life: 24 months Individually sealed foil pouches containing: One cassette device One desiccant Capillary tubes (10 µL) Sample diluent (REF SB-R0203, 5 mL/bottle) Package insert (instruction for use) Individually sealed foil pouches containing: One cassette device One desiccant Capillary tubes (10 µL) Sample diluent (REF SB-R0203, 5 mL/bottle) Package insert (instruction for use)

Send Message

Still searching for
heparin?