Jaipur
+918529833535

'healthcare professionals'

Items tagged with 'healthcare professionals'

product image
Rapid Test

The OnSite Troponin I Combo Rapid Test is a lateral flow chromatographic immunoassay for the qualitative detection of cardiac Troponin I (cTnI) in human serum, plasma or whole blood at a level equal to or higher than 1 ng/mL. It can be performed within 15 minutes by minimally skilled personnel, and without the use of laboratory equipment. The OnSite Troponin I Combo Rapid Test is intended to be used by healthcare professionals as an aid in the diagnosis of acute myocardial infarction (AMI). Any use or interpretation of this preliminary test result must also rely on patient’s symptoms and the professional judgment of a physician. A more precise test method such as an instrument method must be used to confirm the test result obtained by this device. Normally the level of cTnI in the blood is very low. cTnI is released into the blood stream in forms of free cTnI and cTnI-C-T complex at 4-6 hours after myocardial cell damage. The elevated level of cTnI could be as high as 50 ng/mL during 60-80 hours after AMI and remains detectable for up to 10-14 days post AMI. Therefore, circulating cTnI is a specific and sensitive marker for AMI. Clinical performance: Relative Sensitivity: 95.8% (95% CI: 91.5-97.9%) compared to a reference CLIA Relative Specificity: 99.7% (95% CI: 98.8-99.9%) Analytical sensitivity: The detection limit of cTnI is 1.0 ng/mL or greater in serum, plasma or whole blood specimen Cross-reactivity: No cross reactivity with 10 µg/mL skeletal muscle TnI, 2,000 ng/mL cardiac muscle TnT, 20 µg/mL cardiac muscle Myosin Dose hook effect: No hook effect was observed for cTnI at concentrations up to 3,521 µg/mL Interference: No interference was seen with 20 mg/dl Acetaminophen, 20 mg/dl Acetylsalicylic acid, 10.5 g/dl Albumin, 20 mg/dl Ascorbic acid, 1,000 mg/dl Bilirubin, 20 mg/dl Caffeine, 800 mg/dl Cholesterol, 200 mg/dl Creatinine, 20 mg/dl Gentistic acid, 1,000 mg/dl Hemoglobin, 600 mg/dl Oxilic acid, 1,600 mg/dl Triglycerides Shelf life: 24 months Individually sealed foil pouches containing: One cassette device One desiccant Plastic droppers Sample diluent (REF SB-R3002, 5 mL/bottle) One package insert (instruction for use) CTK Products at a Glance Insert MedlinePlus: Troponin Test Poster

Send Message
product image
Rapid Test

The OnSite HBV-5 Rapid Test is a lateral flow chromatographic immunoassay for the qualitative detection of hepatitis B surface antigen (HBsAg), hepatitis B surface antibody (HBsAb), hepatitis B e-antigen (HBeAg), hepatitis B e-antibody (HBeAb), and hepatitis B core antibody (HBcAb) in human serum or plasma. It is intended to be used by healthcare professionals to aid in the diagnosis of infection with hepatitis B virus (HBV). Any use or interpretation of this preliminary test result must also rely on other clinical findings and the professional judgment of healthcare providers. Alternative test method(s) should be considered to confirm the test results obtained by this device. Panel format cassette to conveniently test for five targets at once Utilize all markers to help distinguish between acute and chronic infections Result in 15 minutes Individually sealed foil pouches containing: One cassette device One desiccant Plastic droppers Package insert (instruction for use) CTK Products at a Glance Inserts Poster U.S. CDC: hepatitis B Virus FAQs for Health Professionals WHO: Health Topic for Hepatitis

Send Message
product image
Glucometer

FREESTYLE LIBRE PRO Flash Glucose Monitoring System Product Description FreeStyle Libre Pro is clinician's glucose assessment tool that redefines easy. FreeStyle Libre Pro is for the use by Healthcare Professionals only. Easy for patients. Convenient and scalable for clinic. FreeStyle Libre Pro Sensor Small and discreet The FreeStyle Libre Pro sensor is applied on the back of the upper arm. The sensor is water resistant1. Very thin filament Filament is <0.4 mm thick and inserted 5 mm beneath the skin surface to measure glucose levels. Up to 14 days of data Automatically records glucose level every 15 minutes to provide more insightful patterns. Data is blinded from the patient No patient interaction with the sensor is required — designed to integrate with patients' daily lives. FreeStyle Libre Pro Reader The reader stays in the clinic No need to worry about patients losing or damaging components. One reader device starts multiple patients Multiple patients per reader minimizes waiting time and scheduling issues. Lower costs for the clinic The need for only one reader device can help lower your clinic expenses. FreeStyle Libre Pro is an innovative sensor-based ‘Flash Glucose Monitoring’ device that captures glucose readings every 15 minutes for up to 14 days, and gives complete glucose profile report in the form of 'Ambulatory Glucose Profile'. Daily Patterns with Ambulatory Glucose Profile AGP offers a standardized visualization of glucose data that is reliable, predictive, and actionable. The glucose data, generated by Flash Glucose Monitoring over several days or weeks, are collapsed into a single 24-hour period, creating a view of a modal day. This view reveals underlying patterns in glucose variability to a greater extent than using HbA1c by itself. AGP allows healthcare professionals to more effectively visualize and utilize glucose data in the clinical management of diabetes. AGP identifies areas of hyperglycemia, hypoglycemia and glucose variability. Daily Glucose Summary With ‘Daily Glucose Summary’ report, it is easier to know patient’s ‘Time in Target’ Product Specification Model Name/Number Freestyle Libre Pro Averages 14 Days Result Time 3 sec Display LCD Memory Capacity 500 test results Power Supply 1 battery (type CR2032) Sample Type Peripheral Capillary Whole Blood/Venous Whole Blood Weight 45g Including Battery Hematocrit Range 50% Minimum Order Quantity 5 Piece

Send Message
product image
Glycohemoglobin Analysis

Buy Xpress Gluco + Test Strips (Pack of 50 Strips) Online from Accurex Point of Care (POC) Diagnostics. The Sugar machine strips require a sample volume of 0.5 μL and taking just 5 seconds to return a test result. XPRESSGLUCO+ strips make the testing experience superior. These Glucometer strips are for self-testing by people with diabetes at home and health care professionals in a clinical setting to monitor glucose concentrations in capillary whole blood drawn from the fingertips, forearm, upper arm, palm, calf or thigh Accurex Blood Glucose test strips provide accurate results in just 5 seconds. XPRESSGLUCO+ Blood Glucose Test Strips are used with the XPRESSGLUCO+ Blood Glucose Meters. They are intended for self-testing by people with diabetes at home and health care professionals in a clinical setting to monitor glucose concentrations in capillary whole blood drawn from the fingertips, forearm, upper arm, palm, calf or thigh. They are for testing outside the body (in vitro diagnostic use only). Donot use them for diagnosis of diabetes or testing on neonates. Specification Glucose in the blood samples mixes with a special chemical in the test strip and produces a small electric current. The amount of current produced changes with the amount of glucose in the blood. The glucose meter measures the strength of the current and displays the results as a blood glucose level. Safety Information • Discard used test strips and lancets responsibly according to your local regulations. • Keep test strips vial away from children. A child could choke on the test strips. The test strips and their vial contain agents that may be harmful if swallowed. If they are swallowed, promptly see a doctor for immediate assistance. Do not change medication based on the test results without the advice of a physician or healthcare professional. Direction for Use • Prior to first use, ensure that the package is undamaged and closed. • Keep the test strip vial away from sunlight and in a cool, dry place between 5 – 40°C (41 – 104°F). Do not freeze it. • Store test strips in their original pack only. Do not put the test strips in any other container. • Use test strips immediately after removing from the package. • Do not use test strips after the expiration date. • Avoid getting dirt, food or water on the test strip. Do not handle test strips with wet hands. All parts of the test strip should be touched only with dry and clean fingers. • Do not perform blood glucose tests at a temperature below +10°C (50°F) or above +40°C (104°F), or above 85% relative humidity Other Info Each test strip is plasma-calibrated†, requiring a sample volume of 0.5 μL and taking just 5 seconds to return a test result. The test range is 20 to 600 mg/dL (or 1.1 to 33.3 mmol/L) with resolution at 1 mg/dL (0.1 mmol/L). †Plasma-calibrated: Test results produced on capillary whole blood samples by XPRESSGLUCO+ System are compared with the results of the corresponding plasma samples tested by the YSI 2300 Glucose Analyzer, calibrated by YSI 2747 Glucose Standard (a NIST traceable glucose standard). The margin of error of the YSI 2300 Glucose Analyzer measurement is 0.289 mg/dL when the blood glucose concentration is higher than 100 mg/dL, or 0.029 mg/dL when the blood glucose concentration is lower than 100 mg/dL. (1 mmol/L= 18 mg/dL).

Send Message
product image
Glycohemoglobin Analysis

XPRESSGLUCO+ strips make the testing experience superior. These Glucometer strips are for self-testing by people with diabetes at home and health care professionals in a clinical setting to monitor glucose concentrations in capillary whole blood drawn from the fingertips, forearm, upper arm, palm, calf or thigh Accurex Blood Glucose test strips provide accurate results in just 5 seconds. Buy Xpress Gluco + Test Strips (Pack of 100 Strips) Online from Accurex Point of Care (POC) Diagnostics. The Sugar machine strips require a sample volume of 0.5 μL and taking just 5 seconds to return a test result. XPRESSGLUCO+ Blood Glucose Test Strips are used with the XPRESSGLUCO+ Blood Glucose Meters. They are intended for self-testing by people with diabetes at home and health care professionals in a clinical setting to monitor glucose concentrations in capillary whole blood drawn from the fingertips, forearm, upper arm, palm, calf or thigh. They are for testing outside the body (in vitro diagnostic use only). Donot use them for diagnosis of diabetes or testing on neonates. Specification Glucose in the blood samples mixes with a special chemical in the test strip and produces a small electric current. The amount of current produced changes with the amount of glucose in the blood. The glucose meter measures the strength of the current and displays the results as a blood glucose level. Specification Glucose in the blood samples mixes with a special chemical in the test strip and produces a small electric current. The amount of current produced changes with the amount of glucose in the blood. The glucose meter measures the strength of the current and displays the results as a blood glucose level. Safety Information • Discard used test strips and lancets responsibly according to your local regulations. • Keep test strips vial away from children. A child could choke on the test strips. The test strips and their vial contain agents that may be harmful if swallowed. If they are swallowed, promptly see a doctor for immediate assistance. Do not change medication based on the test results without the advice of a physician or healthcare professional. Other Info Each test strip is plasma-calibrated†, requiring a sample volume of 0.5 μL and taking just 5 seconds to return a test result. The test range is 20 to 600 mg/dL (or 1.1 to 33.3 mmol/L) with resolution at 1 mg/dL (0.1 mmol/L). †Plasma-calibrated: Test results produced on capillary whole blood samples by XPRESSGLUCO+ System are compared with the results of the corresponding plasma samples tested by the YSI 2300 Glucose Analyzer, calibrated by YSI 2747 Glucose Standard (a NIST traceable glucose standard). The margin of error of the YSI 2300 Glucose Analyzer measurement is 0.289 mg/dL when the blood glucose concentration is higher than 100 mg/dL, or 0.029 mg/dL when the blood glucose concentration is lower than 100 mg/dL. (1 mmol/L= 18 mg/dL).

Send Message
product image
immunoassayReagents

#Immunoassay #Reagents #Biotechnology #LifeScience #Biochemistry #Research #LabLife #Science #AssayDevelopment #Antibodies #Proteins #DiagnosticTesting #ClinicalChemistry #Laboratory #MedicalResearch #Healthcare #ELISA #Fluorescence #Chemiluminescence #Immunology #MolecularBiology #CellBiology #AnalyticalChemistry #Microbiology #BiomedicalScience #Diagnostics #Innovation #Technology #PrecisionMedicine #Biopharmaceuticals #BiomedicalResearch #Bioreagents #Pathology #Immunodiagnosis #Antigen #AntibodyDetection #ResearchAndDevelopment #ClinicalTrials #HealthTech #Biomarkers #MedicalDevices #PrecisionHealth #BiomedicalEngineering #Therapeutics #Pharmaceuticals #DrugDiscovery #Genomics #Virology #Microarray #PCR #FlowCytometry #Biosensors #Nanotechnology #Immunochemistry #MedicalDevices #MedicalTechnology #HealthInnovation #BiotechStartup #HealthTechInnovation #MedicalInnovation #HealthScience #BiomedicalDevices #HealthcareTechnology #LabResearch #Bioassay #Bioinformatics #ClinicalLaboratory #AssayKit #PointOfCare #LaboratoryMedicine #DiagnosticKits #Chemistry #BiomedicalDiagnosis #BiochemicalAnalysis #Immunodiagnostics #InfectiousDiseases #BiomedicalTechnology #DiagnosticInstruments #HealthcareInnovation #MolecularDiagnostics #MedicalInstruments #InVitroDiagnostics #BiomedicalInnovation #ClinicalChemistry #BiomedicalTesting #BiomedicalDevices #HealthcareTechnology #DiagnosticSolutions #BiomedicalSolutions #LabEquipment #HealthcareDevices #BiomedicalDevices #DiagnosticDevices #MedicalDevices #BiomedicalTools #LabTools #ResearchTools #LabSupplies #LaboratoryEquipment #ResearchEquipment

Send Message
product image
immunoassayReagents

#Immunoassay #Reagents #Biotechnology #LifeScience #Biochemistry #Research #LabLife #Science #AssayDevelopment #Antibodies #Proteins #DiagnosticTesting #ClinicalChemistry #Laboratory #MedicalResearch #Healthcare #ELISA #Fluorescence #Chemiluminescence #Immunology #MolecularBiology #CellBiology #AnalyticalChemistry #Microbiology #BiomedicalScience #Diagnostics #Innovation #Technology #PrecisionMedicine #Biopharmaceuticals #BiomedicalResearch #Bioreagents #Pathology #Immunodiagnosis #Antigen #AntibodyDetection #ResearchAndDevelopment #ClinicalTrials #HealthTech #Biomarkers #MedicalDevices #PrecisionHealth #BiomedicalEngineering #Therapeutics #Pharmaceuticals #DrugDiscovery #Genomics #Virology #Microarray #PCR #FlowCytometry #Biosensors #Nanotechnology #Immunochemistry #MedicalDevices #MedicalTechnology #HealthInnovation #BiotechStartup #HealthTechInnovation #MedicalInnovation #HealthScience #BiomedicalDevices #HealthcareTechnology #LabResearch #Bioassay #Bioinformatics #ClinicalLaboratory #AssayKit #PointOfCare #LaboratoryMedicine #DiagnosticKits #Chemistry #BiomedicalDiagnosis #BiochemicalAnalysis #Immunodiagnostics #InfectiousDiseases #BiomedicalTechnology #DiagnosticInstruments #HealthcareInnovation #MolecularDiagnostics #MedicalInstruments #InVitroDiagnostics #BiomedicalInnovation #ClinicalChemistry #BiomedicalTesting #BiomedicalDevices #HealthcareTechnology #DiagnosticSolutions #BiomedicalSolutions #LabEquipment #HealthcareDevices #BiomedicalDevices #DiagnosticDevices #MedicalDevices #BiomedicalTools #LabTools #ResearchTools #LabSupplies #LaboratoryEquipment #ResearchEquipment

Send Message
product image
Clinical Chemistry

HyPort B30 With the higher requirement of the healthcare, and continuing focus on the efficient clinical workflow, the advanced medical technology is always demanded from the patients and hospital. While some hospitals have limited space and budget, they search for a simple pendant solution to enhance the work efficiency and better care for the patient. Mindray HyPort B30 provides a simple, compact and cost-effective design for Anesthesia Pendant and Surgical Pendant in OR and ICU Pendant to meet this requirement. Less space needed with slimmer column design Easy to handle for nurse after reducing pendant weight Hygienic surface with anti-bacteria coating Built-in rails for accessories and no exposed screws

Send Message

Still searching for
healthcare professionals?