Jaipur
+918529833535

'hcv whole blood rapid test'

Items tagged with 'hcv whole blood rapid test'

product image
Rapid Test

The OnSite Leptospira IgG/IgM Combo Rapid Test is a lateral flow chromatographic immunoassay that can be performed within 15-20 minutes by minimally skilled personnel, and without the use of laboratory equipment. This test is intended to be used for the simultaneous detection and differentiation of IgG and IgM antibodies to Leptospira interrogans (L. interrogans) in human serum, plasma or whole blood. It is intended to be used as a screening test by professionals, and provides a preliminary test result to aid in the diagnosis of infection with L. interrogans. Any interpretation or use of this test result must also rely on other clinical findings as well as on the professional judgment of health care providers. Recommended for use: Any person presenting with clinical signs or symptoms consistent with acute infection with interrogans including: high fever, headache, chills, muscle aches, vomiting, jaundice, red eyes, abdominal pain, diarrhea, skin rash After exposure to a known contaminated source Accuracy: 100% specificity and 100% sensitivity in comparison with a reference rapid test on the market Cross Reactivity: No false positive results were observed on specimens from TP, HIV, Dengue, TB, Typhoid Ab , HBsAg, HCV Ab, HEV Ab, H.P Ab, HAV, HCG, RF, ANA, HAMA Interference: No interference were seen with substances: Salicylic acid: 4.34 mmol/L; Glucose: 55 mmol/L; Sodium citrate: 3.8 %; Heparin: 3,000 U/L; Creatinine: 442 μmol/L; Bilirubin: 20 mg/dL; EDTA: 3.4 μmol/L; Hemoglobin: 2g/L; Human IgG: 1000 mg/dL; AlbuminL 60 g/L Shelf life: 24 month Individually sealed foil pouches containing: One cassette device One desiccant 5 μL capillary tubes Sample diluent (REF SB-R0101, 5 mL/bottle) One package insert (instruction for use) CTK Products at a Glance Inserts U.S. CDC Leptospira Homepage: About Leptospira WHO: Leptospirosis Fact Sheets

Send Message
product image
Rapid Test

The OnSite Duo HSV-1/2 IgG/IgM Rapid Test is a lateral flow chromatographic immunoassay for qualitative detection and differentiation of antibodies (IgG and IgM) to herpes simplex virus 1 (HSV-1) and herpes simplex virus 2 (HSV-2) in human serum, plasma or whole blood. This test can be performed in 10 minutes by minimally skilled personnel without the use of laboratory equipment. This test is intended to be used by professionals as a screening test and provides a preliminary test result to aid in the diagnosis of infection with HSV-1 and/or HSV-2. The OnSite Duo HSV-1/2 IgG/IgM Rapid Test uses HSV-1 glycoprotein G1 and HSV-2 glycoprotein G2 for the specific detection and differentiation of IgG and IgM antibodies to HSV-1 and HSV-2 in serum, plasma and whole blood. An HSV-1 and/or HSV-2 IgM positive result indicates an active infection, which may be primary or recurrent. An HSV-1 and/or HSV-2 IgG positive result indicates a recent or past infection. However, a negative test result does not preclude the possibility of infection with HSV-1 and/or HSV-2. Any interpretation or use of this preliminary test result must also rely on other clinical findings as well as on the professional judgment of health care providers. Alternative test method(s) should be considered to confirm the test result obtained by this device. Clinical accuracy: 90.6% sensitivity and 91.4% specificity for anti-HSV-1 IgG detection 93.8% sensitivity and 96.0% specificity for anti-HSV-2 IgG detection 85.0% overall agreement for anti-HSV-1 IgM detection comparing to commercial ELISA 100% overall agreement for anti-HSV-2 IgM detection comparing to BBI Panel (PTH202) Positive rate on random clinical specimens:8% for IgG anti-HSV-1 and 4.9% for IgM anti-HSV-1 (n=10,000); 4.6% for anti-HSV-2 IgG and 1.7% for anti-HSV-2 IgM Cross reactivity: no cross reactivity with the following disease states or special conditions, respectively: palladium, H. pylori, Dengue, Malaria, Typhoid, Toxoplasma, Rubella, CMV, hCG, TB, HAV, HBV, HCV, HEV, HIV, ANA, HAMA, RF (up to 1,000 IU/mL) Interference: No interference was seen with Albumin 60 g/L , Hemoglobin 2 g/L, Bilirubin 20 mg/dL, Heparin 3,000 U/L, Creatinine 442 µmol/L, Salicylic acid 4.24 mmol/L, EDTA 3.4 µmol/L, Sodium citrate 8%, Glucose 55 mmol/L Shelf life: 24 months Individually sealed foil pouches containing: One cassette device One desiccant Capillary tubes (10 µL) Sample diluent (REF SB-R0203, 5 mL/bottle) Package insert (instruction for use) Individually sealed foil pouches containing: One cassette device One desiccant Capillary tubes (10 µL) Sample diluent (REF SB-R0203, 5 mL/bottle) Package insert (instruction for use)

Send Message
product image
Rapid Test

Buy AccuTest HCV Rapid Card Test (30 Tests) Online from Accurex. HCV means Hepatitis C Virus which is a is a small, enveloped, positive-sense, single-stranded RNA virus. Hepatitis C symptoms are fever, fatigue, decreased appetite, nausea, vomiting, abdominal pain, dark urine, pale feces, joint pain and jaundice. HCV test is a rapid Chromatographic Immunoassay work on principle of the double antigen sandwich technique, Qualitative detection of antibodies generated against proteins that are encoded by conserved sequence of core NS3, NS4, NS5 parts of HCV genome in human whole blood/serum or plasma. AccuTest HCV Test is a rapid Chromatographic Immunoassay for the Qualitative detection of antibodies generated against proteins that are encoded by conserved sequence of core NS3, NS4, NS5 parts of HCV genome in human whole blood/serum or plasma. Hepatitis C Virus (HCV) is a small, enveloped, positive-sense, single-stranded RNA virus. Antibody to HCV is found in over 80% of patients with well documented non-A, non-B hepatitis. Conventional methods fail to isolate the virus in cell culture or visualize it by electron microscope. Cloning the viral genome has made it possible to develop serologic assays that use recombinant antigen, multiple antigens using recombinant protein and/or synthetic peptides have been added in new serologic tests to avoid nonspecific cross-reactivity to increase the sensitivity of HCV antibody tests. Storage and Stability: AccuTest HCV should be stored at 4-30C. However, the card may be stored at room temperature not exceeding 30C in the original sealed pouch. Test Procedure: 1. Allow the test, specimen and or control to room temperature prior to the testing 2. Remove one test card from the pouch and place it on a clean flat surface 3. Using the dropper provided one drop of serum/plasma or W. blood sample (30ul) then two drops of buffer (40ul) immediately into the sample well. Avoid overflowing 4. Read results within 15 minutes. Strong positive reaction may visible within 5 minutes. Do not read results after 15 minutes. 5. If negative or quest Principle: AccuTest HCV Rapid Hepatitis C Virus Test (Serum/Plasma/Whole Blood) is a lateral flow chromatographic immunoassay based on the principle of the double antigen-sandwich technique. The membrane is coated with recombinant HCV antigen on the test line region of the device. During testing, the serum/plasma or W.Blood specimen reacts with HCV antigen coated particles. The mixture migrates upward on the membrane chromatographically by capillary action to react with recombinant HCV antigen or membrane and generate a colored line. Presence of this colored line indicates a positive result, while its absence indicates a negative result. To serve as a procedural control, a colored line will always appear at the control line region, indicating that the correct volume of specimen has been added and membrane wicking has occurred. Storage and Stability: AccuTest HCV should be stored at 4-30C. However, the card may be stored at room temperature not exceeding 30C in the original sealed pouch. Test Procedure: 1. Allow the test, specimen and or control to room temperature prior to the testing 2. Remove one test card from the pouch and place it on a clean flat surface 3. Using the dropper provided one drop of serum/plasma or W. blood sample (30ul) then two drops of buffer (40ul) immediately into the sample well. Avoid overflowing 4. Read results within 15 minutes. Strong positive reaction may visible within 5 minutes. Do not read results after 15 minutes. 5. If negative or questionable results are obtained, the HCV infection is suspected, the test should be repeated ona fresh serum specimen. Safety Information •Positive: If a distinct purple line is formed at the test one marked ‘T’ (Test Line) and the Control Zone marked ‘C’ (Control Line) the test result is positive, indicating the sample contains Hepatitis C antibody. The interpretation of test results (+ve for hepatitis) remains unchanged even if there is a difference in intensity of color in positive line and control line as is many a time found. •Negative: If a distinct purple line is formed only at the control zone marked ‘C’ (control line) the test result is negative • Invalid: A total absence of color in both © and (T) regions or no colored band appears on the control © region is an indication of procedure error and/or the test reagent has deteriorated. Repeat with a new test kit. Direction for Use Test Procedure 1. Allow the test, specimen and or control to room temperature prior to the testing 2. Remove one test card from the pouch and place it on a clean flat surface 3. Using the dropper provided one drop of serum/plasma or W. blood sample (30ul) then two drops of buffer (40ul) immediately into the sample well. Avoid overflowing 4. Read results within 15 minutes. Strong positive reaction may visible within 5 minutes. Do not read results after 15 minutes. 5. If negative or questionable results are obtained, the HCV infection is suspected, the test should be repeated ona fresh serum specimen. Other Info Storage and Stability AccuTest HCV should be stored at 4-30C. However, the card may be stored at room temperature not exceeding 30C in the original sealed pouch.

Send Message
product image
immunoassayReagents

Cortisol Rapid Quantitative Test The Finecare™ Cortisol Rapid Quantitative Test is a fluorescence immunoassay for quantitative determination of Cortisol in human serum, plasma or whole blood. The test is used as an aid to the screening of adrenal dysfunction and assessment of the treatment effect. STORAGE AND STABILITY 1. Store the test kit at 4~30℃ up to the expiration date printed on package. 2. If removed from refrigerator, allow the test kit for 30 minutes to return to room temperature before testing. 3. Do not remove the test cartridge from the pouch until use. The test cartridge should be used within 1 hour once opened.

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ Ferritin Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA Meters for quantitative determination of Ferritin in human whole blood, serum or plasma. The test is used as an aid to the assessment of iron deficiency anemia. STORAGE AND STABILITY 1. Store the test kit at 4 ~30℃ up to the expiration date printed on the package. 2. Do not remove the Test Cartridge from the pouch until ready to use. The Test Cartridge should be used within 1 hour once opened.

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ S100β Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA Meters for quantitative determination of S100β in human serum, plasma or whole blood. The test is used as an aid to the assessment of the level of cerebral injury. STORAGE AND STABILITY 1. Store the test kit at 4 ~ 30 ℃ up to the expiration date printed on package. 2. If removed from refrigerator, allow the test kit for 30 minutes to return to room temperature before testing 3. Do not remove the Test Cartridge from the pouch until use. The Test Cartridge should be used within 1 hour once opened.

Send Message

Still searching for
hcv whole blood rapid test?