Jaipur
+918529833535

'graphic load interface'

Items tagged with 'graphic load interface'

product image
Hematology

VES MATIC 5 is the next-generation automated module manufactured by Diesse Diagnostica (Italy), a highly advanced, Intelligent, Intuitive & Interactive Graphic user Interface for estimating ESR using EDTA samples. Product Features: Automated instrument for the determination of ESR directly from EDTA vacutainers Faster TAT by loading 216 sample tubes at a time Pediatric samples can be processed in microtainers Reliable results with Temperature correction facility Accurate results by eliminating manual HCT correction in Anaemic samples Real-Time monitoring of samples Detection of Lipemic, Hemolyzed, Coagulated samples Standardization in mixing with Inbuilt Mixer Analyser P. Code Product Name Pack size Vesmatic 5 165941 Next 5K Transponder 1x 5000 Vesmatic 5 165942 Next 10 K Transponder 1x 10000 Display - 19" Full HD (1920x1080) LCD with PCAP Touch Screen Peripheral Control - based on Everex distributed control system with peripheral motor control boards Operating system - Linux Analysis module - 89 Positions for Sample Tubes Sample Loading - up to 18 racks simultaneously Throughput - 190 samples per hour. First result after 28 minutes Walk away mode - Supported Continuous loading - Supported Sample mixing - with multiple 180° rotations of the tubes Collection of analysed samples - reinserted into the original loading rack LIS Connection - Multiple LIS connection protocols are available: ASTM / Proprietary Remote diagnostics - available via Ethernet connection. Printer -Alphanumeric with 58mm-wide thermal paper, 36 characters per line, speed 20 mm/sec. Imaging System - 2 high resolution cameras for sample identification and analysis; 1 standard camera for internal inspection Image processor - Dedicated Quad Core CPU with integrated GPU for real-time HD image processing of samples Temperature range in operation - from +15 to + 35°C; Storage from + 5°C to + 45°C Humidity range - from 20% to 80% without condensation Central unit - Quad core ARM Cortex A-53 CPU ARM Cortex A-53, 16 GB eMMC, 4 GB RAM Interfaces - 2 x RS232C, 2 Host USB, 1 Client USB, Ethernet Protection category - CLASS I Safety standard - EN 61010-1, EN 61010-2-081, EN 61010-2-101 EMC - EN61326-1 Installation category - II Mains voltage - 230VAC@50Hz; US/Canada: 110-120Vac@60Hz Electrical energy consumption - 420VA Fuse block - 2 x 5.0 AT (delayed) (5 x 20 mm) UL Dimensions (mm) - 850 (W) x 750 (H) x 830 (D) Weight - 80 kg

Send Message
product image
Clinical Chemistry

Best Fully Automated Clinical Chemistry Analyzer – Sphera M from Accurex. This chemistry analyzer is made in Italy & provides Accurate, Precise and Rapid Testing Solution. Sphera M is a Compact, fully automated, open random-access analyzer. The Minimum reaction volume is 210 µl, Minimal < 1L/h water consumption, 80 reusable UV transmitting Bionex® plastic cuvettes, 8-step wash station. It has Removable refrigerated tray with 30 open reagent positions for 50 ml or 20 ml bottles. Multiple virtual reagent disks can be programmed. The Chemistry analyser also does Auto-wash of inner & exterior probe surface. QUALITY CONTROL & CALIBRATION QUALITY CONTROL: • Levey-Jennings plots and Westgard multi rules • Upto 3 QC levels per test • QC monitor and reports • Method statistics: Test counter, CV%, mean, graphical trend analysis CALIBRATION: • Method and reagent monitor (volumes, available tests, calibration, QC status) • Automatic pre-dilution for calibrators • Upto 8 calibrators per method • Auto recalculation of result using last calibration. UNIQUE SOFTWARE DESIGN AND ARCHITECTURE: • Software designed for touch screen use • Intuitive user interface • Continuous loading of samples and reagents • Random-access and STAT • Free choice of execution order • Extended walk-away capability • Results archive with cumulative charts • Programmable automatic start up routine • Multiple work lists INTERFACE: • Bi-directional LIS, ASTM, over ethernet port of the external PC • Positive identification of samples with internal barcode reader (optional) • Printing on any Windows 7®/8® compatible printer • Method defined washing programs SYSTEM PACKS FOR SPHERA™ Accurex has developed dedicated system packs for Sphera™. Our biochemistry reagents have been intensively evaluated and validated to achieve the highest performance in Sphera™. Accurex recommends the use of these system packs according to instructions and applications validated by Accurex. Safety Information 8-step wash station for thorough cleaning of each cuvette (Needles: 6 dispensing, 6 aspiration, 1 cleaning) • Two types of systemic and special washing solutions for removing obstinate probe residues Direction for Use QUALITY CONTROL • Levey-Jennings plots and Westgard multi rules • Upto 3 QC levels per test • QC monitor and reports • Method statistics: Test counter, CV%, mean, graphical trend analysis CALIBRATION • Method and reagent monitor (volumes, available tests, calibration, QC status) • Automatic pre-dilution for calibrators • Upto 8 calibrators per method • Auto recalculation of result using last calibration Other Info Accurex has developed dedicated system packs for Sphera™. Our biochemistry reagents have been intensively evaluated and validated to achieve the highest performance in Sphera™. Accurex recommends the use of these system packs according to instructions and applications validated by Accurex.

Send Message
product image
Urinalysis

Product Description: This is a continuous loading system for automatic movement, timing, measurement & evaluation of urine test strips. Product Features: High Throughput - High Memory Capacity Easy operation via touchscreen Product Application: Automated reading of Urine test strips that avoids subjective errors in visual reading Technical Specifications: System: Continuous loading Semi-automated Urine test strip analyzer Type: Reflectance photometer Measuring System: Wavelengths – 460 nm, 530 nm, 610 nm Memory: 1000 results Throughput: 400 tests /hr User interface: LCD touchscreen (800 x 480 pixel) Printer: Built-in Thermal Printer Certificates: CE Physical Dimensions: 300 x 287 x 148 mm Weight : 3.2 Kg Test Strips: DekaPHAN Laura & MicroalbuPHAN Laura Parameters: Specific Gravity, Leucocytes, Nitrite, pH, Protein, Glucose, Ketone, Urobilinogen, Bilirubin, Blood & Microalbumin, Creatinine Optical QC: Grey QC strip System Interface: Communication via RS232 & USB port Host Protocol: Uni-directional Sample Identification: Sample ID via keyboard entry, barcode reader Power source: AC 100-240V/50-60 Hz Power consumption: ≤45 W

Send Message
product image
Clinical Chemistry

Product Description: Fully Automated 5 Part Differential Analyser with continuous loading Product Features: Tri angle laser-based flow cytometry for WBC and differentials enumeration 33 reportable parameters including NLR, P-LCC, P-LCR, Mentzer index and RDWI 20 µl sample volume Throughput 80 samples/ hr Large storage capacity of 100000 samples Bidirectional Interfacing Large coloured LCD touch screen of 22 inch Product Application: CBC + Diff Analysis Mode Type: Whole Blood, Predilute, Capillary Autoloader: 60 Tubes; Continuous Loading with Auto-Mixing 33 Parameters: CBC: WBC, RBC, Hb, HCT, MCV MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PCT, PDW-SD, PDW-CV, P-LCR, P-LCC, DIFF: Neutrophils % & #, Lymphocytes % & #, Monocytes % & #, Eosinophils % & #, Basophils % & # *ALY % & #, *LIC % & #, *NLR, *Mentzer index and *RDWI *Research use only Principle of Measurement: RBC/PLT/WBC : Electrical Impedance WBC DIFF: Tri-angle Laser Flowcytometry Hb: Cyanide Free Colorimetry MCV: Measured HCT: Calculated Histograms : 3 (RBC/WBC/PLT) Scattergrams : 3 (2D Scattergram), 1 (3D Scattergram) QR Code Reader: For reading sample bar codes & direct input of QC values Sample Volume: Whole Blood: 20 µL Pre- diluted: 20 µL Capillary: 20 µL CBC Mode : 13 µL Linearity Range: WBC : 0 - 300 ( x 103/µL) RBC : 0 - 300 ( x 103/µL) Hb: 0 - 25.0 (g/dL) HCT: 0 - 67 (%) PLT : 0 - 3000 (x 103/µL) Calibrator: ELite H Cal Tri-level Controls: Erba H5 CON L, N, H Open Vial Stability at 2 - 8˚C: 16 Days Throughput: 80 Tests/Hr Quality Control: 500 files with L-J Graph X- Bar Analysis Data Storage: 1,00,000 Results with Graphs Dimension (mm): 650x550x610 Weight (kgs): 59 Reagents: ELite 580 Dil ELite H580Lyse1 ELite H580Lyse2 ELite H580Lyse3 Elite H Clean Interfaces: 4 USB ports ( for connecting external devices including external printers) + 1 LAN Port (HL 7, TCP/IP; LIS connectivity) Operating Environment Temperature: 15-40˚C Humidity: 30-90% Power Requirement: A.C. 100 - 240 V with built-in voltage stabiliser 50/60Hz, 200 VA

Send Message
product image
Clinical Chemistry

As the workload and test menu increase, simultaneous management of multiple ELISA protocols can become challenging. The LisaXL has been designed with an open architecture to meet various laboratory needs, providing all the tools necessary for hands-free ELISA processing, increasing the reliability and reproducibility, improving throughput, and freeing the laboratory staff from repetitive steps. LisaXL allows running multiple parameters for over 250 samples in a single batch. Equipped with dual probes and dedicated workstations, drastically improve ELISA workflows. LisaXL is a complete walkway system that minimizes manual errors while improving the accuracy and turnaround time for critical tests. LisaXL provides the flexibility to build and run virtually any ELISA assays. Product Features: Lisa XL is a true walk-away system for any laboratory needs. High Throughput with 6 plates, can process up to 576 tests. A dynamic scheduler ensures optimized system usage and turnaround times by processing 6 plates and up to 12 assays in each plate Onboard flexibility with sample capacity up to 272 and 20 interchangeable racks for reagents and samples. Dual probe processing ensures speed and reliability. "Zero" carryover with high-quality disposable tips. Six individually controlled incubators and shakers with variable temperature, time, and speed settings. Efficient washing with super sweep mode ensures minimum residual volume, with up to 6 different wash buffers. Easy to use touchscreen graphic user interface Product Applications: ELISA Physical Specifications 1 Dimensions Length 1375 mm 55" Height 845 mm 33" Width 850 mm 33.5" Weight 195 kgs (Approx) Power Supply Voltage 100 - 240 Volts Frequency 50 / 60Hz Power consumption 700 W General Specifications Assay per plate Up to 12 Number of ELISA plates Up to 6 Sample capacity Up to 272 Sample / Reagent capacity Total 20 racks Single rack holds 16 sample / reagent tubes Double rack holds 6 x 60 ml reagent bottles (can be used interchangeably) Tip / Dilution box Total 11 locations of 96 capacity each (can be used interchangeably) Reader Specifications Reading Range 0.0 - 3.5 O.D Reading Channels 8 Filter wheel 8 positions 405 nm, 450 nm, 492 nm, 620 nm std* 578 nm and 700 nm optional + 2 open Light source Halogen Lamp Reading mode Single, Dual, ORR Reading time < 1 min (for single filter) Linearity Up to 3.0 O.D (450 nm) Washer Specifications Manifold configuration 16 needles - 8 aspiration & 8 dispensing Precision < 5 % at 300 μl Wash cycle Programmable Residual volume < 5 μl / well Soak time Programmable Washer buffer capacity 6 × 2.25 L Waste water container 1 × 20 L Incubator Specifications Number of incubators Up to 6 Temperature range RT + 5°C up to 50°C Temperature stability ± 1°C Incubation time Programmable Time to set temperature < 6 min Shaking 200 to 800 RPM Shaking Method Orbital Pipetting Specifications Number of probes 2 Tips 300 µl / 1000 µl, Auto / Manual selected Multi-dispensing (Reagent) Minimum volume 4 μl Serum dispensing time < 14 min Reagent dispensing time < 5 min Sample mixing Yes (Automatic) Precision Sample & Reagent Sample Dispensing with 300 µl tip: 3% above 10 µl ± 0.5 µl for 10 µl & less Reagent Dispensing with 300 µl tip: 3% for 25 µl & above Reagent Dispensing with 1ml tip: 5% for 75 µl & above" Process Security Liquid level sensing Well fill verification Clot detection Onboard sample identification Onboard reagent identification Strip verification Buffer sensing Alarms Software Operating System Windows 10 (Embedded) LIS interface Bi-directional, Serial / TCPIP USB Port Graphic load interface Graphical work list Data processing Quantitative, Semi-Quantitative & Qualitative Multi password access Ability to archive data Computer (Base configuration considered, higher configuration can be considered for upgrade after testing) Intel Core i3, 4 GB RAM, 1 TB hard disk Monitor 22" Full HD touch screen

Send Message
product image
Clinical Chemistry

Product Description: XL-640 with CRS is a random access, discrete, patient prioritized, fully automated clinical chemistry analyzer with autoloader designed to meet the needs of today’s modern clinical laboratories with high workload. Once samples are loaded, it is a complete walk-away system. XL 640 CRS is designed to operate smoothly over the long haul and to deliver consistent quality report. Product Features: Throughput of 400 tests/ hour (Photometric) and 640 tests/hour with ISE 56 Reagent Positions with On-board cooling for reagents 162 Sample positions with /Autoloader Separate probes for reagent R1 & R2 and dedicated probe for sample Clot detection for sample probe, Reflex testing and Serum Indices identification 72 permanent hard glass cuvettes with On-board Laundry Automatic dilution for high abnormal samples & Auto Rerun facility Extensive QC Programmes with Levy –Jennings Curve & QC rules. Automatic calculation for Mean SD & CV% Direct loading for primary tubes Touch screen User Friendly GUI with Bi-directional connectivity. System General System Type: Automated, Discrete, Random Access, Patient Prioritized Clinical Chemistry Analyzer with Autoloader Throughput: 400 photometric tests/hour & 640 tests/hour with ISE (*optional ISE with Na, K, Cl, Li) Analytical Methods: 1-Point, 2-Point, Rate-A, Rate-B, Direct Potentiometry(optional) Barcode Reader: Both for Samples & Reagents (Optional) Reactions Tray: 72 hard glass cuvettes Reaction Mixing: Dual Stirrer with variable speed Reading Volume: 180 µl On-Board Laundry: 6 stage cleaning, 2 stage drying Photometer: Multi-wavelength diffraction grating with 12 wavelengths (340, 376, 415, 450, 480, 505, 546, 570, 600, 660, 700 & 750 nm) O.D. Range: 0 - 3.0 Light Source: Halogen Lamp Detector: Silicon Photodiodes Water Consumption: < 14 liters/hour Programmable Parameters: Default system pack parameters + upto 99 user defined parameters, Unlimited profiles and unlimited calculation items Quality Control: Q.C. plot data with Q.C. Rules. Provision for lab mean. Twin plot. Caliberation: K- factor, Linear (1,2 point and multipoint) 4P and 5P Logit-log, Cubic spline,exponential, polynomial. On-board serial dilution for calibrator Power Requirement: AC 220 V ± 10 %, 50 Hz or AC 110 V ± 10 %, 60 Hz Power Consumption: 800 VA Dimensions: Approximately 897 mm (w) x 655 mm (D) x 1170 mm (H) Weight: Approximately 200 Kg Sample Handling Sample: Serum, Plasma, Urine, CSF, Whole blood, other Sample Unit: upto 162 positions for samples/STAT/calibrator/controls with Autoloader Sample Pipetting: 2-70 µl (adjustable in 0.1 µl steps) for biochemistry,70 µl fixed for ISE capacitance probe with liquid level sensing and vertical obstruction detection , clot detection and serum indices and Reflex Testing Auto Rerun: Repeat with same, increade and decresaed volume (upto 1:150) Sample Tubes/Cups: Primary tubes of 5 ml, 7ml and 10 ml and sample cups Reagent Handling Reagent Tray: 56 positions for reagents with on-board cooling Reagent Pipetting: R1: 60 - 300 µl (Adjustable in 1 µl step) R2: 0 or 10 - 300 l (Adjustable in 1 µl step) Capacitance probe with level sensing and vertical obstruction detection System Interface Analyzer-PC: USB PC- HOST Computer: Bidirectional TCP/IP and RS - 232 PC- Printer: USB Operating System: Windows based with Touch Screen User Friendly GUI Database: Unlimited Results

Send Message
product image
Clinical Chemistry

ADVIA Chemistry XPT System An advanced, automated clinical chemistry analyzer for high-volume laboratories The ADVIA® Chemistry XPT System provides timely, reliable results with continuous operation to meet the chemistry workloads of the most demanding laboratories. Delivers high throughput of up to 2400 tests per hour. Manages comprehensive testing with a menu of more than 115 assays. Improves workflow using automation and system technologies such as micro-volume and aliquot retention. Features & Benefits The ADVIA Chemistry XPT System*** is engineered for continuous operation and timely, accurate results—supporting you to reach your full potential today and be prepared for tomorrow. With an advanced user interface that is easy to use and VeriSmart Technology to support accuracy of testing, the ADVIA Chemistry XPT System predictably and consistently delivers timely, reliable results to meet expanding workloads. Simplified, Continuous Operation Simplify operation and training with the intuitive, icon-driven user interface. Extend walkaway times with concentrated reagents that provide high test capacity onboard. Quickly load most system fluids on the fly. Automate calibration, QC, startup, and shutdown. Consistent, Predictable Turnaround Time and Accuracy Offer a comprehensive chemistry menu of over 115 assays, including general and specialty chemistry, DAT, TDM, and specific proteins. Push productivity with a throughput of up to 2400 tests per hour (1800 photometric, plus 600 ISE). Control testing: STAT and specialty samples can always be front-loaded while an automation track is running. Designed for Automation Adapt and grow with direct connectivity to Siemens Healthineers and . Simplify your laboratory operations with connectivity to IT solutions including , , and . Increase productivity and efficiency with direct-from-track sampling and onboard aliquoting that allows samples to be immediately released to the next workstation. Do More with Less Reduce blood-draw requirements with micro-volume technology that uses a single 30 μL sample for up to 15 tests. Eliminate sample callback with automated, pre-programmable dilution, reflex, and rerun testing that uses an onboard aliquot. Improve workflow and accuracy with VeriSmart echnologies that perform hardware and software checks at all stages of sample processing.

Send Message
product image
Instruments

The NB350 neonatal noninvasive ventilator is specially designed for neonatal ventilation, equipped with comprehensive NIV modes to provide reliable non-invasive respiratory support to meet the various needs of neonatal respiratory management. EasySync™ Technology The patented EasySync™ technology analyzes multi-channel parameters including gas flow and pressure without additional sensors, enabling accurate detection of spontaneous breath and improving synchrony in SNIPPV. The EasySync™ technology leads to a good synchronization performance comparable to electrical activity of the diaphragm (Edi). IOC (Intelligent Oxygen Control) The oxygen saturation of neonates tends to fluctuate, requiring caregivers to frequently adjust ventilator’s FiO2 settings. IOC (Intelligent Oxygen Control) achieves a closed-loop FiO2-SpO2 control by maintaining the patient’s SpO2 within the predetermined range, which reduces the workload of caregivers and improves patient safety. Integrated SpO2 monitoring for neonates in real time.1 Automatically adjust FiO2 setting by adaptive algorithm.2 Steadily maintain the SpO2 of neonates within the preset target range. Comfortable and Reliable Patient-interface The specialized patient-interface for the NB350 comes with a variety of sizes to fit for different clinical applications and patients. The ergonomic design with soft, skin-friendly material fully enhances the comfort of neonates throughout therapies. Bonnet/Headgear The bonnet/headgear integrate a fixings lot (seat) for pressure generator to avoid misposition and disconnection of patient-interface. Skin-friendly and breathable bonnet/headgear. Durable headgear hook-and-loop fastener allows easy and quick re-adjustment of the patient-interface. Infant Jet™ Pressure Generator Adjustable nasal prong/nasal mask positioning to adapt different facial orientations. Specifically designed to facilitate Coanda effect, significantly reducing respiratory resistance. Related Articles

Send Message
product image
Instruments

Operate with Ease In the modern busy clinical environment, ease of use is a fundamental requirement for all medical devices. With this in mind, the new SV600 ventilators enable clinicians to set and deliver ventilation therapies quickly and easily via the intelligent ergonomic design and flat user interface. PulmoSight TM Utilizes numerical and graphical displays to show real time resistance, compliance and the spontaneous breathing status. Combined with the dynamic short trend display clinicians are able to monitor and evaluate changes in the patient's pulmonary ventilation and initiate the appropriate therapies. User configurable UI The SV600 ventilators offer exceptional user flexibility. Users are able to configure frequently used parameter controls by making them quick access shortcut keys in the UI. Also the ventilation mode keys can be arranged in order of frequency of use. This enables you to customize device in your way making parameter adjustment easier and quicker. Graphic guidelines The new intuitive graphical display enables users to learn quickly how to navigate and locate mode and parameter controls, thereby reducing errors and improving efficiency. Minimal Maintenance Routine maintenance requires no tools. The new 'door design' means that no tools are required to perform regular routine maintenance of the oxygen sensors, water trap, fan dust filter, HEPA air intake dust filter, etc. This ensures your new device always remains clean and clutter free. Intelligent Decision Making Ventilation modes and decision-supporting tools like Intelligent Assistant are developed on the basis of clinical needs and professional guidelines to help medical personnel calmly make clinical decisions. An extensive range of ventilation modes Smart ventilation solution: AMV TM + IntelliCycle TM Emergency solution: CPRVTM Sequential treatment regimen: Non-invasive ventilation & high flow oxygen therapy Dual channel auxiliary pressure measurements Lung protection kit Expandable Capabilities Securing your devices future is reliant on being able to expand your devices capabilities by interacting or integrating new concepts and technologies. The new SV800 / SV600 ventilators allow just this. Continue the latest electronic software and hardware, your new device is ready to embrace new technological advancement with ease. Integrated neonatal module with tidal volumes as low as 2 ml Plug & Play modules , including SpO2, mainstream or sidestream CO2 Backup air supply in case of air supply failure Seamlessly connected to the hospitals clinical information system via the Mindray BeneLink solution or eGateway solution Brand Mindray Model Name/Number SV600 Patient Age Group Neonatal, Adult, Paediatric Mounting Type ICU Operating Type Automatic Display Full color 15.6 inch Resolution 1920x1080 pixel Compliance IEC 60601-1-2 for EMC

Send Message

Still searching for
graphic load interface?