Jaipur
+918529833535

'fluorescent bead'

Items tagged with 'fluorescent bead'

product image
Biochemistry Analyzer

Overview A fully automated POC Auto Dry Biochemistry Analyzer called Mispa Chem Dx, With Just 3 to 4 drops (100ul) of whole blood to test up to 19 General and Special chemistry tests in less than 12 minutes. Mispa Chem Dx works on absorption spectroscopy where a change in absorbance is detected by an absorption spectrum and an algorithm is used to calculate the end concentration of the sample in the reagent dry disc. The reagent disc consists of lyophilized reagent beads, diluent, and calibration details in the QR code. The reagent disc contains an intelligent internal quality control system IQC which continuously monitors the disc function to ensure reaction stability and optimal disc performance, IQC is the engine that drives the Mispa Chem Dx accurately and precisely Low Sample Consumption Easy to Use Maintenance Free Accurate Result Disposable reagent disc Sample volume: 100µl Testing time: 12 minutes / sample Temperature: 37°C ± 0.3°C Resolution: 0.001Abs Absorbance: 0-3.0Abs Sample type: Heparinized whole blood, serum, plasma (heparin) QC&Calibration: IQC (Intelligent Quality Control/Calibration) Work condition: Temperature:10-30°C Humidity: 30%-70% Testing method: End point, kinetic, fixed time, turbidmetry etc Light source: 12V/20W, Halogen tungsten lamp with life span over 2500 hours Power supply: AC 100V-240V, 50-60Hz Display: Android 7.0 inch 800*480, multi-point capacitive touch screen Storage: 500,000 results Printer: Built-in thermal printer Interface: 4 USB ports, 1 LAN port Dimension: 315*375*475mm. 4.2kg(N.W.), 7kg(G.W.)

Send Message
product image
immunoassay analyzer

A compact and easy-to-use, fluorescence based POCT immunoassay analyzer ichroma™ II is a compact, easy-to-use diagnostic immuno-analyzer to measure the presence of various biomarkers for cardiac, cancer, hormones, infectious diseases, autoimmune diseases, and metabolic diseases. #Immunology#FluorescenceAssay#Bioimaging#LabResearch#BiomedicalLab#MolecularImmunology#BiomedicalInstrument#CellularImaging#QuantitativeBiology#ImmunofluorescenceMicroscopy#BiomedicalAnalysis#Biochemistry#ImmunofluorescentProbes#CellularBiology#ScientificInstruments#FluorescentTechnology#BiomedicalDevices#Immunodiagnosis#FluorescenceDetection#BiomedicalApplications

Send Message
product image
Hematology

BC-6800 Today, laboratories not only need more reliable routine CBC plus 5-part diff WBC testing by way of high processing speed, but are also looking for options that extend the analyzer's output in form of Reticulocytes, Nucleated RBCs, Fluorescent Platelet counts etc. for wider clinical application and research. On the other hand, they are restricted by limited budgets. BC-6800 can help to meet all these needs just perfectly and even exceed the expectations. Additional parameters for further clinical applications IMG(#,%) parameters provide information about immature granulocyte, including promyelocytes, myelocytes and metamyelocytes. HFC*(#,%) parameters represent high fluorescent cell population, such as blasts and atypical lymphocytes. RET(#,%) extend valuable help in the differential diagnosis and/or therapeutic monitoring of anemias. IRF is parameter concerning immature reticulocytes, which can assist in early diagnosis of anemia and monitoring the bone marrow response to therapy. InR*(#,‰) are parameters regarding infected red blood cell. The red blood cells may infected by plasmodium, which can cause malaria. * means research parameters SF Cube Technology SF Cube is a pathbreaking technology for reliable blood cell analysis, including WBC differential, Reticulocytes and NRBC with efficient flagging. After reaction with proprietory reagents, the targeted blood cells undergo 3D analysis using information from scatter of laser light at two angles and fluorescence signals. The 3D scattergram builds the power to better identify and differentiate blood cell populations, especially to reveal abnormal cell population undetected by other techniques. Minimizing interference to ensure more accurate results NRBCs are counted in a dedicated channel by SF cube method, which automatically corrects total WBC count and 5-part Diff results when NRBCs are detected. The Focusing Flow-DC method minimizes the interference traditionally encountered in DC technology to produce near gaussian histograms. PLT-O result avoids the interference from microcytic and fragmented RBCs, large platelets and/or platelet clumps by fluorescent stain, and enhances the results accuracy and sensitivity. High automation to minimize the workload Throughput for 125 tests/hour, autoloader for 100 sample tubes capacity Bi-directional LIS with HL7 or ASTM communication protocol Customizable re-exam rules allow users to define their re-exam criterion according to lab’s practice

Send Message
product image
Hematology

The advanced BC-6800Plus not only provides more reliable routine CBC plus 5-part DIFF results, but also has a higher throughput of up to 200 samples per hour. Based on the new SF Cube technology platform, the BC-6800Plus could provide more reliable blood cell results and abnormal cells flagging results with anticipated warning messages, exceeding clinicians’ expectations and setting a new standard for blood analysis. SF Cube Technology With the newly designed opticals and reagent systems, the SF Cube technology can help doctors to better differentiate the clusters of cells, which is the key to revealing more abnormal cells. NRBC result in every CBC In WNB scattergram, BC-6800Plus provides NRBC, Basophils and WBC-N* results. It means that the actual number of NRBCs can be measured in routine CBC, if they are present in the sample. Basophils are counted in this counting channel with NRBC results. Basophil and NRBC results are generated on BC-6800Plus without extra reagent or cost. NLR parameter in each CBC+DIFF Neutrophil-to-lymphocyte ratio (NLR) is calculated by dividing neutrophil count by lymphocyte count, usually from peripheral blood sample. In laboratory medicine, NLR is used as a marker of subclinical inflammation. According to clinical studies, NLR can be used as a prognostic factor of severe illness in COVID-19 patients. More accurate RET and PLT-O result By utilizing the new fluorescent dye, the reticulocytes and platelets are more specific stained with stronger fluorescent signal, that brings more reliable reticulocyte and platelet results. Automatic Rerun & Reflex Should the sample results trigger the criteria, the sample rack can automatically step back for a “rerun” or “reflex” check. 200 test/hour BC-6800Plus can load up to 100 samples at a time and offers a throughput of up to 200 tests per hour.

Send Message
product image
Rapid Test

STANDARD F HbA1c FIA performs quantitative analysis on glycosylated hemoglobin in whole blood samples using fluorescence immunochromatography. As STANDARD F Analyzer has been enhanced in its performance by using fluorescent substance, accurate quantitative test results can be obtained using with this product. ntented Use This product performs quantitative analysis on glycated hemoglobin in the whole blood samples. Advantage Able to perform accurate quantitative analysis using fluorescent substance Hb S, Hb F, Carbamylated Hemolgobin without interference phenomenon Automatic strip recognition by reading the information stored in 2D barcode IFCC / NGSP certified Specification Specimen Whole blood Test time 5 minutes Specimen volume 5 µl CV% <3%

Send Message
product image
Rapid Test

STANDARD F Chikungunya IgM/IgG FIA qualitatively analyzes Chikungunya virus specific IgM and IgG antibodies in serum, plasma and whole blood using fluorescent immunoassay. Screening test results can be obtained within 15 minutes with high sensitivity and specificity. Intented Use This product performs qualitative analysis on Chikungunya virus specific IgM and IgG antibodies in serum, plasma and whole blood. Advantage Able to perform qualitative analysis with high sensitivity and specificity by using fluorescent substance Objective result - Eliminates the subjectivity of a visual result Automatic strip recognition by reading the information stored in 2D barcode

Send Message
product image
MICROSCOPES

LED Lifespan is >50,000 hrs :Enormous cost saving Only 1/10th of the power consumption compared to the other Fluorescence Microscope. No UV radiation emission & explosion proof Provison for digital camera with 50/50 beam splitter that eliminates the need to transit between camera and eye pieces Transmitted light is integrated for bright & dark field microscopy and can be upgraded for phase contrast. Categories: Fully Automated Immunoassay Analyzer, Fully Automated Immunoassay Analyzer category, Fully Automated Immunoassay Analyzer instruments Product Description Product Description:- LED Lifespan is >50,000 hrs :Enormous cost saving Only 1/10th of the power consumption compared to the other Fluorescence Microscope. No UV radiation emission & explosion proof Provison for digital camera with 50/50 beam splitter that eliminates the need to transit between camera and eye pieces Transmitted light is integrated for bright & dark field microscopy and can be upgraded for phase contrast. Intoduction:- The LED fluorescence microscope EUROStar III Plus has been precisely tailored to the requirements of indirect immunofluorescence. A camera can be attached directly to the integrated photo tube for capturing digital images. Switching between the ocular and the camera is no longer necessary owing to the convenient 50/50 beam splitter. Euroimmun also offers the highly functional EUROPicture software for displaying and handling of the digital images. Information:- Constant fluorescence excitation due to regulated LED for reliable and reproducible results Long life span of over 50,000 hours, low current consumption and full light intensity immediately after being switched on Environmentally friendly without mercury cLED available as separate module for equipping various other microscopes Screen diagnostics and digital image acquisition using optional camera with EUROPicture software 50/50 beam splitter for microscopy without switching between the ocular and the optional camera

Send Message

Still searching for
fluorescent bead?