Jaipur
+918529833535

'f analyzer'

Items tagged with 'f analyzer'

product image
Immunofluorescence Quantitative Analyzer

Getein 1180 Immunofluorescence Quantitative Analyzer is used to measure the concentration of biomarkers in human whole blood, serum, plasma, urine, nasal swab, or saliva samples. Getein 1180 Immunofluorescence Quantitative Analyzer (hereinafter called Getein 1180) is an analyzer for processing and analysis of Getein test kits including biomarkers for cardiovascular diseases, renal function, inflammation, fertility, diabetes mellitus, bone metabolism, tumor, and thyroid function, etc. Getein 1180 is used to measure the concentration of biomarkers in human whole blood, serum, plasma, urine, nasal swab, or saliva samples. The results can be used as an aid in clinical diagnosis of laboratory and point-of-care testing. It is applicable in Emergency, Clinical labs, Outpatient, ICU, CCU, Cardiology, Ambulance, Inpatient Wards, etc.

Send Message
product image
Hematology

At Mindray, we pride ourselves on our dedication and experience in developing better solutions for small labs. Our new 3-part hematology analyzer is the culmination of that effort. It provides small labs with more confidence in results and less turnaround time. Features CBC+3-DIFF, 20 parameters +3 Histograms Throughput: up to 30 samples per hour 8.4 inch TFT touch screen Only three reagents needed Open vial sampling Large storage capacity: up to 50,000 samples Original QC, calibrators and reagents Automation Fully Automatic Instrument Name Hematology Analyzer Brand Mindray Differential Type 2-Part Usage/Application Clinical Number Of Chambers 1 Model Name/Number BC-10 Power Source Electric Voltage 240 V Frequency 50 Hz

Send Message
product image
Hematology

At Mindray, we pride ourselves on our dedication and experience in developing better solutions for small labs. Our new 3-part hematology analyzer is the culmination of that effort. It provides small labs with more confidence in results and less turnaround time. Features CBC+3-DIFF, 21 parameters+3 Histograms Throughput: up to 60 samples per hour 10.4 inch TFT touch screen Only three reagents needed Open vial sampling Large storage capacity: up to 400,000 samples Original QC, calibrators and reagents Product Specification Automation Fully Automatic Instrument Name Hematology Analyzer Brand Mindray Usage/Application Clinical Differential Type 3-Part Number Of Chambers 2 Number Of Parameters LYM Model Name/Number BC-30s User Input Touch Voltage 240 V Frequency 50 Hz Power Source Electric

Send Message
product image
Hematology

BC-6800 Today, laboratories not only need more reliable routine CBC plus 5-part diff WBC testing by way of high processing speed, but are also looking for options that extend the analyzer's output in form of Reticulocytes, Nucleated RBCs, Fluorescent Platelet counts etc. for wider clinical application and research. On the other hand, they are restricted by limited budgets. BC-6800 can help to meet all these needs just perfectly and even exceed the expectations. Additional parameters for further clinical applications IMG(#,%) parameters provide information about immature granulocyte, including promyelocytes, myelocytes and metamyelocytes. HFC*(#,%) parameters represent high fluorescent cell population, such as blasts and atypical lymphocytes. RET(#,%) extend valuable help in the differential diagnosis and/or therapeutic monitoring of anemias. IRF is parameter concerning immature reticulocytes, which can assist in early diagnosis of anemia and monitoring the bone marrow response to therapy. InR*(#,‰) are parameters regarding infected red blood cell. The red blood cells may infected by plasmodium, which can cause malaria. * means research parameters SF Cube Technology SF Cube is a pathbreaking technology for reliable blood cell analysis, including WBC differential, Reticulocytes and NRBC with efficient flagging. After reaction with proprietory reagents, the targeted blood cells undergo 3D analysis using information from scatter of laser light at two angles and fluorescence signals. The 3D scattergram builds the power to better identify and differentiate blood cell populations, especially to reveal abnormal cell population undetected by other techniques. Minimizing interference to ensure more accurate results NRBCs are counted in a dedicated channel by SF cube method, which automatically corrects total WBC count and 5-part Diff results when NRBCs are detected. The Focusing Flow-DC method minimizes the interference traditionally encountered in DC technology to produce near gaussian histograms. PLT-O result avoids the interference from microcytic and fragmented RBCs, large platelets and/or platelet clumps by fluorescent stain, and enhances the results accuracy and sensitivity. High automation to minimize the workload Throughput for 125 tests/hour, autoloader for 100 sample tubes capacity Bi-directional LIS with HL7 or ASTM communication protocol Customizable re-exam rules allow users to define their re-exam criterion according to lab’s practice

Send Message
product image
Hematology

The BC-5390 is a 5-part Auto Hematology Analyzer that delivers high productivity, better accuracy and improved patient care, without sacrificing your budget. The analyzer utilizes the power of three mainstream technologies: laser scatter, flow cytometry, and chemical dye, to provide more accurate clinical information. The BC-5390 has been approved by FDA. Features Robust capacity and functionality Its throughput of 60 samples per hour saves your time, and the capacity of 40 autoloading tubes can extend your walk-away time. More reliable test result.The new reagent, with better anti-aging capacity, helps better differentiate Eosinophils from Neutrophils in the DIFF scattergram, even on samples with high density of Eosinophils. The analyzer is empowered by the fluid sensing technology to detect clot, bubble and insufficient sample, ensuring accurate sample aspiration. Flexible sample aspiration With different holder adapters, the analyzer supports three analysis modes - venous whole blood mode, pre-diluted mode and capillary whole blood mode. Product Specification Model Name/Number BC-5390 Operation Mode Fully Automatic Usage/Application Hospital Brand Mindray Capacity 40 autoloading tubes Throughput 60 samples per hour

Send Message
product image
Laboratory Usage

Using best-in-class technology, the Mindray CL-6000i is a chemiluminescence immunoassay analyzer with high throughput, high performance and high reliability. Features Throughput: up to 480 tests per hour Measurement principle: enhanced ALP-AMPPD method Reagent carousel: 36 reagent positions with non-stop refrigerating Sample handling: up to 300 samples can be loaded in one batch, sample loading and offloading continuously by sample racks, fast prioritizing STAT samples Sample volume: 5-110 μL Continuously loading of reagents, substrate, cuvettes, wash buffer and waste bags Zero daily maintenance Product Specification Model Name/Number CL-6000i Usage/Application Hospital Brand Mindray Sample Volume Range 5-110 microlitre Throughput up to 480 tests per hour Measurement Principle enhanced ALP-AMPPD method Reagent Carousel 36 reagent positions with non-stop refrigerating Sample Handling up to 300 samples can be loaded in one batch,sample loading and offloading continuously by sample r

Send Message
product image
Immunology Analyzer

The CL-900i is a compact, fully-automated CLIA analyzer. With dimensions of just 86cm length, 72cm width, 56cm height, it is specially designed for small volume labs. The analyzer incorporates ergonomic design with an easy-access operating area, which is located on the cover. The machine does not require regular maintenance, providing our customers with the best operating experience, as well as competitive cost performance. Features Basic parameters: Measurement principle: enhanced ALP-AMPPD method Small footprint: 860mm*740mm*560mm (W*D*H) Throughput of up to 180 tests/hour 50 sample positions and 15 reagent positions Chemiluminescence Immunoassay Reagent Reagent Test Menu PC

Send Message
product image
Clinical Chemistry

The Autochem Xact Pro is a Fully Automatic Random Access Clinical Chemistry Analyzer. It is a compact, benchtop analyser with throughput up to 200 tests per hour. First-in-Class On-board Warm-water Laundry System Probe with Collision-Protection System Multi function Probe which works as mixer also Probe with Capacitance based liquid level sensor Robust Multi-functional Software Intelligent" Mixing Arm Removable & flexible Sample - Reagent Disc with 40 Open position for reagent & samples respectively. DESIGNED FOR UNINTERRUPTED WORK FLOW OTHER FEATURES ROBUST MULTI-FUNCTIONAL SOFTWARE Probe with Collision-Protection System Both horizontal and vertical collision protection ensures that system re-starts testing after any unwanted physical intervention. This prevents wastage of reagents, saves test time and increases life of probe Multi functional Probe Probe has flexibility to work even as a mixer in case in-built mixer does not work Probe with Capacitance based liquid level sensor Probe with liquid level sensor checks and indicates the presence of adequate sample or reagent in the container before starting testing process. Thus prevents unwanted interruptions in testing process “Intelligent” Mixing Arm User defined, variable three level mixing speed ensure thorough mixing Accurate performance of regular and immunoturbidimetric assays Independent cleaning station for mixer which prevents carry-over ensuring high precision Removable & flexible Sample – Reagent Disc 40 Open position for reagent & samples respectively Facility to use primary & variable sample cup as well as non fixed position for Sample, Control, Calibrator & STAT samples Two bottle sizes of 18 mL or 5 mL with unique design to reduce reagent dead volume Optional internal Reagent & Sample barcode reader makes the operation user friendly & ensure correct result reporting Reaction tray 60 reusable plastic reaction cuvettes which is also scanned before performing the test which means less recurring cost without compromising on quality. To assure precise results Individual replacement of cuvette offer lower consumable cost REFLEX Testing Functionality Allows user to program Low & High panic value for a particular test which triggers auto-testing of assigned tests which ensures faster and comprehensive reporting Dynamic & Real-time display of Test Running Status for quicker decision making Running status of reagent tray, Sample tray & reaction tray Real-time monitoring of Reaction curve On board inventory management Real-time monitoring of reagent residual volume saves reagent cost & time In-built full QC Program Provision to run 3 levels of control with Levey Jennings graph which gives confidence in reporting with multiple rules (1SD, 2SD and 3SD) Reagent, Calibrator & Control lot monitoring User friendly Bi-Directional LIS Interface

Send Message

Still searching for
f analyzer?