Jaipur
+918529833535

'edta blood'

Items tagged with 'edta blood'

product image
Rapid Test

The OnSite Chikungunya IgM Combo Rapid Test is a lateral flow chromatographic immunoassay for the qualitative detection of IgM anti-chikungunya (CHIK) virus in human serum, plasma or whole blood. Uses serum, plasma or whole blood specimen Utilizes recombinant antigen derived from the CHIK structure protein IgM immunoassay is the most practical lab method Distinguish from dengue infection which presents with similar symptoms Clinical performance: Sensitivity: 90.4% Specificity: 98.0% comparing to a commercial ELISA Cross-Reactivity: no cross-reactivity found on 10-40 specimens from the 14 disease states and special conditions, such as dengue, Zika, malaria, HIV, TB, HAV, pregnant woman and others No interference with some common substances, such as Acetominophen (20 mg/dL), Heparin (3000 U/L), Ascorbic acid (20 mg/dL), Human IgG (1000 mg/dL), Bilirubin (20 mg/dL), Glucose (55 mmol/L), Creatinine (442 μmol/L), Salicylic acid (4.34 mmol/L), EDTA (3.4 μmol/L), Sodium citrate (3.8%) Individually sealed foil pouches containing: One cassette device One desiccant Capillary tubes (5 μL) Sample diluent (REF SB-R0066, 5 mL/bottle) One package insert (instruction for use) CTK Products at a Glance Inserts U.S. CDC Chikungunya Virus Homepage: (Transmission, Prevention, etc.) WHO: Chikungunya Virus Fact Sheets

Send Message
product image
Rapid Test

The OnSite Leptospira IgG/IgM Combo Rapid Test is a lateral flow chromatographic immunoassay that can be performed within 15-20 minutes by minimally skilled personnel, and without the use of laboratory equipment. This test is intended to be used for the simultaneous detection and differentiation of IgG and IgM antibodies to Leptospira interrogans (L. interrogans) in human serum, plasma or whole blood. It is intended to be used as a screening test by professionals, and provides a preliminary test result to aid in the diagnosis of infection with L. interrogans. Any interpretation or use of this test result must also rely on other clinical findings as well as on the professional judgment of health care providers. Recommended for use: Any person presenting with clinical signs or symptoms consistent with acute infection with interrogans including: high fever, headache, chills, muscle aches, vomiting, jaundice, red eyes, abdominal pain, diarrhea, skin rash After exposure to a known contaminated source Accuracy: 100% specificity and 100% sensitivity in comparison with a reference rapid test on the market Cross Reactivity: No false positive results were observed on specimens from TP, HIV, Dengue, TB, Typhoid Ab , HBsAg, HCV Ab, HEV Ab, H.P Ab, HAV, HCG, RF, ANA, HAMA Interference: No interference were seen with substances: Salicylic acid: 4.34 mmol/L; Glucose: 55 mmol/L; Sodium citrate: 3.8 %; Heparin: 3,000 U/L; Creatinine: 442 μmol/L; Bilirubin: 20 mg/dL; EDTA: 3.4 μmol/L; Hemoglobin: 2g/L; Human IgG: 1000 mg/dL; AlbuminL 60 g/L Shelf life: 24 month Individually sealed foil pouches containing: One cassette device One desiccant 5 μL capillary tubes Sample diluent (REF SB-R0101, 5 mL/bottle) One package insert (instruction for use) CTK Products at a Glance Inserts U.S. CDC Leptospira Homepage: About Leptospira WHO: Leptospirosis Fact Sheets

Send Message
product image
Rapid Test

The OnSite Duo HSV-1/2 IgG/IgM Rapid Test is a lateral flow chromatographic immunoassay for qualitative detection and differentiation of antibodies (IgG and IgM) to herpes simplex virus 1 (HSV-1) and herpes simplex virus 2 (HSV-2) in human serum, plasma or whole blood. This test can be performed in 10 minutes by minimally skilled personnel without the use of laboratory equipment. This test is intended to be used by professionals as a screening test and provides a preliminary test result to aid in the diagnosis of infection with HSV-1 and/or HSV-2. The OnSite Duo HSV-1/2 IgG/IgM Rapid Test uses HSV-1 glycoprotein G1 and HSV-2 glycoprotein G2 for the specific detection and differentiation of IgG and IgM antibodies to HSV-1 and HSV-2 in serum, plasma and whole blood. An HSV-1 and/or HSV-2 IgM positive result indicates an active infection, which may be primary or recurrent. An HSV-1 and/or HSV-2 IgG positive result indicates a recent or past infection. However, a negative test result does not preclude the possibility of infection with HSV-1 and/or HSV-2. Any interpretation or use of this preliminary test result must also rely on other clinical findings as well as on the professional judgment of health care providers. Alternative test method(s) should be considered to confirm the test result obtained by this device. Clinical accuracy: 90.6% sensitivity and 91.4% specificity for anti-HSV-1 IgG detection 93.8% sensitivity and 96.0% specificity for anti-HSV-2 IgG detection 85.0% overall agreement for anti-HSV-1 IgM detection comparing to commercial ELISA 100% overall agreement for anti-HSV-2 IgM detection comparing to BBI Panel (PTH202) Positive rate on random clinical specimens:8% for IgG anti-HSV-1 and 4.9% for IgM anti-HSV-1 (n=10,000); 4.6% for anti-HSV-2 IgG and 1.7% for anti-HSV-2 IgM Cross reactivity: no cross reactivity with the following disease states or special conditions, respectively: palladium, H. pylori, Dengue, Malaria, Typhoid, Toxoplasma, Rubella, CMV, hCG, TB, HAV, HBV, HCV, HEV, HIV, ANA, HAMA, RF (up to 1,000 IU/mL) Interference: No interference was seen with Albumin 60 g/L , Hemoglobin 2 g/L, Bilirubin 20 mg/dL, Heparin 3,000 U/L, Creatinine 442 µmol/L, Salicylic acid 4.24 mmol/L, EDTA 3.4 µmol/L, Sodium citrate 8%, Glucose 55 mmol/L Shelf life: 24 months Individually sealed foil pouches containing: One cassette device One desiccant Capillary tubes (10 µL) Sample diluent (REF SB-R0203, 5 mL/bottle) Package insert (instruction for use) Individually sealed foil pouches containing: One cassette device One desiccant Capillary tubes (10 µL) Sample diluent (REF SB-R0203, 5 mL/bottle) Package insert (instruction for use)

Send Message
product image
Glucometer

The GLUCOCARD Vital is everything a blood glucose meter should be - fast, accurate and easy to use. A small 0.5 µL sample size in our GO-based test strip platform gives accurate results in as little as 7 seconds. This auto coded meter has a 250-test memory, records 14- and 30-day averaging and is downloadable. Sample volume: 0.5 μL Test time: 7 seconds Meter range: 20-600 mg/dL Results: Plasma referenced Calibration: Auto coding Display: LCD Memory: 250 tests with time & date stamp Averaging: 14- and 30-day averaging Downloadable: Yes

Send Message
product image
Glucometer

STANDARD Mentor The pain associated with blood drawing has been minimized because it has been developed to measure accurately even with an amount of blood as minimal as 0.3 µl. About this item Approved Glucometer : FDA and KMFDS Approved, Accuracy Criteria : Its Fulfills EN ISO 15197 : 2015 International Standards. Minimum Blood Sample Needed : 0.3 μl, Memories : Standard Mentor Glucometer allows to save previous and up to 500 test Memories Box Included : Glucometer, 10 Lancets, 10 Strips, 1 Lancing Device, 1 Meter Check Strip, 3V Battery type CR2032, Carrying case, User Instruction Guide, Warranty Card. Pre & Post Meal Mark Alarm, No Coding Glucometer, 99.9% Gold Electrode Strip. Authorized Representative : MT Promedt Consulting GmbH - Altenhofstrasse 80 66386 St. Ingbert Germany. Warranty & Support : Standard Mentor Glucometer comes with Lifetime Warranty and support provided by Standard, For any product queries contact (18001023105). Advantage Minimized pain associated with blood drawing with an amount of blood as minimal as 0.3 µl No coding Accuracy that meets international standards

Send Message
product image
Glucometer

SD CodeFree A representative model of of SD BIOSENSOR which is easy to use and provides accurate results without the need for coding. The SD Codefree Blood Glucose Meter is a compact, hand-held, and easy-to-read monitor that stores up to 500 test results. It provides an accurate picture of your blood glucose level at the time of the test from a small droplet of blood. Specification Enzyme Glucose Oxidase biosensor Measurement Range 10 - 600mg/dL (0.6 - 33.3 mmol/L) Specimen volume 5 sec Sample Volume 0.9 µl Hematocrit 20 - 60% Unit mg/dL Memory Up to 500 tests Battery 3V battery (CR2032) Interpretation of results Cat. No. Product Component Note 01GC110 SD CodeFree™ Blood Glucose Monitoring System Meter, Test Strip (10EA) / Lancet(10EA) / Lancing Device / Check Strip 01GS11 SD CodeFree™ Blood Glucose Test Strip SD CodeFree™ Test Strip (25EA x 2 bottle)

Send Message
product image
Glucometer

Accu-Chek® Instant Blood glucose monitor Your effortless choice Item Description Wishing there was an easy way to monitor your blood glucose levels? With the new Accu-Chek Instant meter, it's as easy and fast as checking your phone messages. There is no setup required – just insert a test strip, apply a small blood sample and read your blood glucose result on the large display. Additional specifications Model: Accu‑Chek Instant wireless blood glucose meter​ Meter storage conditions: Temperature: -25 – 70° C Memory capacity: The meter automatically stores at least 720 blood glucose results in memory, but only the last blood glucose result and your 7, 30, and 90 day averages can be viewed on the meter. To view stored blood glucose results, transfer them to a compatible software application. The meter automatically stores at least 30 control results in memory, but only the current control result can be viewed on the meter. To view stored control results, transfer them to a compatible software application. Sample claims: Capillary: Yes Venous: Yes Arterial: Yes Neonate: Yes Non-fingerstick sample Claim: Palm, forearm, upper arm Measuring principle: FAD glucose dehydrogenase (GDH) Measuring time: 4 Sec Measuring conditions: 4 °C to 45 °C (39 °F to 113 °F) Hematocrit range: 10 to 65 % Humidity range: 10 to 90 % Altitude independence: 0 to 3,094 m (10,150 ft) Automatic off: 90 seconds after performing a test, 15 seconds after test strip is removed, or 5 seconds from the last test result screen. Weight: Approx. 40 g (with batteries) Construction: Hand-held Protection class: III Meter type: The Accu-Chek Instant meter is suitable for continuous operation. Interfaces: Connectivity using BLE wireless Technology to mySugr App; USB interface with USB cable to transfer data to the Accu‑Chek Connect Online system. Benefits and Features Effortless Bluetooth synchronization with mySugr diabetes management app The intuitive target range indicator gives you visual reassurance. It can be individualized to suit your personal therapy goals Only what you need: Your test result and your averages (7/30/90 days) are visible on the meter Sleek, modern design with large, easy-to-read BG numbers and a bright, backlit display No set up required – just insert a strip, apply a small blood sample, and read your blood glucose result on the large display Easy-edge test strip: Apply a small drop of blood anywhere along the wide, yellow edge Proven accuracy guaranteed by the makers of the Accu-Chek brand, fulfilling the requirements of the ISO 15197:2013, EN ISO 15197:2015 All data can be uploaded to the mySugr by using Bluetooth Low Energy wireless technology and to Accu-Chek Connect Online portal by using USB Test strips come in a 10, 25, 50 vial so you can choose whatever fits your budget or therapy Enjoy virtually pain-free testing with the Accu-Chek Softclix lancing device

Send Message
product image
Glucometer

Accu-Chek® Active blood glucose meter Personalised Diabetes Coaching Accurate, no coding, easy Item Description The Accu-Chek Active blood glucose meter packs many powerful features into a smaller size. No coding reduces handling steps, see test result averages up to 90 days, get alerts if your test strips are expired or if you’ve underdosed, re-dose within 10 seconds, set pre-and post-meal reminders to test, and more. Benefits and Features accurate: Accurate1 blood glucose measurement easy: No coding for even easier blood glucose monitoring easy-to-read display (new typeface) intuitive handling with just 2 buttons safe: Underdose detection visual double check 10 seconds re-dose option clever: Pre- and postmeal markers postprandial reminder 7,14,30 or now 90 day test averages USB interface for data transfer Remark: Previous Accu-Chek Active meter generations will be upgraded to no coding via black activation chip . Know more>> 1The Accu-Chek Active bGM system meets the DIN EN ISO 15197:2013 requirements (data on file, 2014). Additional specifications Meter type : Accu-Chek Active meter (Model GB) Catalogue no. / Serial no. : See type plate on the back of the meter Test principle : Determination of glucose in fresh capillary blood by reflectance photometry. Blood glucose values can be tested in whole blood or plasma. The meter displays blood glucose values corresponding to those in plasma. Measuring interval : 10-600 mg/dL Blood volume : 1-2 μl Measuring time : Test strip in the meter: approx. 5 seconds Test strip outside the meter: approx. 08 seconds Power supply : 1 battery (type CR2032) Battery life : approx. 1000 tests or approx. 1 year Automatic power-off : after 30 or 90 seconds depending on operating status Memory : 500 test results with time and date, as well as 7, 14, 30 and 90 days averages Temperature : During testing: +8 to +42°C During storage without battery: -25 to +70°C During storage with battery: -20 to +50°C Atmospheric humidity : During testing: up to 85% relative humidity During testing: up to 93% relative humidity Altitude: Sea level to 4000 m Dimensions : 97.8 x 46.8 x 19.1 mm Weight : Without battery: approx. 46 g With battery: approx. 50 g Display : 96-segment liquid crystal display (LCD) Interface : USB (Micro B) Safety class : III Electromagnetic compatibility : The Accu-Chek Active meter meets the electromagnetic immunity requirements and the electromagnetic emissions requirements as per EN 61326-2-6 and EN ISO 15197 Annex A. The chosen basis for electrostatic discharge immunity testing was basic standard IEC 61000-4-2. Performance analysis : Calibration and traceability: The performance data for the Accu-Chek Active bGM system was calibrated using venous blood containing various glucose concentrations. Reference values are obtained using the hexokinase method, which is calibrated using the ID-GCMS method. Accuracy performance : The Accu-Chek Active bGM system meets the DIN EN ISO 15197:2013 requirements (data on file, 2014). How to use Accu-Chek Active blood glucose meter Testing your blood glucose is an essential part of managing diabetes. The Accu-Chek Active blood glucose meter can help to make it convenient by giving you fast, hassle-free, and accurate results in 4 simple steps. Insert the glucose test strip Prick your finger with the lancet to draw out a blood drop. Carefully touch the blood drop onto the green field of the test strip. Read the blood glucose result.

Send Message
product image
Glucometer

Accu-Chek® Guide Blood Glucose Meter Surprisingly Clever Diabetes is complex. Your testing doesn’t have to be Item Description Diabetes is complex. Your testing doesn't have to be with the Accu-Chek® Guide blood glucose monitoring system. With a spill resistant SmartPack® vial, a strip that lets you place a small drop of blood anywhere along the end, and an app that automatically logs results to your phone, it's a surprisingly simple way to manage your diabetes. Benefits and Features Simple to log results without a paper logbook - automatically logs results right to a mySugr app on your smartphone Simple to take just one strip - spill-resistant SmartPack vial lets you take one and spill none Simple to dispose off used test strips - push-button strip ejector means you don't have to touch used strips Simple to see, day or night - strip port light for testing in daytime, nighttime or anytime Simple to be more accurate - delivers advanced 10/10 accuracy for reliable results you can trust1,2,3 Meter Specifications Models: Accu‑Chek Guide wireless blood glucose meter Serial number: Unique serial number etched into meter back Sample claims: Capillary: Yes Venous: ROW = Yes Arterial: ROW = Yes Non-fingerstick sample claim ROW: Palm, forearm, upper arm Measuring principle: FAD glucose dehydrogenase (GDH) Measuring time: Less than 4 seconds Measuring conditions: 4°C to 45 °C (39°F to 113 °F) Storage conditions: -25 °C to +70 °C (-13 °F to +158 °F) Hematocrit range: 10 to 65% Humidity range: 10 to 90 % Altitude independence: 0 to 3,094 m (10,150 ft) Memory capacity: Up to 720 measurements with date and time; 32 control measurements Test averages: 7, 14, 30 and 90 days Data transfer wireless connectivity: using Bluetooth Smart Low Energy Dimensions: 80 x 47 x 20 mm (L x W x H) Weight Approximately: 40 g with batteries Display: Large backlit LCD display with full-text capabilities Beep tone: Yes (factory setting ON) Batteries: (2) 3-volt lithium coin cell type CR2032 Auto power off: 15 seconds after removing a test strip; 90 seconds otherwise Blood volume: 0.6 μL Measuring range: 10 to 600 mg/dL Sample types: Capillary, venous, arterial and neonate Sample dosing: Capillary fill function; suitable for AST Test strip stability 18 months after production date: Test strips are stable (even after opening) until the expiry date printed on the test strip vial. Note: Test strip container must be tightly closed after each strip is removed. Storage temperature : 4 °C to 30 °C (39 °F to 86 °F)

Send Message

Still searching for
edta blood?