Jaipur
+918529833535

'dl acetylsalicylic acid'

Items tagged with 'dl acetylsalicylic acid'

product image
Rapid Test

The OnSite Troponin I Combo Rapid Test is a lateral flow chromatographic immunoassay for the qualitative detection of cardiac Troponin I (cTnI) in human serum, plasma or whole blood at a level equal to or higher than 1 ng/mL. It can be performed within 15 minutes by minimally skilled personnel, and without the use of laboratory equipment. The OnSite Troponin I Combo Rapid Test is intended to be used by healthcare professionals as an aid in the diagnosis of acute myocardial infarction (AMI). Any use or interpretation of this preliminary test result must also rely on patient’s symptoms and the professional judgment of a physician. A more precise test method such as an instrument method must be used to confirm the test result obtained by this device. Normally the level of cTnI in the blood is very low. cTnI is released into the blood stream in forms of free cTnI and cTnI-C-T complex at 4-6 hours after myocardial cell damage. The elevated level of cTnI could be as high as 50 ng/mL during 60-80 hours after AMI and remains detectable for up to 10-14 days post AMI. Therefore, circulating cTnI is a specific and sensitive marker for AMI. Clinical performance: Relative Sensitivity: 95.8% (95% CI: 91.5-97.9%) compared to a reference CLIA Relative Specificity: 99.7% (95% CI: 98.8-99.9%) Analytical sensitivity: The detection limit of cTnI is 1.0 ng/mL or greater in serum, plasma or whole blood specimen Cross-reactivity: No cross reactivity with 10 µg/mL skeletal muscle TnI, 2,000 ng/mL cardiac muscle TnT, 20 µg/mL cardiac muscle Myosin Dose hook effect: No hook effect was observed for cTnI at concentrations up to 3,521 µg/mL Interference: No interference was seen with 20 mg/dl Acetaminophen, 20 mg/dl Acetylsalicylic acid, 10.5 g/dl Albumin, 20 mg/dl Ascorbic acid, 1,000 mg/dl Bilirubin, 20 mg/dl Caffeine, 800 mg/dl Cholesterol, 200 mg/dl Creatinine, 20 mg/dl Gentistic acid, 1,000 mg/dl Hemoglobin, 600 mg/dl Oxilic acid, 1,600 mg/dl Triglycerides Shelf life: 24 months Individually sealed foil pouches containing: One cassette device One desiccant Plastic droppers Sample diluent (REF SB-R3002, 5 mL/bottle) One package insert (instruction for use) CTK Products at a Glance Insert MedlinePlus: Troponin Test Poster

Send Message
product image
Rapid Test

The OnSite Chikungunya IgM Combo Rapid Test is a lateral flow chromatographic immunoassay for the qualitative detection of IgM anti-chikungunya (CHIK) virus in human serum, plasma or whole blood. Uses serum, plasma or whole blood specimen Utilizes recombinant antigen derived from the CHIK structure protein IgM immunoassay is the most practical lab method Distinguish from dengue infection which presents with similar symptoms Clinical performance: Sensitivity: 90.4% Specificity: 98.0% comparing to a commercial ELISA Cross-Reactivity: no cross-reactivity found on 10-40 specimens from the 14 disease states and special conditions, such as dengue, Zika, malaria, HIV, TB, HAV, pregnant woman and others No interference with some common substances, such as Acetominophen (20 mg/dL), Heparin (3000 U/L), Ascorbic acid (20 mg/dL), Human IgG (1000 mg/dL), Bilirubin (20 mg/dL), Glucose (55 mmol/L), Creatinine (442 μmol/L), Salicylic acid (4.34 mmol/L), EDTA (3.4 μmol/L), Sodium citrate (3.8%) Individually sealed foil pouches containing: One cassette device One desiccant Capillary tubes (5 μL) Sample diluent (REF SB-R0066, 5 mL/bottle) One package insert (instruction for use) CTK Products at a Glance Inserts U.S. CDC Chikungunya Virus Homepage: (Transmission, Prevention, etc.) WHO: Chikungunya Virus Fact Sheets

Send Message
product image
Rapid Test

The OnSite Leptospira IgG/IgM Combo Rapid Test is a lateral flow chromatographic immunoassay that can be performed within 15-20 minutes by minimally skilled personnel, and without the use of laboratory equipment. This test is intended to be used for the simultaneous detection and differentiation of IgG and IgM antibodies to Leptospira interrogans (L. interrogans) in human serum, plasma or whole blood. It is intended to be used as a screening test by professionals, and provides a preliminary test result to aid in the diagnosis of infection with L. interrogans. Any interpretation or use of this test result must also rely on other clinical findings as well as on the professional judgment of health care providers. Recommended for use: Any person presenting with clinical signs or symptoms consistent with acute infection with interrogans including: high fever, headache, chills, muscle aches, vomiting, jaundice, red eyes, abdominal pain, diarrhea, skin rash After exposure to a known contaminated source Accuracy: 100% specificity and 100% sensitivity in comparison with a reference rapid test on the market Cross Reactivity: No false positive results were observed on specimens from TP, HIV, Dengue, TB, Typhoid Ab , HBsAg, HCV Ab, HEV Ab, H.P Ab, HAV, HCG, RF, ANA, HAMA Interference: No interference were seen with substances: Salicylic acid: 4.34 mmol/L; Glucose: 55 mmol/L; Sodium citrate: 3.8 %; Heparin: 3,000 U/L; Creatinine: 442 μmol/L; Bilirubin: 20 mg/dL; EDTA: 3.4 μmol/L; Hemoglobin: 2g/L; Human IgG: 1000 mg/dL; AlbuminL 60 g/L Shelf life: 24 month Individually sealed foil pouches containing: One cassette device One desiccant 5 μL capillary tubes Sample diluent (REF SB-R0101, 5 mL/bottle) One package insert (instruction for use) CTK Products at a Glance Inserts U.S. CDC Leptospira Homepage: About Leptospira WHO: Leptospirosis Fact Sheets

Send Message
product image
Rapid Test

The OnSite Duo HSV-1/2 IgG/IgM Rapid Test is a lateral flow chromatographic immunoassay for qualitative detection and differentiation of antibodies (IgG and IgM) to herpes simplex virus 1 (HSV-1) and herpes simplex virus 2 (HSV-2) in human serum, plasma or whole blood. This test can be performed in 10 minutes by minimally skilled personnel without the use of laboratory equipment. This test is intended to be used by professionals as a screening test and provides a preliminary test result to aid in the diagnosis of infection with HSV-1 and/or HSV-2. The OnSite Duo HSV-1/2 IgG/IgM Rapid Test uses HSV-1 glycoprotein G1 and HSV-2 glycoprotein G2 for the specific detection and differentiation of IgG and IgM antibodies to HSV-1 and HSV-2 in serum, plasma and whole blood. An HSV-1 and/or HSV-2 IgM positive result indicates an active infection, which may be primary or recurrent. An HSV-1 and/or HSV-2 IgG positive result indicates a recent or past infection. However, a negative test result does not preclude the possibility of infection with HSV-1 and/or HSV-2. Any interpretation or use of this preliminary test result must also rely on other clinical findings as well as on the professional judgment of health care providers. Alternative test method(s) should be considered to confirm the test result obtained by this device. Clinical accuracy: 90.6% sensitivity and 91.4% specificity for anti-HSV-1 IgG detection 93.8% sensitivity and 96.0% specificity for anti-HSV-2 IgG detection 85.0% overall agreement for anti-HSV-1 IgM detection comparing to commercial ELISA 100% overall agreement for anti-HSV-2 IgM detection comparing to BBI Panel (PTH202) Positive rate on random clinical specimens:8% for IgG anti-HSV-1 and 4.9% for IgM anti-HSV-1 (n=10,000); 4.6% for anti-HSV-2 IgG and 1.7% for anti-HSV-2 IgM Cross reactivity: no cross reactivity with the following disease states or special conditions, respectively: palladium, H. pylori, Dengue, Malaria, Typhoid, Toxoplasma, Rubella, CMV, hCG, TB, HAV, HBV, HCV, HEV, HIV, ANA, HAMA, RF (up to 1,000 IU/mL) Interference: No interference was seen with Albumin 60 g/L , Hemoglobin 2 g/L, Bilirubin 20 mg/dL, Heparin 3,000 U/L, Creatinine 442 µmol/L, Salicylic acid 4.24 mmol/L, EDTA 3.4 µmol/L, Sodium citrate 8%, Glucose 55 mmol/L Shelf life: 24 months Individually sealed foil pouches containing: One cassette device One desiccant Capillary tubes (10 µL) Sample diluent (REF SB-R0203, 5 mL/bottle) Package insert (instruction for use) Individually sealed foil pouches containing: One cassette device One desiccant Capillary tubes (10 µL) Sample diluent (REF SB-R0203, 5 mL/bottle) Package insert (instruction for use)

Send Message
product image
Distance Meter Digital

Product Details: Warranty 6 Months Material Glass Temperature 15.6oC equal to 60oF Standard ASTM We are the Leading supplying of Hydrometer Device of superior quality range. Hydrometers is a device to measure relative density of liquids such as Grease, oil etc. Components used in a hydrometer are glass frame, cylindrical stem and bulb floating in the mercury fluid. To test the density of a liquid, we use a long glass jar. The jar is filled with liquid and hydrometer is floated inside the fluid. The liquid surface touches the stem of hydrometer at specific point, which indicates specific gravity of that fluid. Specifications: Sikes Hydrometer at 51ºF, Zeal England: Range: 0/20 A 0/20 20/40 40/60 60/80 80/100 Alcohol meter (V / V, Volume By Volume) Zeal U.K. at 15.6ºC Range: 0-20, 20-40, 40-60, 60-80, & 80-100 JAWA (Brix) Hydrometers with work Certificate Germany Range: No.1 - 2 to 13 No.2 - 13 to 21 No.3 - 19 to 27 Heavy Liquid Hydrometers, Germany Sp.Gr.1000/2000 & BE 0/70 Light Liquid Hydrometers, Germany Sp.Gr. 700/1000 & BE 10/70 Heavy Liquid Hydrometers, 305 mm Long, Range - 1.000 / 2.000 & 0/70 Baume Light Liquid Hydrometers, 230 mm Long, Range : 700 / 1.000 Baume Hydrometers, Germany at 20ºC Range: 0/10, 10/20, 20/30, 0/20, 0/30, 0/40, 0/50, 30/40 & 40/50 Baume Hydrometers, Digital, Atago, Japan Model PAL-84S, Range : 0.0 - 210 Twaddle Hydrometers German at 60ºF, No. 1, 2, 3, 4, 5, & 6 Twaddle Hydrometer Zeal England at 84ºF, No. 1, 2, 3 & 6 Twaddle Hydrometer Zeal England at 84ºF, No. 4 & 5 Brix Hydrometer w/o Thermometer Germany at 20ºC Range: 0/10, 10/20 & 20/30 Brix Hydrometer w/o Thermometer Germany at 27.5ºC Range: 0/10, 10/20, 20/30, 30/40, 0/30, 30/60 & 60/90 Brix Hydrometer with Thermometer Germany at 27.5ºC & 20ºC Range: 0/10, 10/20, 20/30, 0/30, 30/60 & 60/90 Brix Hydrometer with Thermometer Germany GDR, German at 27.5ºC & 20ºC Range: 0/10, 10/20 & 20/30 Brix Hydrometer with Thermometer German with NPL Certificate Brix Hydrometer, Sugar Percent Temp. 27.5ºC Made in West Germany Specific Gravity Hydrometers, Germany at 20ºC 600/700, 700/800, 800/900 & 900/1000 & 800/10001000/1100, 1100/1200, 1200/1300, 1300/14001400/1500, 1500/1600, 1600/1700, 1700/18001000/1200, 1200/1400, 1400/1600, 1600/1800, 1800/2000 800/1000 GDR German Make Sikes Table Book Indian Soil Hydrometer, Zeal England, ASTM 152 H Range: 5 to 60 gm / ltr, Temp: 68ºF

Send Message
product image
Clinical Chemistry

Ready to use liquid stable reagents. Pack sizes cater to specific customer needs. High quality reagents manufactured to international standards. Categories: Clinical Chemistry, Reagents Description Reagents Technical Information KITS Albumin Alkaline Phosphatase AST/SGOT Bilirubin Direct Calcium CK-NAC Creatinine GGT LDL Direct Magnesium Total Protein Uric Acid ALT/SGPT Amylase Bilirubin Total Bilirubin Total & Direct Cholesterol CK-MB Glucose HDL Direct LDH-L Phosphorus Triglycerides Urea Kinetic (Rate BUN) Lipase information every single reagents has a diffrent price 1 pack single price.

Send Message
product image
Rapid Test

Buy Dengue NS1 Antigen test (Pack of 5 test) from Accurex. This NS1 Antigen Rapid test contains: A Test device in aluminum pouch with a desiccant, Disposable dropper & Pack Insert. Dengue NS1 antigen test utilizes the human serum / plasma followed by solid-phase immuno-chromatographic technology for the qualitative detection of dengue virus NS1 antigen. Dengue NS1 Antigen kit is for professional use and only for the initial screening test & reactive samples should be confirmed by a supplemental assay such as nucleic acid test & other immunological assays. EXPLANATION OF THE TEST Dengue NS1 antigen test utilizes the human serum / plasma followed by solid-phase immuno-chromatographic technology for the qualitative detection of dengue virus NS1 antigen. The membrane strip of the kit contains pre-coated anti-dengue NS1 monoclonal antibody on the test band region (T), and goat anti-mouse IgG is pre-coated on the control band region (C). During testing, if the sample containing dengue NS1 Ag, the complex of the antibody-dengueNS1 Ag-gold conjugate moves laterally on the membrane by capillary action. In this case, the colored band will appear on the membrane in test line (T). Control line (C) should always appear if the test procedure is performed properly Safety Information 1. For in-vitro diagnostic use only. Do not re-use the test device. 2. The instruction must be followed exactly to get accurate results. 3. Anyone performing an assay with this product must be trained in its use and must be experienced in laboratory procedures. 4. Do not eat or smoke while handling specimens. 5. Wear protective gloves while handling specimens. Wash hands thoroughly afterwards. 6. Avoid splashing or aerosol formation. 7. Clean up spills thoroughly using an appropriate disinfectant. 8. Decontaminate and dispose of all specimens, reaction waste, in a biohazard container. 9. Do not mix and interchange different specimen. 10. The presence of humidity may decrease the stability of the tests. Thus, carry out the test immediately after removing the device from the foil pouch. 11. Do not use it beyond the expiration date. Direction for Use 1. Place all specimens, test device and solution. Allow them to room temperature prior to testing (15~30 min.) 2. Please perform the test immediately after removing the device from the foil pouch. 3. With a disposable dropper, load 2-3 drops (50 to 75µl) of specimen into the sample well (S) in the test device. 4. Interpret the test results between 15~20 minutes. Do not read the results after 20 minutes. Other Info 1) Dengue NS1 Antigen test should be stored between 4~30 ºC 2) Expiration date of this kit is 24 months after its manufacture date. LIMITATIONS OF THE TEST Dengue NS1 antigen test is designed for primary screening test of dengue virus NS1 antigen. Although this can provide fast and easy way to get a result, the testing do not completely exclude the possibility of false positive or negative result caused by various factor. So, refer to the result of the kit, please make a final decision with clinical manifestation, other test results and doctor’s view collectively.

Send Message
product image
Clinical Chemistry

utozyme Albumin 300 Diagnostic Reagent from Accurex. Albumin 300 is used for determination of albumin in serum or plasma based on BCG method. Autozyme Albumin is a single reagent system which is ready to use, Albumin is linear up to 6 gm% & can be determined in 1 minute at room temperature. Serum albumin in the presence of Bromocresol-green under acidic condition forms a green coloured complex. Albumin normal range is 3.4 to 5.4 g/dL (34 to 54 g/L). About Autozyme Albumin is a reagent set for determination of albumin in serum or plasma based on BCG method Autozyme Albumin is a single reagent system, ready to use. Autozyme Albumin is linear up to 6 gm% Albumin can be determined in 1 minute at room temperature The shelf-life of Autozyme Albumin is 18 months Pack Size : 2 x 50 ml Principle Serum albumin in the presence of Bromocresol-green under acidic condition forms a green coloured complex, The absorbance of this complex is proportional to the albumin concentration in serum or plasma. Quality Control To ensure adequate quality control, it is recommended that each batch should include a normal and an abnormal commercial reference control serum,. it should be realized that the use of quality control material checks both instrument and reagent functions together. Factors which might affect the performance of this test include proper instrument function, cleanliness of glassware and accuracy of pipetting. Other Details The reagents are for in vitro diagnostic use. BCG reagent and standard should be stored at temperature indicated on the bottle label.

Send Message

Still searching for
dl acetylsalicylic acid?