Jaipur
+918529833535

'differentiates'

Items tagged with 'differentiates'

product image
Rapid Test

The OnSite HSV-1 IgG/IgM Rapid Test is a lateral flow chromatographic immunoassay for the qualitative detection and differentiation of antibodies (IgG and IgM) to herpes simplex virus 1 (HSV-1) in human serum, plasma or whole blood. Type-specific detection by utilizing glycoprotein G1. Single test that detects and differentiates IgG and IgM anti-HSV-1. High confidence as test is in agreement with market leading ELISA test: 90.7% IgG; 85.0% IgM. Flexible specimen types including serum, plasma, or whole blood which allows testing at any time without special specimen preparation. Small sample volume (10 µL) enables multiple testing on the same specimen without having to re-draw the patient. Initial treatment action can begin during the patient’s visit as test results are available in 10 minutes. Easily transported, and can be stored for 24 months, 2-30oC. Individually sealed foil pouches containing: One cassette device One desiccant Capillary tubes (10 µL) Sample diluent (REF SB-R0203, 5 mL/bottle) Package insert (instruction for use) CTK Products at a Glance HSV-1 & HSV-2 Flyer Insert U.S. CDC HSV Homepage: Genital Herpes Fact Sheets WHO: Herpes Simplex Virus Fact Sheets

Send Message
product image
Rapid Test

The OnSite Typhoid IgG/IgM Combo Rapid Test is a lateral flow immunoassay for the detection and differentiation of IgG and IgM anti-Salmonella typhi (S. typhi) and paratyphi in human serum, plasma or whole blood. Utilizes O antigen and H antigen from both typhi and paratyphi serovars to maximize sensitivity Differentiates between IgG and IgM to determine stage of infection One step procedure minimizes operator error due to sample preparation Test result within 15 minutes allows medical professionals to take immediate action High level of reproducibility Test kits can be used and stored in a wide range of temperatures Individually sealed foil pouches containing: One cassette device One desiccant Plastic droppers Sample Diluent (REF SB-R0161, 5 mL/bottle) Package insert (instruction for use) CTK Products at a Glance Flyer Inserts U.S. CDC Typhoid Homepage: About Typhoid WHO: Health Topic for Typhoid

Send Message
product image
Rapid Test

Buy AccuTest Typhoid IgG/IgM Rapid Card Test (5 Tests) Online from Accurex. The Typhoid IgG/IgM Rapid Test is used for detection & differentiation of anti-Salmonella typhi (S. typhi) IgG and IgM in human whole blood / serum / plasma. This Typhoid test is used as a screening test and as an aid in the diagnosis of infection with S. typhi. Salmonella typhi bacteria causes typhoid Typhoid fever, typhoid symptoms symptoms are likely to develop gradually – appearing one to three weeks after exposure to the disease. There are various typhoid treatment & typhoid vaccine which can be opted after the detetction of Typhoid. Typhoid fever is caused by S. typhi, a Gram-negative bacterium. Worldwide an estimated 17 million cases and 600,000 associated deaths occur annually. Patients who are infected with HIV are at significantly increased risk of clinical infection with S. typhi. Evidence of H. pylori infection also presents an increased risk of acquiring typhoid fever. 1-5% of patients become chronic carrier harboring S. typhi in the gall bladder. The clinical diagnosis of typhoid fever depends on the isolation of S. typhi from blood, bone marrow or a specific anatomic lesion. In the facilities that can not afford to perform this complicated and time-consuming procedure, Filix-Widal test is used to facilitate the diagnosis. However, many limitations lead to difficulties in the interpretation of the Widal test. In contrast, the Typhoid IgG/IgM Rapid Test is a simple and rapid laboratory test. The test simultaneously detects and differentiates the IgG and the IgM antibodies to S. typhi specific antigen thus to aid in the determination of current or previous exposure to the S. typhi. PRINCIPLE The Typhoid IgG/IgM Rapid Test is a lateral flow immunochromatographic assay. The test cassette consists of: 1) a pink-purple colored conjugate pad containing recombinant S. typhi H antigen and O antigen conjugated with colloid gold (Typhoid conjugates) and rabbit IgG-gold conjugates, 2) a nitrocellulose membrane strip containing two test region (Test line M and G) and a control region (control line). The test line ‘M’ is pre-coated with monoclonal anti-human IgM for the detection of IgM anti-S. typhi, test line ‘G’ is pre-coated with monoclonal anti-human IgG for the detection of IgG anti-S. typhi , and the C band is pre-coated with goat anti rabbit IgG. When an adequate volume of test specimen is dispensed into the sample well of the cassette, the test specimen migrates by capillary action across the test cassette. Anti-S. typhi IgM if present in the patient specimen will bind to the Typhoid conjugates. The immunocomplex is then captured on the membrane by the pre-coated anti-human IgM antibody at test region ‘M’, forming a pink-purple line at ‘M’ region, indicating a S. typhi IgM positive test result. Anti-S. typhi IgG if present in the patient specimen will bind to the Typhoid conjugates. The immunocomplex is then captured by the pre-coated reagents on the membrane, forming a pink-purple line at test region ‘G’, indicating a S. typhi IgG positive test result. Absence of any pink-purple line at test region (M and G) suggests a negative result. The test contains an internal control (control line) which should exhibit a pink-purple line of the immunocomplex of goat anti rabbit IgG/rabbit IgG-gold conjugate regardless of the color development on any of the test region. Otherwise, the test result is invalid and the specimen must be retested with another device. PRECAUTION 1. This package insert must be read completely before performing the test. Failure to follow the insert gives inaccurate test results. 2. Do not open the sealed pouch, unless ready to conduct the assay. 3. Do not use expired devices. 4. Bring all reagents to room temperature (15°C-30°C) before use. 5. Do not use the components in any other type of test kit as a substitute for the components in this kit. 6. Do not use hemolized blood specimen for testing. Wear protective clothing and disposable gloves while handling the kit reagents and clinical specimens. Wash hands thoroughly after performing the test. 7. Users of this test should follow the US CDC Universal Precautions for prevention of transmission of HIV, HBV and other blood-borne pathogens. 8. Do not smoke, drink, or eat in areas where specimens or kit reagents are being handled. 9. Dispose of all specimens and materials used to perform the test as biohazardous waste. 10. Handle the Negative and Positive Control in the same manner as patient specimens. 11. The testing results should be read within 15 minutes after a specimen is applied to the sample well or sample pad of the device. Read result after 15 minutes may give erroneous results. 12. Do not perform the test in a room with strong air flow, ie. an electric fan or strong air-conditioning. Other Info STORAGE AND STABILITY Typhoid IgG/IgM test card should be stored at 4-40°C. The card may be stored at room temperature but not exceeding 40°C in the original sealed pouch. The shelf life or expiry of the card is printed on Pouch as well as carton label. The test kit should be kept away from direct sunlight, moisture and heat.

Send Message
product image
Critical Care

Product Description: Medica Corporation’s EasyLyte® analyzer is a completely automated, microprocessor-controlled electrolyte system that uses ISE (Ion Selective Electrode) technology to make electrolyte measurements. The EasyLyte measures combinations of Na+, K+, in whole blood, serum, plasma, or urine. EasyLyte incorporates state-of-the-art electronics and an innovative ergonomic design that differentiates it significantly from competitors. The analyzer also stores quality-control data that is easily accessible. Patient histories are immediately retrievable for evaluation. EasyLyte analyzers combine simple yes/no prompted operation, low maintenance, and high reliability into one economical design. Product Features: EasyLyte is Easy to Use, Easy to Operate, Easy to Maintain The entire menu is driven by 2 simple buttons Results are displayed on LCD screen as well as printouts EasyLyte does 2 point as well as 1 point calibration Facility to analyze different type of samples: whole blood, serum, plasma ,urine samples EasyLyte has capillary and syringe sampling facility EasyLyte has auto probe wiping facility Analysis of electrolytes is done using 100ul of blood and 400ul of diluted urine Rate of analysis 55 secs per sample Analyzer is capable of storing 128 patients data with trilevel QC results Analyzer has modular plug in reagent pack system EasyLyte has facility for auto calibrations with a programmed interval of 4 hrs and also calibration on demand Analyzer has facility to upgrade to a walk away Electrolyte station by use of Auto Sampler It has a built in thermal printer and a RS 232 port for interfacing Product Applications: Sodium - Na, Potassium - K CLIA Classification: Moderate Complexity Sample Type: Whole Blood, Serum, Plasma or Urine Sample Size: 100 µL Whole Blood, Serum, Plasma, 60 µL capillary or 400 µL diluted (1:10) Urine Method: Direct measurement by Ion Selective Electrode (ISE) Measurement Range: Blood Urine Na+: 20 – 200 mmol/L Na+: 25 – 1000 mmol/L K+: 0.2 – 40 mmol/L K+: 1.0 – 500 mmol/L Cl-: 25 – 200 mmol/L Cl-: 25 – 500 mmol/L Li+: 0.2 – 5.0 mmol/L Ca++: 0.1 – 6.0 mmol/L pH: 6.0 - 8.0 Units Display Resolution: Na+: 0.1 mmol/L K+: 0.01 mmol/L Cl- : 0.1 mmol/L Li+: 0.01 mmol/L Ca++: 0.01 mmol/L pH: 0.005 units Test Time: Na/K Na/K/Cl Na/K/Li Na/K/Cl/Ca Analysis time (blood) 55 sec 55 sec 55 sec 60 sec Urine mode Yes Yes Yes No Analysis time (urine) 90 sec 90 sec 90 sec N/A EasySampler Yes Yes Yes No Capillary Samples Yes Yes Yes No Data Storage: Patient Results: up to 128 samples QC Results: up to 20 each Normal, Low, and High Calibration: Automatic or On-Demand Output: 128 x 64 pixel graphic display 24 column thermal printer Serial port (RS-232), EasySampler port Ambient Conditions: 15–32oC (60–90oF), <85% humidity Power: 100-240 VAC 50/60 Hz, 0.8A Size & Weight: 9.5”W x 16.5”H x 8.0”D (24 cm W x 42 cm H x 20 cm D) 13 lbs. (5.8 kg) Reagents used with this 'EasyLyte' CLIA Classification: Moderate Complexity Sample Type: Whole Blood, Serum, Plasma or Urine Sample Size: 100 µL Whole Blood, Serum, Plasma, 60 µL capillary or 400 µL diluted (1:10) Urine Method: Direct measurement by Ion Selective Electrode (ISE) Measurement Range: Blood Urine Na+: 20 – 200 mmol/L Na+: 25 – 1000 mmol/L K+: 0.2 – 40 mmol/L K+: 1.0 – 500 mmol/L Cl-: 25 – 200 mmol/L Cl-: 25 – 500 mmol/L Li+: 0.2 – 5.0 mmol/L Ca++: 0.1 – 6.0 mmol/L pH: 6.0 - 8.0 Units Display Resolution: Na+: 0.1 mmol/L K+: 0.01 mmol/L Cl- : 0.1 mmol/L Li+: 0.01 mmol/L Ca++: 0.01 mmol/L pH: 0.005 units Test Time: Na/K Na/K/Cl Na/K/Li Na/K/Cl/Ca Analysis time (blood) 55 sec 55 sec 55 sec 60 sec Urine mode Yes Yes Yes No Analysis time (urine) 90 sec 90 sec 90 sec N/A EasySampler Yes Yes Yes No Capillary Samples Yes Yes Yes No Data Storage: Patient Results: up to 128 samples QC Results: up to 20 each Normal, Low, and High Calibration: Automatic or On-Demand Output: 128 x 64 pixel graphic display 24 column thermal printer Serial port (RS-232), EasySampler port Ambient Conditions: 15–32oC (60–90oF), <85% humidity Power: 100-240 VAC 50/60 Hz, 0.8A Size & Weight: 9.5”W x 16.5”H x 8.0”D (24 cm W x 42 cm H x 20 cm D) 13 lbs. (5.8 kg)

Send Message

Still searching for
differentiates?