Jaipur
+918529833535

'different applications'

Items tagged with 'different applications'

product image
Instruments

The NB350 neonatal noninvasive ventilator is specially designed for neonatal ventilation, equipped with comprehensive NIV modes to provide reliable non-invasive respiratory support to meet the various needs of neonatal respiratory management. EasySync™ Technology The patented EasySync™ technology analyzes multi-channel parameters including gas flow and pressure without additional sensors, enabling accurate detection of spontaneous breath and improving synchrony in SNIPPV. The EasySync™ technology leads to a good synchronization performance comparable to electrical activity of the diaphragm (Edi). IOC (Intelligent Oxygen Control) The oxygen saturation of neonates tends to fluctuate, requiring caregivers to frequently adjust ventilator’s FiO2 settings. IOC (Intelligent Oxygen Control) achieves a closed-loop FiO2-SpO2 control by maintaining the patient’s SpO2 within the predetermined range, which reduces the workload of caregivers and improves patient safety. Integrated SpO2 monitoring for neonates in real time.1 Automatically adjust FiO2 setting by adaptive algorithm.2 Steadily maintain the SpO2 of neonates within the preset target range. Comfortable and Reliable Patient-interface The specialized patient-interface for the NB350 comes with a variety of sizes to fit for different clinical applications and patients. The ergonomic design with soft, skin-friendly material fully enhances the comfort of neonates throughout therapies. Bonnet/Headgear The bonnet/headgear integrate a fixings lot (seat) for pressure generator to avoid misposition and disconnection of patient-interface. Skin-friendly and breathable bonnet/headgear. Durable headgear hook-and-loop fastener allows easy and quick re-adjustment of the patient-interface. Infant Jet™ Pressure Generator Adjustable nasal prong/nasal mask positioning to adapt different facial orientations. Specifically designed to facilitate Coanda effect, significantly reducing respiratory resistance. Related Articles

Send Message
product image
Hematology

BC-6800 Today, laboratories not only need more reliable routine CBC plus 5-part diff WBC testing by way of high processing speed, but are also looking for options that extend the analyzer's output in form of Reticulocytes, Nucleated RBCs, Fluorescent Platelet counts etc. for wider clinical application and research. On the other hand, they are restricted by limited budgets. BC-6800 can help to meet all these needs just perfectly and even exceed the expectations. Additional parameters for further clinical applications IMG(#,%) parameters provide information about immature granulocyte, including promyelocytes, myelocytes and metamyelocytes. HFC*(#,%) parameters represent high fluorescent cell population, such as blasts and atypical lymphocytes. RET(#,%) extend valuable help in the differential diagnosis and/or therapeutic monitoring of anemias. IRF is parameter concerning immature reticulocytes, which can assist in early diagnosis of anemia and monitoring the bone marrow response to therapy. InR*(#,‰) are parameters regarding infected red blood cell. The red blood cells may infected by plasmodium, which can cause malaria. * means research parameters SF Cube Technology SF Cube is a pathbreaking technology for reliable blood cell analysis, including WBC differential, Reticulocytes and NRBC with efficient flagging. After reaction with proprietory reagents, the targeted blood cells undergo 3D analysis using information from scatter of laser light at two angles and fluorescence signals. The 3D scattergram builds the power to better identify and differentiate blood cell populations, especially to reveal abnormal cell population undetected by other techniques. Minimizing interference to ensure more accurate results NRBCs are counted in a dedicated channel by SF cube method, which automatically corrects total WBC count and 5-part Diff results when NRBCs are detected. The Focusing Flow-DC method minimizes the interference traditionally encountered in DC technology to produce near gaussian histograms. PLT-O result avoids the interference from microcytic and fragmented RBCs, large platelets and/or platelet clumps by fluorescent stain, and enhances the results accuracy and sensitivity. High automation to minimize the workload Throughput for 125 tests/hour, autoloader for 100 sample tubes capacity Bi-directional LIS with HL7 or ASTM communication protocol Customizable re-exam rules allow users to define their re-exam criterion according to lab’s practice

Send Message
product image
Hematology

Product Description AutoCell Plus 3 Part WBC Differential Automated Hematology Analyzer Large Touch Screen Display Easy analysis of patient data on single screen ensuring efficient work-flow 10.4" color touch-screen Data + Hitogram Based Result 20 parameters numerical data 8 3 histo grams Results are displayed as group of "data + histogram" for each parameter enabling easier correlation. Dual Sample Mode Ft Small Sample Volume Just 9 pL whole blood required for test - Very useful for pediatric & geriatric patients where sample collection may be very difficult 20 pL Pre-dilution mode - Automatic dilution in case of capillary sample by analyser which minimizes manual dilution-related errors. Other Important Features: Direct access Clog removal key saves time for user by not needing to come back to main menu. Comprehensive built-in QC program for up to 10 lots with X -R, X B, X D CV value. Flexibility of dual calibration (Automatic 8 Manual calibration)allows user to calibrate the instrument according to his need to ensure the accuracy of measurements (results) Dual chamber for WBC Et RBC makes faster test results with more accurate & avoids cross-contamination Reagent depletion alarm for Lyse, Cleanser and Diluent, as optional function (Liquid Sensors) 10, 000 test results with histogram to meet all requirements Auto background measurement during start-up for ensuring trouble-free operation Internal thermal printer or facility to connect optional external printer RS232 interface & PC connectivity

Send Message
product image
Hemostasis Analyzer

Product Description: It’s a modern and advanced analyzer in Hemostasis. This single channel coagulation analyzer redefines the benefits in its class Erba. ECL 105 can perform PT, APTT, Fibrinogen, Thrombin Time, All Factiors, Lupus and DDimer. Product Features: Clotting Tests such as PT, aPTT, Fibrinogen, Thrombin time, Factors, Lupus anticoagulant performed using Light scatter principle Tests like D Dimer performed using Immuno-turbidimetry principle Interactive touch screen interface Clotting Graph provides details of the clotting testCuvette and reagent management software Twelve levels of QC with Levy-Jennings Plot- Identifies random and systematic errors Temperature stability at 37 degree C to perform the tests. Low Reagent Consumption USB Connectivity CE mark Product Applications: ECL 105 has uses in various routine IVD labs for doing routine PT and aPTT It has application in Blood Banks for Quality Control of Fibrinogen and Factor VIII It is used as Standby to bigger systems, in accredited centres It is used in Research Facilities to perform PT and aPTT on animal samples such as rat, mouse, rabbit, hamsters etc Key Specifications: Single channel semi-automated hemostasis system It can analyze 1 test at a time Sample id can be 14 digits alphanumeric, with progressive id or custom id options It is also possible to have a second position of assay preparation/incubation during the analysis of the current one, using preparation line option Optically detects and automatically moves to the next assay steps and auto starts the measurements Tests principles: Clotting (scattered light at 640nm) Immuno-turbidimetric (turbidimetry at 800nm) Dimensions / Weight: Dimension : 216 x 205 x 75 mm Weight : ~1 kg Environmental requirements: Operating Temperature : 17-32°C Humidity: Max. 80% Relative Humidity, non-condensing Power: Power Supply : 100-240 VAC and 50/60 Hz Power Consumption : 45 Watts In-Rush Power : 150 VA or less Calibrations: Up to 6 calibration levels per assay Storage of the active calibration curve Quality Controls: Up to 12 different control total can be assigned to any given assay Automatic Levey-Jennings plotting Automatic statistics calculation Storage of Quality Control results Stored Results: Independent storage allocation in the instrument memory for Quality Control (QC) and patient determinations Up to 1000 results for QC determinations Up to 1000 results for patients New results automatically replace the oldest results of the appropriate category past the maximum storage allowance Reaction curves are exclusively stored on the external USB pen drive. Regular backup and file purging is recommended from the USB pen drive to insure rapid operations. USB pen drive, FAT32 formatted

Send Message
product image
Hemostasis Analyzer

Product Description: It’s an advanced analyzer for Complete Hemostasis. This four channel coagulation analyzer redefines the benefits in its class. Erba ECL 412, can perform PT, APTT, Fibrinogen, Thrombin Time , All Factors, Lupus , Protein S, Protein C , Antithrombin III and DDimer. Product Features: Clotting Tests such as PT, aPTT, Fibrinogen, Thrombin time, Factors, Lupus anticoagulant, Protein S performed using Light scatter principle. Protein C, Antithrombin III done by Chromogenic Principle Tests like D Dimer performed using Immuno-turbidimetry principle Interactive touch screen interface Clotting Graph provides details of the clotting test Cuvette and reagent management software Twelve levels of QC with Levy-Jennings Plot- Identifies random and systematic errors Temperature stability at 37 degree C to perform the tests Low Reagent Consumption USB Connectivity CE mark Product Applications: ECL 412 has uses in various routine IVD labs for doing routine PT and aPTT It has application in Blood Banks for Quality Control of Fibrinogen and Factor VIII It is used as Standby to bigger systems, in accredited centers It is used in Research Facilities to perform PT and aPTT on animal samples such as rat, mouse, rabbit, hamsters etc General Specifications: 4 channel semi-automated hemostasis instrument It can perform 4 simultaneous tests of the same parameter Sample id can be 14 digits alphanumeric, with progressive id or custom id options It is also possible to have a second row of assay preparation/incubation during the analysis of the current line, using preparation line option It can run assays in single or duplicate (programmable per assay) Optically detects and automatically moves to the next assay steps and auto starts the measurements Tests principles: Clotting (scattered light at 640nm) Chromogenic (colorimetry at 405nm) Immuno-turbidimetric (turbidimetry at 800nm) Dimensions / Weight: Dimension : 300 x 290 x 90 mm Weight : 3 kgs Environmental requirements: Operating Temperature : 17-32°C Humidity: Max. 80% Relative Humidity, non-condensing Power: Power Supply: 100-240 VAC and 50/60 Hz Power Consumption: 45 Watts In-Rush Power: 150VA or less Calibrations: Up to 6 calibration levels per assay Storage of the active calibration curve Quality Controls: Up to 12 different control names total can be assigned to any given assay Automatic Levey-Jennings plotting Automatic statistics calculation Storage of Quality Control results Stored results: Independent storage allocation in the instrument memory for Quality Control (QC) and patient determinations Up to 600 results for QC determinations (run in duplicate) Up to 900 results for patients (run in duplicate) New results automatically replace the oldest results of the appropriate category past the maximum storage allowance Reaction curves are exclusively stored on the external USB pendrive. Regular backup and file purging is recommended from the USB pendrive to insure rapid operations. (We recommend at least a monthly purge from a computer to back up and remove CH files) USB pendrive , FAT32 formatted

Send Message
product image
Critical Care

Product Description: Medica Corporation’s EasyLyte® analyzer is a completely automated, microprocessor-controlled electrolyte system that uses ISE (Ion Selective Electrode) technology to make electrolyte measurements. The EasyLyte measures combinations of Na+, K+, in whole blood, serum, plasma, or urine. EasyLyte incorporates state-of-the-art electronics and an innovative ergonomic design that differentiates it significantly from competitors. The analyzer also stores quality-control data that is easily accessible. Patient histories are immediately retrievable for evaluation. EasyLyte analyzers combine simple yes/no prompted operation, low maintenance, and high reliability into one economical design. Product Features: EasyLyte is Easy to Use, Easy to Operate, Easy to Maintain The entire menu is driven by 2 simple buttons Results are displayed on LCD screen as well as printouts EasyLyte does 2 point as well as 1 point calibration Facility to analyze different type of samples: whole blood, serum, plasma ,urine samples EasyLyte has capillary and syringe sampling facility EasyLyte has auto probe wiping facility Analysis of electrolytes is done using 100ul of blood and 400ul of diluted urine Rate of analysis 55 secs per sample Analyzer is capable of storing 128 patients data with trilevel QC results Analyzer has modular plug in reagent pack system EasyLyte has facility for auto calibrations with a programmed interval of 4 hrs and also calibration on demand Analyzer has facility to upgrade to a walk away Electrolyte station by use of Auto Sampler It has a built in thermal printer and a RS 232 port for interfacing Product Applications: Sodium - Na, Potassium - K CLIA Classification: Moderate Complexity Sample Type: Whole Blood, Serum, Plasma or Urine Sample Size: 100 µL Whole Blood, Serum, Plasma, 60 µL capillary or 400 µL diluted (1:10) Urine Method: Direct measurement by Ion Selective Electrode (ISE) Measurement Range: Blood Urine Na+: 20 – 200 mmol/L Na+: 25 – 1000 mmol/L K+: 0.2 – 40 mmol/L K+: 1.0 – 500 mmol/L Cl-: 25 – 200 mmol/L Cl-: 25 – 500 mmol/L Li+: 0.2 – 5.0 mmol/L Ca++: 0.1 – 6.0 mmol/L pH: 6.0 - 8.0 Units Display Resolution: Na+: 0.1 mmol/L K+: 0.01 mmol/L Cl- : 0.1 mmol/L Li+: 0.01 mmol/L Ca++: 0.01 mmol/L pH: 0.005 units Test Time: Na/K Na/K/Cl Na/K/Li Na/K/Cl/Ca Analysis time (blood) 55 sec 55 sec 55 sec 60 sec Urine mode Yes Yes Yes No Analysis time (urine) 90 sec 90 sec 90 sec N/A EasySampler Yes Yes Yes No Capillary Samples Yes Yes Yes No Data Storage: Patient Results: up to 128 samples QC Results: up to 20 each Normal, Low, and High Calibration: Automatic or On-Demand Output: 128 x 64 pixel graphic display 24 column thermal printer Serial port (RS-232), EasySampler port Ambient Conditions: 15–32oC (60–90oF), <85% humidity Power: 100-240 VAC 50/60 Hz, 0.8A Size & Weight: 9.5”W x 16.5”H x 8.0”D (24 cm W x 42 cm H x 20 cm D) 13 lbs. (5.8 kg) Reagents used with this 'EasyLyte' CLIA Classification: Moderate Complexity Sample Type: Whole Blood, Serum, Plasma or Urine Sample Size: 100 µL Whole Blood, Serum, Plasma, 60 µL capillary or 400 µL diluted (1:10) Urine Method: Direct measurement by Ion Selective Electrode (ISE) Measurement Range: Blood Urine Na+: 20 – 200 mmol/L Na+: 25 – 1000 mmol/L K+: 0.2 – 40 mmol/L K+: 1.0 – 500 mmol/L Cl-: 25 – 200 mmol/L Cl-: 25 – 500 mmol/L Li+: 0.2 – 5.0 mmol/L Ca++: 0.1 – 6.0 mmol/L pH: 6.0 - 8.0 Units Display Resolution: Na+: 0.1 mmol/L K+: 0.01 mmol/L Cl- : 0.1 mmol/L Li+: 0.01 mmol/L Ca++: 0.01 mmol/L pH: 0.005 units Test Time: Na/K Na/K/Cl Na/K/Li Na/K/Cl/Ca Analysis time (blood) 55 sec 55 sec 55 sec 60 sec Urine mode Yes Yes Yes No Analysis time (urine) 90 sec 90 sec 90 sec N/A EasySampler Yes Yes Yes No Capillary Samples Yes Yes Yes No Data Storage: Patient Results: up to 128 samples QC Results: up to 20 each Normal, Low, and High Calibration: Automatic or On-Demand Output: 128 x 64 pixel graphic display 24 column thermal printer Serial port (RS-232), EasySampler port Ambient Conditions: 15–32oC (60–90oF), <85% humidity Power: 100-240 VAC 50/60 Hz, 0.8A Size & Weight: 9.5”W x 16.5”H x 8.0”D (24 cm W x 42 cm H x 20 cm D) 13 lbs. (5.8 kg)

Send Message
product image
Clinical Chemistry

As the workload and test menu increase, simultaneous management of multiple ELISA protocols can become challenging. The LisaXL has been designed with an open architecture to meet various laboratory needs, providing all the tools necessary for hands-free ELISA processing, increasing the reliability and reproducibility, improving throughput, and freeing the laboratory staff from repetitive steps. LisaXL allows running multiple parameters for over 250 samples in a single batch. Equipped with dual probes and dedicated workstations, drastically improve ELISA workflows. LisaXL is a complete walkway system that minimizes manual errors while improving the accuracy and turnaround time for critical tests. LisaXL provides the flexibility to build and run virtually any ELISA assays. Product Features: Lisa XL is a true walk-away system for any laboratory needs. High Throughput with 6 plates, can process up to 576 tests. A dynamic scheduler ensures optimized system usage and turnaround times by processing 6 plates and up to 12 assays in each plate Onboard flexibility with sample capacity up to 272 and 20 interchangeable racks for reagents and samples. Dual probe processing ensures speed and reliability. "Zero" carryover with high-quality disposable tips. Six individually controlled incubators and shakers with variable temperature, time, and speed settings. Efficient washing with super sweep mode ensures minimum residual volume, with up to 6 different wash buffers. Easy to use touchscreen graphic user interface Product Applications: ELISA Physical Specifications 1 Dimensions Length 1375 mm 55" Height 845 mm 33" Width 850 mm 33.5" Weight 195 kgs (Approx) Power Supply Voltage 100 - 240 Volts Frequency 50 / 60Hz Power consumption 700 W General Specifications Assay per plate Up to 12 Number of ELISA plates Up to 6 Sample capacity Up to 272 Sample / Reagent capacity Total 20 racks Single rack holds 16 sample / reagent tubes Double rack holds 6 x 60 ml reagent bottles (can be used interchangeably) Tip / Dilution box Total 11 locations of 96 capacity each (can be used interchangeably) Reader Specifications Reading Range 0.0 - 3.5 O.D Reading Channels 8 Filter wheel 8 positions 405 nm, 450 nm, 492 nm, 620 nm std* 578 nm and 700 nm optional + 2 open Light source Halogen Lamp Reading mode Single, Dual, ORR Reading time < 1 min (for single filter) Linearity Up to 3.0 O.D (450 nm) Washer Specifications Manifold configuration 16 needles - 8 aspiration & 8 dispensing Precision < 5 % at 300 μl Wash cycle Programmable Residual volume < 5 μl / well Soak time Programmable Washer buffer capacity 6 × 2.25 L Waste water container 1 × 20 L Incubator Specifications Number of incubators Up to 6 Temperature range RT + 5°C up to 50°C Temperature stability ± 1°C Incubation time Programmable Time to set temperature < 6 min Shaking 200 to 800 RPM Shaking Method Orbital Pipetting Specifications Number of probes 2 Tips 300 µl / 1000 µl, Auto / Manual selected Multi-dispensing (Reagent) Minimum volume 4 μl Serum dispensing time < 14 min Reagent dispensing time < 5 min Sample mixing Yes (Automatic) Precision Sample & Reagent Sample Dispensing with 300 µl tip: 3% above 10 µl ± 0.5 µl for 10 µl & less Reagent Dispensing with 300 µl tip: 3% for 25 µl & above Reagent Dispensing with 1ml tip: 5% for 75 µl & above" Process Security Liquid level sensing Well fill verification Clot detection Onboard sample identification Onboard reagent identification Strip verification Buffer sensing Alarms Software Operating System Windows 10 (Embedded) LIS interface Bi-directional, Serial / TCPIP USB Port Graphic load interface Graphical work list Data processing Quantitative, Semi-Quantitative & Qualitative Multi password access Ability to archive data Computer (Base configuration considered, higher configuration can be considered for upgrade after testing) Intel Core i3, 4 GB RAM, 1 TB hard disk Monitor 22" Full HD touch screen

Send Message
product image
Rapid Test

Intended Use Dengue Day 1 Test is a rapid solid phase immuno-chromatographic test for the qualitative detection of Dengue NS1 Antigen and differential detection of IgM and IgG antibodies to Dengue virus in Human serum/plasma. This test is for in vitro diagnostic use only and is intended as an aid in the earlier diagnosis of Dengue infection & presumptive diagnosis between primary and secondary Dengue infection. Salient Features First line testing kit for detecting dengue infection from day 1 using NS1 Antigen & differential detection of IgM & IgG Antibodies. Diagnosis of both Primary & Secondary Infection. Detection of all the 4 Dengue serotypes (DEN-1, DEN-2, DEN-3 and DEN-4). Highly Sensitive & Highly Specific Long shelf life: 30 months at 2-30°C. Convenient pack sizes: 10 Tests, 30 Tests & 50 Tests.

Send Message

Still searching for
different applications?