Jaipur
+918529833535

'dic'

Items tagged with 'dic'

product image
Clinical Chemistry

HyPort B30 With the higher requirement of the healthcare, and continuing focus on the efficient clinical workflow, the advanced medical technology is always demanded from the patients and hospital. While some hospitals have limited space and budget, they search for a simple pendant solution to enhance the work efficiency and better care for the patient. Mindray HyPort B30 provides a simple, compact and cost-effective design for Anesthesia Pendant and Surgical Pendant in OR and ICU Pendant to meet this requirement. Less space needed with slimmer column design Easy to handle for nurse after reducing pendant weight Hygienic surface with anti-bacteria coating Built-in rails for accessories and no exposed screws

Send Message
product image
Clinical Chemistry

With the built-in oxygen concentration monitoring system and effective cable management system, the HyPort R80 is capable of creating a reliable and streamlined ICU environment to ensure patient safety. Recovery The lighting system of the HyPort R80 aims to create a comfortable, near-natural light ICU environment to enhance patient recovery. 1234 1 Circadian Light Simulating 24-hour natural daylight change to reflect circadian rhythm. 2 Examination Light Up to 10,000 lux, 5-level adjustable illuminance meets various needs of head and abdominal examination. 3 Reading Light Effectively avoid invalid glare to meet the reading needs of rehabilitating patients. 4 Navigation Light Providing enough lighting with less glare for medical staff’s easy observation and intervention. Efficiency The HyPort R80 is a highly integrated bedside device management system that helps caregivers organize medical devices to meet various clinical needs. It makes efficient use of beside space with a series of easy-to-use designs, enabling a more efficient workflow for medical staff. Folding-shelf design Suitable for both portable ventilators and integrated ventilators. p46-s3-2-web Bag-valve-mask management Making sure bag valve mask is easy to access and ready for emergency situations anytime when needed. p46-s3-3-web Partition management The pump separation layout allows medical staff to easily identify infusion pumps and feeding pumps. p46-s3-4-web Smooth movement The advanced braking technology ensures stability of the column when moving. NextPrevious Variety The HyPort R80 has been designed to meet the demands of different ICU layouts to create a safer, more efficient and comfortable ICU environment with patient-centric design.ICU double room solution A Product Specification Usage/Application Hospital Brand Mindray Model Name/Number HyPort B80 Features 60 Degreepanel interface for easier plug-in of gas and electricity Color White Panel Interface 60 Degree Product Description Gas and electricity separated 60°panel interface for easier plug-in of gas and electricity Flexible movement of sliding and rotating of the distributions Additional accessories for better management of details Considerate lighting option Safer and more effective workflow Gas and electricity separated 60°panel for easier plug-in of gas and electricity Better management Customized drawer solutions Wire basket - dfferent size options available Cable management solutions

Send Message
product image
Critical Care

Product Description: Medica Corporation’s EasyLyte® analyzer is a completely automated, microprocessor-controlled electrolyte system that uses ISE (Ion Selective Electrode) technology to make electrolyte measurements. The EasyLyte measures combinations of Na+, K+, in whole blood, serum, plasma, or urine. EasyLyte incorporates state-of-the-art electronics and an innovative ergonomic design that differentiates it significantly from competitors. The analyzer also stores quality-control data that is easily accessible. Patient histories are immediately retrievable for evaluation. EasyLyte analyzers combine simple yes/no prompted operation, low maintenance, and high reliability into one economical design. Product Features: EasyLyte is Easy to Use, Easy to Operate, Easy to Maintain The entire menu is driven by 2 simple buttons Results are displayed on LCD screen as well as printouts EasyLyte does 2 point as well as 1 point calibration Facility to analyze different type of samples: whole blood, serum, plasma ,urine samples EasyLyte has capillary and syringe sampling facility EasyLyte has auto probe wiping facility Analysis of electrolytes is done using 100ul of blood and 400ul of diluted urine Rate of analysis 55 secs per sample Analyzer is capable of storing 128 patients data with trilevel QC results Analyzer has modular plug in reagent pack system EasyLyte has facility for auto calibrations with a programmed interval of 4 hrs and also calibration on demand Analyzer has facility to upgrade to a walk away Electrolyte station by use of Auto Sampler It has a built in thermal printer and a RS 232 port for interfacing Product Applications: Sodium - Na, Potassium - K CLIA Classification: Moderate Complexity Sample Type: Whole Blood, Serum, Plasma or Urine Sample Size: 100 µL Whole Blood, Serum, Plasma, 60 µL capillary or 400 µL diluted (1:10) Urine Method: Direct measurement by Ion Selective Electrode (ISE) Measurement Range: Blood Urine Na+: 20 – 200 mmol/L Na+: 25 – 1000 mmol/L K+: 0.2 – 40 mmol/L K+: 1.0 – 500 mmol/L Cl-: 25 – 200 mmol/L Cl-: 25 – 500 mmol/L Li+: 0.2 – 5.0 mmol/L Ca++: 0.1 – 6.0 mmol/L pH: 6.0 - 8.0 Units Display Resolution: Na+: 0.1 mmol/L K+: 0.01 mmol/L Cl- : 0.1 mmol/L Li+: 0.01 mmol/L Ca++: 0.01 mmol/L pH: 0.005 units Test Time: Na/K Na/K/Cl Na/K/Li Na/K/Cl/Ca Analysis time (blood) 55 sec 55 sec 55 sec 60 sec Urine mode Yes Yes Yes No Analysis time (urine) 90 sec 90 sec 90 sec N/A EasySampler Yes Yes Yes No Capillary Samples Yes Yes Yes No Data Storage: Patient Results: up to 128 samples QC Results: up to 20 each Normal, Low, and High Calibration: Automatic or On-Demand Output: 128 x 64 pixel graphic display 24 column thermal printer Serial port (RS-232), EasySampler port Ambient Conditions: 15–32oC (60–90oF), <85% humidity Power: 100-240 VAC 50/60 Hz, 0.8A Size & Weight: 9.5”W x 16.5”H x 8.0”D (24 cm W x 42 cm H x 20 cm D) 13 lbs. (5.8 kg) Reagents used with this 'EasyLyte' CLIA Classification: Moderate Complexity Sample Type: Whole Blood, Serum, Plasma or Urine Sample Size: 100 µL Whole Blood, Serum, Plasma, 60 µL capillary or 400 µL diluted (1:10) Urine Method: Direct measurement by Ion Selective Electrode (ISE) Measurement Range: Blood Urine Na+: 20 – 200 mmol/L Na+: 25 – 1000 mmol/L K+: 0.2 – 40 mmol/L K+: 1.0 – 500 mmol/L Cl-: 25 – 200 mmol/L Cl-: 25 – 500 mmol/L Li+: 0.2 – 5.0 mmol/L Ca++: 0.1 – 6.0 mmol/L pH: 6.0 - 8.0 Units Display Resolution: Na+: 0.1 mmol/L K+: 0.01 mmol/L Cl- : 0.1 mmol/L Li+: 0.01 mmol/L Ca++: 0.01 mmol/L pH: 0.005 units Test Time: Na/K Na/K/Cl Na/K/Li Na/K/Cl/Ca Analysis time (blood) 55 sec 55 sec 55 sec 60 sec Urine mode Yes Yes Yes No Analysis time (urine) 90 sec 90 sec 90 sec N/A EasySampler Yes Yes Yes No Capillary Samples Yes Yes Yes No Data Storage: Patient Results: up to 128 samples QC Results: up to 20 each Normal, Low, and High Calibration: Automatic or On-Demand Output: 128 x 64 pixel graphic display 24 column thermal printer Serial port (RS-232), EasySampler port Ambient Conditions: 15–32oC (60–90oF), <85% humidity Power: 100-240 VAC 50/60 Hz, 0.8A Size & Weight: 9.5”W x 16.5”H x 8.0”D (24 cm W x 42 cm H x 20 cm D) 13 lbs. (5.8 kg)

Send Message
product image
HEMOGLOBIN METER

Mispa HbX Portable Haemoglobin Analyzer Overview Mispa HbX , Smart Haemoglobin analyzer is a symbol of advanced point of care equipment with modern technology and convenience, designed to deliver high accuracy, quality results with least turnaround time and low maintenance. Best in Class Hemoglobin Meter Mispa HbX, the Smart Haemoglobin Analyzer, is the best example of an advanced point-of-care hemoglobin reader with modern technology. It is easy to use and designed to deliver accurate, high-quality results with the shortest turnaround time and minimal maintenance. This digital Hb meter is one of the best hemoglobin meters available. Working of A Hemoglobin Meter or a hemoglobin reader A hemoglobin meter or a hemoglobin reader measures the amounts of hemoglobin and hematocrit in whole blood. Hemoglobin tests are typically performed to determine the RBC count, the severity of anemia, hematocrit, and other haematological factors. It is widely utilized during blood donations and key decisions such as blood transfusions. HbX works with Spectrophotometry Scattered compensation Technology for accurate and quick results Results will be retrieved with in less than 3 seconds after sample reading starts Sample Required: 7ul Capillary or Venous blood Three Step procedure makes HbX more convenient to use CV value will be less than 1.5 % 6 Hours Battery Backup makes it a hand equipment 2000 Data storage capacity Micro Fluidic cuvettes with 2 year Shelf life

Send Message
product image
immunoassayReagents

CRP (C-reactive protein) Rapid Quantitative Test The Finecare™ CRP Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA System for quantitative determination of C-reactive protein (CRP) in human whole blood,serum or plasma. The test is used as an aid to predict future cardiovascular diseases (CVD) as well as to see infection and inflammation. STORAGE AND STABILITY 1. Store the detector buffer at 4~30°C. The buffer is stable up to 24 months. 2. Store Finecare™ CRP Rapid Quantitative Test Cartridge at 4~30°C, shelf life is up to 24 months. 3. Test Cartridge should be used within 1 hour after opening the pack.

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ Cys C Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA System for quantitative determination of Cys C in human whole blood, serum or plasma. This test is used as an aid to predict the risk of developing chronic kidney disease. STORAGE AND STABILITY 1. Store the test kit at 4℃~30℃ up to the expiration date printed on package. 2. If removed from refrigerator, allow the test kit for 30 minutes to return to room temperature before testing. 3. Do not remove the Test Cartridge from the pouch until use. The Test Cartridge should be used within 1 hour once opened.

Send Message
product image
immunoassayReagents

#Immunoassay #Reagents #Biotechnology #LifeScience #Biochemistry #Research #LabLife #Science #AssayDevelopment #Antibodies #Proteins #DiagnosticTesting #ClinicalChemistry #Laboratory #MedicalResearch #Healthcare #ELISA #Fluorescence #Chemiluminescence #Immunology #MolecularBiology #CellBiology #AnalyticalChemistry #Microbiology #BiomedicalScience #Diagnostics #Innovation #Technology #PrecisionMedicine #Biopharmaceuticals #BiomedicalResearch #Bioreagents #Pathology #Immunodiagnosis #Antigen #AntibodyDetection #ResearchAndDevelopment #ClinicalTrials #HealthTech #Biomarkers #MedicalDevices #PrecisionHealth #BiomedicalEngineering #Therapeutics #Pharmaceuticals #DrugDiscovery #Genomics #Virology #Microarray #PCR #FlowCytometry #Biosensors #Nanotechnology #Immunochemistry #MedicalDevices #MedicalTechnology #HealthInnovation #BiotechStartup #HealthTechInnovation #MedicalInnovation #HealthScience #BiomedicalDevices #HealthcareTechnology #LabResearch #Bioassay #Bioinformatics #ClinicalLaboratory #AssayKit #PointOfCare #LaboratoryMedicine #DiagnosticKits #Chemistry #BiomedicalDiagnosis #BiochemicalAnalysis #Immunodiagnostics #InfectiousDiseases #BiomedicalTechnology #DiagnosticInstruments #HealthcareInnovation #MolecularDiagnostics #MedicalInstruments #InVitroDiagnostics #BiomedicalInnovation #ClinicalChemistry #BiomedicalTesting #BiomedicalDevices #HealthcareTechnology #DiagnosticSolutions #BiomedicalSolutions #LabEquipment #HealthcareDevices #BiomedicalDevices #DiagnosticDevices #MedicalDevices #BiomedicalTools #LabTools #ResearchTools #LabSupplies #LaboratoryEquipment #ResearchEquipment

Send Message
product image
immunoassayReagents

#Immunoassay #Reagents #Biotechnology #LifeScience #Biochemistry #Research #LabLife #Science #AssayDevelopment #Antibodies #Proteins #DiagnosticTesting #ClinicalChemistry #Laboratory #MedicalResearch #Healthcare #ELISA #Fluorescence #Chemiluminescence #Immunology #MolecularBiology #CellBiology #AnalyticalChemistry #Microbiology #BiomedicalScience #Diagnostics #Innovation #Technology #PrecisionMedicine #Biopharmaceuticals #BiomedicalResearch #Bioreagents #Pathology #Immunodiagnosis #Antigen #AntibodyDetection #ResearchAndDevelopment #ClinicalTrials #HealthTech #Biomarkers #MedicalDevices #PrecisionHealth #BiomedicalEngineering #Therapeutics #Pharmaceuticals #DrugDiscovery #Genomics #Virology #Microarray #PCR #FlowCytometry #Biosensors #Nanotechnology #Immunochemistry #MedicalDevices #MedicalTechnology #HealthInnovation #BiotechStartup #HealthTechInnovation #MedicalInnovation #HealthScience #BiomedicalDevices #HealthcareTechnology #LabResearch #Bioassay #Bioinformatics #ClinicalLaboratory #AssayKit #PointOfCare #LaboratoryMedicine #DiagnosticKits #Chemistry #BiomedicalDiagnosis #BiochemicalAnalysis #Immunodiagnostics #InfectiousDiseases #BiomedicalTechnology #DiagnosticInstruments #HealthcareInnovation #MolecularDiagnostics #MedicalInstruments #InVitroDiagnostics #BiomedicalInnovation #ClinicalChemistry #BiomedicalTesting #BiomedicalDevices #HealthcareTechnology #DiagnosticSolutions #BiomedicalSolutions #LabEquipment #HealthcareDevices #BiomedicalDevices #DiagnosticDevices #MedicalDevices #BiomedicalTools #LabTools #ResearchTools #LabSupplies #LaboratoryEquipment #ResearchEquipment

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ BNP Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA System for quantitative determination of Brain Natriuretic Peptides (BNP) in human whole blood or plasma. This test is used as an aid to predict the risk of heart failure. STORAGE AND STABILITY 1. Store the test kit at 4 ℃~30℃ up to the expiration date printed on package. 2. If removed from refrigerator, allow the test kit for 30 minutes to return to room temperature before testing. 3. Do not remove the Test Cartridge from the pouch until use. The Test Cartridge should be used within 1 hour once opened.

Send Message

Still searching for
dic?