Jaipur
+918529833535

'diameter'

Items tagged with 'diameter'

product image
Clinical Chemistry

With cutting-edge LED technology, the HyLED 7 Series offers excellent luminous efficiency, heat-free light source, and incredible long service life, giving you total support in OR. Usage/Application Operation Theater Positioning Ceiling Mounted Model Name/Number HyLED 7 Series Brand Mindray Light Source Type LED Central illuminance at 1m distance 160,000 lux Light field diameter(at 1m distance) 180~300 mm Depth of illumination(L1+L2) 1,200 mm Correlated color temperature 4,350 K Color rendering index(Ra) 96 Color rendering index(R9) 97 Shadow dilution with tube 100% Shadow dilution with one mask 75% Shadow dilution with tube and one mask 70% Shadow dilution with two masks 55% Shadow dilution with tube and two masks 50% Ambient illumination 8,000 lux Bulb power consumption 85 W Power supply 100~240 VAC, 50/60 Hz Number of LED bulbs 32 Light head dimension 600 mm Integrated Camera Optional Carrier-arm Camera Optional HyLED 7 Series Contact Us With cutting-edge LED technology, the HyLED 7 Series offers excellent luminous efficiency, heat-free light source, and incredible long service life, giving you total support in OR. Efficient & Economic • Incredible long service time up to 60,000 hours • Central Illumination: 160,000 lux/130,000 lux • Adjustable light field diameter • Max. depth of Illumination : 1,200 mm • Low power consumption Original & Unique • Perfectly integrated into laminar flow (Certified per DIN-1946 Part 4) • Touch screen panel for easier control • 330° rotatable integrated HD/FHD camera • Ultra-thin design & excellent maneuverability • Ergonomic and compact design less than 12kg Ergonomic and Compact Design • The ultra-thin concentrically circular design for better hygiene. • DIN-1946 Part 4 certificated. (12-2008) Flexible Design • Combined with an Ondal spring arm maximizes mobility and ensures stability. • Ultra-thin light head with only less than 12 Kg. • Smooth, metal back cover of the light head. High Performance • With a minimum lifetime of 60,000 hours, each latest generation LED illuminates far longer than traditional light sources. • Easier and less costly maintenance: each LED bulb with individual circuit can be replaced respectively, which will minimize the maintenance cost. Easy and Intuitive Control • Traditional control panel • Touch screen panel(optional) Shadow-free The HyLED 7 Series surgical light inherits the advanced technology from the HyLED 9 series and shows excellent shadow management function. The professional shadow dilution experiment simulated extreme situations by using tubes and masks proved that Mindray HyLED 7 Series surgical light has sufficient illumination even in extreme situations. Camera System for Communication The camera system provides better communication and documenting solutions. The camera system integrated with the surgical lights also provides a platform for medical research purpose, teaching communication and video documenting. Digital video recorder Supporting external USB storage device Supporting HDMI/YPbPr/HD-SDI/DVI-D/VGA input signal Default with camera control function Supporting video recording from other medical devices source

Send Message
product image
Hematology

Based on Mindray’s continuous innovation in hematology field, BC-5130 is especially tailored to assist diagnostic labs who need full CBC + 5-part results, with relatively low daily sample volume, restricted lab space and tight budget. As the lightest and most compact 5-part hematology analyzer so far from Mindray, BC-5130 is a highly user-friendly and innovative analyzer that offers cost efficient CBC and 5-part white cell differential results. It is targeted to fulfill and exceed the demands of our global customers by providing more accurate, more efficient and more innovative solutions for labs. Improved DC impedance technology is used to count and size the RBC and PLT. The smaller counting aperture (50 μm in diameter) provides better performance on samples with low PLT. Efficient Only three routine reagents are required. These have 2 years shelf life and also less consumed by BC-5130. Original QC and calibrator are also provided to ensure the hematology analyzer’s traceability and testing quality. WBC 5-Part differentiation,25 reportable parameters & 23 research parameters,3 histograms Whole blood Mode, Capillary whole blood mode & Prediluted Mode Tri-angle Laser Scatter + Chemical dye + Flow cytometry technology Dedicated optical counting channel for Basophil measurement 10.4 inch large TFT touch screen with user-friendly software Large storage capacity: Up to 1,50,000 samples Throughput:60 samples/Hour Compact Two kinds of lyse reagents are located inside of BC-5130, which helps the small labs to save space. BC-5130, the 5-part hematology analyzer offers a great solution for clinical labs, especially for those who have limited space. Its compact foot-print is a result of innovative technology improvements, including miniaturized semi-conductor laser source, highly integrated electronic boards and optimized liquid handling system. BC-5130 inherits it’s convenient and proven powerful software design from BC-6800 and BC-3600 platforms, the friendly interface is ideal for small sized labs. Running capillary blood through the sample probe directly is more convenient for the users in children’s hospitals, etc. For Prediluted mode, BC-5130 has higher dilution ratio than other 5-part hematology There’s NLR parameter in each CBC+DIFF result. Neutrophil-to-lymphocyte ratio (NLR) is calculated by dividing neutrophil count by lymphocyte count, usually from peripheral blood sample. In laboratory medicine, NLR is used as a marker of subclinical inflammation. According to clinical studies, NLR can be used as a prognostic factor of severe illness in COVID-19 patients. BC-5130 supports bi-directional LIS with test results and patient information. HL7 protocol is supported as well. Technology Compared with traditional helium neon laser or argon laser, semi -conductor laser has smaller size, lower cost and longer life cycle.

Send Message
product image
BP Apparatus

Relying on our expertise and know-how in this field, we are well-known as one of the prestigious organization in providing a wide range of Illuminated Magnifier. This product is primarily used in various industrial sectors. Illuminated Magnifier is precisely developed at well-developed unit using the best quality components and pioneering technology under the supervision of professionals. Superior Quality and flawless finishing have made it possible to gain a competitive edge in the market. We deliver our products using customized packaging and in a committed time frame. Features: High performance Low maintenance Quality tested Product Details: Magnification Power 4x Illumination Yes Brand Swastik Working Distance (mm) 250 mm Diameter 130 Lamp Power 22 W Type Illuminated Magnifier

Send Message
product image
Urinalysis Analyzer

High Performance "Full Automated System" Color Touch Panel for good usability 7 inch WVGA color touchscreen with high operability displays measurement results, instrument conditions and operating instructions. "Sample delivery system" enables micro volume samples to be measured As the sample is drawn through the nozzle and delivered correctly and quantitatively to each pad of the strip, the micro volume samples (minimum 1mL) can be measured easily. No cross contaminations are found on the reagent portions despite high sample volume. Sample Urine Test items Glu, Pro, Bil, Uro, Ket, pH, Nit, Bld, Leu, S.G., Alb, Cre(Alb/Cre ratio, Pro/Cre ratio can be calculated), turbidity and color tone Wavelength 5 LED wavelengths (430, 500, 565, 635, 760nm) Measurement principle Test strip :Dual-wavelength reflectance method (One-wavelength for Bld) Specific gravity :Reflection refractometryColor hue :Light-transmission measurementTurbidity :Light-scattering measurement method Test strip AUTION Sticks (10EA & 10PA) , Uriflet S 11UA Reaction time Approximately 60 seconds Throughput 225 samples per hour Strip storage Maximum 400 strips (200 strips x 2 feeder boxes) Required sample volume Normal, STAT measurement: Minimum 2 mL Small volume measurement: Minimum 1 mL Sample consumption Normal, STAT measurement: Maximum 0.90 mL Small volume measurement: Maximum 0.45 mL Sample container Sample tubes (length: 95 - 110 mm, diameter: ø14.0 - 15.8 mm) Maximum sample load 100 samples (Circulation) Data memory Normal, STAT, small volume measurement: 2500 tests Control measurement: 200 tests Check measurement: 50 tests Trouble list: 100 tests Display Large color liquid crystal display (800 × 480 dots) Built-in printer 58-mm width printer paper (24 digits) External output 1 port (Replaceable with the optional Ethernet terminal) Communication method RS-232C compliant (Switchable between one-way and two-way) Measurement environment Temperature: 10 - 30°C; Humidity: 30 - 60% RH (No condensation) Power requirements 100 - 240 V AC (Maximum power line fluctuation of ±10%), 50/60 Hz Power consumption 150VA (Maximum) Dimensions 530 (W) × 530 (D) × 550 (H) mm (including the sampler) Weight Main body: Approximately 36 kg Sampler: Approximately 4 kg

Send Message
product image
Laboratory Testing Analyzer

For smaller Laboratories Smaller, but with full functionality Compact size Full functions and performance in a compact size. *Size comparison with HA-8180V Accuracy HPLC technology provides accurate results-inluding detailed chromatogram. it will be shown in both IFCC and NGSP units. Cap-piercing method ADAMS Lite uses a cap-piercing method which enables the placement of capped blood samples. This not only reduces the workload but also helps protect lab technicians from infection. Easy-to-maintain No special tools are required for daily maintenance. Exchanged parts are hand-tightened, minimizing the workload of users. Specifications Measurement objects Whole blood or hemolysis sample Measured items Fast Mode: HbA1c (Stable HbA1c, S-A1c) and HbF Variant Mode: HbA1c (Stable HbA1c, S-A1c) and HbF (HbS and HbC separation and HbE and HbD detection can be performed). Measurement principle Reversed-phase cation exchange chromatography Measurement wavelength 420 nm/500 nm (Dual-wavelength colorimetry) Resolution 0.1% Ratio, 1 mmol/mol Measurement range HbA1c: 3 - 20%, 9 - 195 mmol/mol HbF: 0 - 100% Processing speed Variant mode: 160 seconds/test Fast mode: 100 seconds/test Sample consumption Whole blood sample: Approximately 4µL Anemia sample: Approximately 8 µL Hemolysis sample: Approximately 350 µL Sample container Sample tube: (12.3 or 15 mm in outer diameter) × (75 to 100 mm in height) Sample cup: 500 µL Sample supply Piercing sampling Compatible rack type ARKRAY racks (for 5 samples) Operating environment Temperature: 10 - 30°C; Humidity: 20 - 80% RH (No condensation) Display 20 digits × 2 lines LCD Printer For use with 58-mm width thermal printer paper Number of measurement samples Maximum 10 samples Power requirements AC 100 - 240 V±10%, 50/60 Hz Dimensions 330 (W) × 515 (D) × 485 (H) mm (Not including protrusions, eluent packs and hemolysis washing solution bottle)

Send Message
product image
Laboratory Testing Analyzer

The ADAMS A1c, HA-8180T is a fully automated Glycohemoglobin analyzer based on HPLC (High Performance Liquid Chromatography) and is highly effective for ß-thalassemia testing. Measurement speed: 3.5 minutes/test Measurement Item as below HbA2 HbF HbA1c (Stable HbA1c, S-A1c), HbS, HbC, HbE and HbD can be detected. Column design with no more pre-filter change. Color LCD with reagent level, graphs on screen. Samples Whole blood or hemolysis sample Measurement items HbA1c(Stable HbA1c, S-A1c), HbA2 and HbF (HbS, HbC, HbE and HbD can be detected.) Reagents *1 ELUENT 80A, ELUENT 80B, ELUENT 80CT and HEMOLYSIS WASHING SOLUTION 80H Column *2 COLUMN UNIT 80T Measurement principle Reversed-phase cation exchange chromatography Detection method Dual-wavelength colorimetry (wavelengths measured: 420nm/500nm) Resolution 0.1% Ratio, 1 mmol/mol Measurement range *3 HbA1c : 3-20%, 9-195 mmol/mol HbA2 : 2-10% HbF : 0-100% Guaranteed measurement range *4 HbA1c : 4.2-12.9%, 22-117 mmol/mol HbA2 : 2.4-6.3% HbF : 0.1-14.3% Processing speed 210 seconds per sample Sample consumption Approx.14μL(whole blood) Sample container Blood collection tube (12.3 to 15mm diameter) × ( 75 to 100mm length) Sample cup(500μL) Sampling method Cap-Piercing Rack type ARKRAY racks Number of measurement samples One-way transportation (factory set) : Maximum 50 samples Loop transportation : Maximum 100 samples Column temperature Approx. 39℃ Display Color graphic LCD with backlight Memory capacity 500 test results ( including calibration results ) Built-in Printer Termal printer, 58mm thermal paper External output Serial 1 port (Can be optionally used as an Ethernet port.) Measurement conditions Temperature : 15-30℃ Humidity : 20-80% relative humidity (non-condensing ) Required sample volume Blood collection tube : Minimum 10mm away from the bottom Sample cup : 400μL or more Warm-up time Maximum 30 min. Dimensions 530(W)×530(D)×530(H)mm (Not including the hemolysis washing solution bottle) Weight Analyzer: Approx. 39kg, Sampler: Approx. 4kg Power supply AC100V-240V ±10% 50/60Hz Power consumption Max. 300 VA *1, *2 Reagents and column are sold separately from HA-8180T analyzer. *3 Error-free measurement ranges. *4 Guaranteed ranges for obtaining results equivalent to those from HA-8160 TP mode measurement. ※Design and specications may be changed without prior notice

Send Message
product image
Laboratory Testing Analyzer

The ADAMS A1c, HA-8180 is a fully automated Glycohemoglobin (HbA1c) analyzer based on HPLC (High Performance Liquid Chromatography). HbA1c is a good parameter for long-term blood glucose monitoring in patients suffering from diabetes mellitus. Measurement Speed: 48 sec/test for Fast Mode and 90 sec/test for Variant mode. Measurement items are as follows. HA-8180V, Fast Mode HbA1c (Stable HbA1c, S-A1c) and HbF HA-8180V, Variant Mode  HbA1c (Stable HbA1c, S-A1c) and HbF HbS and HbC separation and HbE and HbD detection can be performed. ・Column design with no more pre-filter change ・Economical - improved aluminium reagents for more efficient reagent supply ・Color LCD with reagent level, graphs on screen Specifications Configuration Main body, sampler (with sample tube spinning unit) and accessories Measurement objects Whole blood or hemolysis sample Column COLUMN UNIT 80 Reagents ELUENT 80A, ELUENT 80B, ELUENT 80CV and HEMOLYSIS WASHING SOLUTION 80H Measurement items Fast Mode HbA1c (Stable HbA1c, S-A1c) and HbF Variant Mode HbA1c (Stable HbA1c, S-A1c) and HbF (HbS and HbC separation and HbE and HbD detection can be performed) Measurement ranges *1 HbA1C: 3 - 20%, 9 - 195 mmol/mol HbF: 0 - 100% Guaranteed measurement ranges *2 HbA1C: 4 - 16%, 20 - 151 mmol/mol HbF: 0.3 - 5% Measurement principle Reversed-phase cation exchange chromatography Measurement wavelength 420 nm / 500 nm (Dual-wavelength colorimetry) Sample supply Sampler Resolution 0.1 % Ratio, 1 mmol / mol Processing speed Variant mode : 90 seconds / test Fast mode : 48 seconds / test Sample consumption Approximately 14 μL (Whole blood) Required sample volume Sample tube : Minimum 10 mm away from the bottom Sample cup : 400 μL or more Sample container Sample tube : (12.3/15 mm diameter) × (75 to 100 mm length) Sample cup: 500 μL Compatible rack type ARKRAY racks Number of measurement samples One-way transportation (factory-set) : Maximum 50 samples Loop transportation : Maximum 100 samples Column temperature Approximately 40°C Warm-up time Maximum 30 minutes Display Large color LCD with backlight Printer For use with 58-mm width thermal printer paper Memory capacity 900 measurement results (including calibration results) External output Serial 1 port (Can be optionally used as an Ethernet port.) Communication system RS-232C compliant (Switchable between one-way and two-way communications.) Transmission speed RS-232C : Selectable from 300, 600, 1200, 2400, 4800, 9600 and 19200 bps Ethernet: 10BASE-T Dimensions 530 (W) × 530 (D) × 530 (H) mm (Not including the hemolysis washing solution bottle) Weight Main body: Approximately 39 kg, Sampler: Approximately 4 kg Power requirements 100 - 240 V AC ± 10 %, 50 / 60 Hz Power input Maximum 300 VA *1 Error-free measurement ranges *2 Guaranteed ranges for obtaining results equivalent to those from HA-8160 VP mode measurement

Send Message

Still searching for
diameter?