Jaipur
+918529833535

'day management'

Items tagged with 'day management'

product image
Rapid Test

Intended Use Dengue Day 1 Test is a rapid solid phase immuno-chromatographic test for the qualitative detection of Dengue NS1 Antigen and differential detection of IgM and IgG antibodies to Dengue virus in Human serum/plasma. This test is for in vitro diagnostic use only and is intended as an aid in the earlier diagnosis of Dengue infection & presumptive diagnosis between primary and secondary Dengue infection. Salient Features First line testing kit for detecting dengue infection from day 1 using NS1 Antigen & differential detection of IgM & IgG Antibodies. Diagnosis of both Primary & Secondary Infection. Detection of all the 4 Dengue serotypes (DEN-1, DEN-2, DEN-3 and DEN-4). Highly Sensitive & Highly Specific Long shelf life: 30 months at 2-30°C. Convenient pack sizes: 10 Tests, 30 Tests & 50 Tests.

Send Message
product image
Clinical Chemistry

With the built-in oxygen concentration monitoring system and effective cable management system, the HyPort R80 is capable of creating a reliable and streamlined ICU environment to ensure patient safety. Recovery The lighting system of the HyPort R80 aims to create a comfortable, near-natural light ICU environment to enhance patient recovery. 1234 1 Circadian Light Simulating 24-hour natural daylight change to reflect circadian rhythm. 2 Examination Light Up to 10,000 lux, 5-level adjustable illuminance meets various needs of head and abdominal examination. 3 Reading Light Effectively avoid invalid glare to meet the reading needs of rehabilitating patients. 4 Navigation Light Providing enough lighting with less glare for medical staff’s easy observation and intervention. Efficiency The HyPort R80 is a highly integrated bedside device management system that helps caregivers organize medical devices to meet various clinical needs. It makes efficient use of beside space with a series of easy-to-use designs, enabling a more efficient workflow for medical staff. Folding-shelf design Suitable for both portable ventilators and integrated ventilators. p46-s3-2-web Bag-valve-mask management Making sure bag valve mask is easy to access and ready for emergency situations anytime when needed. p46-s3-3-web Partition management The pump separation layout allows medical staff to easily identify infusion pumps and feeding pumps. p46-s3-4-web Smooth movement The advanced braking technology ensures stability of the column when moving. NextPrevious Variety The HyPort R80 has been designed to meet the demands of different ICU layouts to create a safer, more efficient and comfortable ICU environment with patient-centric design.ICU double room solution A Product Specification Usage/Application Hospital Brand Mindray Model Name/Number HyPort B80 Features 60 Degreepanel interface for easier plug-in of gas and electricity Color White Panel Interface 60 Degree Product Description Gas and electricity separated 60°panel interface for easier plug-in of gas and electricity Flexible movement of sliding and rotating of the distributions Additional accessories for better management of details Considerate lighting option Safer and more effective workflow Gas and electricity separated 60°panel for easier plug-in of gas and electricity Better management Customized drawer solutions Wire basket - dfferent size options available Cable management solutions

Send Message
product image
Medical Equipment

Mindray believes the best way to predict the future is to create it. The revolutionary BeneVision N22/N19 is designed to optimize user experience by satisfying all your clinical demands. With visionary-stimulating design, benchmarking ease of use, confidence-maximizing innovations and workflow-transforming interoperability, BeneVision N22/N19 is creating tomorrow’s monitoring perspective today. The design excellence of BeneVision N22/N19 has great originality to lead your perspective. A seamless outlook optimizes your monitoring experience with super large touchscreen, cool rotatable landscape & portrait layout, ultra slim main unit as well as plug-n-play modules. An ingenious user interface including multi-window flat menus, infographic alarm indications and online user guide offers extremely intuitive patient data and ultimate ease-of-use, while auto screen brightness always keeps patient in mind. Benefitting from cutting-edge clinical measurements, such as rSO2, ICG, PiCCO, AG, RM, BIS, NMT, and state-of-art clinical decision support tools, such as HemoSightTM, ST GraphicTM, DSA, BeneVision N22/N19 enhances your clinical confidence to the max and helps you make easier and faster clinical decisions. The connectivity capabilities of BeneVision N22/N19 fit seamlessly into your clinical workflow for paperless future. Revolutionary iView clinical informatics workstation brings all intelligence (PACS, LIS, EMR, etc) on screen at point of care for one-stop diagnosis. Industry-leading BeneLink integrates all bedside devices to the monitor realtimely and facilitates centralized data management.

Send Message
product image
Glucometer

Accu-Chek® Instant Blood glucose monitor Your effortless choice Item Description Wishing there was an easy way to monitor your blood glucose levels? With the new Accu-Chek Instant meter, it's as easy and fast as checking your phone messages. There is no setup required – just insert a test strip, apply a small blood sample and read your blood glucose result on the large display. Additional specifications Model: Accu‑Chek Instant wireless blood glucose meter​ Meter storage conditions: Temperature: -25 – 70° C Memory capacity: The meter automatically stores at least 720 blood glucose results in memory, but only the last blood glucose result and your 7, 30, and 90 day averages can be viewed on the meter. To view stored blood glucose results, transfer them to a compatible software application. The meter automatically stores at least 30 control results in memory, but only the current control result can be viewed on the meter. To view stored control results, transfer them to a compatible software application. Sample claims: Capillary: Yes Venous: Yes Arterial: Yes Neonate: Yes Non-fingerstick sample Claim: Palm, forearm, upper arm Measuring principle: FAD glucose dehydrogenase (GDH) Measuring time: 4 Sec Measuring conditions: 4 °C to 45 °C (39 °F to 113 °F) Hematocrit range: 10 to 65 % Humidity range: 10 to 90 % Altitude independence: 0 to 3,094 m (10,150 ft) Automatic off: 90 seconds after performing a test, 15 seconds after test strip is removed, or 5 seconds from the last test result screen. Weight: Approx. 40 g (with batteries) Construction: Hand-held Protection class: III Meter type: The Accu-Chek Instant meter is suitable for continuous operation. Interfaces: Connectivity using BLE wireless Technology to mySugr App; USB interface with USB cable to transfer data to the Accu‑Chek Connect Online system. Benefits and Features Effortless Bluetooth synchronization with mySugr diabetes management app The intuitive target range indicator gives you visual reassurance. It can be individualized to suit your personal therapy goals Only what you need: Your test result and your averages (7/30/90 days) are visible on the meter Sleek, modern design with large, easy-to-read BG numbers and a bright, backlit display No set up required – just insert a strip, apply a small blood sample, and read your blood glucose result on the large display Easy-edge test strip: Apply a small drop of blood anywhere along the wide, yellow edge Proven accuracy guaranteed by the makers of the Accu-Chek brand, fulfilling the requirements of the ISO 15197:2013, EN ISO 15197:2015 All data can be uploaded to the mySugr by using Bluetooth Low Energy wireless technology and to Accu-Chek Connect Online portal by using USB Test strips come in a 10, 25, 50 vial so you can choose whatever fits your budget or therapy Enjoy virtually pain-free testing with the Accu-Chek Softclix lancing device

Send Message
product image
Glucometer

Accu-Chek Instant S blood glucose meter Item Description Get instant clarity of your blood glucose level with Accu-Chek Instant S meter, it's as easy and fast as checking your phone messages. There is no setup required – just insert a test strip, apply a small blood sample and read your blood glucose result on the large display. Benefits and Features The Intuitive target range indicator gives you visual reassurance. It can be individualized to suit your personal therapy goals* Only what you need - Your test result and your averages (7/30/90 days) are visible on the meter No set up required – Just insert a strip, apply a small blood sample, and read your blood glucose result on the large display Easy-edge test strip - Apply a small drop of blood anywhere along the wide, yellow edge Proven accuracy guaranteed by the makers of the Accu-Chek brand, fulfilling the requirements of the ISO 15197:2013^ Test strips come in a 10, 25, 50 vial, so you can choose whatever fits your budget or therapy All data can be uploaded to the Accu-Chek Connect Online portal (USB) Enjoy virtually pain-free testing with the Accu-Chek Softclix lancing device Additional specifications Meter storage conditions: Temperature: -25° C to +70° C (39° F to 113° F) Memory capacity: The meter automatically stores at least 720 blood glucose results in memory, but only the last blood glucose result and your 7, 30, and 90 day averages can be viewed on the meter. To view stored blood glucose results, transfer them to Accu-Chek Connect Online diabetes management . Automatic off: 90 seconds after performing a test, 15 seconds after test strip is removed, or 5 seconds from the last test result screen. Weight: Approx. 40 g (with batteries) Construction: Hand-held Meter type: The Accu-Chek Instant S meter is suitable for continuous operation. Interfaces: USB: micro-B connector Serial number: Unique serial number etched into meter back Sample claims: Capillary: Yes Venous: Yes Arterial: Yes Neonate: Yes Measuring principle: FAD glucose dehydrogenase (GDH) Hematocrit range: 10 to 65 % Humidity range: 10 to 90 % Altitude independence: 0 to 3,094 m (10,150 ft) Measuring time: Less than 4 seconds Measuring conditions: 4° C to 45° C(39° F to 113° F)

Send Message
product image
Glucometer

FREESTYLE LIBRE PRO Flash Glucose Monitoring System Product Description FreeStyle Libre Pro is clinician's glucose assessment tool that redefines easy. FreeStyle Libre Pro is for the use by Healthcare Professionals only. Easy for patients. Convenient and scalable for clinic. FreeStyle Libre Pro Sensor Small and discreet The FreeStyle Libre Pro sensor is applied on the back of the upper arm. The sensor is water resistant1. Very thin filament Filament is <0.4 mm thick and inserted 5 mm beneath the skin surface to measure glucose levels. Up to 14 days of data Automatically records glucose level every 15 minutes to provide more insightful patterns. Data is blinded from the patient No patient interaction with the sensor is required — designed to integrate with patients' daily lives. FreeStyle Libre Pro Reader The reader stays in the clinic No need to worry about patients losing or damaging components. One reader device starts multiple patients Multiple patients per reader minimizes waiting time and scheduling issues. Lower costs for the clinic The need for only one reader device can help lower your clinic expenses. FreeStyle Libre Pro is an innovative sensor-based ‘Flash Glucose Monitoring’ device that captures glucose readings every 15 minutes for up to 14 days, and gives complete glucose profile report in the form of 'Ambulatory Glucose Profile'. Daily Patterns with Ambulatory Glucose Profile AGP offers a standardized visualization of glucose data that is reliable, predictive, and actionable. The glucose data, generated by Flash Glucose Monitoring over several days or weeks, are collapsed into a single 24-hour period, creating a view of a modal day. This view reveals underlying patterns in glucose variability to a greater extent than using HbA1c by itself. AGP allows healthcare professionals to more effectively visualize and utilize glucose data in the clinical management of diabetes. AGP identifies areas of hyperglycemia, hypoglycemia and glucose variability. Daily Glucose Summary With ‘Daily Glucose Summary’ report, it is easier to know patient’s ‘Time in Target’ Product Specification Model Name/Number Freestyle Libre Pro Averages 14 Days Result Time 3 sec Display LCD Memory Capacity 500 test results Power Supply 1 battery (type CR2032) Sample Type Peripheral Capillary Whole Blood/Venous Whole Blood Weight 45g Including Battery Hematocrit Range 50% Minimum Order Quantity 5 Piece

Send Message
product image
Clinical Chemistry

Best Semi Automatic Biochemistry Analyzer AT Smart from Accurex. AT SMART is a Biochemistry/Clinical Analyzer with a user-friendly and the human interface is via touch screen. It measures the optical densities of samples & calculates the sample concentration which are used for biochemical investigation. This Biochemistry Machine operates from near UV to visible range. Semi Auto Analyzer AT SMART is CE certified and has undergone rigors testing before being delivered to customers. About •SMART MAINTENANCE •SMART LIS •SMART INVENTORY MANAGEMENT REDUCED ERRORS: IT allows for the accurate collection of data, automated workflows & minimized waste. SAVES TIME: Patient monitoring can be done in real-time, saves engineers visiting time. BETTER PATIENT EXPERIENCE: A connected laboratory system creates an environment that meets each patient’s needs. INSTRUMENT BREAKDOWN MANAGEMENT: Real-time data helps to monitor instrument performance. ONLINE REACTION CURVES: • Real time reaction curve with special • Flagging gives confidence in patient reports. INTELLECTUAL SOFTWARE: • User friendly Device. • 150 Direct access test keys gives freedom to select parameters easily. • Availability of different assay modes. DRY BATH INCUBATOR: • Dry bath incubator with 12 test tube positions • Mini size with 15 minutes start up time FEATURES: •Remote access & monitoring via Internet •150 test parameters •Built-in thermal printer to print results, enzymatic curves and standard calibration curves •Large graphic display with real time graph display for enzymatic reaction •Touch screen interface with dynamic test access key SPECIFICATIONS: Methodology- • Absorbance • Endpoint with standard, factor, sample blank & diffrential • Two-point (fixed time) and multi point kinetics • Multi standard calibration • Mono or bi-chromatic reading • Turbidimetry Optical System- • Principle: photometry • Range of measurement: 0.0-3.0A • Spectral range selection: Automatic via filter wheel • Filters: 340, 405, 505, 546, 578 and 630 nm plus two free position • Bandwidth:10nm (+/- 2nm) • Light source: Life Long Halogen lamp • Blanking: Automatic • Detector: Silicon Photodiode Photometer- • Peltier regulated 25ºC, 30ºC and 37ºC • Flow cell of 18 µ L • Continuous flow system with peristaltic pump • Programmable Sipping Volume Memory- • 150+ User Defined Test Programs • 1000 test results in instrument memory and unlimited test resultresult storage via cloud • Reagent Blank • 2 Level of QC Quality Control- • Levy-Jennings chart using westgard’s rules • 30 Normal and abnormal QC values for selected test User Interface- • Graphic LCD back Lit 240×64 pixels • Touch Screen input • Data port and cloud connectivity • Type : Graphic thermal printer Power & Dimensions- • Voltage : 220 V • Frequency : 50 Hz • Maximum power : < 150 VA • Maximum relative humidity : 75% • Compact form factor • Weight: < 6kgs Safety Information Precautions • Instrument should be operated only by authorised or trained personnel • For any reasons, unauthorised personnel should not be engaged for servicing or removing the cabinet • Power source should be regulated either by voltage stabilizer or regulated power back up (UPS). If inverter is been used, please ensure there exists a voltage stabilizer • Reagents recommended by the company to be preferably used • Flow cell needs to be rinsed regularly with the company recommended flow cell cleaning solution • User is requested not to use any other pointing devices other than being supplied by company while operating touch screen • The operating environment should be clean and protected from direct sunlight • During the day at the end of the work, it should be ensured that flow cell is always filled with distilled water • During transport / longer duration of shut down, th Direction for Use Please ensure that the power source is properly grounded and voltage between Line and Ground is less than 2V AC – 5V AC. • Please ensure that the instrument is placed on a firm table, clean environment, and sufficient ventilation space. • Switch On the instrument. • Instrument will run its own internal diagnostic routines, to ensure proper working of critical functions. • Allow the instrument to stabilize for 10 minutes. • During the stabilization time, please wash the flow cell with cleaning solution and distilled water for at least two times. • During shut down, ensure that the flow cell is cleaned with flow cell cleaning solution and rinsed thoroughly using distilled water. • For overnight shutdown, please ensure flow cell is filled with distilled water. • Cover the instrument with the given dust cover Other Info GENERAL INFORMATION While installing and setting up the instrument, few safety warnings and general precautions described in the further sections must be observed. A. Power Supply : • Power source should be grounded and have either servo stabilizer or regulated power back up • Power cord should be CE , CSA and UL marked • Voltage : 115 – 230 Volts ± 10% 50 – 60 Hz • Grounding: Make sure that electrical power source is properly grounded.

Send Message
product image
Clinical Chemistry

Product Specification Model Name/Number HumaStar 200 Brand Human Automation Fully Automatic Display Digital Dimensions 69 x 76 x 52 cm (WxDxH) Frequency 50/60 Hz Voltage 220-240 or 110-120 Vac Temperature 16-30 Degree C Throughput Up to 200 t/h throughput Weight 51 kg Reaction volume 210-350 il Wash station 6 dispensing needles Water consumption < 2 l/h (8 ml/test) Languages English, French, Spanish Software (other languages can be added) Humidity < 80 % non-condensing Data External computer required (Pentium IV, 2 GHz Mode Open, random-access, STAT Product Description Product Detail : Unique Random-Access Analyzers for Small to Medium Size Laboratories Unique design Unique software architecture Unique features Analysis Endpoint (bichromatic), Differential endpoint (with sample blank), Fixed time, Kinetic (bichromatic) Multi-standard (up to 8), factor, linear, non linear (cubic-spline, poly-linear and logit-log four parameters) Samples Removable sample tray 60 positions: primary tubes 12–12.5x100 mm and 10 mm cups Optional: sample tray for 20 primary tubes 12–16x100 mm and 20 cups 3.5 ml Sample volume: 2–300 µl Internal barcode reader Automatic pre- and post-dilution Test profiles and replicates Reagents Removable reagent tray 30 reagent / diluent positions 50 and 20 ml bottles, adapter for tubes and cups Reagent volumes: 5–350 µl Refrigeration to ~9 Degree C below ambient (at bottom of bottle) Substrates, Enzymatic, Turbidimetric Reaction Reaction volume: 210–350 µl 80 reusable Bionex® cuvettes 6 mm optical path Heat transfer by air Pipetting Needle shock detector Capacitive liquid level detector Wash station 8-step cuvette wash station Systemic and special washing solution HumaStar 200: 6 dispensing needles Water consumption < 2 l/h (8 ml/test) Optical system 9 discrete wavelengths (340, 405, 505, 546, 578, 600, 650, 700 nm, one free position) Band pass: +/– 5 nm Photometric linearity: 0–2.5 Abs Stability: <1 % drift per day Management 20 GB HDD, 512 MB RAM, CD/R, USB) Windows 7® with .NET framework 4.0 English, French, Spanish OS recommended Core i3TM or dedicated graphic card recommended Minimum 900 dots resolution Designed for touch screen (1280x1024 pixel) LIS: Bi-directional, polling mode, ASTM, ethernet Printouts By patient, single test, complete sample, work sheet, method and QCs, calibration curves, kinetics, continuous printing

Send Message
product image
Rapid Test

Oscar Chikungunya test is an in vitro diagnostic rapid test based on the principle of immunochromatography on a membrane, for simultaneous and differential detection of Chikungunya specific antibody (IgM/IgG) in human serum/ plasma for diagnosis of Chikungunya infection. For professional use only. Pack Size: 10 Tests Several methods can be used for diagnosis of chikungunya virus infection. Serological tests, such as ELISAs may confirm the presence of IgM and IgG anti-chikungunya antibodies. The virus may also be directly detected in the blood during the first few days of infection by both serological and virological methods (particularly reverse transcriptase–polymerase chain reaction (RT–PCR)). There is no specific antiviral drug treatment for chikungunya. The clinical management targets primarily to relieving the symptoms, including the joint pain using anti-pyretics, optimal analgesics, drinking plenty of fluids and general rest. The joint pain is often very debilitating; it usually lasts for a few days, but may be prolonged for weeks, months or even years--the name “chikungunya” derives from a word in the Kimakonde language, meaning “to become contorted”, and describes the stooped appearance of sufferers with joint pain (arthralgia).

Send Message

Still searching for
day management?