Jaipur
+918529833535

'column temperature'

Items tagged with 'column temperature'

product image
Laboratory Testing Analyzer

The ADAMS A1c, HA-8180T is a fully automated Glycohemoglobin analyzer based on HPLC (High Performance Liquid Chromatography) and is highly effective for ß-thalassemia testing. Measurement speed: 3.5 minutes/test Measurement Item as below HbA2 HbF HbA1c (Stable HbA1c, S-A1c), HbS, HbC, HbE and HbD can be detected. Column design with no more pre-filter change. Color LCD with reagent level, graphs on screen. Samples Whole blood or hemolysis sample Measurement items HbA1c(Stable HbA1c, S-A1c), HbA2 and HbF (HbS, HbC, HbE and HbD can be detected.) Reagents *1 ELUENT 80A, ELUENT 80B, ELUENT 80CT and HEMOLYSIS WASHING SOLUTION 80H Column *2 COLUMN UNIT 80T Measurement principle Reversed-phase cation exchange chromatography Detection method Dual-wavelength colorimetry (wavelengths measured: 420nm/500nm) Resolution 0.1% Ratio, 1 mmol/mol Measurement range *3 HbA1c : 3-20%, 9-195 mmol/mol HbA2 : 2-10% HbF : 0-100% Guaranteed measurement range *4 HbA1c : 4.2-12.9%, 22-117 mmol/mol HbA2 : 2.4-6.3% HbF : 0.1-14.3% Processing speed 210 seconds per sample Sample consumption Approx.14μL(whole blood) Sample container Blood collection tube (12.3 to 15mm diameter) × ( 75 to 100mm length) Sample cup(500μL) Sampling method Cap-Piercing Rack type ARKRAY racks Number of measurement samples One-way transportation (factory set) : Maximum 50 samples Loop transportation : Maximum 100 samples Column temperature Approx. 39℃ Display Color graphic LCD with backlight Memory capacity 500 test results ( including calibration results ) Built-in Printer Termal printer, 58mm thermal paper External output Serial 1 port (Can be optionally used as an Ethernet port.) Measurement conditions Temperature : 15-30℃ Humidity : 20-80% relative humidity (non-condensing ) Required sample volume Blood collection tube : Minimum 10mm away from the bottom Sample cup : 400μL or more Warm-up time Maximum 30 min. Dimensions 530(W)×530(D)×530(H)mm (Not including the hemolysis washing solution bottle) Weight Analyzer: Approx. 39kg, Sampler: Approx. 4kg Power supply AC100V-240V ±10% 50/60Hz Power consumption Max. 300 VA *1, *2 Reagents and column are sold separately from HA-8180T analyzer. *3 Error-free measurement ranges. *4 Guaranteed ranges for obtaining results equivalent to those from HA-8160 TP mode measurement. ※Design and specications may be changed without prior notice

Send Message
product image
Laboratory Testing Analyzer

The ADAMS A1c, HA-8180 is a fully automated Glycohemoglobin (HbA1c) analyzer based on HPLC (High Performance Liquid Chromatography). HbA1c is a good parameter for long-term blood glucose monitoring in patients suffering from diabetes mellitus. Measurement Speed: 48 sec/test for Fast Mode and 90 sec/test for Variant mode. Measurement items are as follows. HA-8180V, Fast Mode HbA1c (Stable HbA1c, S-A1c) and HbF HA-8180V, Variant Mode  HbA1c (Stable HbA1c, S-A1c) and HbF HbS and HbC separation and HbE and HbD detection can be performed. ・Column design with no more pre-filter change ・Economical - improved aluminium reagents for more efficient reagent supply ・Color LCD with reagent level, graphs on screen Specifications Configuration Main body, sampler (with sample tube spinning unit) and accessories Measurement objects Whole blood or hemolysis sample Column COLUMN UNIT 80 Reagents ELUENT 80A, ELUENT 80B, ELUENT 80CV and HEMOLYSIS WASHING SOLUTION 80H Measurement items Fast Mode HbA1c (Stable HbA1c, S-A1c) and HbF Variant Mode HbA1c (Stable HbA1c, S-A1c) and HbF (HbS and HbC separation and HbE and HbD detection can be performed) Measurement ranges *1 HbA1C: 3 - 20%, 9 - 195 mmol/mol HbF: 0 - 100% Guaranteed measurement ranges *2 HbA1C: 4 - 16%, 20 - 151 mmol/mol HbF: 0.3 - 5% Measurement principle Reversed-phase cation exchange chromatography Measurement wavelength 420 nm / 500 nm (Dual-wavelength colorimetry) Sample supply Sampler Resolution 0.1 % Ratio, 1 mmol / mol Processing speed Variant mode : 90 seconds / test Fast mode : 48 seconds / test Sample consumption Approximately 14 μL (Whole blood) Required sample volume Sample tube : Minimum 10 mm away from the bottom Sample cup : 400 μL or more Sample container Sample tube : (12.3/15 mm diameter) × (75 to 100 mm length) Sample cup: 500 μL Compatible rack type ARKRAY racks Number of measurement samples One-way transportation (factory-set) : Maximum 50 samples Loop transportation : Maximum 100 samples Column temperature Approximately 40°C Warm-up time Maximum 30 minutes Display Large color LCD with backlight Printer For use with 58-mm width thermal printer paper Memory capacity 900 measurement results (including calibration results) External output Serial 1 port (Can be optionally used as an Ethernet port.) Communication system RS-232C compliant (Switchable between one-way and two-way communications.) Transmission speed RS-232C : Selectable from 300, 600, 1200, 2400, 4800, 9600 and 19200 bps Ethernet: 10BASE-T Dimensions 530 (W) × 530 (D) × 530 (H) mm (Not including the hemolysis washing solution bottle) Weight Main body: Approximately 39 kg, Sampler: Approximately 4 kg Power requirements 100 - 240 V AC ± 10 %, 50 / 60 Hz Power input Maximum 300 VA *1 Error-free measurement ranges *2 Guaranteed ranges for obtaining results equivalent to those from HA-8160 VP mode measurement

Send Message
product image
Immunology Analyzer

Product Description: The LisaScan EM Microplate Reader is an economical, compact and versatile 8 channel ELISA reader which can be adapted to various ELISA applications. It is India’s largest selling automated microplate ELISA reader Product Features: Wavelength Range: 400 to 750nm with a dynamic measurement range of 0.0 to 4.0 O.D 100 user-programmable test storage Inbuilt thermal printer for reports & graphs Auto self-check on start-up & external printer connectivity Compatible to various plate geometrics-96 well microplates ( Flat, U & V bottom) Wavelength selection: Monochromatic, bi-chromatic & multi-chromatic* Reading time 8 sec. for single wavelength using 8-channel optics User-friendly inbuilt operation software with 7000 sample test results storage User interface: High Resolution LCD display with 20 Keys Rugged waterproof & membrane panel Computer linked ELISA data management software - Eli-LIMS* CE marked Inbuilt shaking facility,Three Linear Speeds - Low, Medium and Fast Reports can be printed using internal thermal or external printer No need of manual calculations and documentation Documentation ease – Reports can even be stored using optional Eli-LIMS software Computer can be connected Extensive ELISA data management Product Applications: ELISA System type: Open System Plate types: 96 well plates Wells Type: U, V and Flat bottom wells Operating Modes: Absorbance Quantitative Qualitative Semi-Quantitative Kinetic Mode Measurement Modes: Continuous / Step Shaking Modes: Three Linear Speeds - Low, Medium and Fast. Time duration can be set Wavelength Selection: Monochromatic Bi-Chromatic Multi-Chromatic* (Maximum 4) Calculation Modes: Non-linear Standard Cut-off Index Formula Column Subtraction Linear Regression Point to Point Cubic Spline Linear – Log Blank Options: Blank, Control, Assay Validation equations Against Air, Well Plate, Column, Column-mean Row, Row mean Number of programmable standards / calibrators: Up to 10 standards /test Storage/ display/ printing of multi standard curves and cut-off equations for all parameters Test Programs: 100 totally “open” Test Programs Photometer: Measuring system: 8-Channel optical system Lamp Source: Tungsten Halogen with Lamp saver function Wavelength Range: 400 to 750 nm Standard Filters: 405 nm, 450 nm, 492 nm, 630 nm (Optional two filters 578 nm, 700 nm), 10 nm Band Pass Dynamic Range: 0.0 ~4.0 OD Photometric accuracy: < 1% at 2.5 OD at 450 nm Photometric resolution: 0.001 OD Linearity: <1% at 2.5 OD at 450 nm Measurement Time: SPEED : 8 Seconds single wavelength NORMAL : 17 Seconds single wavelength Display: High resolution Graphics LCD 320x240 pixels, LED Backlight, View area: 120x92 mm Keyboard: Rugged waterproof & membrane panel PC Communication: USB Based Protocol compatible with Eli-LIMS and TNW Built-in Thermal Printer: Built in High resolution, 384 dots per line, thermal Type with full graphics facility printer and option for connecting External Parallel Printer (or USB Printer using External Adaptor). Computer interfacing Software: Windows Based Software Eli-LIMS with data managemenOptional Windows Based Software with data management capabilities to store patient results, store/display calibration curve /QC curves. Reports on internal and external printers: Report generation for last 7000 Sample’s is viewed/printed/stored. Lab name in Print-out Lab name in Display Collated reports Print-out of Normal Range along with the result (on external printer only). Graphs can be printed on Thermal Printer Sorted by: Date I.D. Both by Date & I.D. Test Plate ID Online Help: At each step on-line help in each menu. Beeps and online instructions on erroneous entry. Special HELP key on keypad. Operating Temperature: 20˚ C to 40˚ C Storage Temperature: -10˚ C to 50˚ C Humidity: Max. 80% RH, non- condensing Power Supply: 16 V - 24.5 V DC using External Auto ranging SMPS adapter 115/230VAC ±10%, 50/60Hz., Max. 90 Watt. (CE & UL certified) Dimension: 502 mm X 369 mm X 216 mm Weight: 7 Kg

Send Message
product image
Biochemistry Analyzer

Overview A fully automated POC Auto Dry Biochemistry Analyzer called Mispa Chem Dx, With Just 3 to 4 drops (100ul) of whole blood to test up to 19 General and Special chemistry tests in less than 12 minutes. Mispa Chem Dx works on absorption spectroscopy where a change in absorbance is detected by an absorption spectrum and an algorithm is used to calculate the end concentration of the sample in the reagent dry disc. The reagent disc consists of lyophilized reagent beads, diluent, and calibration details in the QR code. The reagent disc contains an intelligent internal quality control system IQC which continuously monitors the disc function to ensure reaction stability and optimal disc performance, IQC is the engine that drives the Mispa Chem Dx accurately and precisely Low Sample Consumption Easy to Use Maintenance Free Accurate Result Disposable reagent disc Sample volume: 100µl Testing time: 12 minutes / sample Temperature: 37°C ± 0.3°C Resolution: 0.001Abs Absorbance: 0-3.0Abs Sample type: Heparinized whole blood, serum, plasma (heparin) QC&Calibration: IQC (Intelligent Quality Control/Calibration) Work condition: Temperature:10-30°C Humidity: 30%-70% Testing method: End point, kinetic, fixed time, turbidmetry etc Light source: 12V/20W, Halogen tungsten lamp with life span over 2500 hours Power supply: AC 100V-240V, 50-60Hz Display: Android 7.0 inch 800*480, multi-point capacitive touch screen Storage: 500,000 results Printer: Built-in thermal printer Interface: 4 USB ports, 1 LAN port Dimension: 315*375*475mm. 4.2kg(N.W.), 7kg(G.W.)

Send Message
product image
immunoassayReagents

Cortisol Rapid Quantitative Test The Finecare™ Cortisol Rapid Quantitative Test is a fluorescence immunoassay for quantitative determination of Cortisol in human serum, plasma or whole blood. The test is used as an aid to the screening of adrenal dysfunction and assessment of the treatment effect. STORAGE AND STABILITY 1. Store the test kit at 4~30℃ up to the expiration date printed on package. 2. If removed from refrigerator, allow the test kit for 30 minutes to return to room temperature before testing. 3. Do not remove the test cartridge from the pouch until use. The test cartridge should be used within 1 hour once opened.

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ S100β Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA Meters for quantitative determination of S100β in human serum, plasma or whole blood. The test is used as an aid to the assessment of the level of cerebral injury. STORAGE AND STABILITY 1. Store the test kit at 4 ~ 30 ℃ up to the expiration date printed on package. 2. If removed from refrigerator, allow the test kit for 30 minutes to return to room temperature before testing 3. Do not remove the Test Cartridge from the pouch until use. The Test Cartridge should be used within 1 hour once opened.

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ AFP Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA System for quantitative determination of Alpha-Fetoprotein in human whole blood, serum or plasma. The test is used as an aid for early auxiliary diagnosis and the evaluation of therapeutic efficiency for primary hepatic carcinoma. STORAGE AND STABILITY 1. Store the test kit at 4℃~30℃ up to the expiration date printed on package. 2. If removed from refrigerator, allow the test kit for 30 minutes to return to room temperature before testing. 3. Do not remove the Test Cartridge from the pouch until use. The Test Cartridge should be used within 1 hour once opened.

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ PSA Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA System for quantitative detemination of Prostate Specific Antigen (PSA) in human whole blood, serum or plasma. The test is used as an aid in diagnosis of prostatic cancer. STORAGE AND STABILITY 1. Store the test kit at 4~30℃ up to the expiration date 2. If removed from refrigerator, allow the test for 30 minutes to return to room temperature before testing. 3. Do not remove the device from the pouch until ready to use. The test cartridge should be used within 1 hour once opened.

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ FPSA Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA System for quantitative determination of Free Prostate Specific Antigen (FPSA) in human whole blood, serum or plasma. The test is used as an aid in diagnosis of prostatic cancer. STORAGE AND STABILITY 1. Store the test kit at 4℃~30℃ up to the expiration date printed on package. 2. If removed from refrigerator, allow the test kit for 30 minutes to return to room temperature before testing. 3. Do not remove the Test Cartridge from the pouch until use. The Test Cartridge should be used within 1 hour once opened.

Send Message

Still searching for
column temperature?