Jaipur
+918529833535

'calibration results'

Items tagged with 'calibration results'

product image
Biochemistry Analyzer

Overview A fully automated POC Auto Dry Biochemistry Analyzer called Mispa Chem Dx, With Just 3 to 4 drops (100ul) of whole blood to test up to 19 General and Special chemistry tests in less than 12 minutes. Mispa Chem Dx works on absorption spectroscopy where a change in absorbance is detected by an absorption spectrum and an algorithm is used to calculate the end concentration of the sample in the reagent dry disc. The reagent disc consists of lyophilized reagent beads, diluent, and calibration details in the QR code. The reagent disc contains an intelligent internal quality control system IQC which continuously monitors the disc function to ensure reaction stability and optimal disc performance, IQC is the engine that drives the Mispa Chem Dx accurately and precisely Low Sample Consumption Easy to Use Maintenance Free Accurate Result Disposable reagent disc Sample volume: 100µl Testing time: 12 minutes / sample Temperature: 37°C ± 0.3°C Resolution: 0.001Abs Absorbance: 0-3.0Abs Sample type: Heparinized whole blood, serum, plasma (heparin) QC&Calibration: IQC (Intelligent Quality Control/Calibration) Work condition: Temperature:10-30°C Humidity: 30%-70% Testing method: End point, kinetic, fixed time, turbidmetry etc Light source: 12V/20W, Halogen tungsten lamp with life span over 2500 hours Power supply: AC 100V-240V, 50-60Hz Display: Android 7.0 inch 800*480, multi-point capacitive touch screen Storage: 500,000 results Printer: Built-in thermal printer Interface: 4 USB ports, 1 LAN port Dimension: 315*375*475mm. 4.2kg(N.W.), 7kg(G.W.)

Send Message
product image
Clinical Chemistry

ADVIA Chemistry XPT System An advanced, automated clinical chemistry analyzer for high-volume laboratories The ADVIA® Chemistry XPT System provides timely, reliable results with continuous operation to meet the chemistry workloads of the most demanding laboratories. Delivers high throughput of up to 2400 tests per hour. Manages comprehensive testing with a menu of more than 115 assays. Improves workflow using automation and system technologies such as micro-volume and aliquot retention. Features & Benefits The ADVIA Chemistry XPT System*** is engineered for continuous operation and timely, accurate results—supporting you to reach your full potential today and be prepared for tomorrow. With an advanced user interface that is easy to use and VeriSmart Technology to support accuracy of testing, the ADVIA Chemistry XPT System predictably and consistently delivers timely, reliable results to meet expanding workloads. Simplified, Continuous Operation Simplify operation and training with the intuitive, icon-driven user interface. Extend walkaway times with concentrated reagents that provide high test capacity onboard. Quickly load most system fluids on the fly. Automate calibration, QC, startup, and shutdown. Consistent, Predictable Turnaround Time and Accuracy Offer a comprehensive chemistry menu of over 115 assays, including general and specialty chemistry, DAT, TDM, and specific proteins. Push productivity with a throughput of up to 2400 tests per hour (1800 photometric, plus 600 ISE). Control testing: STAT and specialty samples can always be front-loaded while an automation track is running. Designed for Automation Adapt and grow with direct connectivity to Siemens Healthineers and . Simplify your laboratory operations with connectivity to IT solutions including , , and . Increase productivity and efficiency with direct-from-track sampling and onboard aliquoting that allows samples to be immediately released to the next workstation. Do More with Less Reduce blood-draw requirements with micro-volume technology that uses a single 30 μL sample for up to 15 tests. Eliminate sample callback with automated, pre-programmable dilution, reflex, and rerun testing that uses an onboard aliquot. Improve workflow and accuracy with VeriSmart echnologies that perform hardware and software checks at all stages of sample processing.

Send Message
product image
Laboratory Testing Reagents

We are noticed amongst the well-known manufacturer and supplier in this domain, involved in providing Calibration Solution. This product is processed & formulated by our professionals utilizing superior grade chemicals in line with international quality norms. The offered product is obtainable in different grades with airtight packing in bottles as per the requirements of the clients. This product is tested at labs on numerous predefined standards of the industry before its final dispatch to the customers. Features: Safe usage Superior quality Easy to store Other Details: Calibration Solution Hamilton USA Make Ph / TDS / Cond / ORP / Redox in a Bottle of 500 ml NIST Traceable Certificate & 5 Year Shelf Life Product Details: Packaging Type Bottles Brand Hamilton Packaging Size 500 ml Color White Transparent Shelf Life 5 Years Certificate NIST Traceable

Send Message
product image
Instruments

We are the Leading Supplier of ORP Meter Calibration Solution. Our firm has gained huge recognition for providing a qualitative assortment of ORP Meter Calibration Solution that used much like pH values to determine water quality. Offered product is processed utilizing supreme class chemicals and leading techniques in adherence to the set norms of the industry. This product is well tested on diverse aspects so as to supply a pure range to customers. We offer this product in various grades to choose from. Our product is acknowledged among customers for its optimum quality. Features: Accurate formulation Highly effective Optimum quality Other Details: Calibration Solution for ORP Meter Cap - 480 ml Range - 475 mV, 263 mV, 86 mV With Eutech Certificate of Analysis ORP electrode ECFC7960201 B plastic body double junction gel filled Product Details: Usage Industrial Packaging Size 480 ml Grade Standard Technical Grade Packaging Type Bottle Range 475 mV, 263 mV, 86 mV Color White Transparent

Send Message
product image
Laboratory Testing Reagents

Product Description We are the Leading Supplier of Calibration Solution for pH TDS COND. The team of our skilled professionals is actively involved in providing a comprehensive array of Calibration Solution Salinity Cap. Our product is acclaimed in the industry owing to its purity & high effectiveness. This solution is processed under the direction of skilled professionals utilizing the optimum grade chemicals as per the set industry norms. Provided product is ideal for quickly performing the routine calibration required to maintain the robust performance of thermo scientific mass spectrometers. Features: Precise composition Longer shelf life Optimum quality Other Details: Calibration Solution for Salinity Cap - 480 ml, Range - 5 ppt, 25 ppt, 45 ppt CON603K Conductivity 0 to 200 m S/cm - Battery IP 54 Product Specification Usage Industrial Packaging Size 480 ml Grade Standard Reagent Grade Packaging Type Bottle Range 5 ppt, 25 ppt, 45 ppt Color Transparent Liquid

Send Message
product image
Urinalysis Analyzer

The Orinalyser U500 Urine Analyser is a Multi Strip Urine Reagent Strip Analyser. It is a reflectance photometer that analyzes the intensity and color of light reflected from the reagent areas of a urinalysis reagent strip. The analyser throughput is 500 tests per hour and the measuring cycle is 7 seconds per test. •500 tests/hour throughput •Large LCD touch screen offers simple menu navigation •Auto strip detection and alignment for better efficiency •Uniquely designed strip platform and waste tray unit for easy one-step cleaning •Autocalibration and waste disposal. •Auto flag for abnormal results •RS232C & USB port for data transfer

Send Message
product image
Laboratory Testing Analyzer

The ADAMS A1c, HA-8180T is a fully automated Glycohemoglobin analyzer based on HPLC (High Performance Liquid Chromatography) and is highly effective for ß-thalassemia testing. Measurement speed: 3.5 minutes/test Measurement Item as below HbA2 HbF HbA1c (Stable HbA1c, S-A1c), HbS, HbC, HbE and HbD can be detected. Column design with no more pre-filter change. Color LCD with reagent level, graphs on screen. Samples Whole blood or hemolysis sample Measurement items HbA1c(Stable HbA1c, S-A1c), HbA2 and HbF (HbS, HbC, HbE and HbD can be detected.) Reagents *1 ELUENT 80A, ELUENT 80B, ELUENT 80CT and HEMOLYSIS WASHING SOLUTION 80H Column *2 COLUMN UNIT 80T Measurement principle Reversed-phase cation exchange chromatography Detection method Dual-wavelength colorimetry (wavelengths measured: 420nm/500nm) Resolution 0.1% Ratio, 1 mmol/mol Measurement range *3 HbA1c : 3-20%, 9-195 mmol/mol HbA2 : 2-10% HbF : 0-100% Guaranteed measurement range *4 HbA1c : 4.2-12.9%, 22-117 mmol/mol HbA2 : 2.4-6.3% HbF : 0.1-14.3% Processing speed 210 seconds per sample Sample consumption Approx.14μL(whole blood) Sample container Blood collection tube (12.3 to 15mm diameter) × ( 75 to 100mm length) Sample cup(500μL) Sampling method Cap-Piercing Rack type ARKRAY racks Number of measurement samples One-way transportation (factory set) : Maximum 50 samples Loop transportation : Maximum 100 samples Column temperature Approx. 39℃ Display Color graphic LCD with backlight Memory capacity 500 test results ( including calibration results ) Built-in Printer Termal printer, 58mm thermal paper External output Serial 1 port (Can be optionally used as an Ethernet port.) Measurement conditions Temperature : 15-30℃ Humidity : 20-80% relative humidity (non-condensing ) Required sample volume Blood collection tube : Minimum 10mm away from the bottom Sample cup : 400μL or more Warm-up time Maximum 30 min. Dimensions 530(W)×530(D)×530(H)mm (Not including the hemolysis washing solution bottle) Weight Analyzer: Approx. 39kg, Sampler: Approx. 4kg Power supply AC100V-240V ±10% 50/60Hz Power consumption Max. 300 VA *1, *2 Reagents and column are sold separately from HA-8180T analyzer. *3 Error-free measurement ranges. *4 Guaranteed ranges for obtaining results equivalent to those from HA-8160 TP mode measurement. ※Design and specications may be changed without prior notice

Send Message
product image
Laboratory Testing Analyzer

The ADAMS A1c, HA-8180 is a fully automated Glycohemoglobin (HbA1c) analyzer based on HPLC (High Performance Liquid Chromatography). HbA1c is a good parameter for long-term blood glucose monitoring in patients suffering from diabetes mellitus. Measurement Speed: 48 sec/test for Fast Mode and 90 sec/test for Variant mode. Measurement items are as follows. HA-8180V, Fast Mode HbA1c (Stable HbA1c, S-A1c) and HbF HA-8180V, Variant Mode  HbA1c (Stable HbA1c, S-A1c) and HbF HbS and HbC separation and HbE and HbD detection can be performed. ・Column design with no more pre-filter change ・Economical - improved aluminium reagents for more efficient reagent supply ・Color LCD with reagent level, graphs on screen Specifications Configuration Main body, sampler (with sample tube spinning unit) and accessories Measurement objects Whole blood or hemolysis sample Column COLUMN UNIT 80 Reagents ELUENT 80A, ELUENT 80B, ELUENT 80CV and HEMOLYSIS WASHING SOLUTION 80H Measurement items Fast Mode HbA1c (Stable HbA1c, S-A1c) and HbF Variant Mode HbA1c (Stable HbA1c, S-A1c) and HbF (HbS and HbC separation and HbE and HbD detection can be performed) Measurement ranges *1 HbA1C: 3 - 20%, 9 - 195 mmol/mol HbF: 0 - 100% Guaranteed measurement ranges *2 HbA1C: 4 - 16%, 20 - 151 mmol/mol HbF: 0.3 - 5% Measurement principle Reversed-phase cation exchange chromatography Measurement wavelength 420 nm / 500 nm (Dual-wavelength colorimetry) Sample supply Sampler Resolution 0.1 % Ratio, 1 mmol / mol Processing speed Variant mode : 90 seconds / test Fast mode : 48 seconds / test Sample consumption Approximately 14 μL (Whole blood) Required sample volume Sample tube : Minimum 10 mm away from the bottom Sample cup : 400 μL or more Sample container Sample tube : (12.3/15 mm diameter) × (75 to 100 mm length) Sample cup: 500 μL Compatible rack type ARKRAY racks Number of measurement samples One-way transportation (factory-set) : Maximum 50 samples Loop transportation : Maximum 100 samples Column temperature Approximately 40°C Warm-up time Maximum 30 minutes Display Large color LCD with backlight Printer For use with 58-mm width thermal printer paper Memory capacity 900 measurement results (including calibration results) External output Serial 1 port (Can be optionally used as an Ethernet port.) Communication system RS-232C compliant (Switchable between one-way and two-way communications.) Transmission speed RS-232C : Selectable from 300, 600, 1200, 2400, 4800, 9600 and 19200 bps Ethernet: 10BASE-T Dimensions 530 (W) × 530 (D) × 530 (H) mm (Not including the hemolysis washing solution bottle) Weight Main body: Approximately 39 kg, Sampler: Approximately 4 kg Power requirements 100 - 240 V AC ± 10 %, 50 / 60 Hz Power input Maximum 300 VA *1 Error-free measurement ranges *2 Guaranteed ranges for obtaining results equivalent to those from HA-8160 VP mode measurement

Send Message
product image
Hematology

Product Description AutoCell Plus 3 Part WBC Differential Automated Hematology Analyzer Large Touch Screen Display Easy analysis of patient data on single screen ensuring efficient work-flow 10.4" color touch-screen Data + Hitogram Based Result 20 parameters numerical data 8 3 histo grams Results are displayed as group of "data + histogram" for each parameter enabling easier correlation. Dual Sample Mode Ft Small Sample Volume Just 9 pL whole blood required for test - Very useful for pediatric & geriatric patients where sample collection may be very difficult 20 pL Pre-dilution mode - Automatic dilution in case of capillary sample by analyser which minimizes manual dilution-related errors. Other Important Features: Direct access Clog removal key saves time for user by not needing to come back to main menu. Comprehensive built-in QC program for up to 10 lots with X -R, X B, X D CV value. Flexibility of dual calibration (Automatic 8 Manual calibration)allows user to calibrate the instrument according to his need to ensure the accuracy of measurements (results) Dual chamber for WBC Et RBC makes faster test results with more accurate & avoids cross-contamination Reagent depletion alarm for Lyse, Cleanser and Diluent, as optional function (Liquid Sensors) 10, 000 test results with histogram to meet all requirements Auto background measurement during start-up for ensuring trouble-free operation Internal thermal printer or facility to connect optional external printer RS232 interface & PC connectivity

Send Message

Still searching for
calibration results?