Jaipur
+918529833535

'best automated hematology analyzers'

Items tagged with 'best automated hematology analyzers'

product image
Hematology

Buy the Best Automated Hematology Analyzers – Acculab CBC 360 Neo. This Hematology Analyser Machine is Truly Automated for self-checking, background test, calibration, sampling, dilution, mixing, printing, dormancy, alarms, cleaning and maintenance. CBC 360 Neo is 3 part hematology analyzer from Accurex & is Automated for Walk-away Operations. Dual Chamber: Measurement of RBC / platelets & WBC / HGB in different chambers ensure accurate counting in a short time. The micro-aperture sizes of both the chambers are well designed to avoid error due to cell misclassification Automation for Walk-away Operation: Auto Self-check : Automatic aspiration of reagents & rinsing of tubings on startup Auto Blank : Background test is run automatically on startup Auto Print : Automatic printing of report with / without histogram Auto Sleep : Dormancy status is entered after a set period of non-operation Auto Alarms : Audio / visual alarms in case of system errors & abnormal results Auto Clean : Automatic rinsing options available to maintain the system Dual Chamber: Measurement of RBC / platelets & WBC / HGB in different chambers ensure accurate counting in a short time. The micro-aperture sizes of both the chambers are well designed to avoid error due to cell misclassification Specifications: Measurement principle: Electrical resistance for counting RBC, WBC & Platelets Colorimetric estimation of HGB at 540 nm Parameters: WBC, LY, MO, GR, LY%, MO%, GR%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR Throughput: 60 samples/hour Micro-aperture: WBC : 100 um RBC / PLT : 68 um Sample type: Whole blood or pre-diluted sample Sample volume: Whole blood (venous blood) : 10 ul Chamber: Pre-diluent (capillary blood) : 20 ul, Pre-diluent (capillary blood) : 20 ul Reagents: Dual chamber : RBC / Platelets & WBC / HGB Quality control: 4 QC options : L-J, X-B, X-R & X QC, Graphs plotted with 31 data points Data memory: Upto 100,000 (with histogram) Display: 10.4 inch LCD with 640 x 480 resolution Printer: Built-in thermal printer Interface: Support RS-232C, standard network port and USB; keyboard and mouse Operating environment: Temperature : 15˚C – 35˚C, Humidity : 85% RH Electrical specification: Voltage : AC 110V/230V 23V Frequency : 50/60 Hz, Power : 180W Fuse specification : 250V/3A Dimensions / Weight: 670 x 515 x 640 mm / 27.5 kgs Specification Acculab CBC 360 Neo – Fully Automated Hematology Analyzer Features: 3-part differentiation of WBC Automated for — self-checking, background test, calibration, sampling, dilution, mixing, printing, dormancy, alarms, cleaning and maintenance High processing speed : 60 samples/hour Multi-parameter estimation : 20 parameters categorized according to corpuscle type for easy reporting Direct command keys for Mode, Prime, Flush, Drain & Record / Print for faster operation Run / Standby indicator lights denote the analyzer status i.e. test is being run or analyser is ready to test Whole blood/ Pre-diluent indicator lights denote the sample type in use i.e. whole blood/ pre-diluent Dual sample mode with low sample volume: Whole blood (venous) mode : 10 ul; pre-diluent (capillary) mode : 20 ul Audio alarm indication for abnormal findings or system errors 4 QC methods : L-J, X-B, X-R & X QC Comprehensive QC graphs with 31 data points for each parameter Internal & external probe cleaning facility Dormancy mode available to reduce power consumption Memory : 100,000 (with histogram) Safety Information • Large 10.4 inch single screen color display of all 21 parameters and 3 histograms • Sequential arrangement of WBC, RBC & PLT parameters for convenient reporing •Easy to understand & icon-based arrangement of menu for fast and convenient testing Direction for Use • WBC Histogram: R1, R2, R3, R4 & RM indications on histogram show specific abnormalities in the histogram & the probable causes • Platelet Histogram: PM indication is given when the boundary between PLT & RBC is ill-defined thus avoiding misclassification Other Info High voltage cautery function is useful in disintegrating obstinate protein or serum clog in the tubing

Send Message
product image
Hematology

Product Description AutoCell Plus 3 Part WBC Differential Automated Hematology Analyzer Large Touch Screen Display Easy analysis of patient data on single screen ensuring efficient work-flow 10.4" color touch-screen Data + Hitogram Based Result 20 parameters numerical data 8 3 histo grams Results are displayed as group of "data + histogram" for each parameter enabling easier correlation. Dual Sample Mode Ft Small Sample Volume Just 9 pL whole blood required for test - Very useful for pediatric & geriatric patients where sample collection may be very difficult 20 pL Pre-dilution mode - Automatic dilution in case of capillary sample by analyser which minimizes manual dilution-related errors. Other Important Features: Direct access Clog removal key saves time for user by not needing to come back to main menu. Comprehensive built-in QC program for up to 10 lots with X -R, X B, X D CV value. Flexibility of dual calibration (Automatic 8 Manual calibration)allows user to calibrate the instrument according to his need to ensure the accuracy of measurements (results) Dual chamber for WBC Et RBC makes faster test results with more accurate & avoids cross-contamination Reagent depletion alarm for Lyse, Cleanser and Diluent, as optional function (Liquid Sensors) 10, 000 test results with histogram to meet all requirements Auto background measurement during start-up for ensuring trouble-free operation Internal thermal printer or facility to connect optional external printer RS232 interface & PC connectivity

Send Message
product image
Hematology

The BC-3600 Hematology analyzer features closed tube sampling via a single push button. A built-in large 10.4 inch color touchscreen allows maximum visibility. Hemoglobin analysis is performed using cyanide-free reagent. The analyzer processes up to 60 samples per hour and stores up to 40,000 results with histograms. The barcode reader and optional LIS connectivity enable seamless sample data transmission. Nearly all scheduled maintenance procedures are automated by touch buttons. The intuitive software enhances workflow efficiency and provides operators with a pleasant user experience. Key Features CBC plus 3-part differential, 16 parameters + 3 histograms 60 samples per hour, 1 min per CBC Closed tube sampling, minimize operational biohazard Built In diluent dispenser for predilution mode All-in-one CBC result screen display; results at a glance Touch button maintenance procedures One maintenance reagent only – probe cleaner Storage capacity of 40,000 results with histograms Uploadable QC files; ensure accuracy and time efficiency Parameters WBC, Lymph#, Mid#, Gran#, Lymph%, Mid%, Gran%, RBC, HGB, HCT,MCV, MCH, MCHC, RDW,PLT, MPV and histograms for WBC, RBC, PLT Principles Electrical impedance method for cell counting and Cyanide - free for hemoglobin Sample Volume Prediluted 20µL Whole Blood 21µL Carryover WBC/RBC/HGB≤0.5% PLT≤1.0% Connectivity 4 USB ports (for external printer, software upgrade, barcode reader,keyboard and mouse), LAN port (1), RS232 (1) Printout Thermal recorder, 50mm width paper, various printout formats, external printer (optional) Product Specification Brand Mindray Differential Type 3-Part Model Name/Number BC 3600 Display Type Large color touch screen Resolution 800x600 Usage/Application Hospital Throughput 60 samples per hour Power Supply AC 100-240V,50/60 +-1Hz Weight 62 lbs Dimension 16 in(W) x 18 in(H) x 18 in(D) Humidity 30%-85% Temperature 15 ~30 Deg C Minimum Order Quantity 1

Send Message
product image
Immunology Analyzer

Fully Automated Chemiluminescence Immunoassay Analyzer Introducing iFlash 1200, a chemiluminescence immunoassay analyzer that offers fully automated immunoassay analysis using Magnetic particle-based Direct Chemiluminescence technology. With a high throughput of up to 120 tests per hour and a first result available in just 13 minutes, iFlash 1200 is one of the fastest and most efficient immunoassay analyzers available on the market. The instrument features continuous STAT sample loading capacity with 16 sample positions, continuous reagents loading capacity with 15 reagent positions, and continuous loading of reaction vessels with a capacity of 500 cuvettes. Additionally, iFlash 1200 uses Acridinium Ester Labeled Direct Chemiluminescence for highly accurate and reliable results, and comes with ready-to-use reagents in convenient 2 x 50 tests pack size for simplified testing. Overall, iFlash 1200 is an innovative and versatile immunoassay analyzer that is perfect for laboratories that require high throughput and rapid turnaround times. iFlash 1200 chemiluminescence immunoassay analyzer Key Features: 1.Continuous loading of reagents with convenient pack size of 2 x 50 tests 2.Continous loading of 500 reaction cuvettes for longer walkaway time 3. 4 step magnetic separation for achieving high precision and quality results 4.Non contact vortex mixer-Highly Efficient technology to prevent carryover & cross contamination Additional information General Information Throughput : upto 120 tests/hour Time to First Results :13 minutes Detection Principle Magnetic particle Based Direct Chemiluminescence Chemiluminescence Label :Acridinium Ester Sample System Sample Position :16 sample position Types of Sample tube :Microcup & blood collecting tubes Sample Volume :5~150μL Reagent System Reagent Position :15 reagent positions with onboard refrigeration Reagent Carousel Temp :2-8 °C Reagent Detection :Reagent Level Tracking Reagent Pack : 2 x 50 tests Reagent Carousel Incubation Capacity :48 reaction vessels Incubation Temperature :37°C+-0.3°C Mixing System :Non-Contact Vortex Mixer Operating Conditions Power Supply :100~240V, 50/60HZ Power Consumption :600VA Temperature :10~30°C Weight :120 Kg Reagents iFlash 1200 reagents iFlash 1200 reagents Pack size 2 x 50 Tests 28 days On board reagent stability 28 days Calibration stability Built in Calibrators for all Parameters

Send Message
product image
Clinical Chemistry

Best Fully Automated Clinical Chemistry Analyzer – Sphera M from Accurex. This chemistry analyzer is made in Italy & provides Accurate, Precise and Rapid Testing Solution. Sphera M is a Compact, fully automated, open random-access analyzer. The Minimum reaction volume is 210 µl, Minimal < 1L/h water consumption, 80 reusable UV transmitting Bionex® plastic cuvettes, 8-step wash station. It has Removable refrigerated tray with 30 open reagent positions for 50 ml or 20 ml bottles. Multiple virtual reagent disks can be programmed. The Chemistry analyser also does Auto-wash of inner & exterior probe surface. QUALITY CONTROL & CALIBRATION QUALITY CONTROL: • Levey-Jennings plots and Westgard multi rules • Upto 3 QC levels per test • QC monitor and reports • Method statistics: Test counter, CV%, mean, graphical trend analysis CALIBRATION: • Method and reagent monitor (volumes, available tests, calibration, QC status) • Automatic pre-dilution for calibrators • Upto 8 calibrators per method • Auto recalculation of result using last calibration. UNIQUE SOFTWARE DESIGN AND ARCHITECTURE: • Software designed for touch screen use • Intuitive user interface • Continuous loading of samples and reagents • Random-access and STAT • Free choice of execution order • Extended walk-away capability • Results archive with cumulative charts • Programmable automatic start up routine • Multiple work lists INTERFACE: • Bi-directional LIS, ASTM, over ethernet port of the external PC • Positive identification of samples with internal barcode reader (optional) • Printing on any Windows 7®/8® compatible printer • Method defined washing programs SYSTEM PACKS FOR SPHERA™ Accurex has developed dedicated system packs for Sphera™. Our biochemistry reagents have been intensively evaluated and validated to achieve the highest performance in Sphera™. Accurex recommends the use of these system packs according to instructions and applications validated by Accurex. Safety Information 8-step wash station for thorough cleaning of each cuvette (Needles: 6 dispensing, 6 aspiration, 1 cleaning) • Two types of systemic and special washing solutions for removing obstinate probe residues Direction for Use QUALITY CONTROL • Levey-Jennings plots and Westgard multi rules • Upto 3 QC levels per test • QC monitor and reports • Method statistics: Test counter, CV%, mean, graphical trend analysis CALIBRATION • Method and reagent monitor (volumes, available tests, calibration, QC status) • Automatic pre-dilution for calibrators • Upto 8 calibrators per method • Auto recalculation of result using last calibration Other Info Accurex has developed dedicated system packs for Sphera™. Our biochemistry reagents have been intensively evaluated and validated to achieve the highest performance in Sphera™. Accurex recommends the use of these system packs according to instructions and applications validated by Accurex.

Send Message
product image
Hematology

Buy the Best 5 Parts Hematology Analyzer – ACCULAB CBC 560+. This Hematology Analyser Machine is an advanced and automatic hematology analyzer, comprising 5 parts, 29 parameters, and 3 histograms assay, offers throughput of 60 tests/hour. Features: Tri-angle laser scatter, Flow cytometry method, Impedance method for RBC and PLT counting and Cyanide-free method for HGB test along with 3D holographic scattergram to display the accurate 5 part differentiation of WBC. Equipped with a 14 inch touch screen and large storage capacity for 100,000 results, this hematology analyzer has interface of 4 USB ports, 1 LAN port Bi-direction LIS, support HL 7 protocol, Internal RFID reader. With CBC mode, CBC+DIFF mode, Venous whole blood, Capillary whole blood and Prediluted test mode, this hematology analyzer is an ideal unit for white blood cell counts, complete blood Measuring principle Tri-angle laser scatter, Flow cytometry method, Impedance method for RBC and PLT counting, Cyanide-free method for HGB test Sample volumes CBC+DIFF mode: ≤ 20 μl CBC mode: ≤ 10 μl Throughput 60 tests/hour Assay Items 29 parameters, 3 histograms Display 14 inch touch screen Storage 100,000 sample results, including histograms, scattergrams and patient information Parameter WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PCT,PDW, P-LCR, P-LCC, NEU%, LYM%, MON%, EOS%,BAS%,NEU#, LYM#, MON#, EOS#, BAS# 4 Research parameter: ALY%, ALY#, LIC%, LIC# Performance Item Linearity range Carry Over CV WBC 0-300 × 109/L ≤ 0.5% ≤ 2.0 % RBC 0-8.00 ×1012/L ≤ 0.5% ≤ 1.5 % HGB 0-250 g/L ≤ 0.5% ≤ 1.5 % PLT 0-3000 × 109/L ≤ 1.0% ≤ 4.0 % Interface 4 USB ports, 1 LAN port Bi-direction LIS, support HL 7 protocol, Internal RFID reader Power Consumption 400 VA Power Supply AC 220V±10%, 50/60Hz, 110V±10%, 60Hz Packaging dimension (W×D×H) 670 × 590 × 790 mm Gross Weight 53 kg Safety Information All the samples, controls, calibrators, reagents, waste and areas contacted with them are potentially biohazardous. Wear proper personal protective equipment (e.g. gloves, lab coat, etc.) and follow safe laboratory procedures when handling them in the laboratory.

Send Message
product image
Hematology

Fully Automatic Oscar Om 511 Hematology Analyzer, For Clinical, User Input: Touch Instrument Name Haematology Analyzer Usage/Application All Automation Fully Automatic Brand OSCAR Parameters CBC + 5 Diff Differential Type 5-Part Number Of Chambers 2 User Input Touch / Manual Number Of Parameters ALL Parameters Instrument Type 5 PART Cell Counter Model Name/Number OM-511 Type Of Blood Analyzer Fully Automatic Sample Mode All Method All Throughput 60 Samples Per Hour Display Digital Features Catalogs Attached Sample Volume 15ul Storage 1 Lac Results No. Of Reagents Used 2 Lyse 1 Diluent Accessories Keyboard ,Mouse ,Tubing Set ,Power Adaptor, Print Roll Calibration Automatic / Manual Chamber Type Double Chamber Depth Of Chamber 100un Detector Yes Dilution Ratio 1.0 Loading Pattern Manual Measuring Method Electric Impedance & Cytometric Measuring Principle Electric Impedance & Cytometric Measuring Range 2 SD Measuring Time 52 Sec Number Of Reading Channels 2 Number Of Squares 4 Operating Voltage 220 Power Supply 220 Reagent System Close with RFID Sample Type Whole Blood Slide Size 0.3un Test Volume 15ul Wavelength 546 Weight 20 Kg Zero Setting Blank Aperture Size RBC 80 , WBC 100 , Plt 60 Is It Portable Yes Measurement Range Mm Hr 60 Test Per Hour Portable Yes Reading Chambers 2 Direct Sample Yes Optical System Wavelength Optical Source Flow cell Height 470mm Point Of Care Yes Dimension 365x470x525mm Printer Yes - Internal Humidity 88% Operational Ambient Temperature 37% Atmospheric Pressure 85 kpa User Interface Yes Reliable Yes Minimum Order Quantity 1 Product Description Company : OSCAR MEDICARE PVT LTD Brand : OM-511 CBC 5 Part Hematology Products Specification : The Brand New Autometed 5-Part Differentials hematology analyzer. Try-angular laser scatter + flow cytometry for 5 Part WBC Counting. Whole Blood, Peripheral Blood, Pre-diluted blood. Throughput with 60 Samples / hour. 29 Parameters (Include 4 research Parameters 3 Reagents with orignal QC & Carlibrators

Send Message
product image
Hemostasis Analyzer

ECL 760 ECL 760 is an advanced Fully automated coagulation analyzer with seven detection channels providing operators with a compact easy-to-use system. Dedicated for mid-volume throughput labs, the ECL 760 been designed to optimize your productivity. ECL 760 is a blend of modernity and simplicity. Erba reagents oers a wide menu of test parameters for automated coagulation analyzers. KEY FEATURES ECL 760 uses the proven system of percentage intensity of light scatter at 640 nm LED. This optical system ensures early light stability, longer duration usage time and greater lamp life. It minimizes the interference of hemolysis, ictericity and lipemia, in samples at each assay, The system monitors the entire clotting process from reagent addition to complete clot formation with the generation of Clot curve. Clotting Tests  All clotting tests, such as Prothrombin Time, Activated Partial Thromboplastin Time, Fibrinogen, Thrombin time, Factors (II / V / Vll / X / Vlll / IX\ Xl / Xll), Lupus and Protein S are performed. Chromogenic Tests  Chromogenic tests use the colorimetric principle of measuring absorbance of light (405nm LED) by the test in a cuvette. Protein C and Antithrombin Illare some of the tests done by this method. Immunological Assay  The change in light intensity caused by the antigen antibody reaction is detected at 575 nm LED, as the change in the transmitted light.  D Dimer is the most common test performed

Send Message

Still searching for
best automated hematology analyzers?