Jaipur
+918529833535

'bbi low titre panel'

Items tagged with 'bbi low titre panel'

product image
Rapid Test

The OnSite HIV 1/2 Ab Plus Combo Rapid Test is a lateral flow immunoassay for the simultaneous detection and differentiation of HIV-1 and HIV-2 antibodies (IgG, IgM, IgA) in human serum, plasma or whole blood. 3rd Generation, double-antigen based test to increase the sensitivity in early detection Requires only 20 µL of specimen Use serum, plasma or whole blood Results available within 15 minutes to allow prompt action to be taken at the point of care Performance validated with BBI low titre panel and Chinese FDA HIV Ab panel Individually sealed foil pouches containing: One cassette device One desiccant Capillary tubes (20 uL) Sample diluent (REF SB-R0011, 5 mL/bottle) Package insert (instruction for use) CTK Products at a Glance Flyer Inserts TB-HIV Rapid Test Presentation U.S. CDC HIV Homepage: About HIV WHO: Health Topic for HIV U.S. CDC HIV Testing 101

Send Message
product image
Rapid Test

The OnSite Duo HSV-1/2 IgG/IgM Rapid Test is a lateral flow chromatographic immunoassay for qualitative detection and differentiation of antibodies (IgG and IgM) to herpes simplex virus 1 (HSV-1) and herpes simplex virus 2 (HSV-2) in human serum, plasma or whole blood. This test can be performed in 10 minutes by minimally skilled personnel without the use of laboratory equipment. This test is intended to be used by professionals as a screening test and provides a preliminary test result to aid in the diagnosis of infection with HSV-1 and/or HSV-2. The OnSite Duo HSV-1/2 IgG/IgM Rapid Test uses HSV-1 glycoprotein G1 and HSV-2 glycoprotein G2 for the specific detection and differentiation of IgG and IgM antibodies to HSV-1 and HSV-2 in serum, plasma and whole blood. An HSV-1 and/or HSV-2 IgM positive result indicates an active infection, which may be primary or recurrent. An HSV-1 and/or HSV-2 IgG positive result indicates a recent or past infection. However, a negative test result does not preclude the possibility of infection with HSV-1 and/or HSV-2. Any interpretation or use of this preliminary test result must also rely on other clinical findings as well as on the professional judgment of health care providers. Alternative test method(s) should be considered to confirm the test result obtained by this device. Clinical accuracy: 90.6% sensitivity and 91.4% specificity for anti-HSV-1 IgG detection 93.8% sensitivity and 96.0% specificity for anti-HSV-2 IgG detection 85.0% overall agreement for anti-HSV-1 IgM detection comparing to commercial ELISA 100% overall agreement for anti-HSV-2 IgM detection comparing to BBI Panel (PTH202) Positive rate on random clinical specimens:8% for IgG anti-HSV-1 and 4.9% for IgM anti-HSV-1 (n=10,000); 4.6% for anti-HSV-2 IgG and 1.7% for anti-HSV-2 IgM Cross reactivity: no cross reactivity with the following disease states or special conditions, respectively: palladium, H. pylori, Dengue, Malaria, Typhoid, Toxoplasma, Rubella, CMV, hCG, TB, HAV, HBV, HCV, HEV, HIV, ANA, HAMA, RF (up to 1,000 IU/mL) Interference: No interference was seen with Albumin 60 g/L , Hemoglobin 2 g/L, Bilirubin 20 mg/dL, Heparin 3,000 U/L, Creatinine 442 µmol/L, Salicylic acid 4.24 mmol/L, EDTA 3.4 µmol/L, Sodium citrate 8%, Glucose 55 mmol/L Shelf life: 24 months Individually sealed foil pouches containing: One cassette device One desiccant Capillary tubes (10 µL) Sample diluent (REF SB-R0203, 5 mL/bottle) Package insert (instruction for use) Individually sealed foil pouches containing: One cassette device One desiccant Capillary tubes (10 µL) Sample diluent (REF SB-R0203, 5 mL/bottle) Package insert (instruction for use)

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ cTn I/NT-proBNP Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA System for quantitative determination of cardiac Troponin I (cTn I) and N-terminal prohormone of brain natriuretic peptide (NT-proBNP) in human whole blood, serum or plasma. This test is used as an aid to assist in the diagnosis of myocardial infarction and suspected congestive heart failure. STORAGE AND STABILITY 1. Store the test kit at 4℃~30℃ up to the expiration date printed on package. 2. If removed from refrigerator, allow the test kit for 30 minutes to return to room temperature before testing. 3. Do not remove the Test Cartridge from the pouch until use. The Test Cartridge should be used within 1 hour once opened.

Send Message
product image
Clinical Chemistry

The ADVIA® 1800 Clinical Chemistry System pushes the limit of productivity. Its extensive menu allows integration of testing for clinical chemistry, drugs-of-abuse, therapeutic drug monitoring (TDM) and specific proteins such as cystatin C and CardioPhase® hsCRP. The ADVIA 1800 Clinical Chemistry System offers: Throughput of up to 1,800 tests per hour to keep pace with workload peaks 200 basic metabolic panels per hour to meet turnaround-time demands Large onboard reagent capacity and optional concentrated reagents to reduce interruptions Optimal standardization of reagents and systems for efficient consumable usage Refrigerated onboard storage of controls and reagents for extended stability and increased productivity Automation-ready design: no additional hardware required Features & Benefits The ADVIA 1800® Clinical Chemistry System pushes the limit of productivity in the core lab and meets the turnaround-time (TAT) goals of today’s laboratories. Its extensive menu allows integration of general clinical chemistry testing with testing for drugs-of-abuse, TDM, special chemistry, and specific proteins such as cystatin C and CardioPhase® hsCRP. Automation-ready design Point-in-space aspiration enables connectivity to a track, VersaCell® System. Redundant sample loading provides built-in backup and easy handling of non-routine samples. Direct sampling from track prevents tubes being detained at an analyzer and reduces aliquoting. Peak productivity Throughput of up to 1,800 tests per hour provides the speed to keep pace with workload peaks. Throughput of 200 basic metabolic panels per hour helps to meet turnaround-time demands. Automatic Sample Retain technology lets you perform reruns and dilutions without the need to retrieve primary tubes. Consolidate chemistry testing on one system with a comprehensive menu, consistent cycle times, speed, and open application capability. Total system reliability Minimal-maintenance ISEs Robust hardware and simplified software design, with automatic calibration validation and tracking Advances in reagent onboard stability, calibration frequency, interference reduction and assay linearity expansion Direct water connection Remote diagnostics and Inter-Laboratory Quality Control (ILQC) options Easy efficiency Large onboard reagent capacity and optional concentrated reagents reduce interruptions. High-resolution touchscreen delivers push-button operation. Reagent pause capability and onboard Sample Pause button make loading easy. Minimal maintenance requirements, including no-maintenance oil bath, reduce hands-on time. Sample integrity checking, include serum indices reporting, short-sample flagging, and clot detection, reducing the need for manual intervention.

Send Message
product image
Clinical Chemistry

With the built-in oxygen concentration monitoring system and effective cable management system, the HyPort R80 is capable of creating a reliable and streamlined ICU environment to ensure patient safety. Recovery The lighting system of the HyPort R80 aims to create a comfortable, near-natural light ICU environment to enhance patient recovery. 1234 1 Circadian Light Simulating 24-hour natural daylight change to reflect circadian rhythm. 2 Examination Light Up to 10,000 lux, 5-level adjustable illuminance meets various needs of head and abdominal examination. 3 Reading Light Effectively avoid invalid glare to meet the reading needs of rehabilitating patients. 4 Navigation Light Providing enough lighting with less glare for medical staff’s easy observation and intervention. Efficiency The HyPort R80 is a highly integrated bedside device management system that helps caregivers organize medical devices to meet various clinical needs. It makes efficient use of beside space with a series of easy-to-use designs, enabling a more efficient workflow for medical staff. Folding-shelf design Suitable for both portable ventilators and integrated ventilators. p46-s3-2-web Bag-valve-mask management Making sure bag valve mask is easy to access and ready for emergency situations anytime when needed. p46-s3-3-web Partition management The pump separation layout allows medical staff to easily identify infusion pumps and feeding pumps. p46-s3-4-web Smooth movement The advanced braking technology ensures stability of the column when moving. NextPrevious Variety The HyPort R80 has been designed to meet the demands of different ICU layouts to create a safer, more efficient and comfortable ICU environment with patient-centric design.ICU double room solution A Product Specification Usage/Application Hospital Brand Mindray Model Name/Number HyPort B80 Features 60 Degreepanel interface for easier plug-in of gas and electricity Color White Panel Interface 60 Degree Product Description Gas and electricity separated 60°panel interface for easier plug-in of gas and electricity Flexible movement of sliding and rotating of the distributions Additional accessories for better management of details Considerate lighting option Safer and more effective workflow Gas and electricity separated 60°panel for easier plug-in of gas and electricity Better management Customized drawer solutions Wire basket - dfferent size options available Cable management solutions

Send Message
product image
Clinical Chemistry

With cutting-edge LED technology, the HyLED 7 Series offers excellent luminous efficiency, heat-free light source, and incredible long service life, giving you total support in OR. Usage/Application Operation Theater Positioning Ceiling Mounted Model Name/Number HyLED 7 Series Brand Mindray Light Source Type LED Central illuminance at 1m distance 160,000 lux Light field diameter(at 1m distance) 180~300 mm Depth of illumination(L1+L2) 1,200 mm Correlated color temperature 4,350 K Color rendering index(Ra) 96 Color rendering index(R9) 97 Shadow dilution with tube 100% Shadow dilution with one mask 75% Shadow dilution with tube and one mask 70% Shadow dilution with two masks 55% Shadow dilution with tube and two masks 50% Ambient illumination 8,000 lux Bulb power consumption 85 W Power supply 100~240 VAC, 50/60 Hz Number of LED bulbs 32 Light head dimension 600 mm Integrated Camera Optional Carrier-arm Camera Optional HyLED 7 Series Contact Us With cutting-edge LED technology, the HyLED 7 Series offers excellent luminous efficiency, heat-free light source, and incredible long service life, giving you total support in OR. Efficient & Economic • Incredible long service time up to 60,000 hours • Central Illumination: 160,000 lux/130,000 lux • Adjustable light field diameter • Max. depth of Illumination : 1,200 mm • Low power consumption Original & Unique • Perfectly integrated into laminar flow (Certified per DIN-1946 Part 4) • Touch screen panel for easier control • 330° rotatable integrated HD/FHD camera • Ultra-thin design & excellent maneuverability • Ergonomic and compact design less than 12kg Ergonomic and Compact Design • The ultra-thin concentrically circular design for better hygiene. • DIN-1946 Part 4 certificated. (12-2008) Flexible Design • Combined with an Ondal spring arm maximizes mobility and ensures stability. • Ultra-thin light head with only less than 12 Kg. • Smooth, metal back cover of the light head. High Performance • With a minimum lifetime of 60,000 hours, each latest generation LED illuminates far longer than traditional light sources. • Easier and less costly maintenance: each LED bulb with individual circuit can be replaced respectively, which will minimize the maintenance cost. Easy and Intuitive Control • Traditional control panel • Touch screen panel(optional) Shadow-free The HyLED 7 Series surgical light inherits the advanced technology from the HyLED 9 series and shows excellent shadow management function. The professional shadow dilution experiment simulated extreme situations by using tubes and masks proved that Mindray HyLED 7 Series surgical light has sufficient illumination even in extreme situations. Camera System for Communication The camera system provides better communication and documenting solutions. The camera system integrated with the surgical lights also provides a platform for medical research purpose, teaching communication and video documenting. Digital video recorder Supporting external USB storage device Supporting HDMI/YPbPr/HD-SDI/DVI-D/VGA input signal Default with camera control function Supporting video recording from other medical devices source

Send Message
product image
Medical Equipment

Since the company was founded, Mindray has been continuously exploring new ways to improve diagnostic confidence. Powered by the most revolutionary ZONE Sonography® Technology, Resona 7’s new ZST+ platform brings ultrasound image quality to a higher level by zone acquisition and channel data processing. As well as the premium level image quality, Resona 7 also enhances clinical research capabilities with the revolutionary V Flow for vascular hemodynamic evaluation, and the most intelligent plane acquisition from 3D datasets for fetal CNS diagnosis. Combining the most intuitive gesture-based multi-touch operation and all the essential clinical features, Resona 7 is truly leading new waves in ultrasound innovation. With core platform advantages of ZST+ The channel data based ZST+ is an extraordinary innovation, representing an ultrasound evolution. Transforming ultrasound metrics from conventional beamforming to channel data based processing, ZST+ is able to deliver multiple imaging advances: Advanced Acoustic Acquisition, Dynamic Pixel Focusing, Sound Speed Compensation, Enhanced Channel Data Processing and Total Recall Imaging. Advanced features V Flow V Flow (Vector Flow) is a novel approach for vascular hemodynamic analysis. V Flow uses color coded vector arrows to indicate the velocity’s magnitude and direction of blood cells. With ultra-high frame rates, it provides extremely accurate and angle-independent visualization of complex vascular hemodynamic profiles. With comprehensive data information, V Flow is the most valuable tool for vascular clinical research. resona-7-fig3-1-pc UWN+ Contrast Imaging UWN+ (Ultra-Wideband Non-linear Plus) CEUS enables the Resona 7 to detect and utilize both the 2nd harmonic and non-linear fundamental signals, generating significantly enhanced images, resulting in greater sensitivity of minor signals and longer agent duration with lower MI. Forwarding smart to clinical intelligence The Resona 7 elevates clinical intelligence with a complete solution that enables clinicians to manage both routine and advanced studies more efficiently,consistently, and accurately, from acquisition to calculation. As an example, Smart Planes CNS shows exceptional intelligence in accurate diagnosis and analysis of the fetal central nervous system (CNS) Smart Planes CNS Mindray’s exclusive pioneering technology positions the Resona 7 as the industry’s first ultrasound system to allow fully automatic and accurate detection of the most significant planes and frequently used measurements of fetal CNS, leading to intelligent diagnosis, improved throughput, and reduced user dependence. Smart Planes CNS provides a user-friendly tool that greatly improves scanning efficiency through increased accuracy coupled with automated operation. With a simple button click on a 3D fetal brain volume image, the standard CNS scanning planes (MSP, TCP, TTP and TVP) and a range of related anatomical measurements (BPD, HC, OFD, TCD, CM and LVW) are obtained immediately. Smart Face Acquiring an optimal view of the fetal face in 3D ultrasound is cumbersome and time-consuming. In some cases, it is impossible to get rid of the occlusions such as cord, placenta, uterus and extremities. The new Resona 7 with Zone Intelligence provides a fast and intelligent optimization for fetal face with simply one-touch. It can immediately remove occlusions in the volume data, eliminate unwanted noise information, and generate an optimal view of the fetal face with minimal effort. Ergonomics The Resona 7 is designed around you. Gesture-based operation opens up a new trend in cart-based ultrasound with an agile, smart, and intuitive user experience beyond your expectations. Gel warmer’s three level temperature and swiveling angle adjustment of the control panel delivers great patient comfort and user convenience.

Send Message
product image
Rapid Test

The OnSite HBV-5 Rapid Test is a lateral flow chromatographic immunoassay for the qualitative detection of hepatitis B surface antigen (HBsAg), hepatitis B surface antibody (HBsAb), hepatitis B e-antigen (HBeAg), hepatitis B e-antibody (HBeAb), and hepatitis B core antibody (HBcAb) in human serum or plasma. It is intended to be used by healthcare professionals to aid in the diagnosis of infection with hepatitis B virus (HBV). Any use or interpretation of this preliminary test result must also rely on other clinical findings and the professional judgment of healthcare providers. Alternative test method(s) should be considered to confirm the test results obtained by this device. Panel format cassette to conveniently test for five targets at once Utilize all markers to help distinguish between acute and chronic infections Result in 15 minutes Individually sealed foil pouches containing: One cassette device One desiccant Plastic droppers Package insert (instruction for use) CTK Products at a Glance Inserts Poster U.S. CDC: hepatitis B Virus FAQs for Health Professionals WHO: Health Topic for Hepatitis

Send Message
product image
Clinical Chemistry

Find the Best Semi Automatic Biochemistry Analyzer from Accurex. Buy Acculab At 112 Plus (Semi Auto Biochemistry Analyzer) which is the best Biochemistry Machine with numerous features like Filter Check, Self-check operation for optical filters, Checks the absorbance of each of the 7 filters & free position, Ensures that all the filters are in good working condition. This Biochemistry Analyzer has Improved ergonomic touch screen display, ensures strain free viewing with End point, kinetic, fixed time & absorbance mode. FILTER CHECK • Self-check operation for optical filters. • Checks the absorbance of each of the 7 filters & free position. • Ensures that all the filters are in good working condition. WORKLIST • A unique facility by which a worklist can be prepared for every sample ID. • Printouts can be taken by sample ID or test parameters. • Print by ID : Ensures that no test is left out for a particular ID. • Print by Test : Ensures that all reagents / working solutions are prepared in correct volumes preventing wastage. • The system flags any test which is missed out for a particular ID, ensuring all assay panel is completed. LAMP SAVING • Lamp saving option available ensuring long lamp life. • The lamp can be turned off in case of sporadic sample workload ALARMS • Audio alarm is sounded when results are higher (S) or lower (L) than reference range ensuring that all abnormal samples are flagged for further review. • Improved ergonomic touch screen display, ensures strain free viewing • End point, kinetic, fixed time & absorbance mode • Single & bichromatic measurement • Memory : 3200 results • 112 programmable channels • Calibration modes – 1 standard / multi-point linear / multi-point non-linear • Easy-access maintenance chamber ensures efficient uptime management • Real-time reaction curve display • Anti-vibration & anti-disturbance optical system ensures highly accurate results • Option of 7 filters (340 – 630 nm) & 1 free position • Comprehensive quality control program with L-J graph • Lamp saving feature to prolong lamp life • Audible / visual alarm available • Easy-tear printer design Methodology: End point, kinetic, fixed time & absorbance Calibration: Single standard/multi-point linear/multi-point non-linear Programmable channels: 112 Memory: 3200 results Quality control: Comprehensive QC software with L-J graph Light source:Quartz-Halogen lamp 12V / 20W Photometric range: 0.0000 to 3.0000 Abs, Resolution : 0.0001 Abs : Drift : 0.002 Abs/hour Wavelength range: 7 standard filters: 340, 405, 492, 510, 546, 578, 630 nm & 1 free optional position ; Half Bandwidth < 8 nm : Stray light : < 1.0 % at 340 nm, Stainless steel body with quartz window; Optical path 10 mm Flowcell: Stainless steel body with quartz window; Optical path 10 mm Measuring volume: 32 μl Programmable aspiration volume:: 500-2000 μl Temperature control: Peltier elements : 25°C, 30°C & 37°C ±0.1°C Input: Ergonomic LCD touch screen display Printer: Built-in high speed thermal printer Interface: RS-232 serial port Dimension / Weight: 450 x 360 x 140 mm / 11.5 kgs Operating environment: Temperature: 15-30°C ; Humidity: 20-80 % Power requirement: AC 110-220 V ±10%, 50/60 Hz Safety Information • The position of the LCD display has been designed to reduce cervical (neck muscle) strain during continual use. • The aerial view display design makes it possible to view the screen from multiple perspectives, (standing or sitting, with equal clarity). Direction for Use • A unique facility by which a worklist can be prepared for every sample ID. • Printouts can be taken by sample ID or test parameters. • Print by ID : Ensures that no test is left out for a particular ID. • Print by Test : Ensures that all reagents / working solutions are prepared in correct volumes preventing wastage. • The system flags any test which is missed out for a particular ID, ensuring all assay panel is completed. Other Info • Improved ergonomic touch screen display, ensures strain free viewing • End point, kinetic, fixed time & absorbance mode • Single & bichromatic measurement • Memory : 3200 results • 112 programmable channels • Calibration modes – 1 standard / multi-point linear / multi-point non-linear • Easy-access maintenance chamber ensures efficient uptime management • Real-time reaction curve display • Anti-vibration & anti-disturbance optical system ensures highly accurate results • Option of 7 filters (340 – 630 nm) & 1 free position • Comprehensive quality control program with L-J graph • Lamp saving feature to prolong lamp life • Audible / visual alarm available • Easy-tear printer design

Send Message

Still searching for