Jaipur
+918529833535

'average function'

Items tagged with 'average function'

product image
Glucometer

Accu-Chek® Guide Blood Glucose Meter Surprisingly Clever Diabetes is complex. Your testing doesn’t have to be Item Description Diabetes is complex. Your testing doesn't have to be with the Accu-Chek® Guide blood glucose monitoring system. With a spill resistant SmartPack® vial, a strip that lets you place a small drop of blood anywhere along the end, and an app that automatically logs results to your phone, it's a surprisingly simple way to manage your diabetes. Benefits and Features Simple to log results without a paper logbook - automatically logs results right to a mySugr app on your smartphone Simple to take just one strip - spill-resistant SmartPack vial lets you take one and spill none Simple to dispose off used test strips - push-button strip ejector means you don't have to touch used strips Simple to see, day or night - strip port light for testing in daytime, nighttime or anytime Simple to be more accurate - delivers advanced 10/10 accuracy for reliable results you can trust1,2,3 Meter Specifications Models: Accu‑Chek Guide wireless blood glucose meter Serial number: Unique serial number etched into meter back Sample claims: Capillary: Yes Venous: ROW = Yes Arterial: ROW = Yes Non-fingerstick sample claim ROW: Palm, forearm, upper arm Measuring principle: FAD glucose dehydrogenase (GDH) Measuring time: Less than 4 seconds Measuring conditions: 4°C to 45 °C (39°F to 113 °F) Storage conditions: -25 °C to +70 °C (-13 °F to +158 °F) Hematocrit range: 10 to 65% Humidity range: 10 to 90 % Altitude independence: 0 to 3,094 m (10,150 ft) Memory capacity: Up to 720 measurements with date and time; 32 control measurements Test averages: 7, 14, 30 and 90 days Data transfer wireless connectivity: using Bluetooth Smart Low Energy Dimensions: 80 x 47 x 20 mm (L x W x H) Weight Approximately: 40 g with batteries Display: Large backlit LCD display with full-text capabilities Beep tone: Yes (factory setting ON) Batteries: (2) 3-volt lithium coin cell type CR2032 Auto power off: 15 seconds after removing a test strip; 90 seconds otherwise Blood volume: 0.6 μL Measuring range: 10 to 600 mg/dL Sample types: Capillary, venous, arterial and neonate Sample dosing: Capillary fill function; suitable for AST Test strip stability 18 months after production date: Test strips are stable (even after opening) until the expiry date printed on the test strip vial. Note: Test strip container must be tightly closed after each strip is removed. Storage temperature : 4 °C to 30 °C (39 °F to 86 °F)

Send Message
product image
Biochemistry Analyzer

Overview A fully automated POC Auto Dry Biochemistry Analyzer called Mispa Chem Dx, With Just 3 to 4 drops (100ul) of whole blood to test up to 19 General and Special chemistry tests in less than 12 minutes. Mispa Chem Dx works on absorption spectroscopy where a change in absorbance is detected by an absorption spectrum and an algorithm is used to calculate the end concentration of the sample in the reagent dry disc. The reagent disc consists of lyophilized reagent beads, diluent, and calibration details in the QR code. The reagent disc contains an intelligent internal quality control system IQC which continuously monitors the disc function to ensure reaction stability and optimal disc performance, IQC is the engine that drives the Mispa Chem Dx accurately and precisely Low Sample Consumption Easy to Use Maintenance Free Accurate Result Disposable reagent disc Sample volume: 100µl Testing time: 12 minutes / sample Temperature: 37°C ± 0.3°C Resolution: 0.001Abs Absorbance: 0-3.0Abs Sample type: Heparinized whole blood, serum, plasma (heparin) QC&Calibration: IQC (Intelligent Quality Control/Calibration) Work condition: Temperature:10-30°C Humidity: 30%-70% Testing method: End point, kinetic, fixed time, turbidmetry etc Light source: 12V/20W, Halogen tungsten lamp with life span over 2500 hours Power supply: AC 100V-240V, 50-60Hz Display: Android 7.0 inch 800*480, multi-point capacitive touch screen Storage: 500,000 results Printer: Built-in thermal printer Interface: 4 USB ports, 1 LAN port Dimension: 315*375*475mm. 4.2kg(N.W.), 7kg(G.W.)

Send Message
product image
immunoassayReagents

Cortisol Rapid Quantitative Test The Finecare™ Cortisol Rapid Quantitative Test is a fluorescence immunoassay for quantitative determination of Cortisol in human serum, plasma or whole blood. The test is used as an aid to the screening of adrenal dysfunction and assessment of the treatment effect. STORAGE AND STABILITY 1. Store the test kit at 4~30℃ up to the expiration date printed on package. 2. If removed from refrigerator, allow the test kit for 30 minutes to return to room temperature before testing. 3. Do not remove the test cartridge from the pouch until use. The test cartridge should be used within 1 hour once opened.

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ T3 Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA System for quantitative determination of Triiodothyronine (total T3) in human serum, plasma or whole blood. The test is used as an aid to the assessment of thyroid function. STORAGE AND STABILITY 1. Store the test kit at 4℃~30℃ up to the expiration date printed on package. 2. If removed from refrigerator, allow the test kit for 30 minutes to return to room temperature before testing. 3. Do not remove the Test Cartridge from the pouch until use. The Test Cartridge should be used within 1 hour once opened.

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ T4 Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA System for quantitative determination of Thyroxine (Total T4) in human whole blood, serum or plasma. The test is used as an aid to the assessment of thyroid function. STORAGE AND STABILITY 1. Store the test kit at 4℃~30℃ up to the expiration date printed on package. 2. If removed from refrigerator, allow the test kit for 30 minutes to return to room temperature before testing. 3. Do not remove the Test Cartridge from the pouch until use. The Test Cartridge should be used within 1 hour once opened.

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ TSH Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA System for quantitative determination of thyroid stimulating hormone (TSH) in human whole blood, serum or plasma. This test is used as an aid to assist in the assessment of pituitary gland and thyroid function. STORAGE AND STABILITY 1. Store the test kit at 4℃~30℃ up to the expiration date printed on package. 2. If removed from refrigerator, allow the test kit for 30 minutes to return to room temperature before testing. 3. Do not remove the Test Cartridge from the pouch until use. The Test Cartridge should be used within 1 hour once opened.

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ fT4 Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA Meters for quantitative determination of free thyroxine (fT4) in human whole blood, serum or plasma. The test is used as an aid to the assessment of thyroid function. STORAGE AND STABILITY 1. Store the test kit at 4℃~30℃ up to the expiration date printed on package. 2. If removed from refrigerator, allow the test kit for 30 minutes to return to room temperature before testing. 3. Do not remove the Test Cartridge from the pouch until use. The Test Cartridge should be used within 1 hour once opened.

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ fT3 Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA Meters for quantitative determination of free triiodothyronine (fT3) in human whole blood serum or plasma. The test is used as an aid to the assessment of thyroid function STORAGE AND STABILITY 1. Store the test kit at 4℃~30℃ up to the expiration date printed on package. 2. If removed from refrigerator, allow the test kit for 30 minutes to return to room temperature before testing. 3.Do not remove the Test Cartridge from the pouch until use. The Test Cartridge should be used within 1 hour once opened.

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ FSH Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA System for quantitative measurement of follicle-stimulating hormone (FSH) in human whole blood, serum or plasma. This test is used as an aid to evaluate the ovarian functions in clinical. STORAGE AND STABILITY 1. Store the test kit at 4℃~30℃ up to the expiration date printed on package. 2. If removed from refrigerator, allow the test kit for 30 minutes to return to room temperature before testing. 3. Do not remove the Test Cartridge from the pouch until use. The Test Cartridge should be used within 1 hour once opened.

Send Message

Still searching for
average function?