Jaipur
+918529833535

'autozyme alkaline phosphatase activity'

Items tagged with 'autozyme alkaline phosphatase activity'

product image
Clinical Chemistry

Autozyme Alkaline Phosphatase 60 Diagnostic Reagent (Pack Size : 12 x 5 ml) from Accurex. Alkaline Phosphatase 60 are used in the diagnosis of hepatobiliary disorders and bone disease associated with increased osteoblastic activity. Alkaline Phosphatase high levels may be a sign of a liver problem or a bone disorder Alkaline Phosphatase 60 reagent is set for determination of Alkaline Phosphatase activity based on kinetic method using p-nitrophenyl phosphate (p-NPP), the reagent is a Highly stable reagent & its activity can be determined in just 2.5 minutes. About Autozyme Alkaline Phosphatase is a reagent set for determination of Alkaline Phosphatase activity based on kinetic method using p-nitrophenyl phosphate (p-NPP) Autozyme Alkaline Phosphatase is a single reagent system using one step procedure Autozyme Alkaline Phosphatase has one step reconstitution. It involves dissolving substrate tablet in diluent Autozyme Alkaline Phosphatase is a Highly stable reagent Autozyme Alkaline Phosphatase activity can be determined in just 2.5 minutes Pack Size : 12 x 5 ml Principle The working solution is stablə for 21 days at 2- 8°C. The working solution should be prepared and stored in the dark (working solution bottle) provided.This is critical because the reagent is light sensitive. It should therefore be kept away from direct light. Alkaline Phosphatase cleaves p-nitrophenyl phosphate (p-NPP) into p-nitrophenol and phosphate. p-nitrophenol is a yellow color compound in alkaline medium and absorbs light at 405 nm. The rate of increase in absorbance at 405 nm. is proportional to Alkaline phosphatase activity in specimen. Quality Control To ensure adequate quality control, it is recommended that each batch should include normal and abnormal commercial reference control serum. It should be realized that the use of quality control material checks both instrument and reagent functions together. Factors which might affect the performance of this test include proper instrument function, temperature control, cleanliness of glassware and accuracy of pipetting. Other Details The kit should be stored at 2-8°C and is stable till the expiry date indicated on the label. The working solutions of Non Prostatic Acid Phosphatase & Total Acid Phosphatases are stable for 7 days at 2-8°C.

Send Message
product image
Clinical Chemistry

Autozyme Alkaline Phosphatase 300 Diagnostic Reagent from Accurex (Pack Size : 30 x 10 ml). Alkaline Phosphatase reagent is used for determination of Alkaline Phosphate activity based on kinetic method using p-nitrophenyl phosphate (p-NPP). Alkaline Phosphatase is a single reagent system using one step procedure & Alkaline Phosphatase activity can be determined in just 2.5 minutes & is is a Highly stable reagent. Alkaline Phosphatase cleaves p-nitrophenyl phosphate p- NPP in the presence of magnesium ions to form p nitrophenol & phosphate. About Method – p-NPP-DEA Buffer – Kinetic reaction with 60 seconds lag phase – Easy reconstitution : Tablet + Diluent – High liquid stability : 21 days Autozyme Alkaline Phosphatase is a reagent set for determination of Alkaline Phosphate activity based on kinetic method using p-nitrophenyl phosphate (p-NPP) Autozyme Alkaline Phosphatase is a single reagent system using one step procedure Autozyme Alkaline Phosphatase has one step reconstitution. It involves dissolving substrate tablet in diluent Autozyme Alkaline Phosphatase is a Highly stable reagent Autozyme Alkaline Phosphatase activity can be determined in just 2.5 minutes Principle Alkaline Phosphatase cleaves p-nitrophenyl phosphate p- NPP) in the presence of magnesium ions to form p nitrophenol and phosphate. The intensity of the yellow color formed is directly proportional to the Application alkaline phosphatase activity in the specimen and measured kinetically. Quality Control To ensure adequate quality control, it is recommended that each batch should include normal and an abnormal commercial reference control serum. It should be realized that the use of quality control material checks both instrument and reagent functions together. Factors which might affect the performance of this test include proper instrument function, temperature control, cleanliness of glassware and accuracy of pipetting. Other Details Two liquid reagent systems. Stable till the expiry date indicated on the label when stored in 2-8°C.

Send Message
product image
Clinical Chemistry

Acid Phosphatase Diagnostic Reagent (Pack size: 8 x 1 ml) from Accurex. Acid Phosphatase is used in accordance with ISO 14189 to detect acid phosphatase from Clostridium perfringens. Autozyme Acid Phosphate reagent is set for determination of Acid Phosphatase activity based on Kinetic method using a-naphthyl phosphate. In acidic pH of the buffer system, the reagent hydrolyses a-naphthyl phosphate to a-naphthol & phosphate. Accurex has gained considerable expertise in manufacturing & marketing of In-vitro Diagnostic reagents. About Autozyme Acid Phosphate is a reagent set for determination of Acid Phosphatase activity based on Kinetic method using a-naphthyl phosphate Autozyme Acid Phosphate is a single reagent system using one step procedure Autozyme Acid Phosphate can be determined in just 8 minutes at 37 degree C Acid Phosphate can be used on any Spectrophotometer, Discrete semi automated and Automated Analyzer. Programme can be designed for any specific analyzer upon request. Pack Size : 8 x 1 ml Principle In acidic pH of the buffer system, Acid Phosphatase hydrolyses a-naphthyl phosphate to a-naphthol and phosphate. The o-naphthol is then coupled with Diazotized Fast Red TR to form a Diazo dye which has strong absorbance at 405 nm. The increase in absorbance is directly proportional to the level of acid phosphatase in serum. The addition of L-Tartrate inhibits prostatic acid phosphatase but does not inhibit other isoenzymes. The activity of Prostatic Acid Phosphatase is obtained by subtracting the result of Non prostatic Acid phosphatase (Determination with Tartrate) from Total Acid Phosphatase (without tartrate). Quality Control To ensure adequate quality control it is recommended that each batch should include a normal and an abnormal commercial reference control serum. It should be realized that the use of quality control material checks both instrument and reagent functions together. Factors which might affect ne performance of this test includes proper instrument function, temperature control, cleanliness of glassware and accuracy of pipetting.

Send Message
product image
Clinical Chemistry

Ready to use liquid stable reagents. Pack sizes cater to specific customer needs. High quality reagents manufactured to international standards. Categories: Clinical Chemistry, Reagents Description Reagents Technical Information KITS Albumin Alkaline Phosphatase AST/SGOT Bilirubin Direct Calcium CK-NAC Creatinine GGT LDL Direct Magnesium Total Protein Uric Acid ALT/SGPT Amylase Bilirubin Total Bilirubin Total & Direct Cholesterol CK-MB Glucose HDL Direct LDH-L Phosphorus Triglycerides Urea Kinetic (Rate BUN) Lipase information every single reagents has a diffrent price 1 pack single price.

Send Message
product image
Clinical Chemistry

utozyme Albumin 300 Diagnostic Reagent from Accurex. Albumin 300 is used for determination of albumin in serum or plasma based on BCG method. Autozyme Albumin is a single reagent system which is ready to use, Albumin is linear up to 6 gm% & can be determined in 1 minute at room temperature. Serum albumin in the presence of Bromocresol-green under acidic condition forms a green coloured complex. Albumin normal range is 3.4 to 5.4 g/dL (34 to 54 g/L). About Autozyme Albumin is a reagent set for determination of albumin in serum or plasma based on BCG method Autozyme Albumin is a single reagent system, ready to use. Autozyme Albumin is linear up to 6 gm% Albumin can be determined in 1 minute at room temperature The shelf-life of Autozyme Albumin is 18 months Pack Size : 2 x 50 ml Principle Serum albumin in the presence of Bromocresol-green under acidic condition forms a green coloured complex, The absorbance of this complex is proportional to the albumin concentration in serum or plasma. Quality Control To ensure adequate quality control, it is recommended that each batch should include a normal and an abnormal commercial reference control serum,. it should be realized that the use of quality control material checks both instrument and reagent functions together. Factors which might affect the performance of this test include proper instrument function, cleanliness of glassware and accuracy of pipetting. Other Details The reagents are for in vitro diagnostic use. BCG reagent and standard should be stored at temperature indicated on the bottle label.

Send Message
product image
Clinical Chemistry

Autozyme Albumin 100 Diagnostic Reagent (Pack Size : 2 x 50 ml) from Accurex. Albumin reagent is used for determination of albumin in serum or plasma based on BCG method, can be determined in 1 minute at room temperature. BCG reagent and standard should be stored at temperature indicated on the bottle label. Accurex has gained considerable expertise in manufacturing & marketing of In-vitro Diagnostic reagents. Serum albumin in the presence of Bromocresol-green under acidic condition forms a green colored complex. Albumin normal range is 3.4 to 5.4 g/dL (34 to 54 g/L). About Autozyme Albumin is a reagent set for determination of albumin in serum or plasma based on BCG method Autozyme Albumin is a single reagent system, ready to use. Autozyme Albumin is linear up to 6 gm% Albumin can be determined in 1 minute at room temperature The shelf-life of Autozyme Albumin is 18 months Pack Size : 2 x 50 ml Principle Serum albumin in the presence of Bromocresol-green under acidic condition forms a green coloured complex, The absorbance of this complex is proportional to the albumin concentration in serum or plasma. Quality Control To ensure adequate quality control, it is recommended that each batch should include a normal and an abnormal commercial reference control serum,. it should be realized that the uSe of quality control material checks both instrument and reagent functions together. Factors which might affect the performance of this test include proper instrument function, cleanliness of glassware and accuracy of pipetting. Other Details The reagents are for in vitro diagnostic use. BCG reagent and standard should be stored at temperature indicated on the bottle label.

Send Message
product image
Clinical Chemistry

The HumaStar 300SR is the latest member of HUMAN's clinical chemistry systems. Based on the proven hardware and software quality of HumaStar 100/200 it uses the time-tested system reagent kits of HumaStar 600 with perfectly matching methods, calibrators and controls. Throughput: up to 300 tests/h Sample positions: 60 Reagent positions: 40 Prefilled and validated system reagents 2 kit sizes per assay available Open channels: 3 Low water consumption (< 3 l/h) Intuitive and powerful software Multi-language: English, Spanish, French Intuitive and powerful software > Full traceability to reagents (e.g. lot & bottle), calibrations, users and settings > Searchable result database > Onboard and calibration stability monitoring > Automatic outlier detection and unit conversion > Method specific wash options > Designed for touchscreen Flexible system reagent concept > Plug & run HumaStar system reagents > Ready-to-use and available in two kit sizes > Usable for HumaStar 300SR and HumaStar 600 > Prefilled barcoded reagent bottles > Validated assay settings for highest quality > Up to 56 days reagent onboard stability > High quality reagents “Made in Germany” Eco-friendly ProClean 2.0 Technology > Minimal carry-over – dual solution wash station > Low water consumption – less than 3 l/h > Separation and reduction of biohazard waste Easy and efficient operation > Multi-step cuvette wash station for reaction cuvettes > Pre and post dilution for long walk-away time > Bottle cap holder prevents bottle mix-ups and saves time > Quick user- and service-friendly maintenance HUMAN‘s reagent production facility In Magdeburg, Germany we produce our reagents in accordance with the latest quality standards, guaranteeing consistent quality at the highest level. HUMAN Gesellschaft für Biochemica und Diagnostica mbH Max-Planck-Ring 21 · 65205 Wiesbaden · Germany Tel. +49 6122-9988-0 · Fax +49 6122-9988-100 · e-mail: human@human.de · www.human.de Immune Status anti-Streptolysin-O, Complement C3 and C4, CRP, Immunoglobulins IgA, IgG, IgM Liver Panel Albumin, Alkaline Phosphatase, Bilirubin Total and Direct, Cholinesterase, gamma-GT, GOT (ASAT), GPT (ALAT), Total Protein Kidney Panel Calcium, Creatinine, Cystatin-C, Inorganic Phosphorus, Magnesium, Microalbumin, Potassium, Sodium, Urea/BUN, Uric Acid, Urinary Total Protein Arteriosclerosis Cardiac Risk Assessment Cholesterol, HDL-/LDL-Cholesterol, Homocysteine, Triglycerides Anemia Iron, Total Iron Binding Capacity, Transferrin Pancreatic Tests alpha-Amylase, Lipase, Pancreatic Amylase Water & Electrolyte Balance Albumin, Chloride, Potassium, Sodium, Total Protein Cardiac Panel CK-NAC, CK-MB, GOT (ASAT), GPT (ALAT), Homocysteine, LDH Diabetes Glucose, HbA1c, Microalbumin, Triglycerides, Urinary Total Protein Prostata Acid Phosphatase HumaStar 300SR Broad range of clinical chemist

Send Message
product image
Instruments

The NB350 neonatal noninvasive ventilator is specially designed for neonatal ventilation, equipped with comprehensive NIV modes to provide reliable non-invasive respiratory support to meet the various needs of neonatal respiratory management. EasySync™ Technology The patented EasySync™ technology analyzes multi-channel parameters including gas flow and pressure without additional sensors, enabling accurate detection of spontaneous breath and improving synchrony in SNIPPV. The EasySync™ technology leads to a good synchronization performance comparable to electrical activity of the diaphragm (Edi). IOC (Intelligent Oxygen Control) The oxygen saturation of neonates tends to fluctuate, requiring caregivers to frequently adjust ventilator’s FiO2 settings. IOC (Intelligent Oxygen Control) achieves a closed-loop FiO2-SpO2 control by maintaining the patient’s SpO2 within the predetermined range, which reduces the workload of caregivers and improves patient safety. Integrated SpO2 monitoring for neonates in real time.1 Automatically adjust FiO2 setting by adaptive algorithm.2 Steadily maintain the SpO2 of neonates within the preset target range. Comfortable and Reliable Patient-interface The specialized patient-interface for the NB350 comes with a variety of sizes to fit for different clinical applications and patients. The ergonomic design with soft, skin-friendly material fully enhances the comfort of neonates throughout therapies. Bonnet/Headgear The bonnet/headgear integrate a fixings lot (seat) for pressure generator to avoid misposition and disconnection of patient-interface. Skin-friendly and breathable bonnet/headgear. Durable headgear hook-and-loop fastener allows easy and quick re-adjustment of the patient-interface. Infant Jet™ Pressure Generator Adjustable nasal prong/nasal mask positioning to adapt different facial orientations. Specifically designed to facilitate Coanda effect, significantly reducing respiratory resistance. Related Articles

Send Message
product image
Rapid Test

The OnSite Troponin I Combo Rapid Test is a lateral flow chromatographic immunoassay for the qualitative detection of cardiac Troponin I (cTnI) in human serum, plasma or whole blood at a level equal to or higher than 1 ng/mL. It can be performed within 15 minutes by minimally skilled personnel, and without the use of laboratory equipment. The OnSite Troponin I Combo Rapid Test is intended to be used by healthcare professionals as an aid in the diagnosis of acute myocardial infarction (AMI). Any use or interpretation of this preliminary test result must also rely on patient’s symptoms and the professional judgment of a physician. A more precise test method such as an instrument method must be used to confirm the test result obtained by this device. Normally the level of cTnI in the blood is very low. cTnI is released into the blood stream in forms of free cTnI and cTnI-C-T complex at 4-6 hours after myocardial cell damage. The elevated level of cTnI could be as high as 50 ng/mL during 60-80 hours after AMI and remains detectable for up to 10-14 days post AMI. Therefore, circulating cTnI is a specific and sensitive marker for AMI. Clinical performance: Relative Sensitivity: 95.8% (95% CI: 91.5-97.9%) compared to a reference CLIA Relative Specificity: 99.7% (95% CI: 98.8-99.9%) Analytical sensitivity: The detection limit of cTnI is 1.0 ng/mL or greater in serum, plasma or whole blood specimen Cross-reactivity: No cross reactivity with 10 µg/mL skeletal muscle TnI, 2,000 ng/mL cardiac muscle TnT, 20 µg/mL cardiac muscle Myosin Dose hook effect: No hook effect was observed for cTnI at concentrations up to 3,521 µg/mL Interference: No interference was seen with 20 mg/dl Acetaminophen, 20 mg/dl Acetylsalicylic acid, 10.5 g/dl Albumin, 20 mg/dl Ascorbic acid, 1,000 mg/dl Bilirubin, 20 mg/dl Caffeine, 800 mg/dl Cholesterol, 200 mg/dl Creatinine, 20 mg/dl Gentistic acid, 1,000 mg/dl Hemoglobin, 600 mg/dl Oxilic acid, 1,600 mg/dl Triglycerides Shelf life: 24 months Individually sealed foil pouches containing: One cassette device One desiccant Plastic droppers Sample diluent (REF SB-R3002, 5 mL/bottle) One package insert (instruction for use) CTK Products at a Glance Insert MedlinePlus: Troponin Test Poster

Send Message

Still searching for
autozyme alkaline phosphatase activity?