Jaipur
+918529833535

'automatic recognition'

Items tagged with 'automatic recognition'

product image
Hematology

At Mindray, we pride ourselves on our dedication and experience in developing better solutions for small labs. Our new 3-part hematology analyzer is the culmination of that effort. It provides small labs with more confidence in results and less turnaround time. Features CBC+3-DIFF, 20 parameters +3 Histograms Throughput: up to 30 samples per hour 8.4 inch TFT touch screen Only three reagents needed Open vial sampling Large storage capacity: up to 50,000 samples Original QC, calibrators and reagents Automation Fully Automatic Instrument Name Hematology Analyzer Brand Mindray Differential Type 2-Part Usage/Application Clinical Number Of Chambers 1 Model Name/Number BC-10 Power Source Electric Voltage 240 V Frequency 50 Hz

Send Message
product image
Hematology

At Mindray we pride ourselves on our dedication and experience in developing better solutions for small labs. Our new line of 3-part hematology analyzers is the culmination of that effort. Compact yet powerful, full featured yet affordable, the BC-20s is what a 3-part analyzer should be. Features CBC+3-DIFF, 19 parameters+3 histograms Throughput:40 samples per hour Intuitive operation system with 8.4 inch TFT touch screen Open vial sampling 200,000 results storage with histograms Original QC, calibrators and reagents Product Specification Instrument Name Haematology Analyzer Model Name/Number BC20s Usage/Application Laboratory Brand Mindray Automation Fully Automatic Operation Mode Fully Automatic

Send Message
product image
Hematology

At Mindray, we pride ourselves on our dedication and experience in developing better solutions for small labs. Our new 3-part hematology analyzer is the culmination of that effort. It provides small labs with more confidence in results and less turnaround time. Features CBC+3-DIFF, 21 parameters+3 Histograms Throughput: up to 60 samples per hour 10.4 inch TFT touch screen Only three reagents needed Open vial sampling Large storage capacity: up to 400,000 samples Original QC, calibrators and reagents Product Specification Automation Fully Automatic Instrument Name Hematology Analyzer Brand Mindray Usage/Application Clinical Differential Type 3-Part Number Of Chambers 2 Number Of Parameters LYM Model Name/Number BC-30s User Input Touch Voltage 240 V Frequency 50 Hz Power Source Electric

Send Message
product image
Hematology

BC-6800 Today, laboratories not only need more reliable routine CBC plus 5-part diff WBC testing by way of high processing speed, but are also looking for options that extend the analyzer's output in form of Reticulocytes, Nucleated RBCs, Fluorescent Platelet counts etc. for wider clinical application and research. On the other hand, they are restricted by limited budgets. BC-6800 can help to meet all these needs just perfectly and even exceed the expectations. Additional parameters for further clinical applications IMG(#,%) parameters provide information about immature granulocyte, including promyelocytes, myelocytes and metamyelocytes. HFC*(#,%) parameters represent high fluorescent cell population, such as blasts and atypical lymphocytes. RET(#,%) extend valuable help in the differential diagnosis and/or therapeutic monitoring of anemias. IRF is parameter concerning immature reticulocytes, which can assist in early diagnosis of anemia and monitoring the bone marrow response to therapy. InR*(#,‰) are parameters regarding infected red blood cell. The red blood cells may infected by plasmodium, which can cause malaria. * means research parameters SF Cube Technology SF Cube is a pathbreaking technology for reliable blood cell analysis, including WBC differential, Reticulocytes and NRBC with efficient flagging. After reaction with proprietory reagents, the targeted blood cells undergo 3D analysis using information from scatter of laser light at two angles and fluorescence signals. The 3D scattergram builds the power to better identify and differentiate blood cell populations, especially to reveal abnormal cell population undetected by other techniques. Minimizing interference to ensure more accurate results NRBCs are counted in a dedicated channel by SF cube method, which automatically corrects total WBC count and 5-part Diff results when NRBCs are detected. The Focusing Flow-DC method minimizes the interference traditionally encountered in DC technology to produce near gaussian histograms. PLT-O result avoids the interference from microcytic and fragmented RBCs, large platelets and/or platelet clumps by fluorescent stain, and enhances the results accuracy and sensitivity. High automation to minimize the workload Throughput for 125 tests/hour, autoloader for 100 sample tubes capacity Bi-directional LIS with HL7 or ASTM communication protocol Customizable re-exam rules allow users to define their re-exam criterion according to lab’s practice

Send Message
product image
Hematology

The advanced BC-6800Plus not only provides more reliable routine CBC plus 5-part DIFF results, but also has a higher throughput of up to 200 samples per hour. Based on the new SF Cube technology platform, the BC-6800Plus could provide more reliable blood cell results and abnormal cells flagging results with anticipated warning messages, exceeding clinicians’ expectations and setting a new standard for blood analysis. SF Cube Technology With the newly designed opticals and reagent systems, the SF Cube technology can help doctors to better differentiate the clusters of cells, which is the key to revealing more abnormal cells. NRBC result in every CBC In WNB scattergram, BC-6800Plus provides NRBC, Basophils and WBC-N* results. It means that the actual number of NRBCs can be measured in routine CBC, if they are present in the sample. Basophils are counted in this counting channel with NRBC results. Basophil and NRBC results are generated on BC-6800Plus without extra reagent or cost. NLR parameter in each CBC+DIFF Neutrophil-to-lymphocyte ratio (NLR) is calculated by dividing neutrophil count by lymphocyte count, usually from peripheral blood sample. In laboratory medicine, NLR is used as a marker of subclinical inflammation. According to clinical studies, NLR can be used as a prognostic factor of severe illness in COVID-19 patients. More accurate RET and PLT-O result By utilizing the new fluorescent dye, the reticulocytes and platelets are more specific stained with stronger fluorescent signal, that brings more reliable reticulocyte and platelet results. Automatic Rerun & Reflex Should the sample results trigger the criteria, the sample rack can automatically step back for a “rerun” or “reflex” check. 200 test/hour BC-6800Plus can load up to 100 samples at a time and offers a throughput of up to 200 tests per hour.

Send Message
product image
Hematology

The BC-5390 is a 5-part Auto Hematology Analyzer that delivers high productivity, better accuracy and improved patient care, without sacrificing your budget. The analyzer utilizes the power of three mainstream technologies: laser scatter, flow cytometry, and chemical dye, to provide more accurate clinical information. The BC-5390 has been approved by FDA. Features Robust capacity and functionality Its throughput of 60 samples per hour saves your time, and the capacity of 40 autoloading tubes can extend your walk-away time. More reliable test result.The new reagent, with better anti-aging capacity, helps better differentiate Eosinophils from Neutrophils in the DIFF scattergram, even on samples with high density of Eosinophils. The analyzer is empowered by the fluid sensing technology to detect clot, bubble and insufficient sample, ensuring accurate sample aspiration. Flexible sample aspiration With different holder adapters, the analyzer supports three analysis modes - venous whole blood mode, pre-diluted mode and capillary whole blood mode. Product Specification Model Name/Number BC-5390 Operation Mode Fully Automatic Usage/Application Hospital Brand Mindray Capacity 40 autoloading tubes Throughput 60 samples per hour

Send Message
product image
Clinical Chemistry

The SAL 6000 modular system delivers fast throughput and powerful integration across immunoassay and chemistry systems. Broad assays can be tested with one sample tube, which can maximize operation efficiency and increase lab productivity. Product Description SAL 6000 Modular System delivers fast throughput and seamless integration of CL-2000i Chemiluminescence Immunoassay System and BS-800 Modular System. In conjunction with the SPL 1000 Sample Processing System, this scalable platform not only provides optimized workflow, it also offers satisfactory operator experience. Features · Seamless integration, workflow optimization · Uniform software interface, easy of operation · One tube sampling, flexible to test · Technology and quality heritage · Flexible scalability, on-site upgrading · Comprehensive test menu Product Specification Automation Fully Automatic Brand Mindray Model Name/Number SAL 6000 Assays Clinical Chemistry Power Supply 220 V Usage/Application Hospital Frequency 50 Hz

Send Message
product image
Rapid Test

STANDARD F HbA1c FIA performs quantitative analysis on glycosylated hemoglobin in whole blood samples using fluorescence immunochromatography. As STANDARD F Analyzer has been enhanced in its performance by using fluorescent substance, accurate quantitative test results can be obtained using with this product. ntented Use This product performs quantitative analysis on glycated hemoglobin in the whole blood samples. Advantage Able to perform accurate quantitative analysis using fluorescent substance Hb S, Hb F, Carbamylated Hemolgobin without interference phenomenon Automatic strip recognition by reading the information stored in 2D barcode IFCC / NGSP certified Specification Specimen Whole blood Test time 5 minutes Specimen volume 5 µl CV% <3%

Send Message
product image
Rapid Test

STANDARD F Chikungunya IgM/IgG FIA qualitatively analyzes Chikungunya virus specific IgM and IgG antibodies in serum, plasma and whole blood using fluorescent immunoassay. Screening test results can be obtained within 15 minutes with high sensitivity and specificity. Intented Use This product performs qualitative analysis on Chikungunya virus specific IgM and IgG antibodies in serum, plasma and whole blood. Advantage Able to perform qualitative analysis with high sensitivity and specificity by using fluorescent substance Objective result - Eliminates the subjectivity of a visual result Automatic strip recognition by reading the information stored in 2D barcode

Send Message

Still searching for
automatic recognition?