Jaipur
+918529833535

'aution screen'

Items tagged with 'aution screen'

product image
Laboratory Testing Reagents

ARKRAY's AUTION Sticks(AUTION Sticks 10EA, 10PA, AUTION SCREEN) represent an enormous investment of company time and resources in producing the most advanced urine test strip for the medical profession. AUTION Sticks help ensure accurate measurements both visually and automatically. Covers all items necessary for urine testing. A maximum of 10 items can be measured simultaneously. Choose the combination which best suits your testing needs. Choice of visual measurement or automatic measurement on an exclusive analyzer.

Send Message
product image
Urinalysis Analyzer

The AUTION ELEVEN AE-4020 is intended for the qualitative and/or semi-quantitative measurement of several physiological markers in urine: Glucose, Protein, Bilirubin, pH, Blood, Urobilinogen, Ketones, Nitrite, Leukocytes, Creatinine, Albumin, Specific Gravity, P/C (Ratio of Protein to Creatinine) and A/C (Ratio of Albumin to Creatinine). These measurements are used for screening of kidney disease, liver disease, diabetes mellitus and urinary tract infection in general screening populations. Compact Design: 210(W) x 328(D) x 164(H) mm / Approx. 3.6 kg Processing speed: 514 samples per hour (maximum processing mode: 7 second interval) Auto-start function: Measurement starts automatically when a strip is set on the tray. Test strip can be placed either from the left or the right side. Maximum 11 parameters and color tone can be measured simultaneously by special test strips designed and made by ARKRAY. *Some products including test strips may not be available in all countries. Please check with your local Arkray representative or distributor about product availability in your area. Sample Urine Test Strip / Reagent pack AUTION Sticks / Uriflet S / AUTION SCREEN Measurement item GLU, KET, BIL, NIT, PRO, URO, pH, BLD, LEU, ALB, CRE, Specific Gravity, color tone Measurement range Test strip: As Rank table Color tone: As Color tone classification chart Measurement method Test strip method Dual-wavelength reflection photometric method (single wavelength for BLD) Measurement wavelength 4-wavelength LED (430, 565, 635, and 760 nm) Test strip reaction time 60 seconds Processing speed 514 samples per hour (maximum processing mode: 7-second interval) Display Custom LC display (icons are used) Built-in printer 32-digit thermal printer (58 mm width) External output Conforms to RS-232C standard (serial) Option: Ethernet Memory capacity 520 measurement results Temperature correction Auto-correction by the internal temperature sensor (between 10 to 30 °C) S. G. correction Auto-correction by pH values Chromaturia correction Auto-correction by the color tone correction section on test strips Operating environment Temperature: 10 to 30 °C; Humidity: 20 to 80% R.H. (non-condensing) Measurement environment Temperature: 10 to 30°C; Humidity: 30 to 60% R.H. (non-condensing) *Temperature correction function used DC power requirements(To instrument) 12 Vdc 3 A AC power requirements(To AC adapter) 100-240 Vac 50-60 HZ ,1200 mA Voltage fluctuation allowance is ±10% Power consumption Max. 45 VA Dimensions 210 (width) × 328 (depth) × 164 (height) mm Weight Approx. 3.6 kg

Send Message
product image
Urinalysis Analyzer

High Performance "Full Automated System" Color Touch Panel for good usability 7 inch WVGA color touchscreen with high operability displays measurement results, instrument conditions and operating instructions. "Sample delivery system" enables micro volume samples to be measured As the sample is drawn through the nozzle and delivered correctly and quantitatively to each pad of the strip, the micro volume samples (minimum 1mL) can be measured easily. No cross contaminations are found on the reagent portions despite high sample volume. Sample Urine Test items Glu, Pro, Bil, Uro, Ket, pH, Nit, Bld, Leu, S.G., Alb, Cre(Alb/Cre ratio, Pro/Cre ratio can be calculated), turbidity and color tone Wavelength 5 LED wavelengths (430, 500, 565, 635, 760nm) Measurement principle Test strip :Dual-wavelength reflectance method (One-wavelength for Bld) Specific gravity :Reflection refractometryColor hue :Light-transmission measurementTurbidity :Light-scattering measurement method Test strip AUTION Sticks (10EA & 10PA) , Uriflet S 11UA Reaction time Approximately 60 seconds Throughput 225 samples per hour Strip storage Maximum 400 strips (200 strips x 2 feeder boxes) Required sample volume Normal, STAT measurement: Minimum 2 mL Small volume measurement: Minimum 1 mL Sample consumption Normal, STAT measurement: Maximum 0.90 mL Small volume measurement: Maximum 0.45 mL Sample container Sample tubes (length: 95 - 110 mm, diameter: ø14.0 - 15.8 mm) Maximum sample load 100 samples (Circulation) Data memory Normal, STAT, small volume measurement: 2500 tests Control measurement: 200 tests Check measurement: 50 tests Trouble list: 100 tests Display Large color liquid crystal display (800 × 480 dots) Built-in printer 58-mm width printer paper (24 digits) External output 1 port (Replaceable with the optional Ethernet terminal) Communication method RS-232C compliant (Switchable between one-way and two-way) Measurement environment Temperature: 10 - 30°C; Humidity: 30 - 60% RH (No condensation) Power requirements 100 - 240 V AC (Maximum power line fluctuation of ±10%), 50/60 Hz Power consumption 150VA (Maximum) Dimensions 530 (W) × 530 (D) × 550 (H) mm (including the sampler) Weight Main body: Approximately 36 kg Sampler: Approximately 4 kg

Send Message
product image
Urinalysis Analyzer

Palm-sized, fitting easily into a doctor's bag or uniform pocket. The printer can be separated from the "PocketChem" analyzer, leaving it with a weight of just 180g. Corrective features for obtaining accurate test results Accurate readings can be obtained by eliminating the effects of chromaturia using the color correction test pad, by compensating measurements for the temperature of the surrounding environment using a built-in temperature sensor and by correcting specific gravity based on pH readings. Palm-sized analyzer driven by two batteries The analyzer is detachable from the printer. The analyzer is really portable and mobile. Simple operation. Just press the start button Measurement is performed by simply pressing the start button and placing a test strip. Test results can be simultaneously viewed on the display and printed out from the printer. Reliable test results with Creatinine correction Even with the use of spot urine, test results are reliable and are not affected by urine dilutions or concentrations. The P/C ration or A/C ratio is effective for the screening of renal diseases. Sample Urine Test strips AUTION Sticks/ Uriflet S (9UB)* / AUTION SCREEN * Except devices with 10V specifications Measurement items GLU (glucose), PRO (protein), BIL (bilirubin), URO (urobilinogen), S.G. (specific gravity), BLD (blood), PH (pH), KET (ketones), NIT (nitrite), LEU (leukocytes), CRE (creatinine) and ALB (albumin). Measurement principle Test strip: Dual wavelength reflectance method. (one wavelength for BLD measurement) Measurement wavelengths 3 wavelengths LED (565, 635, 760 nm) Sample supply method Manual dipping Measurement capacity 50 tests per hour Test strip reaction time About 60 seconds per test Measurement types Normal measurement and check measurement Display Custom LCD that displays information including type of test strip, measurement number (up to 4 digits), patient ID (up to 13 digits) and test results. Operator panel Panel sheet that provides 14 buttons including numeric buttons and start button. Memory capacity Test results for 100 samples External output Compliant with RS-232 C Measurement environment Temperature: 10 to 30 °C; Humidity: 30 to 60 % R.H. (non-condensing) *Temperature correction function used Dimensions 124 (W) x 81 (D) x 36 (H) mm Weight 180 g (without batteries) Power supply Instrument only: Two AA alkaline batteries or AC adapter Instrument with printer: AC adapter 7.5 V 3 A Power consumption 3 W Printer specifications Printer Thermal recording printer Printer paper High color development thermal paper (W 58 mm x φ26 mm) Dimensions 125 (W) x 133 (D) x 36 (H) mm Weight 180 g (without printer paper) Power supply AC adapter 7.5 V 3 A Power consumption 20 W

Send Message
product image
Clinical Chemistry

Best Semi Automatic Biochemistry Analyzer AT Smart from Accurex. AT SMART is a Biochemistry/Clinical Analyzer with a user-friendly and the human interface is via touch screen. It measures the optical densities of samples & calculates the sample concentration which are used for biochemical investigation. This Biochemistry Machine operates from near UV to visible range. Semi Auto Analyzer AT SMART is CE certified and has undergone rigors testing before being delivered to customers. About •SMART MAINTENANCE •SMART LIS •SMART INVENTORY MANAGEMENT REDUCED ERRORS: IT allows for the accurate collection of data, automated workflows & minimized waste. SAVES TIME: Patient monitoring can be done in real-time, saves engineers visiting time. BETTER PATIENT EXPERIENCE: A connected laboratory system creates an environment that meets each patient’s needs. INSTRUMENT BREAKDOWN MANAGEMENT: Real-time data helps to monitor instrument performance. ONLINE REACTION CURVES: • Real time reaction curve with special • Flagging gives confidence in patient reports. INTELLECTUAL SOFTWARE: • User friendly Device. • 150 Direct access test keys gives freedom to select parameters easily. • Availability of different assay modes. DRY BATH INCUBATOR: • Dry bath incubator with 12 test tube positions • Mini size with 15 minutes start up time FEATURES: •Remote access & monitoring via Internet •150 test parameters •Built-in thermal printer to print results, enzymatic curves and standard calibration curves •Large graphic display with real time graph display for enzymatic reaction •Touch screen interface with dynamic test access key SPECIFICATIONS: Methodology- • Absorbance • Endpoint with standard, factor, sample blank & diffrential • Two-point (fixed time) and multi point kinetics • Multi standard calibration • Mono or bi-chromatic reading • Turbidimetry Optical System- • Principle: photometry • Range of measurement: 0.0-3.0A • Spectral range selection: Automatic via filter wheel • Filters: 340, 405, 505, 546, 578 and 630 nm plus two free position • Bandwidth:10nm (+/- 2nm) • Light source: Life Long Halogen lamp • Blanking: Automatic • Detector: Silicon Photodiode Photometer- • Peltier regulated 25ºC, 30ºC and 37ºC • Flow cell of 18 µ L • Continuous flow system with peristaltic pump • Programmable Sipping Volume Memory- • 150+ User Defined Test Programs • 1000 test results in instrument memory and unlimited test resultresult storage via cloud • Reagent Blank • 2 Level of QC Quality Control- • Levy-Jennings chart using westgard’s rules • 30 Normal and abnormal QC values for selected test User Interface- • Graphic LCD back Lit 240×64 pixels • Touch Screen input • Data port and cloud connectivity • Type : Graphic thermal printer Power & Dimensions- • Voltage : 220 V • Frequency : 50 Hz • Maximum power : < 150 VA • Maximum relative humidity : 75% • Compact form factor • Weight: < 6kgs Safety Information Precautions • Instrument should be operated only by authorised or trained personnel • For any reasons, unauthorised personnel should not be engaged for servicing or removing the cabinet • Power source should be regulated either by voltage stabilizer or regulated power back up (UPS). If inverter is been used, please ensure there exists a voltage stabilizer • Reagents recommended by the company to be preferably used • Flow cell needs to be rinsed regularly with the company recommended flow cell cleaning solution • User is requested not to use any other pointing devices other than being supplied by company while operating touch screen • The operating environment should be clean and protected from direct sunlight • During the day at the end of the work, it should be ensured that flow cell is always filled with distilled water • During transport / longer duration of shut down, th Direction for Use Please ensure that the power source is properly grounded and voltage between Line and Ground is less than 2V AC – 5V AC. • Please ensure that the instrument is placed on a firm table, clean environment, and sufficient ventilation space. • Switch On the instrument. • Instrument will run its own internal diagnostic routines, to ensure proper working of critical functions. • Allow the instrument to stabilize for 10 minutes. • During the stabilization time, please wash the flow cell with cleaning solution and distilled water for at least two times. • During shut down, ensure that the flow cell is cleaned with flow cell cleaning solution and rinsed thoroughly using distilled water. • For overnight shutdown, please ensure flow cell is filled with distilled water. • Cover the instrument with the given dust cover Other Info GENERAL INFORMATION While installing and setting up the instrument, few safety warnings and general precautions described in the further sections must be observed. A. Power Supply : • Power source should be grounded and have either servo stabilizer or regulated power back up • Power cord should be CE , CSA and UL marked • Voltage : 115 – 230 Volts ± 10% 50 – 60 Hz • Grounding: Make sure that electrical power source is properly grounded.

Send Message
product image
Rapid Test

Buy AccuTest COVID-19 IgG/IgM Rapid Test (Pack of 10 Tests) Online. COVID-19 IgG/IgM Rapid Test Kit is a qualitative immuno chromatographic assay for the detection of IgG & IgM antibodies produced against COVID-19 virus in human whole blood/Serum/ Plasma. COVID-19 IgG/IgM Rapid Test Kit is only intended for initial screening and reactive samples should be confirmed by a supplemental assay. Intended Use: COVID-19 IgG/IgM Rapid Test Kit is a qualitative immuno chromatographic assay for the detection of IgG & IgM antibodies produced against COVID-19 virus in human whole blood/Serum/ Plasma. COVID-19 IgG/IgM Rapid Test Kit is only intended for initial screening and reactive samples should be confirmed by a supplemental assay. SUMMARY & TEST DESCRIPTION: COVID-19 [Coronavirus Disease- 2019] is an infectious disease caused by SARS-CoV2 [Severe Acute Respiratory Syndrome coronavirus 2] virus, which is a contagious, novel strain of CoronaVirus that emerged from Wuhan, China in December 2019, which grew as a pandemic threatening human survival across the globe. The virus is thought to be of zoonotic origin and likely to have spread from large seafood and animal markets by human-animal contact in the city of Wuhan, where consumption of such products is in large. The virus causes respiratory infection with symptoms including fatigue, fever, shortness of breath, respiratory failure, renal failure and death. Patients can become infected with SARS-CoV-2 virus by person-person contact (through contact with a contaminated environment or person). The young and old (and other immune-compromised individuals) are most at risk of serious complications; however, approximately 20% of those infected can develop a critical condition. COVID-19 IgG/IgM Rapid Test device utilizes Anti-human IgG and Anti-human IgM antibodies as the capture molecules. COVID-19 Recombinant Antigens-colloidal gold conjugate are used as detection antigen. Intended Use: COVID-19 IgG/IgM Rapid Test Kit is a qualitative immuno chromatographic assay for the detection of IgG & IgM antibodies produced against COVID-19 virus in human whole blood/Serum/ Plasma. COVID-19 IgG/IgM Rapid Test Kit is only intended for initial screening and reactive samples should be confirmed by a supplemental assay. SUMMARY & TEST DESCRIPTION: COVID-19 [Coronavirus Disease- 2019] is an infectious disease caused by SARS-CoV2 [Severe Acute Respiratory Syndrome coronavirus 2] virus, which is a contagious, novel strain of CoronaVirus that emerged from Wuhan, China in December 2019, which grew as a pandemic threatening human survival across the globe. The virus is thought to be of zoonotic origin and likely to have spread from large seafood and animal markets by human-animal contact in the city of Wuhan, where consumption of such products is in large. The virus causes respiratory infection with symptoms including fatigue, fever, shortness of breath, respiratory failure, renal failure and death. Patients can become infected with SARS-CoV-2 virus by person-person contact (through contact with a contaminated environment or person). The young and old (and other immune-compromised individuals) are most at risk of serious complications; however, approximately 20% of those infected can develop a critical condition. COVID-19 IgG/IgM Rapid Test device utilizes Anti-human IgG and Anti-human IgM antibodies as the capture molecules. COVID-19 Recombinant Antigens-colloidal gold conjugate are used as detection antigen. PRECAUTIONS & WARNING 1. This package insert must be read completely before performing thetest. Failuretofollow directions in insert may yield inaccurate test results. 2. Test results should be read between 10 and 15 minutes after aspecimenisapplied to the sample well. Results read after 20 minutes may giveerroneousresults.3. Do not open the sealed pouch until you are ready to conduct theassay.Onceopened, the cassettes should be used immediately. 4. Do not use expired devices. 5. Bring all reagents to room temperature (15-30°C) prior to use. 6. Do not mix components from different kits. Use only the buffer suppliedalongwith the kit. 7. Wear protective clothing and disposable gloves while handling thekit reagentsand clinical specimens. Wash hands thoroughly after performing thetest. 8. Do not smoke, drink, or eat in areas where specimens or kit reagents arebeinghandled. 9. Dispose of all specimens and materials used to performthe test as biohazardouswaste. 10. Handle the negative and positive controls in the same manner as patientspecimens for operator protection. 11. Do not perform the test in a room with strong air flow, i.e. an electricfanorstrong air-conditioning. 12. Do not touch result window. 13. Use only for in-vitro diagnostic purpose.

Send Message
product image
Rapid Test

Buy AccuTest Vitamin D Rapid Card Test (10 Tests) Online from Accurex. The Vitamin D test kit consists of 25 AccuTest Vitamin D individually packed test, devices in foil pouches, 25 pipettes for collecting 10 ul of whole blood, 25 lancets, 1 Buffer Vial (Buffer 5 mL) with stabilizers and, thimerosal, 1 Package Insert. Vitamin D Fast test kit is a rapid chromatographic immunoassay for the semi quantitative detection of Vitamin D levels in human blood/serum. This Vitamin D test provides a preliminary screening test result. INTENDED USE AccuTest Vitamin D is a rapid chromatographic immunoassay for the semi quantitative detection of Vitamin D levels in human blood/serum. This assay provides only a preliminary screening test result. A more specific alternative chemical method must be used in order to obtain a confirmed analytical result. The performance characteristics of this assay have not been established in a pediatric population. PRINCIPLE AccuTest Vitamin D is based on the principle of a competitive enzyme immunoassay. The assay is based on the competition for 25-OH Vitamin D present in blood/serum sample and Vitamin D present on the test line for fixed number of antibody-gold conjugate. Depending upon the concentration of Vitamin D in blood/serum, there will be free antibody-gold conjugate molecules that will bind to Vitamin D on the test strip and will show a colored line in the test line zone. A control line is present in the test window to work as procedural control. PRECAUTIONS 1. For in vitro diagnostic use only. 2. The test is designed for use with human blood/serum only. 3. Reagents must be at room temperature (8⁰C – 30 ⁰C). 4. Do not use if test device packaging is open or damaged. 5. Do not use the product beyond expiration date. 6. Handle all specimens as potentially infectious. Proper handling and disposal methods should be used according to good laboratory practices. 7. Read test results for 10 minutes as required. Results may deteriorate and may not be consistent after 10 minutes. 8. In order to avoid variable results, mix the blood sample thoroughly. 9. A serum sample subjected to repeated freeze thaw cycles may give variable results Direction for Use PROCEDURE 1. Remove the cassette from the sealed pouch and place it on a hard flat surface with the view window facing up (use the cassette as soon as possible). 2. Using a micropipette, add 10 µl of whole blood or 5ul of serum sample directly into the rectangular specimen well (marked with Red drop) of the cassette. 3. Add 3 full drops of Buffer into the square buffer well of the cassette (Do not move the cassette after addition of buffer). 4. Let the cassette sit for 10 minutes and read your results immediately. Results may deteriorate after the 10 minute mark. Other Info STORAGE AND STABILITY The test device should be stored at 8 ⁰C – 30 ⁰C and will be stable until the expiration date stated on the package. The product is humidity sensitive and should be used immediately after being open. INTERPRETATION OF RESULTS Match the color of the test line with the chart provided.

Send Message
product image
Rapid Test

Buy AccuTest Typhoid IgG/IgM Rapid Card Test (5 Tests) Online from Accurex. The Typhoid IgG/IgM Rapid Test is used for detection & differentiation of anti-Salmonella typhi (S. typhi) IgG and IgM in human whole blood / serum / plasma. This Typhoid test is used as a screening test and as an aid in the diagnosis of infection with S. typhi. Salmonella typhi bacteria causes typhoid Typhoid fever, typhoid symptoms symptoms are likely to develop gradually – appearing one to three weeks after exposure to the disease. There are various typhoid treatment & typhoid vaccine which can be opted after the detetction of Typhoid. Typhoid fever is caused by S. typhi, a Gram-negative bacterium. Worldwide an estimated 17 million cases and 600,000 associated deaths occur annually. Patients who are infected with HIV are at significantly increased risk of clinical infection with S. typhi. Evidence of H. pylori infection also presents an increased risk of acquiring typhoid fever. 1-5% of patients become chronic carrier harboring S. typhi in the gall bladder. The clinical diagnosis of typhoid fever depends on the isolation of S. typhi from blood, bone marrow or a specific anatomic lesion. In the facilities that can not afford to perform this complicated and time-consuming procedure, Filix-Widal test is used to facilitate the diagnosis. However, many limitations lead to difficulties in the interpretation of the Widal test. In contrast, the Typhoid IgG/IgM Rapid Test is a simple and rapid laboratory test. The test simultaneously detects and differentiates the IgG and the IgM antibodies to S. typhi specific antigen thus to aid in the determination of current or previous exposure to the S. typhi. PRINCIPLE The Typhoid IgG/IgM Rapid Test is a lateral flow immunochromatographic assay. The test cassette consists of: 1) a pink-purple colored conjugate pad containing recombinant S. typhi H antigen and O antigen conjugated with colloid gold (Typhoid conjugates) and rabbit IgG-gold conjugates, 2) a nitrocellulose membrane strip containing two test region (Test line M and G) and a control region (control line). The test line ‘M’ is pre-coated with monoclonal anti-human IgM for the detection of IgM anti-S. typhi, test line ‘G’ is pre-coated with monoclonal anti-human IgG for the detection of IgG anti-S. typhi , and the C band is pre-coated with goat anti rabbit IgG. When an adequate volume of test specimen is dispensed into the sample well of the cassette, the test specimen migrates by capillary action across the test cassette. Anti-S. typhi IgM if present in the patient specimen will bind to the Typhoid conjugates. The immunocomplex is then captured on the membrane by the pre-coated anti-human IgM antibody at test region ‘M’, forming a pink-purple line at ‘M’ region, indicating a S. typhi IgM positive test result. Anti-S. typhi IgG if present in the patient specimen will bind to the Typhoid conjugates. The immunocomplex is then captured by the pre-coated reagents on the membrane, forming a pink-purple line at test region ‘G’, indicating a S. typhi IgG positive test result. Absence of any pink-purple line at test region (M and G) suggests a negative result. The test contains an internal control (control line) which should exhibit a pink-purple line of the immunocomplex of goat anti rabbit IgG/rabbit IgG-gold conjugate regardless of the color development on any of the test region. Otherwise, the test result is invalid and the specimen must be retested with another device. PRECAUTION 1. This package insert must be read completely before performing the test. Failure to follow the insert gives inaccurate test results. 2. Do not open the sealed pouch, unless ready to conduct the assay. 3. Do not use expired devices. 4. Bring all reagents to room temperature (15°C-30°C) before use. 5. Do not use the components in any other type of test kit as a substitute for the components in this kit. 6. Do not use hemolized blood specimen for testing. Wear protective clothing and disposable gloves while handling the kit reagents and clinical specimens. Wash hands thoroughly after performing the test. 7. Users of this test should follow the US CDC Universal Precautions for prevention of transmission of HIV, HBV and other blood-borne pathogens. 8. Do not smoke, drink, or eat in areas where specimens or kit reagents are being handled. 9. Dispose of all specimens and materials used to perform the test as biohazardous waste. 10. Handle the Negative and Positive Control in the same manner as patient specimens. 11. The testing results should be read within 15 minutes after a specimen is applied to the sample well or sample pad of the device. Read result after 15 minutes may give erroneous results. 12. Do not perform the test in a room with strong air flow, ie. an electric fan or strong air-conditioning. Other Info STORAGE AND STABILITY Typhoid IgG/IgM test card should be stored at 4-40°C. The card may be stored at room temperature but not exceeding 40°C in the original sealed pouch. The shelf life or expiry of the card is printed on Pouch as well as carton label. The test kit should be kept away from direct sunlight, moisture and heat.

Send Message

Still searching for
aution screen?