Jaipur
+918529833535

'assay mixture'

Items tagged with 'assay mixture'

product image
immunoassayReagents

INTENDED USE The Finecare™ cTn I/NT-proBNP Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA System for quantitative determination of cardiac Troponin I (cTn I) and N-terminal prohormone of brain natriuretic peptide (NT-proBNP) in human whole blood, serum or plasma. This test is used as an aid to assist in the diagnosis of myocardial infarction and suspected congestive heart failure. STORAGE AND STABILITY 1. Store the test kit at 4℃~30℃ up to the expiration date printed on package. 2. If removed from refrigerator, allow the test kit for 30 minutes to return to room temperature before testing. 3. Do not remove the Test Cartridge from the pouch until use. The Test Cartridge should be used within 1 hour once opened.

Send Message
product image
Clinical Chemistry

The SAL 9000 Modular System delivers high throughput of chemistry and immunoassay testing by integrating Mindray BS-2000 Chemistry Analyzer and CL-6000i Chemiluminescence Immunoassay Analyzer, and new Sample Processing line SPL 2000. With patented automatic serum analysis design, SAL 9000 not only helps you optimize the management of lab space and manpower, it also offers highly reliable test results. Product Specification Automation Fully Automatic Brand Mindray Model Name/Number SAL 9000 Assays Clinical Chemistry Power Supply 230 V Reaction Cuvette Reusable Cuvette Storage 300000 Samples Features Seamless Integration Usage/Application Lab Wavelength 5000nm Number Of Reagent Positions 4 Weight 130kg Frequency 50 Hertz Power 45 Watt Product Description The SAL 9000 Modular System delivers high throughput of chemistry and immunoassay testing by integrating Mindray BS-2000 Chemistry Analyzer and CL-6000i Chemiluminescence Immunoassay Analyzer, and new Sample Processing line SPL 2000. With patented automatic serum analysis design, SAL 9000 not only helps you optimize the management of lab space and manpower, it also offers highly reliable test results. Features Maximize laboratory efficiency Integration: Optimize your lab’s customized arrangement with better automation system Efficiency: High-throughput chemistry and immunology modules for longer walk-away time Reliability: Ingenious and comprehensive analytic system provides reliable and accurate results Easy operation: Fully automated design,user-friendly operation interface and intelligent software function

Send Message
product image
Clinical Chemistry

The SAL 6000 modular system delivers fast throughput and powerful integration across immunoassay and chemistry systems. Broad assays can be tested with one sample tube, which can maximize operation efficiency and increase lab productivity. Product Description SAL 6000 Modular System delivers fast throughput and seamless integration of CL-2000i Chemiluminescence Immunoassay System and BS-800 Modular System. In conjunction with the SPL 1000 Sample Processing System, this scalable platform not only provides optimized workflow, it also offers satisfactory operator experience. Features · Seamless integration, workflow optimization · Uniform software interface, easy of operation · One tube sampling, flexible to test · Technology and quality heritage · Flexible scalability, on-site upgrading · Comprehensive test menu Product Specification Automation Fully Automatic Brand Mindray Model Name/Number SAL 6000 Assays Clinical Chemistry Power Supply 220 V Usage/Application Hospital Frequency 50 Hz

Send Message
product image
Laboratory Usage

Using best-in-class technology, the Mindray CL-6000i is a chemiluminescence immunoassay analyzer with high throughput, high performance and high reliability. Features Throughput: up to 480 tests per hour Measurement principle: enhanced ALP-AMPPD method Reagent carousel: 36 reagent positions with non-stop refrigerating Sample handling: up to 300 samples can be loaded in one batch, sample loading and offloading continuously by sample racks, fast prioritizing STAT samples Sample volume: 5-110 μL Continuously loading of reagents, substrate, cuvettes, wash buffer and waste bags Zero daily maintenance Product Specification Model Name/Number CL-6000i Usage/Application Hospital Brand Mindray Sample Volume Range 5-110 microlitre Throughput up to 480 tests per hour Measurement Principle enhanced ALP-AMPPD method Reagent Carousel 36 reagent positions with non-stop refrigerating Sample Handling up to 300 samples can be loaded in one batch,sample loading and offloading continuously by sample r

Send Message
product image
Immunology Analyzer

Fully Automated Chemiluminescence Immunoassay Analyzer Introducing iFlash 1200, a chemiluminescence immunoassay analyzer that offers fully automated immunoassay analysis using Magnetic particle-based Direct Chemiluminescence technology. With a high throughput of up to 120 tests per hour and a first result available in just 13 minutes, iFlash 1200 is one of the fastest and most efficient immunoassay analyzers available on the market. The instrument features continuous STAT sample loading capacity with 16 sample positions, continuous reagents loading capacity with 15 reagent positions, and continuous loading of reaction vessels with a capacity of 500 cuvettes. Additionally, iFlash 1200 uses Acridinium Ester Labeled Direct Chemiluminescence for highly accurate and reliable results, and comes with ready-to-use reagents in convenient 2 x 50 tests pack size for simplified testing. Overall, iFlash 1200 is an innovative and versatile immunoassay analyzer that is perfect for laboratories that require high throughput and rapid turnaround times. iFlash 1200 chemiluminescence immunoassay analyzer Key Features: 1.Continuous loading of reagents with convenient pack size of 2 x 50 tests 2.Continous loading of 500 reaction cuvettes for longer walkaway time 3. 4 step magnetic separation for achieving high precision and quality results 4.Non contact vortex mixer-Highly Efficient technology to prevent carryover & cross contamination Additional information General Information Throughput : upto 120 tests/hour Time to First Results :13 minutes Detection Principle Magnetic particle Based Direct Chemiluminescence Chemiluminescence Label :Acridinium Ester Sample System Sample Position :16 sample position Types of Sample tube :Microcup & blood collecting tubes Sample Volume :5~150μL Reagent System Reagent Position :15 reagent positions with onboard refrigeration Reagent Carousel Temp :2-8 °C Reagent Detection :Reagent Level Tracking Reagent Pack : 2 x 50 tests Reagent Carousel Incubation Capacity :48 reaction vessels Incubation Temperature :37°C+-0.3°C Mixing System :Non-Contact Vortex Mixer Operating Conditions Power Supply :100~240V, 50/60HZ Power Consumption :600VA Temperature :10~30°C Weight :120 Kg Reagents iFlash 1200 reagents iFlash 1200 reagents Pack size 2 x 50 Tests 28 days On board reagent stability 28 days Calibration stability Built in Calibrators for all Parameters

Send Message
product image
Clinical Chemistry

Superior Antisera based turbidimetry assays. Homogenized mixture makes antisera ideal for automation. Lesser Initial Absorbance ensures better sensitivity & linearity. Sl No Product Code Product Pack size (ml) 1 IHA101N HbA1C 1×30 2 IHJS HbA1C Standard 1×2/4×0.5 3 ICA101 CRP 1×44 4 TCJS CRP Standard 1×1 5 IRA101 RF 1×30 6 IRJS RF Standard 1×1 7 IMA101 MAU 1×44 8 IMJS MAU Standard 1×1 9 IAA101 ASO 1×44 10 IAJS ASO Standard 1×1 11 ICA102 Us CRP with Standard 1×10/2×25 12 IC3A102 C3 1×5/2×25 13 IC4A102 C4 1×5/2×25 14 IGAA102 IgA 1×5/2×25 15 IGGA102 IgG 1×5/2×25 16 IGMA102 IgM 1×5/2×25 17 IPJS Protein Standard High 1×1 18 ICH101 Immunology Control High 1×1 Information every single reagents has a diffrent price 1 pack single price.

Send Message
product image
Rapid Test

Buy AccuTest Syphilis Rapid Card Test (50 Tests) Online from Accurex. This Syphilis test is a special test kit designed to detect Syphilis (Treponema Pallidum- IgA, IgM, IgG) antibodies in serum/plasma. Syphilis is caused by the bacterium Treponema pallidum. There different types of test like VDRL test, RPR test, FTA-ABS, etc. AccuTest Syphilis Test Kit is easy to use at home and gives you 99% accurate result in just 5 -20 minutes, with sensitivity & specificity of 99.67%. Recombinant syphilis antigen (17KDa, 15KDa, 47KDa) is immobilized in the lest line region of the device. AccuTest Syphilis Rapid Test is a special test kit designed to detect Syphilis (Treponema Pallidum- IgA, IgM, IgG) antibodies in serum/plasma. This kit is easy to use at home and gives you 99% accurate result in just 5 -20 minutes, with sensitivity and specificity of 99.67%. 1. AccuTest Syphilis is a chromatographic immunoassay kit for rapid qualitative detection of Treponemal antibodies (IgA, IgM, IgG) generated against Treponema pallidum Antigens (17KDa, 15KDa, 47KDa) in human serum or plasma with high sensitivity and specificity. 2. Results just in 5-20 minutes 3. Accu Test Syphilis exhibits sensitivity and specificity of 99.67%. Features: Based on Chromatographic Immunoassay assay for detection of Treponema pallidum antigens Sample: Human Serum or Plasma 2-3 drops of Serum/Plasma sample required for testing Fast: 1 step method, result in just 5 to 20 minutes Excellent sensitivity and specificity of 99.67% Store unused kit at 2-30C Pack size: 50 T Recombinant syphilis antigen (17KDa, 15KDa, 47KDa) is immobilized in the lest line region of the device. After the specimen is added to the specimen well in the device, it reacts with syphilis antigen coated particles in the test. The mixture migrates chromatographically along the length of the test strip and interacts with the immobilized syphilis antigen. The double antigen test format can detect IgA, IgG & IgM in specimens. If the specimen contains TP antibodies a coloured band will appear in the lest line region indicating a positive result. In the absence of TP antibodies a coloured band will not appear in the region indicating a negative result. To serve as a procedural control, a coloured band will always appear in the control line region indicating that proper volume of specimen has been added and membrane wicking has occurred. Based on Chromatographic Immunoassay assay for detection of Treponema pallidum antigens Sample: Human Serum or Plasma 2-3 drops of Serum/Plasma sample required for testing Fast: 1 step method, result in just 5 to 20 minutes Excellent sensitivity and specificity of 99.67% Store unused kit at 2-30C Pack size: 50 T Direction for Use Procedure: 1. Bring the pouch to room temperature before opening to avoid condensation of moisture on the membrane of the device. Also bring the specimen to R.T. prior to testing. 2. Label the device with patient’s identification. 3. Add 2-3 drops (approx. 30 pl) of sample into the sample well of the test device. Avoid overflowing. 4. Wait for 5 – 20 minutes and read the result. It is important that the background is clear beforg the result is read. Note: Do not read the result after 30 minutes since specimen back flow may cause false result. STORAGE, STABILITY & HANDLING 1. The kit should be stored at 2 – 30° C. Do not freeze. 2. Do not use the kit past the expiration date stated on label. 3. Take off the device from the sealed pouch just before use as the device is sensitive to humidity and heat.

Send Message
product image
Rapid Test

Buy AccuTest HCV Rapid Card Test (30 Tests) Online from Accurex. HCV means Hepatitis C Virus which is a is a small, enveloped, positive-sense, single-stranded RNA virus. Hepatitis C symptoms are fever, fatigue, decreased appetite, nausea, vomiting, abdominal pain, dark urine, pale feces, joint pain and jaundice. HCV test is a rapid Chromatographic Immunoassay work on principle of the double antigen sandwich technique, Qualitative detection of antibodies generated against proteins that are encoded by conserved sequence of core NS3, NS4, NS5 parts of HCV genome in human whole blood/serum or plasma. AccuTest HCV Test is a rapid Chromatographic Immunoassay for the Qualitative detection of antibodies generated against proteins that are encoded by conserved sequence of core NS3, NS4, NS5 parts of HCV genome in human whole blood/serum or plasma. Hepatitis C Virus (HCV) is a small, enveloped, positive-sense, single-stranded RNA virus. Antibody to HCV is found in over 80% of patients with well documented non-A, non-B hepatitis. Conventional methods fail to isolate the virus in cell culture or visualize it by electron microscope. Cloning the viral genome has made it possible to develop serologic assays that use recombinant antigen, multiple antigens using recombinant protein and/or synthetic peptides have been added in new serologic tests to avoid nonspecific cross-reactivity to increase the sensitivity of HCV antibody tests. Storage and Stability: AccuTest HCV should be stored at 4-30C. However, the card may be stored at room temperature not exceeding 30C in the original sealed pouch. Test Procedure: 1. Allow the test, specimen and or control to room temperature prior to the testing 2. Remove one test card from the pouch and place it on a clean flat surface 3. Using the dropper provided one drop of serum/plasma or W. blood sample (30ul) then two drops of buffer (40ul) immediately into the sample well. Avoid overflowing 4. Read results within 15 minutes. Strong positive reaction may visible within 5 minutes. Do not read results after 15 minutes. 5. If negative or quest Principle: AccuTest HCV Rapid Hepatitis C Virus Test (Serum/Plasma/Whole Blood) is a lateral flow chromatographic immunoassay based on the principle of the double antigen-sandwich technique. The membrane is coated with recombinant HCV antigen on the test line region of the device. During testing, the serum/plasma or W.Blood specimen reacts with HCV antigen coated particles. The mixture migrates upward on the membrane chromatographically by capillary action to react with recombinant HCV antigen or membrane and generate a colored line. Presence of this colored line indicates a positive result, while its absence indicates a negative result. To serve as a procedural control, a colored line will always appear at the control line region, indicating that the correct volume of specimen has been added and membrane wicking has occurred. Storage and Stability: AccuTest HCV should be stored at 4-30C. However, the card may be stored at room temperature not exceeding 30C in the original sealed pouch. Test Procedure: 1. Allow the test, specimen and or control to room temperature prior to the testing 2. Remove one test card from the pouch and place it on a clean flat surface 3. Using the dropper provided one drop of serum/plasma or W. blood sample (30ul) then two drops of buffer (40ul) immediately into the sample well. Avoid overflowing 4. Read results within 15 minutes. Strong positive reaction may visible within 5 minutes. Do not read results after 15 minutes. 5. If negative or questionable results are obtained, the HCV infection is suspected, the test should be repeated ona fresh serum specimen. Safety Information •Positive: If a distinct purple line is formed at the test one marked ‘T’ (Test Line) and the Control Zone marked ‘C’ (Control Line) the test result is positive, indicating the sample contains Hepatitis C antibody. The interpretation of test results (+ve for hepatitis) remains unchanged even if there is a difference in intensity of color in positive line and control line as is many a time found. •Negative: If a distinct purple line is formed only at the control zone marked ‘C’ (control line) the test result is negative • Invalid: A total absence of color in both © and (T) regions or no colored band appears on the control © region is an indication of procedure error and/or the test reagent has deteriorated. Repeat with a new test kit. Direction for Use Test Procedure 1. Allow the test, specimen and or control to room temperature prior to the testing 2. Remove one test card from the pouch and place it on a clean flat surface 3. Using the dropper provided one drop of serum/plasma or W. blood sample (30ul) then two drops of buffer (40ul) immediately into the sample well. Avoid overflowing 4. Read results within 15 minutes. Strong positive reaction may visible within 5 minutes. Do not read results after 15 minutes. 5. If negative or questionable results are obtained, the HCV infection is suspected, the test should be repeated ona fresh serum specimen. Other Info Storage and Stability AccuTest HCV should be stored at 4-30C. However, the card may be stored at room temperature not exceeding 30C in the original sealed pouch.

Send Message
product image
Clinical Chemistry

Infinite Liquid a-Amylase 12 ml Diagnostic Reagent from Accurex (Pack Size : 6 x 2 ml). a-Amylase reagent is used for determination of amylase activity based on kinetic method using Gal G2 – a CNP. Amylase is a ready-to-use reagent. Normal amylase level is 40 to 140 units per liter (U/L) or 0.38 to 1.42 microkat/L (µkat/L). Infinite a-Amylase can be used on any Spectrophotometer, Discrete semiautomated & Automated analyzers. Reaction type is Kinetic. Accurex Biomedical is the first biochemical reagents manufacturing company in India About Infinite a-Amylase ‘is a reagent set for determination of amylase activity based on kinetic method using Gal G2 – a CNP. Infinite a-Amylase is a ready-to-use reagent. Infinite a-Amylase can be determined in just 21/2 minutes at 37°C. Infinite a-Amylase is linear upto 2000 IU/1. Infinite a-Amylase is a High Stability Reagent. Infinite a-Amylase can be used on any Spectrophotometer, Discrete semiautomated and Automated analyzers. Programme can be designed for any specific analyzer upon request. Pack Size : 6 x 2 ml Principle Amylase test involves use of a chromogenic substrate Gal G, – a CNP (2-chloro-4-nitrophenyl linked with galactosyl maltoside). The direct action of amylase with this substrate results in the release of more than 90% of 2-chloro-4-nitrophenol, which can be monitored by kinetic assay at 405 nm. The increase in absorbance is directly proportional to the amylase activity in the sample. Quality Control To ensure adequate quality control, it is recommended that each batch should include a normal and abnormal commercial reference control serum. It should be realized that the use of quality control material checks both instrument and reagent functions together. Factors which might affect the performance of this test include proper instrument function, temperature control, cleanliness of glassware and accuracy of pipetting. Other Details Mix thoroughly and transfer the assay mixture immediately to the thermostated cuvette and start the stopwatch simultaneously. Record the first reading at 60 second and subsequently three more readings with 30 seconds interval at 405 nm.

Send Message

Still searching for
assay mixture?