Jaipur
+918529833535

'actual appearance'

Items tagged with 'actual appearance'

product image
Urinalysis

Product Description: It is a hybrid & walkaway system for automated chemistry & sedimentation/ microscopic analysis of Urine sample Product Features: Fast and accurate classification and quantitative determination of the urine sediment Clear and sharp images of the actual appearance of elements simulating visual microscopy Automatic recognition of elements in sediment based on sophisticated artificial intelligence Accurate evaluation of test strips by color matrix definition technology Product Application: This system is truly walk away analyzer aiding rapid and reliable urine analysis for labs and hospitals with high workload. Strip Analysis: Method - Reflective Photometry , Input Tray Capacity- 200 strips, Parameters- 10 Sediment Analysis: Method- Automated Brightfield Microscopy with Advanced Element recognition, Number of Images- 15 images/sample, Parameters- 16 categories System throughput: Hybrid Mode (Chemistry & Sediment) - 100 samples/h, Sediment Only- 180 samples/h Sample handling: Memory capacity- 500,000 results, Rack Size- 10 tubes, Sample load capacity - 120 samples, Sample Volume- Min 2ml Control System: Display- 23'' Multi-touch screen, OS- Windows 8.1, Printer interface-USB, LIS Interface-Bi-directional Certification: CE certified

Send Message
product image
Hematology

The advanced BC-6800Plus not only provides more reliable routine CBC plus 5-part DIFF results, but also has a higher throughput of up to 200 samples per hour. Based on the new SF Cube technology platform, the BC-6800Plus could provide more reliable blood cell results and abnormal cells flagging results with anticipated warning messages, exceeding clinicians’ expectations and setting a new standard for blood analysis. SF Cube Technology With the newly designed opticals and reagent systems, the SF Cube technology can help doctors to better differentiate the clusters of cells, which is the key to revealing more abnormal cells. NRBC result in every CBC In WNB scattergram, BC-6800Plus provides NRBC, Basophils and WBC-N* results. It means that the actual number of NRBCs can be measured in routine CBC, if they are present in the sample. Basophils are counted in this counting channel with NRBC results. Basophil and NRBC results are generated on BC-6800Plus without extra reagent or cost. NLR parameter in each CBC+DIFF Neutrophil-to-lymphocyte ratio (NLR) is calculated by dividing neutrophil count by lymphocyte count, usually from peripheral blood sample. In laboratory medicine, NLR is used as a marker of subclinical inflammation. According to clinical studies, NLR can be used as a prognostic factor of severe illness in COVID-19 patients. More accurate RET and PLT-O result By utilizing the new fluorescent dye, the reticulocytes and platelets are more specific stained with stronger fluorescent signal, that brings more reliable reticulocyte and platelet results. Automatic Rerun & Reflex Should the sample results trigger the criteria, the sample rack can automatically step back for a “rerun” or “reflex” check. 200 test/hour BC-6800Plus can load up to 100 samples at a time and offers a throughput of up to 200 tests per hour.

Send Message
product image
Laboratory Usage

TACHOMETER/STROBOSCOPE, Model : BP-2259 ( 2 in 1, DIGITAL PHOTO TACHOMETER with DIGITAL STROBOSCOPE ) FEATURES* Intelligent, microprocessor circuit design, high accuracy, wide range, digital readout.* One instrument include two functions of " Digital Photo Tachometer " & " Digital Stroboscope "* Digital Stroboscope :Wide setting range from 100 RPM to 100,000 RPM, digital display with high accuracy. Modern solid state high visible orange light, long life, almost maintenance free. It is ideal for inspectingand measuring the speed of moving gears, fans, centrifuges, pumps, motors and other equipment used in general industrial maintenance, production, quality control, laboratories and as well as for schools and colleges for demonstrating strobe action.* Digital Photo Tachometer :No contact RPM measurement, wide measuring range from 0.5 to 100,000 RPM. 0.1 RPM resolution for the measured value < 1000 RPM. The last value, max., value, min. value can be stored into the memory automatically & be obtained by pressing " Memory Call Button ". High visible LCD display gives RPM reading exactly with no guessing or errors.* The use of durable, long lasting components, including a strong, light weight ABS plastic housing.Cabinet has been carefully shaped to fit comfortable in either hand. GENERAL SPECIFICATIONS Display 5 digits, 10 mm ( 0.4" ) LCD Operation 0 - 50 (32 - 122 ). ( Liquid Crystal display ) with Temperature function annunciation. Operating Less than 80% RH.Accuracy ± ( 0.1 % + 2 digit ). Humidity Sampling Time 1 second ( 60 RPM ). Size 215 x 65 x 38 mm.Time base:Quartz crystal. (8.5 x 2.6 x 1.5 inch). Circuit Exclusive one-chip design Weight 300g(0.66 LB)/including battery.microprocessor LSI circuit. Accessories : Carrying case ................... 1 PC.Battery 4 x 1.5V AA ( UM-3 ) battery. Operation manual ..............1 PC.ELECTRICAL SPECIFICATIONS ( PHOTO TACHOMETER )Measurement Range 5 to 99,999 RPM Resolution 0.1 RPM ( < 1,000 RPM ) 1 RPM ( 1,000 RPM )Photo Tach. detecting distance 50 to 150 mm/2 to 6 inch. * Typical max. 300 mm/12 inch depending upon ambient light.ELECTRICAL SPECIFICATIONS ( STROBOSCOPE )Stroboscopic 100 to 100,000 FPM/RPM Flash tube High efficiency orange LED Flash Rate FPM: flash per minute lamp.RPM : round per minute Flash Duration Approximately 60 to 1,000Flash Adjust 3 ranges : microseconds. Range Range A: 100-1,000 FPM Flash color Orange Range B: 1,000-10,000 FPM Flash Duration Approx. 16% of period time. Range C: 10,000-100,000 FPM Flash Adjust Coarse adjust knob and Resolution 0.1 FPM/RPM. Knob Fine adjust knob.(Less than 1,000 FPM/RPM) Calibration Crystal time base and1 FPM/RPM microprocessor circuit, don't(Over 1,000 FPM/RPM) necessary take any external calibration process. OPERATIONS PROCEDURES ( STROBOSCOPE )Preparation Determine the range switch to " 1000 RPM " ," 10,000 RPM " or" 100,000 RPM " position.Checking When checking speed, care must be taken to insure that the strobe is flashing in Speed unison (one to one) with the object being monitored. A Stroboscope will also stop motion at 2:1, 3:1, 4:1 et., this is normally referred to as harmonies. To be sure of unison, turn the dial until two images appear - this will double the actual speed. Then lower the flashing rate until a single and stationary image appears -this is the actual true speed.Checking For motion analysis, simply locate the actual speed as mentioned above and then Motion turn the dial slowly up or down. This will give a slow motion effect allowing complete inspection.

Send Message
product image
Urinalysis Analyzer

COBIO S50 is Fully Automated Urine Sediment Analyser. COBIO S50 is Automation of the "Gold Standard" manual microscopy! • Throughput - 50 sample/hours • Large (13.3') high-resolution touch-screen for viewing actual images • Each test is processed in 1 cuvette - no carry-over between samples • Just 1.5 mins testing time / sample • High-definition in-built cameras capture "whole view-field" images similar to HPF images of manual microscopy • Latest "deep learning AI" technology identify, classify, label and count each sediment particle - Fully automated sample preparation (sample mixing, centrifuging, preparation of homogenized layer) to minimize manual errors - Large touch-screen helps zoom-in / zoom-out to access and review images and easily access the menu. - Each test is processed in 1 cuvette – no carry-over between samples - Just 1.5 mins testing time / sample

Send Message
product image
Rapid Test

Buy AccuTest HBsAg Rapid Card Test (50 Tests) Online from Accurex. HBsAg means Hepatitis B surface antigen which is a protein on the surface of hepatitis B virus. It can be detected in high levels in serum during acute or chronic hepatitis B virus infection. HBsAg positive indicates that the person is infectious. The hbsag test kit is a one-step immunochromatographic assay based on the antigen capture, or Sandwich principle. HBsAg positive treatment may include Antiviral medications. AccuTest HBsAg Card Test Hepatitis BHepatitis B is a viral infection that attacks the liver and can cause both acute and chronic disease. An estimated 240 million people are chronically infected with hepatitis B (defined as hepatitis B surface antigen positive for at least 6 months). Laboratory diagnosis of hepatitis B infection focuses on the detection of the hepatitis B surface antigen HBsAg. Hepatitis B surface antigen (HBsAg) consists of lipid carbohydrate and protein elements; the protein moiety provides a marker for identification of chronic, infectious BBV infections. Hepatitis B is transmitted sexually or intravenously and has an incubation period of six months. If not diagnosed properly and in time, it can develop into acute or chronic infection, liver cirrhosis and fulminant hepatitis. This test is very useful for screening blood donors, to find out whether they are HBsAg positive before collection of blood. Principle: AccuTest HBsAg is a qualitative test based on immunochromatography sandwich principle. The test card includes a combination of monoclonal anti-body gold conjugate (colloidal gold) and polyclonal solid phase antibodies which selectively binds Hepatitis B surface antigen with high degree of sensitivity. The HBsAg test is a one-step immunochromatographic assay based on the antigen capture, or Sandwich principle. The method uses monoclonal antibodies conjugated to colloidal gold and polyclonal antibodies immobilized on a nitrocellulose strip in a thin line. The test sample is introduced into well and flows laterally through an absorbent pad where it mixes with the signal reagent. If sample contains HBsAg, the colloidal gold-antibody (mouse) conjugate binds to the antigen, forming an antigen-antibody-colloidal gold complex. The complexes then migrate through the nitrocellulose strip by capillary action, which are stopped by an immobilized antibody zone forming a purple band. The formation of the first purple band (T zone) is indicative of hepatitis positive. To serve as a procedural control, an additional line of antibody antimouse IgG has been immobilized on the card. If the test is performed correctly, this will result in the formation of purple and upon contact with the conjugate as a control line. Safety Information AccuTest HBsAg test kit is designed lor detection of Hepalitis B Surface Antigenin the specimen. As with all diagnostic tests, il is recommended to interpret all the results in line wilh clinical manifestations, other lest resulls & clinicians’s view colleclively. If the lest device is showing stagnancy in flow on chromalography, it is most likely due lo problem in the sample. In this case, relest with a fresh sample or diluted sample. Direction for Use Test Procedure: 1. Allow the test, specimen and or control to room temperature prior to the testing 2. Remove one test card from the pouch and place it on a clean flat surface 3. Using the dropper provided one drop of serum/plasma or W. blood sample (25 ul), wait for few seconds till the Whole blood absorbed by sample pad (approx. 30 second), 4. Add 2-3 drops of buffer (60 ul) into the sample well. (If needed add one more drop of assay buffer). 5. Let reaction proceed until the appearance of positive line and control line or up to 20 minutes. 6. Read results after 20 minutes, strong positive reaction may visible within 5 minutes. 7. If negative or questionable results are obtained, the HBV infection is suspected, the test should be repeated ona fresh serum specimen. Storage: AccuTest HBsAg should be stored at 4-30C. However, the card may be stored at room temperature not exceeding 30C in the original sealed pouch.

Send Message
product image
Glucometer

💝High Accuracy & Stability: Upgraded innovative chips are made in the USA, and upgraded algorithm enables accurate results, while high conductivity strips avoid interference. 💝New Exterior Design: Simple and stylish appearance, Eye-catching three buttons on the meter, easy to operate, comfortable to hold. 💝Large Memory Capacity: Memory capacity reaches 200, which is able to record the average results of 7 days, 14 days and 28 days. With easy access to historical data, you can control your blood sugar levels and track any fluctuations. 💝Sinodrew Painless Lancing Device: The device is combined with 9 different depth settings. The concave trigger button is designed to prevent pressing by mistake. It aims to reduce 80% of pain during blood collection, only need 0.6UL of the blood sample. 💝Quick Measurement & Tiny Sample Volume: No coding required, 0.6μL sample volume of the blood glucose result with just 5 seconds. More easily and conveniently use for the elderly. Package Included: 25 Kit (mg/dL or mmol/L) 1 x Lancing Device 1 x Glucometer-mg/dL (No Battery) OR 1 x Glucometer-mmol/L (No Battery) 1 x PU Bag 25 x Bottled Test Strips 25 x Lancets 1 x Manual 50 Kit (mg/dL or mmol/L) 1 x Lancing Device 1 x Glucometer-mg/dL (No Battery) OR 1 x Glucometer-mmol/L (No Battery) 1 x PU Bag 50 x Bottled Test Strips 50 x Lancets 1 x Manual 100 Kit (mg/dL or mmol/L) 1 x Lancing Device 1 x Glucometer-mg/dL (No Battery) OR 1 x Glucometer-mmol/L (No Battery) 1 x PU Bag 100 x Bottled Test Strips 100 x Lancets 1 x Manual 50 test strips 50 x Bottled Test Strips 50 x Lancets 100 test strips 100 x Bottled Test Strips 100 x Lancets

Send Message
product image
Rapid Test

Oscar Chikungunya test is an in vitro diagnostic rapid test based on the principle of immunochromatography on a membrane, for simultaneous and differential detection of Chikungunya specific antibody (IgM/IgG) in human serum/ plasma for diagnosis of Chikungunya infection. For professional use only. Pack Size: 10 Tests Several methods can be used for diagnosis of chikungunya virus infection. Serological tests, such as ELISAs may confirm the presence of IgM and IgG anti-chikungunya antibodies. The virus may also be directly detected in the blood during the first few days of infection by both serological and virological methods (particularly reverse transcriptase–polymerase chain reaction (RT–PCR)). There is no specific antiviral drug treatment for chikungunya. The clinical management targets primarily to relieving the symptoms, including the joint pain using anti-pyretics, optimal analgesics, drinking plenty of fluids and general rest. The joint pain is often very debilitating; it usually lasts for a few days, but may be prolonged for weeks, months or even years--the name “chikungunya” derives from a word in the Kimakonde language, meaning “to become contorted”, and describes the stooped appearance of sufferers with joint pain (arthralgia).

Send Message

Still searching for
actual appearance?