Jaipur
+918529833535

'active calibration curve quality controls'

Items tagged with 'active calibration curve quality controls'

product image
Hemostasis Analyzer

Product Description: It’s a modern and advanced analyzer in Hemostasis. This single channel coagulation analyzer redefines the benefits in its class Erba. ECL 105 can perform PT, APTT, Fibrinogen, Thrombin Time, All Factiors, Lupus and DDimer. Product Features: Clotting Tests such as PT, aPTT, Fibrinogen, Thrombin time, Factors, Lupus anticoagulant performed using Light scatter principle Tests like D Dimer performed using Immuno-turbidimetry principle Interactive touch screen interface Clotting Graph provides details of the clotting testCuvette and reagent management software Twelve levels of QC with Levy-Jennings Plot- Identifies random and systematic errors Temperature stability at 37 degree C to perform the tests. Low Reagent Consumption USB Connectivity CE mark Product Applications: ECL 105 has uses in various routine IVD labs for doing routine PT and aPTT It has application in Blood Banks for Quality Control of Fibrinogen and Factor VIII It is used as Standby to bigger systems, in accredited centres It is used in Research Facilities to perform PT and aPTT on animal samples such as rat, mouse, rabbit, hamsters etc Key Specifications: Single channel semi-automated hemostasis system It can analyze 1 test at a time Sample id can be 14 digits alphanumeric, with progressive id or custom id options It is also possible to have a second position of assay preparation/incubation during the analysis of the current one, using preparation line option Optically detects and automatically moves to the next assay steps and auto starts the measurements Tests principles: Clotting (scattered light at 640nm) Immuno-turbidimetric (turbidimetry at 800nm) Dimensions / Weight: Dimension : 216 x 205 x 75 mm Weight : ~1 kg Environmental requirements: Operating Temperature : 17-32°C Humidity: Max. 80% Relative Humidity, non-condensing Power: Power Supply : 100-240 VAC and 50/60 Hz Power Consumption : 45 Watts In-Rush Power : 150 VA or less Calibrations: Up to 6 calibration levels per assay Storage of the active calibration curve Quality Controls: Up to 12 different control total can be assigned to any given assay Automatic Levey-Jennings plotting Automatic statistics calculation Storage of Quality Control results Stored Results: Independent storage allocation in the instrument memory for Quality Control (QC) and patient determinations Up to 1000 results for QC determinations Up to 1000 results for patients New results automatically replace the oldest results of the appropriate category past the maximum storage allowance Reaction curves are exclusively stored on the external USB pen drive. Regular backup and file purging is recommended from the USB pen drive to insure rapid operations. USB pen drive, FAT32 formatted

Send Message
product image
Hemostasis Analyzer

Product Description: It’s an advanced analyzer for Complete Hemostasis. This four channel coagulation analyzer redefines the benefits in its class. Erba ECL 412, can perform PT, APTT, Fibrinogen, Thrombin Time , All Factors, Lupus , Protein S, Protein C , Antithrombin III and DDimer. Product Features: Clotting Tests such as PT, aPTT, Fibrinogen, Thrombin time, Factors, Lupus anticoagulant, Protein S performed using Light scatter principle. Protein C, Antithrombin III done by Chromogenic Principle Tests like D Dimer performed using Immuno-turbidimetry principle Interactive touch screen interface Clotting Graph provides details of the clotting test Cuvette and reagent management software Twelve levels of QC with Levy-Jennings Plot- Identifies random and systematic errors Temperature stability at 37 degree C to perform the tests Low Reagent Consumption USB Connectivity CE mark Product Applications: ECL 412 has uses in various routine IVD labs for doing routine PT and aPTT It has application in Blood Banks for Quality Control of Fibrinogen and Factor VIII It is used as Standby to bigger systems, in accredited centers It is used in Research Facilities to perform PT and aPTT on animal samples such as rat, mouse, rabbit, hamsters etc General Specifications: 4 channel semi-automated hemostasis instrument It can perform 4 simultaneous tests of the same parameter Sample id can be 14 digits alphanumeric, with progressive id or custom id options It is also possible to have a second row of assay preparation/incubation during the analysis of the current line, using preparation line option It can run assays in single or duplicate (programmable per assay) Optically detects and automatically moves to the next assay steps and auto starts the measurements Tests principles: Clotting (scattered light at 640nm) Chromogenic (colorimetry at 405nm) Immuno-turbidimetric (turbidimetry at 800nm) Dimensions / Weight: Dimension : 300 x 290 x 90 mm Weight : 3 kgs Environmental requirements: Operating Temperature : 17-32°C Humidity: Max. 80% Relative Humidity, non-condensing Power: Power Supply: 100-240 VAC and 50/60 Hz Power Consumption: 45 Watts In-Rush Power: 150VA or less Calibrations: Up to 6 calibration levels per assay Storage of the active calibration curve Quality Controls: Up to 12 different control names total can be assigned to any given assay Automatic Levey-Jennings plotting Automatic statistics calculation Storage of Quality Control results Stored results: Independent storage allocation in the instrument memory for Quality Control (QC) and patient determinations Up to 600 results for QC determinations (run in duplicate) Up to 900 results for patients (run in duplicate) New results automatically replace the oldest results of the appropriate category past the maximum storage allowance Reaction curves are exclusively stored on the external USB pendrive. Regular backup and file purging is recommended from the USB pendrive to insure rapid operations. (We recommend at least a monthly purge from a computer to back up and remove CH files) USB pendrive , FAT32 formatted

Send Message
product image
Laboratory Testing Reagents

Product Description We are the Leading Supplier of Calibration Solution for pH TDS COND. The team of our skilled professionals is actively involved in providing a comprehensive array of Calibration Solution Salinity Cap. Our product is acclaimed in the industry owing to its purity & high effectiveness. This solution is processed under the direction of skilled professionals utilizing the optimum grade chemicals as per the set industry norms. Provided product is ideal for quickly performing the routine calibration required to maintain the robust performance of thermo scientific mass spectrometers. Features: Precise composition Longer shelf life Optimum quality Other Details: Calibration Solution for Salinity Cap - 480 ml, Range - 5 ppt, 25 ppt, 45 ppt CON603K Conductivity 0 to 200 m S/cm - Battery IP 54 Product Specification Usage Industrial Packaging Size 480 ml Grade Standard Reagent Grade Packaging Type Bottle Range 5 ppt, 25 ppt, 45 ppt Color Transparent Liquid

Send Message
product image
Clinical Chemistry

ADVIA 2400 Chemistry System The right balance of speed and efficiency The ADVIA® 2400 Clinical Chemistry System manages the most demanding workloads and meets high turnaround-time (TAT) goals. Its menu includes methods for testing drugs-of-abuse, therapeutic drugs (TDM) and new assays such as cystatin C and CardioPhase® hsCRP. The ADVIA 2400 Clinical Chemistry System offers: High throughput of up to 2400 tests/hour (1800 photometric and 600 ISE) to manage heavy workloads Rapid, consistent, 2-second cycle time for faster tube speed and test throughput User-defined automatic repeat, dilution, and reflex testing Large onboard reagent capacity and optional concentrated reagents help to minimize intervention demands Refrigerated onboard storage of controls and reagents for extended stability and increased productivity Automation-ready design: no additional hardware required Features & Benefits The ADVIA 2400 Clinical Chemistry System meets today’s high turnaround-time goals with a throughput of up to 2400 tests/hour. In addition to assays for general and specialty chemistries, its menu includes assays for specific protein measurement, drugs-of-abuse testing (DAT), and therapeutic drug monitoring (TDM). Interesting new assays such as cystatin C, HbA1c with automated sample pretreatment, and CardioPhase® hsCRP can now be included in your routine testing. The ADVIA 2400 Chemistry System pushes productivity levels while maintaining the reliability and stability that keep laboratories up and running. A rapid, 2-second probe cycle time maximizes tube speed and test throughput and combines with the system’s efficient automation-readiness to provide the turnaround time needed for high-volume laboratories Superior Speed and Productivity Throughput of up to 2400 tests/hour (1800 photometric and 600 ISE) to manage the heaviest workloads Rapid, consistent, 2-second cycle time Throughput of 200 tubes per hour, even when running three ISE tests and nine photometric tests per sample Automatic Sample Retain technology, auto-repeat, auto-dilution, and auto-reflex testing Automation-ready Point-in-space aspiration enables connectivity to a track. Redundant sample loading provides built-in backup and easy handling of non-routine samples. Direct sampling from track prevents tubes being detained at an analyzer and reduces aliquoting. Minimal Need for Operator Intervention Minimal-maintenance ISEs Large onboard reagent capacity and optional concentrated reagents for fewer interruptions No-maintenance, 37°C incubation oil bath Auto-calibration and auto-QC from refrigerated onboard calibrators and controls Microvolume technology with 32,000 tests onboard and up to 60 days' onboard stability for improved walkaway time. Concentrated reagents for increased maximum capacity. Remote diagnostics and Inter-Laboratory Quality Control (ILQC) options Exceptional Reliability Sample integrity check for icterus, hemolysis, and lipemia Sample probe with automatic clot/clog detection, liquid-level sensing, short-sample detection, and crash protection Advances in onboard reagent stability, calibration frequency, reduction in interferences, and expanded assay linearity

Send Message
product image
Clinical Chemistry

The ADVIA® 1800 Clinical Chemistry System pushes the limit of productivity. Its extensive menu allows integration of testing for clinical chemistry, drugs-of-abuse, therapeutic drug monitoring (TDM) and specific proteins such as cystatin C and CardioPhase® hsCRP. The ADVIA 1800 Clinical Chemistry System offers: Throughput of up to 1,800 tests per hour to keep pace with workload peaks 200 basic metabolic panels per hour to meet turnaround-time demands Large onboard reagent capacity and optional concentrated reagents to reduce interruptions Optimal standardization of reagents and systems for efficient consumable usage Refrigerated onboard storage of controls and reagents for extended stability and increased productivity Automation-ready design: no additional hardware required Features & Benefits The ADVIA 1800® Clinical Chemistry System pushes the limit of productivity in the core lab and meets the turnaround-time (TAT) goals of today’s laboratories. Its extensive menu allows integration of general clinical chemistry testing with testing for drugs-of-abuse, TDM, special chemistry, and specific proteins such as cystatin C and CardioPhase® hsCRP. Automation-ready design Point-in-space aspiration enables connectivity to a track, VersaCell® System. Redundant sample loading provides built-in backup and easy handling of non-routine samples. Direct sampling from track prevents tubes being detained at an analyzer and reduces aliquoting. Peak productivity Throughput of up to 1,800 tests per hour provides the speed to keep pace with workload peaks. Throughput of 200 basic metabolic panels per hour helps to meet turnaround-time demands. Automatic Sample Retain technology lets you perform reruns and dilutions without the need to retrieve primary tubes. Consolidate chemistry testing on one system with a comprehensive menu, consistent cycle times, speed, and open application capability. Total system reliability Minimal-maintenance ISEs Robust hardware and simplified software design, with automatic calibration validation and tracking Advances in reagent onboard stability, calibration frequency, interference reduction and assay linearity expansion Direct water connection Remote diagnostics and Inter-Laboratory Quality Control (ILQC) options Easy efficiency Large onboard reagent capacity and optional concentrated reagents reduce interruptions. High-resolution touchscreen delivers push-button operation. Reagent pause capability and onboard Sample Pause button make loading easy. Minimal maintenance requirements, including no-maintenance oil bath, reduce hands-on time. Sample integrity checking, include serum indices reporting, short-sample flagging, and clot detection, reducing the need for manual intervention.

Send Message
product image
Laboratory Testing Reagents

We are noticed amongst the well-known manufacturer and supplier in this domain, involved in providing Calibration Solution. This product is processed & formulated by our professionals utilizing superior grade chemicals in line with international quality norms. The offered product is obtainable in different grades with airtight packing in bottles as per the requirements of the clients. This product is tested at labs on numerous predefined standards of the industry before its final dispatch to the customers. Features: Safe usage Superior quality Easy to store Other Details: Calibration Solution Hamilton USA Make Ph / TDS / Cond / ORP / Redox in a Bottle of 500 ml NIST Traceable Certificate & 5 Year Shelf Life Product Details: Packaging Type Bottles Brand Hamilton Packaging Size 500 ml Color White Transparent Shelf Life 5 Years Certificate NIST Traceable

Send Message
product image
Instruments

We are the Leading Supplier of ORP Meter Calibration Solution. Our firm has gained huge recognition for providing a qualitative assortment of ORP Meter Calibration Solution that used much like pH values to determine water quality. Offered product is processed utilizing supreme class chemicals and leading techniques in adherence to the set norms of the industry. This product is well tested on diverse aspects so as to supply a pure range to customers. We offer this product in various grades to choose from. Our product is acknowledged among customers for its optimum quality. Features: Accurate formulation Highly effective Optimum quality Other Details: Calibration Solution for ORP Meter Cap - 480 ml Range - 475 mV, 263 mV, 86 mV With Eutech Certificate of Analysis ORP electrode ECFC7960201 B plastic body double junction gel filled Product Details: Usage Industrial Packaging Size 480 ml Grade Standard Technical Grade Packaging Type Bottle Range 475 mV, 263 mV, 86 mV Color White Transparent

Send Message
product image
Laboratory Usage

POLAX-2L Polarimeter by Atago U.S.A. Polarimeter, which is known as an optical rotation meter, is an instrument to measure optical rotation of "optically active matter" such as saccharin, ascorbic acid and sodium glutamate. Product Specification Model POLAX-2L Material PVC Color White Indicator Digital ATC 18-30 deg C Meter Manually Operating Product Description We are offering Polarimeter Manual to our clients. We provide high-quality products to our clients. Other Details: Model POLAX-2L manually operating meter with digital indicator with ATC 18-30ºC

Send Message
product image
Glucometer

Accu-Chek® Active blood glucose meter Personalised Diabetes Coaching Accurate, no coding, easy Item Description The Accu-Chek Active blood glucose meter packs many powerful features into a smaller size. No coding reduces handling steps, see test result averages up to 90 days, get alerts if your test strips are expired or if you’ve underdosed, re-dose within 10 seconds, set pre-and post-meal reminders to test, and more. Benefits and Features accurate: Accurate1 blood glucose measurement easy: No coding for even easier blood glucose monitoring easy-to-read display (new typeface) intuitive handling with just 2 buttons safe: Underdose detection visual double check 10 seconds re-dose option clever: Pre- and postmeal markers postprandial reminder 7,14,30 or now 90 day test averages USB interface for data transfer Remark: Previous Accu-Chek Active meter generations will be upgraded to no coding via black activation chip . Know more>> 1The Accu-Chek Active bGM system meets the DIN EN ISO 15197:2013 requirements (data on file, 2014). Additional specifications Meter type : Accu-Chek Active meter (Model GB) Catalogue no. / Serial no. : See type plate on the back of the meter Test principle : Determination of glucose in fresh capillary blood by reflectance photometry. Blood glucose values can be tested in whole blood or plasma. The meter displays blood glucose values corresponding to those in plasma. Measuring interval : 10-600 mg/dL Blood volume : 1-2 μl Measuring time : Test strip in the meter: approx. 5 seconds Test strip outside the meter: approx. 08 seconds Power supply : 1 battery (type CR2032) Battery life : approx. 1000 tests or approx. 1 year Automatic power-off : after 30 or 90 seconds depending on operating status Memory : 500 test results with time and date, as well as 7, 14, 30 and 90 days averages Temperature : During testing: +8 to +42°C During storage without battery: -25 to +70°C During storage with battery: -20 to +50°C Atmospheric humidity : During testing: up to 85% relative humidity During testing: up to 93% relative humidity Altitude: Sea level to 4000 m Dimensions : 97.8 x 46.8 x 19.1 mm Weight : Without battery: approx. 46 g With battery: approx. 50 g Display : 96-segment liquid crystal display (LCD) Interface : USB (Micro B) Safety class : III Electromagnetic compatibility : The Accu-Chek Active meter meets the electromagnetic immunity requirements and the electromagnetic emissions requirements as per EN 61326-2-6 and EN ISO 15197 Annex A. The chosen basis for electrostatic discharge immunity testing was basic standard IEC 61000-4-2. Performance analysis : Calibration and traceability: The performance data for the Accu-Chek Active bGM system was calibrated using venous blood containing various glucose concentrations. Reference values are obtained using the hexokinase method, which is calibrated using the ID-GCMS method. Accuracy performance : The Accu-Chek Active bGM system meets the DIN EN ISO 15197:2013 requirements (data on file, 2014). How to use Accu-Chek Active blood glucose meter Testing your blood glucose is an essential part of managing diabetes. The Accu-Chek Active blood glucose meter can help to make it convenient by giving you fast, hassle-free, and accurate results in 4 simple steps. Insert the glucose test strip Prick your finger with the lancet to draw out a blood drop. Carefully touch the blood drop onto the green field of the test strip. Read the blood glucose result.

Send Message

Still searching for
active calibration curve quality controls?