Jaipur
+918529833535

'accurate evaluation'

Items tagged with 'accurate evaluation'

product image
Rapid Test

Intended Use The HIV TRI-DOT test is a visual, rapid, sensitive and accurate immunoassay for the differential detection of HIV-1 & HIV-2 antibodies (IgG,IgM & IgA) in human serum or plasma using HIV-1 & HIV-2 Antigens immobilized on an immunofiltration membrane. The test is a screening test for Anti HIV-1 and HIV-2 and is for in vitro diagnostic use only. Salient Features Rapid visual test ,based on Flow Through Technology. Differential detection of HIV-1 & HIV-2. Detection of group ‘O’ & subtype ‘C’. Use of envelop antigens gp41& C terminus of gp120 for HIV-1 & gp36 for HIV-2. 100% sensitivity & 100% specificity as per WHO Evaluation. Shelf life 24 months at 2-8°C Available in convenient pack sizes- 50 Tests and 100 Tests. Results within 3 minutes. No instrument required. In built quality control dot.

Send Message
product image
Medical Equipment

Since the company was founded, Mindray has been continuously exploring new ways to improve diagnostic confidence. Powered by the most revolutionary ZONE Sonography® Technology, Resona 7’s new ZST+ platform brings ultrasound image quality to a higher level by zone acquisition and channel data processing. As well as the premium level image quality, Resona 7 also enhances clinical research capabilities with the revolutionary V Flow for vascular hemodynamic evaluation, and the most intelligent plane acquisition from 3D datasets for fetal CNS diagnosis. Combining the most intuitive gesture-based multi-touch operation and all the essential clinical features, Resona 7 is truly leading new waves in ultrasound innovation. With core platform advantages of ZST+ The channel data based ZST+ is an extraordinary innovation, representing an ultrasound evolution. Transforming ultrasound metrics from conventional beamforming to channel data based processing, ZST+ is able to deliver multiple imaging advances: Advanced Acoustic Acquisition, Dynamic Pixel Focusing, Sound Speed Compensation, Enhanced Channel Data Processing and Total Recall Imaging. Advanced features V Flow V Flow (Vector Flow) is a novel approach for vascular hemodynamic analysis. V Flow uses color coded vector arrows to indicate the velocity’s magnitude and direction of blood cells. With ultra-high frame rates, it provides extremely accurate and angle-independent visualization of complex vascular hemodynamic profiles. With comprehensive data information, V Flow is the most valuable tool for vascular clinical research. resona-7-fig3-1-pc UWN+ Contrast Imaging UWN+ (Ultra-Wideband Non-linear Plus) CEUS enables the Resona 7 to detect and utilize both the 2nd harmonic and non-linear fundamental signals, generating significantly enhanced images, resulting in greater sensitivity of minor signals and longer agent duration with lower MI. Forwarding smart to clinical intelligence The Resona 7 elevates clinical intelligence with a complete solution that enables clinicians to manage both routine and advanced studies more efficiently,consistently, and accurately, from acquisition to calculation. As an example, Smart Planes CNS shows exceptional intelligence in accurate diagnosis and analysis of the fetal central nervous system (CNS) Smart Planes CNS Mindray’s exclusive pioneering technology positions the Resona 7 as the industry’s first ultrasound system to allow fully automatic and accurate detection of the most significant planes and frequently used measurements of fetal CNS, leading to intelligent diagnosis, improved throughput, and reduced user dependence. Smart Planes CNS provides a user-friendly tool that greatly improves scanning efficiency through increased accuracy coupled with automated operation. With a simple button click on a 3D fetal brain volume image, the standard CNS scanning planes (MSP, TCP, TTP and TVP) and a range of related anatomical measurements (BPD, HC, OFD, TCD, CM and LVW) are obtained immediately. Smart Face Acquiring an optimal view of the fetal face in 3D ultrasound is cumbersome and time-consuming. In some cases, it is impossible to get rid of the occlusions such as cord, placenta, uterus and extremities. The new Resona 7 with Zone Intelligence provides a fast and intelligent optimization for fetal face with simply one-touch. It can immediately remove occlusions in the volume data, eliminate unwanted noise information, and generate an optimal view of the fetal face with minimal effort. Ergonomics The Resona 7 is designed around you. Gesture-based operation opens up a new trend in cart-based ultrasound with an agile, smart, and intuitive user experience beyond your expectations. Gel warmer’s three level temperature and swiveling angle adjustment of the control panel delivers great patient comfort and user convenience.

Send Message
product image
Urinalysis

Product Description: It is a hybrid & walkaway system for automated chemistry & sedimentation/ microscopic analysis of Urine sample Product Features: Fast and accurate classification and quantitative determination of the urine sediment Clear and sharp images of the actual appearance of elements simulating visual microscopy Automatic recognition of elements in sediment based on sophisticated artificial intelligence Accurate evaluation of test strips by color matrix definition technology Product Application: This system is truly walk away analyzer aiding rapid and reliable urine analysis for labs and hospitals with high workload. Strip Analysis: Method - Reflective Photometry , Input Tray Capacity- 200 strips, Parameters- 10 Sediment Analysis: Method- Automated Brightfield Microscopy with Advanced Element recognition, Number of Images- 15 images/sample, Parameters- 16 categories System throughput: Hybrid Mode (Chemistry & Sediment) - 100 samples/h, Sediment Only- 180 samples/h Sample handling: Memory capacity- 500,000 results, Rack Size- 10 tubes, Sample load capacity - 120 samples, Sample Volume- Min 2ml Control System: Display- 23'' Multi-touch screen, OS- Windows 8.1, Printer interface-USB, LIS Interface-Bi-directional Certification: CE certified

Send Message
product image
HEMOGLOBIN METER

Mispa HbX Portable Haemoglobin Analyzer Overview Mispa HbX , Smart Haemoglobin analyzer is a symbol of advanced point of care equipment with modern technology and convenience, designed to deliver high accuracy, quality results with least turnaround time and low maintenance. Best in Class Hemoglobin Meter Mispa HbX, the Smart Haemoglobin Analyzer, is the best example of an advanced point-of-care hemoglobin reader with modern technology. It is easy to use and designed to deliver accurate, high-quality results with the shortest turnaround time and minimal maintenance. This digital Hb meter is one of the best hemoglobin meters available. Working of A Hemoglobin Meter or a hemoglobin reader A hemoglobin meter or a hemoglobin reader measures the amounts of hemoglobin and hematocrit in whole blood. Hemoglobin tests are typically performed to determine the RBC count, the severity of anemia, hematocrit, and other haematological factors. It is widely utilized during blood donations and key decisions such as blood transfusions. HbX works with Spectrophotometry Scattered compensation Technology for accurate and quick results Results will be retrieved with in less than 3 seconds after sample reading starts Sample Required: 7ul Capillary or Venous blood Three Step procedure makes HbX more convenient to use CV value will be less than 1.5 % 6 Hours Battery Backup makes it a hand equipment 2000 Data storage capacity Micro Fluidic cuvettes with 2 year Shelf life

Send Message
product image
Biochemistry Analyzer

Overview A fully automated POC Auto Dry Biochemistry Analyzer called Mispa Chem Dx, With Just 3 to 4 drops (100ul) of whole blood to test up to 19 General and Special chemistry tests in less than 12 minutes. Mispa Chem Dx works on absorption spectroscopy where a change in absorbance is detected by an absorption spectrum and an algorithm is used to calculate the end concentration of the sample in the reagent dry disc. The reagent disc consists of lyophilized reagent beads, diluent, and calibration details in the QR code. The reagent disc contains an intelligent internal quality control system IQC which continuously monitors the disc function to ensure reaction stability and optimal disc performance, IQC is the engine that drives the Mispa Chem Dx accurately and precisely Low Sample Consumption Easy to Use Maintenance Free Accurate Result Disposable reagent disc Sample volume: 100µl Testing time: 12 minutes / sample Temperature: 37°C ± 0.3°C Resolution: 0.001Abs Absorbance: 0-3.0Abs Sample type: Heparinized whole blood, serum, plasma (heparin) QC&Calibration: IQC (Intelligent Quality Control/Calibration) Work condition: Temperature:10-30°C Humidity: 30%-70% Testing method: End point, kinetic, fixed time, turbidmetry etc Light source: 12V/20W, Halogen tungsten lamp with life span over 2500 hours Power supply: AC 100V-240V, 50-60Hz Display: Android 7.0 inch 800*480, multi-point capacitive touch screen Storage: 500,000 results Printer: Built-in thermal printer Interface: 4 USB ports, 1 LAN port Dimension: 315*375*475mm. 4.2kg(N.W.), 7kg(G.W.)

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ AFP Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA System for quantitative determination of Alpha-Fetoprotein in human whole blood, serum or plasma. The test is used as an aid for early auxiliary diagnosis and the evaluation of therapeutic efficiency for primary hepatic carcinoma. STORAGE AND STABILITY 1. Store the test kit at 4℃~30℃ up to the expiration date printed on package. 2. If removed from refrigerator, allow the test kit for 30 minutes to return to room temperature before testing. 3. Do not remove the Test Cartridge from the pouch until use. The Test Cartridge should be used within 1 hour once opened.

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ CEA Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA System for quantitative determination of carcino-embryonic antigen in human whole blood, serum or plasma. The test is used as an aid in the evaluation of therapeutic efficiency, prognosis and recurrence monitoring for carcinoma. STORAGE AND STABILITY 1. Store the test kit at 4℃~30℃ up to the expiration date printed on package. 2. If removed from refrigerator, allow the test kit for 30 minutes to return to room temperature before testing. 3. Do not remove the Test Cartridge from the pouch until use. The Test Cartridge should be used within 1 hour once opened.

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ Prolactin Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA Meters for quantitative measurement of Prolactin (PRL) in human whole blood, serum or plasma. The test is used as an aid to the evaluation of pituitary endocrine function. STORAGE AND STABILITY 1. Store the test kit at 4~30℃ up to the expiration date. 2. If removed from refrigerator, allow the test for 30 minutes to return to room temperature before testing. 3. Do not remove the cassette from the pouch until ready to use. The test cassette should be used within 1 hour once opened.

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ Estradiol (E2) Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA Meters is for quantitative measurement of Estradiol (E2) in human whole blood, serum or plasma. The test is used as an aid to the evaluation of ovarian diseases. STORAGE AND STABILITY 1. Store the test kit at 4~30℃ up to the expiration date. 2. If removed from refrigerator, allow the test for 30 minutes to return to room temperature before testing. 3. Do not remove the cassette from the pouch until ready to use. The Test cassette should be used within 1 hour once opened.

Send Message

Still searching for
accurate evaluation?