Jaipur
+918529833535

'70 baume light liquid hydrometers'

Items tagged with '70 baume light liquid hydrometers'

product image
BP Apparatus

Product Details: Material Plastic Automation Type Semi-Automatic Color White Usage/Application Industrial Range 0/20 A 0/20 20/40 40/60 60/80 80/100 Type Hydrometers We are engaged in manufacturing and supplying of Sikes Hydrometers of superior quality range. Hydrometers is a device to measure relative density of liquids such as Grease, oil etc. Components used in a hydrometer are glass frame, cylindrical stem and bulb floating in the mercury fluid.To test the density of a liquid, we use a long glass jar.The jar is filled with liquid and hydrometer is floated inside the fluid.The liquid surface touches the stem of hydrometer at specific point, which indicates specific gravity of that fluid. Features: Alcohol meter (V / V, Volume By Volume) Zeal U.K. at 15.6ºC Range: 0-20, 20-40, 40-60, 60-80, & 80-100 JAWA (Brix) Hydrometers with work Certificate Germany Range: No.1 - 2 to 13 No.2 - 13 to 21 No.3 - 19 to 27 Heavy Liquid Hydrometers, Germany Sp.Gr.1000/2000 & BE 0/70 Light Liquid Hydrometers, Germany Sp.Gr. 700/1000 & BE 10/70 Heavy Liquid Hydrometers, 305 mm Long, Range - 1.000 / 2.000 & 0/70 Baume Light Liquid Hydrometers, 230 mm Long, Range : 700 / 1.000 Baume Hydrometers, Germany at 20ºC Range: 0/10, 10/20, 20/30, 0/20, 0/30, 0/40, 0/50, 30/40 & 40/50 Baume Hydrometers, Digital, Atago, Japan Model PAL-84S, Range : 0.0 - 210 Twaddle Hydrometers German at 60ºF, No. 1, 2, 3, 4, 5, & 6 Twaddle Hydrometer Zeal England at 84ºF, No. 1, 2, 3 & 6 Twaddle Hydrometer Zeal England at 84ºF, No. 4 & 5 Brix Hydrometer w/o Thermometer Germany at 20ºC Range: 0/10, 10/20 & 20/30 Brix Hydrometer w/o Thermometer Germany at 27.5ºC Range: 0/10, 10/20, 20/30, 30/40, 0/30, 30/60 & 60/90 Brix Hydrometer with Thermometer Germany at 27.5ºC & 20ºC Range: 0/10, 10/20, 20/30, 0/30, 30/60 & 60/90 Brix Hydrometer with Thermometer Germany GDR, German at 27.5ºC & 20ºC Range: 0/10, 10/20 & 20/30 Brix Hydrometer with Thermometer German with NPL Certificate Brix Hydrometer, Sugar Percent Temp. 27.5ºC Made in West Germany Specific Gravity Hydrometers, Germany at 20ºC 600/700, 700/800, 800/900 & 900/1000 & 800/10001000/1100, 1100/1200, 1200/1300, 1300/14001400/1500, 1500/1600, 1600/1700, 1700/18001000/1200, 1200/1400, 1400/1600, 1600/1800, 1800/2000 800/1000 GDR German Make Sikes Table Book Indian Soil Hydrometer, Zeal England, ASTM 152 H Range: 5 to 60 gm / ltr, Temp: 68ºF Yes! I am interested

Send Message
product image
Distance Meter Digital

Product Details: Warranty 6 Months Material Glass Temperature 15.6oC equal to 60oF Standard ASTM We are the Leading supplying of Hydrometer Device of superior quality range. Hydrometers is a device to measure relative density of liquids such as Grease, oil etc. Components used in a hydrometer are glass frame, cylindrical stem and bulb floating in the mercury fluid. To test the density of a liquid, we use a long glass jar. The jar is filled with liquid and hydrometer is floated inside the fluid. The liquid surface touches the stem of hydrometer at specific point, which indicates specific gravity of that fluid. Specifications: Sikes Hydrometer at 51ºF, Zeal England: Range: 0/20 A 0/20 20/40 40/60 60/80 80/100 Alcohol meter (V / V, Volume By Volume) Zeal U.K. at 15.6ºC Range: 0-20, 20-40, 40-60, 60-80, & 80-100 JAWA (Brix) Hydrometers with work Certificate Germany Range: No.1 - 2 to 13 No.2 - 13 to 21 No.3 - 19 to 27 Heavy Liquid Hydrometers, Germany Sp.Gr.1000/2000 & BE 0/70 Light Liquid Hydrometers, Germany Sp.Gr. 700/1000 & BE 10/70 Heavy Liquid Hydrometers, 305 mm Long, Range - 1.000 / 2.000 & 0/70 Baume Light Liquid Hydrometers, 230 mm Long, Range : 700 / 1.000 Baume Hydrometers, Germany at 20ºC Range: 0/10, 10/20, 20/30, 0/20, 0/30, 0/40, 0/50, 30/40 & 40/50 Baume Hydrometers, Digital, Atago, Japan Model PAL-84S, Range : 0.0 - 210 Twaddle Hydrometers German at 60ºF, No. 1, 2, 3, 4, 5, & 6 Twaddle Hydrometer Zeal England at 84ºF, No. 1, 2, 3 & 6 Twaddle Hydrometer Zeal England at 84ºF, No. 4 & 5 Brix Hydrometer w/o Thermometer Germany at 20ºC Range: 0/10, 10/20 & 20/30 Brix Hydrometer w/o Thermometer Germany at 27.5ºC Range: 0/10, 10/20, 20/30, 30/40, 0/30, 30/60 & 60/90 Brix Hydrometer with Thermometer Germany at 27.5ºC & 20ºC Range: 0/10, 10/20, 20/30, 0/30, 30/60 & 60/90 Brix Hydrometer with Thermometer Germany GDR, German at 27.5ºC & 20ºC Range: 0/10, 10/20 & 20/30 Brix Hydrometer with Thermometer German with NPL Certificate Brix Hydrometer, Sugar Percent Temp. 27.5ºC Made in West Germany Specific Gravity Hydrometers, Germany at 20ºC 600/700, 700/800, 800/900 & 900/1000 & 800/10001000/1100, 1100/1200, 1200/1300, 1300/14001400/1500, 1500/1600, 1600/1700, 1700/18001000/1200, 1200/1400, 1400/1600, 1600/1800, 1800/2000 800/1000 GDR German Make Sikes Table Book Indian Soil Hydrometer, Zeal England, ASTM 152 H Range: 5 to 60 gm / ltr, Temp: 68ºF

Send Message
product image
Clinical Chemistry

With cutting-edge LED technology, the HyLED 7 Series offers excellent luminous efficiency, heat-free light source, and incredible long service life, giving you total support in OR. Usage/Application Operation Theater Positioning Ceiling Mounted Model Name/Number HyLED 7 Series Brand Mindray Light Source Type LED Central illuminance at 1m distance 160,000 lux Light field diameter(at 1m distance) 180~300 mm Depth of illumination(L1+L2) 1,200 mm Correlated color temperature 4,350 K Color rendering index(Ra) 96 Color rendering index(R9) 97 Shadow dilution with tube 100% Shadow dilution with one mask 75% Shadow dilution with tube and one mask 70% Shadow dilution with two masks 55% Shadow dilution with tube and two masks 50% Ambient illumination 8,000 lux Bulb power consumption 85 W Power supply 100~240 VAC, 50/60 Hz Number of LED bulbs 32 Light head dimension 600 mm Integrated Camera Optional Carrier-arm Camera Optional HyLED 7 Series Contact Us With cutting-edge LED technology, the HyLED 7 Series offers excellent luminous efficiency, heat-free light source, and incredible long service life, giving you total support in OR. Efficient & Economic • Incredible long service time up to 60,000 hours • Central Illumination: 160,000 lux/130,000 lux • Adjustable light field diameter • Max. depth of Illumination : 1,200 mm • Low power consumption Original & Unique • Perfectly integrated into laminar flow (Certified per DIN-1946 Part 4) • Touch screen panel for easier control • 330° rotatable integrated HD/FHD camera • Ultra-thin design & excellent maneuverability • Ergonomic and compact design less than 12kg Ergonomic and Compact Design • The ultra-thin concentrically circular design for better hygiene. • DIN-1946 Part 4 certificated. (12-2008) Flexible Design • Combined with an Ondal spring arm maximizes mobility and ensures stability. • Ultra-thin light head with only less than 12 Kg. • Smooth, metal back cover of the light head. High Performance • With a minimum lifetime of 60,000 hours, each latest generation LED illuminates far longer than traditional light sources. • Easier and less costly maintenance: each LED bulb with individual circuit can be replaced respectively, which will minimize the maintenance cost. Easy and Intuitive Control • Traditional control panel • Touch screen panel(optional) Shadow-free The HyLED 7 Series surgical light inherits the advanced technology from the HyLED 9 series and shows excellent shadow management function. The professional shadow dilution experiment simulated extreme situations by using tubes and masks proved that Mindray HyLED 7 Series surgical light has sufficient illumination even in extreme situations. Camera System for Communication The camera system provides better communication and documenting solutions. The camera system integrated with the surgical lights also provides a platform for medical research purpose, teaching communication and video documenting. Digital video recorder Supporting external USB storage device Supporting HDMI/YPbPr/HD-SDI/DVI-D/VGA input signal Default with camera control function Supporting video recording from other medical devices source

Send Message
product image
Laboratory Usage

We are the Leading Supplier of Abbe Refractometer Rajdhani. In the Abbe'' refractometer the liquid sample is sandwiched into a thin layer between an illuminating prism and a refracting prism. The refracting prism is made of a glass with a high refractive index (e.g., 1.75) and the refractometer is designed to be used with samples having a refractive index smaller than that of the refracting prism. A light source is projected through the illuminating prism, the bottom surface of which is ground (i.e., roughened like a ground-glass joint), so each point on this surface can be thought of as generating light rays traveling in all directions. A detector placed on the back side of the refracting prism would show a light and a dark region. Over a century after Abbe''s work, the usefulness and precision of refractometers has improved, although their principle of operation has changed very little. They are also possibly the easiest device to use for measuring the refractive index of solid samples, such as glass, plastics, and polymer films. Some modern Abbe refractometers use a digital display for measurement, eliminating the need for discerning between small graduations. However, the user still has to adjust the view to get a final reading. The first truly digital laboratory refractometers began appearing in the late 1970s and early 1980s, and no longer depended on the user''s eye to determine the reading. They still required the use of circulating water baths to control instrument and fluid temperature. They did, however, have the ability to electronically compensate for the temperature differences of many fluids where there is a known concentration-to-refractive-index conversion. Most digital laboratory refractometers, while much more accurate and versatile than their analog Abbe counterparts, are incapable of readings on solid samples. In the late 1990s, Abbe refractometers became available with the capability of measurements at wavelengths other than the standard 589 nanometers. These instruments use special filters to reach the desired wavelength, and can extend measurements well into the near infrared (though a special viewer is required to see the infrared rays). Multi-wavelength Abbe refractometers can be used to easily determine a sample''s Abbe number.

Send Message
product image
Laboratory Usage

Aided by a team of qualified and expert designers, we are involved in offering a wide gamut of Refractometer Manual. The offered product is appreciated among customers owing to its fine finish & optimum quality. This product is manufactured by our workforce utilizing excellent quality material and sophisticated techniques in accordance with the set quality standards. Our given product is accessible in assorted specifications as per the definite requirements of the customers. Features: Precisely designed Accurate testing Reliability ABBE Refractometers: Model NAR-1T LIQUID Range 1.3000 to 1.7000 with sugar scale 0-95% built in light fourth place by estimation 5 to 50ºC temperature Model NAR-2T for high temperature samples from 0 to 120ºC temperature Model NAR-3T for precision measurement of the fourth place 5-50ºC temperature Model NAR-4T for high refractive index measurement range 1.4700 to 1.8700 Abbe Refractometer Manual Model 2WAJ - R I- nD 1.3000 to 1.7000 & Sugar percentage (Brix) Product Details: Model 2WAJ-RI Application Industrial, Laboratory Display Digital Operation Manual Range 0-95%

Send Message
product image
Clinical Chemistry

As the workload and test menu increase, simultaneous management of multiple ELISA protocols can become challenging. The LisaXL has been designed with an open architecture to meet various laboratory needs, providing all the tools necessary for hands-free ELISA processing, increasing the reliability and reproducibility, improving throughput, and freeing the laboratory staff from repetitive steps. LisaXL allows running multiple parameters for over 250 samples in a single batch. Equipped with dual probes and dedicated workstations, drastically improve ELISA workflows. LisaXL is a complete walkway system that minimizes manual errors while improving the accuracy and turnaround time for critical tests. LisaXL provides the flexibility to build and run virtually any ELISA assays. Product Features: Lisa XL is a true walk-away system for any laboratory needs. High Throughput with 6 plates, can process up to 576 tests. A dynamic scheduler ensures optimized system usage and turnaround times by processing 6 plates and up to 12 assays in each plate Onboard flexibility with sample capacity up to 272 and 20 interchangeable racks for reagents and samples. Dual probe processing ensures speed and reliability. "Zero" carryover with high-quality disposable tips. Six individually controlled incubators and shakers with variable temperature, time, and speed settings. Efficient washing with super sweep mode ensures minimum residual volume, with up to 6 different wash buffers. Easy to use touchscreen graphic user interface Product Applications: ELISA Physical Specifications 1 Dimensions Length 1375 mm 55" Height 845 mm 33" Width 850 mm 33.5" Weight 195 kgs (Approx) Power Supply Voltage 100 - 240 Volts Frequency 50 / 60Hz Power consumption 700 W General Specifications Assay per plate Up to 12 Number of ELISA plates Up to 6 Sample capacity Up to 272 Sample / Reagent capacity Total 20 racks Single rack holds 16 sample / reagent tubes Double rack holds 6 x 60 ml reagent bottles (can be used interchangeably) Tip / Dilution box Total 11 locations of 96 capacity each (can be used interchangeably) Reader Specifications Reading Range 0.0 - 3.5 O.D Reading Channels 8 Filter wheel 8 positions 405 nm, 450 nm, 492 nm, 620 nm std* 578 nm and 700 nm optional + 2 open Light source Halogen Lamp Reading mode Single, Dual, ORR Reading time < 1 min (for single filter) Linearity Up to 3.0 O.D (450 nm) Washer Specifications Manifold configuration 16 needles - 8 aspiration & 8 dispensing Precision < 5 % at 300 μl Wash cycle Programmable Residual volume < 5 μl / well Soak time Programmable Washer buffer capacity 6 × 2.25 L Waste water container 1 × 20 L Incubator Specifications Number of incubators Up to 6 Temperature range RT + 5°C up to 50°C Temperature stability ± 1°C Incubation time Programmable Time to set temperature < 6 min Shaking 200 to 800 RPM Shaking Method Orbital Pipetting Specifications Number of probes 2 Tips 300 µl / 1000 µl, Auto / Manual selected Multi-dispensing (Reagent) Minimum volume 4 μl Serum dispensing time < 14 min Reagent dispensing time < 5 min Sample mixing Yes (Automatic) Precision Sample & Reagent Sample Dispensing with 300 µl tip: 3% above 10 µl ± 0.5 µl for 10 µl & less Reagent Dispensing with 300 µl tip: 3% for 25 µl & above Reagent Dispensing with 1ml tip: 5% for 75 µl & above" Process Security Liquid level sensing Well fill verification Clot detection Onboard sample identification Onboard reagent identification Strip verification Buffer sensing Alarms Software Operating System Windows 10 (Embedded) LIS interface Bi-directional, Serial / TCPIP USB Port Graphic load interface Graphical work list Data processing Quantitative, Semi-Quantitative & Qualitative Multi password access Ability to archive data Computer (Base configuration considered, higher configuration can be considered for upgrade after testing) Intel Core i3, 4 GB RAM, 1 TB hard disk Monitor 22" Full HD touch screen

Send Message
product image
Clinical Chemistry

EM 360 is a Fully Automated Clinical Chemistry Analyser which is time tested and proven technology. It is designed to provide the most demanding productivity, speed and operational ease. EM 360 with a throughput of 360 tests/hour offers flexibility in operation and rugged performance to win against high workload, tight deadlines, multiple tasks and complexity of testing. It yields high quality results for virtually any biochemistry test to deliver quick, efficient and consistent performance. Product Features: Automated, Discrete, Patient prioritized, Floor model Based on proven technology, Diffraction Grating Separate probes for Reagent R1 & R2 and dedicated probe for sample Low reading volume of 200 µl only Onboard cooling for reagents to enhance the reagent stability Barcode for reagents & samples (Optional) Wide test menu Product Applications: End Point Reactions: Glucose, Cholesterol, Triglycerides, Albumin, Total Protein, Uric Acid, Calcium, Magnesium, Bilirubin Total, Bilirubin Direct Kinetic Reactions: SGOT, SGPT, GGT, LDH, CK, CK MB, ALP, ACP, Amylase, Lipase Two Point Rate Reactions: Urea, Creatinine Immunoturbidimetric Chemistries: RA, CRP, ASO, Direct HDL, Direct LDL, Apo A, ApoB, Lp (a) Special Chemistries: HbA1c, Iron, Ferritin, Phosphorus, Microprotein, Ammonia, Bicarbonates System Type: Discrete, automated, random access, patient prioritized clinical chemistry analyzer Throughput: 360 tests / hour photometric and 600 tests / hour with ISE* (*optional ISE with Na+, K+, Cl-, Li+) Analytical Methods: 1-Point, 2-Point, Rate-A, Rate-B, Direct Potentiometry (optional) Barcode Reader: For reagents and samples (optional) Reaction Tray: 60 hard glass cuvettes Reaction Mixing: Stirrer with variable speed Minimum reaction Volume: 150 μl with maximum 200 μl reading volume On-board Laundry: 5 stage cleaning, 2 stage drying Photometer: Multi-wavelength diffraction grating with 12 wavelengths (340, 376, 415, 450, 480, 505, 546, 570, 600, 660, 700, 750 nm) OD Range: 0.0 - 3.0 Light Source: Halogen lamp Detector: Silicon photo-diode Water Consumption: < 10 litres Programmable Parameters: Default system pack parameters + upto 99 user defined parameters, Unlimited profile and unlimited calculation items Quality Control: QC plot data with QC rules. Provision for lab mean. Twin plot Calibration: K-Factor, Linear (1, 2 point & multipoint), 4P and 5P Logit-log, cubic spline, exponential, polynomial, On-board serial dilution for calibrator Power Requirement: AC 220 V ± 10 %, 50 Hz or AC 110 V ± 10 %, 60 Hz Power Consumption: 800 VA Dimension (mm): Approx. 675 (W) x 840 (D) x 1120 (H) Weight: Approx. 150 kgs. SAMPLE HANDLING Sample: Serum, Plasma, Urine, CSF, Whole blood, other Sample Unit: 82 positions for samples, blank , controls, calibrators, STAT sample Sample Pipetting: 2 - 70 µl (adjustable in 0.1 µl step) for Biochemistry, 70 µl fixed for ISE Capacitance probe with liquid level sensing & vertical obstruction detection, serum indices Auto Rerun: Repeat with same, increased or decreased volume ( upto 1:150) Sample Tubes /Cups: Primary tubes of 5 ml, 7 ml, 10 ml and sample cups REAGENT HANDLING Reagent Tray: 50 positions for reagents with onboard cooling Reagent Pipetting: R1: 50 - 300 µl (adjustable in 1 µl step) R2: 10 - 200 µl (adjustable in 1 µl step) Capacitance probe with level sensing & vertical obstruction detection SYSTEM INTERFACE: Analyzer-PC: USB PC - Host Computer: Bidirectional TCP / IP & RS - 232 PC - Printer: USB Operating System: Windows Based Database: Unlimited Results

Send Message
product image
Clinical Chemistry

Product Description: XL-640 with CRS is a random access, discrete, patient prioritized, fully automated clinical chemistry analyzer with autoloader designed to meet the needs of today’s modern clinical laboratories with high workload. Once samples are loaded, it is a complete walk-away system. XL 640 CRS is designed to operate smoothly over the long haul and to deliver consistent quality report. Product Features: Throughput of 400 tests/ hour (Photometric) and 640 tests/hour with ISE 56 Reagent Positions with On-board cooling for reagents 162 Sample positions with /Autoloader Separate probes for reagent R1 & R2 and dedicated probe for sample Clot detection for sample probe, Reflex testing and Serum Indices identification 72 permanent hard glass cuvettes with On-board Laundry Automatic dilution for high abnormal samples & Auto Rerun facility Extensive QC Programmes with Levy –Jennings Curve & QC rules. Automatic calculation for Mean SD & CV% Direct loading for primary tubes Touch screen User Friendly GUI with Bi-directional connectivity. System General System Type: Automated, Discrete, Random Access, Patient Prioritized Clinical Chemistry Analyzer with Autoloader Throughput: 400 photometric tests/hour & 640 tests/hour with ISE (*optional ISE with Na, K, Cl, Li) Analytical Methods: 1-Point, 2-Point, Rate-A, Rate-B, Direct Potentiometry(optional) Barcode Reader: Both for Samples & Reagents (Optional) Reactions Tray: 72 hard glass cuvettes Reaction Mixing: Dual Stirrer with variable speed Reading Volume: 180 µl On-Board Laundry: 6 stage cleaning, 2 stage drying Photometer: Multi-wavelength diffraction grating with 12 wavelengths (340, 376, 415, 450, 480, 505, 546, 570, 600, 660, 700 & 750 nm) O.D. Range: 0 - 3.0 Light Source: Halogen Lamp Detector: Silicon Photodiodes Water Consumption: < 14 liters/hour Programmable Parameters: Default system pack parameters + upto 99 user defined parameters, Unlimited profiles and unlimited calculation items Quality Control: Q.C. plot data with Q.C. Rules. Provision for lab mean. Twin plot. Caliberation: K- factor, Linear (1,2 point and multipoint) 4P and 5P Logit-log, Cubic spline,exponential, polynomial. On-board serial dilution for calibrator Power Requirement: AC 220 V ± 10 %, 50 Hz or AC 110 V ± 10 %, 60 Hz Power Consumption: 800 VA Dimensions: Approximately 897 mm (w) x 655 mm (D) x 1170 mm (H) Weight: Approximately 200 Kg Sample Handling Sample: Serum, Plasma, Urine, CSF, Whole blood, other Sample Unit: upto 162 positions for samples/STAT/calibrator/controls with Autoloader Sample Pipetting: 2-70 µl (adjustable in 0.1 µl steps) for biochemistry,70 µl fixed for ISE capacitance probe with liquid level sensing and vertical obstruction detection , clot detection and serum indices and Reflex Testing Auto Rerun: Repeat with same, increade and decresaed volume (upto 1:150) Sample Tubes/Cups: Primary tubes of 5 ml, 7ml and 10 ml and sample cups Reagent Handling Reagent Tray: 56 positions for reagents with on-board cooling Reagent Pipetting: R1: 60 - 300 µl (Adjustable in 1 µl step) R2: 0 or 10 - 300 l (Adjustable in 1 µl step) Capacitance probe with level sensing and vertical obstruction detection System Interface Analyzer-PC: USB PC- HOST Computer: Bidirectional TCP/IP and RS - 232 PC- Printer: USB Operating System: Windows based with Touch Screen User Friendly GUI Database: Unlimited Results

Send Message
product image
Biochemistry Analyzer

Overview A fully automated POC Auto Dry Biochemistry Analyzer called Mispa Chem Dx, With Just 3 to 4 drops (100ul) of whole blood to test up to 19 General and Special chemistry tests in less than 12 minutes. Mispa Chem Dx works on absorption spectroscopy where a change in absorbance is detected by an absorption spectrum and an algorithm is used to calculate the end concentration of the sample in the reagent dry disc. The reagent disc consists of lyophilized reagent beads, diluent, and calibration details in the QR code. The reagent disc contains an intelligent internal quality control system IQC which continuously monitors the disc function to ensure reaction stability and optimal disc performance, IQC is the engine that drives the Mispa Chem Dx accurately and precisely Low Sample Consumption Easy to Use Maintenance Free Accurate Result Disposable reagent disc Sample volume: 100µl Testing time: 12 minutes / sample Temperature: 37°C ± 0.3°C Resolution: 0.001Abs Absorbance: 0-3.0Abs Sample type: Heparinized whole blood, serum, plasma (heparin) QC&Calibration: IQC (Intelligent Quality Control/Calibration) Work condition: Temperature:10-30°C Humidity: 30%-70% Testing method: End point, kinetic, fixed time, turbidmetry etc Light source: 12V/20W, Halogen tungsten lamp with life span over 2500 hours Power supply: AC 100V-240V, 50-60Hz Display: Android 7.0 inch 800*480, multi-point capacitive touch screen Storage: 500,000 results Printer: Built-in thermal printer Interface: 4 USB ports, 1 LAN port Dimension: 315*375*475mm. 4.2kg(N.W.), 7kg(G.W.)

Send Message

Still searching for
70 baume light liquid hydrometers?