Jaipur
+918529833535

'6 mm optical path'

Items tagged with '6 mm optical path'

product image
Hematology

BC-6800 Today, laboratories not only need more reliable routine CBC plus 5-part diff WBC testing by way of high processing speed, but are also looking for options that extend the analyzer's output in form of Reticulocytes, Nucleated RBCs, Fluorescent Platelet counts etc. for wider clinical application and research. On the other hand, they are restricted by limited budgets. BC-6800 can help to meet all these needs just perfectly and even exceed the expectations. Additional parameters for further clinical applications IMG(#,%) parameters provide information about immature granulocyte, including promyelocytes, myelocytes and metamyelocytes. HFC*(#,%) parameters represent high fluorescent cell population, such as blasts and atypical lymphocytes. RET(#,%) extend valuable help in the differential diagnosis and/or therapeutic monitoring of anemias. IRF is parameter concerning immature reticulocytes, which can assist in early diagnosis of anemia and monitoring the bone marrow response to therapy. InR*(#,‰) are parameters regarding infected red blood cell. The red blood cells may infected by plasmodium, which can cause malaria. * means research parameters SF Cube Technology SF Cube is a pathbreaking technology for reliable blood cell analysis, including WBC differential, Reticulocytes and NRBC with efficient flagging. After reaction with proprietory reagents, the targeted blood cells undergo 3D analysis using information from scatter of laser light at two angles and fluorescence signals. The 3D scattergram builds the power to better identify and differentiate blood cell populations, especially to reveal abnormal cell population undetected by other techniques. Minimizing interference to ensure more accurate results NRBCs are counted in a dedicated channel by SF cube method, which automatically corrects total WBC count and 5-part Diff results when NRBCs are detected. The Focusing Flow-DC method minimizes the interference traditionally encountered in DC technology to produce near gaussian histograms. PLT-O result avoids the interference from microcytic and fragmented RBCs, large platelets and/or platelet clumps by fluorescent stain, and enhances the results accuracy and sensitivity. High automation to minimize the workload Throughput for 125 tests/hour, autoloader for 100 sample tubes capacity Bi-directional LIS with HL7 or ASTM communication protocol Customizable re-exam rules allow users to define their re-exam criterion according to lab’s practice

Send Message
product image
Hematology

The advanced BC-6800Plus not only provides more reliable routine CBC plus 5-part DIFF results, but also has a higher throughput of up to 200 samples per hour. Based on the new SF Cube technology platform, the BC-6800Plus could provide more reliable blood cell results and abnormal cells flagging results with anticipated warning messages, exceeding clinicians’ expectations and setting a new standard for blood analysis. SF Cube Technology With the newly designed opticals and reagent systems, the SF Cube technology can help doctors to better differentiate the clusters of cells, which is the key to revealing more abnormal cells. NRBC result in every CBC In WNB scattergram, BC-6800Plus provides NRBC, Basophils and WBC-N* results. It means that the actual number of NRBCs can be measured in routine CBC, if they are present in the sample. Basophils are counted in this counting channel with NRBC results. Basophil and NRBC results are generated on BC-6800Plus without extra reagent or cost. NLR parameter in each CBC+DIFF Neutrophil-to-lymphocyte ratio (NLR) is calculated by dividing neutrophil count by lymphocyte count, usually from peripheral blood sample. In laboratory medicine, NLR is used as a marker of subclinical inflammation. According to clinical studies, NLR can be used as a prognostic factor of severe illness in COVID-19 patients. More accurate RET and PLT-O result By utilizing the new fluorescent dye, the reticulocytes and platelets are more specific stained with stronger fluorescent signal, that brings more reliable reticulocyte and platelet results. Automatic Rerun & Reflex Should the sample results trigger the criteria, the sample rack can automatically step back for a “rerun” or “reflex” check. 200 test/hour BC-6800Plus can load up to 100 samples at a time and offers a throughput of up to 200 tests per hour.

Send Message
product image
Clinical Chemistry

The SAL 6000 modular system delivers fast throughput and powerful integration across immunoassay and chemistry systems. Broad assays can be tested with one sample tube, which can maximize operation efficiency and increase lab productivity. Product Description SAL 6000 Modular System delivers fast throughput and seamless integration of CL-2000i Chemiluminescence Immunoassay System and BS-800 Modular System. In conjunction with the SPL 1000 Sample Processing System, this scalable platform not only provides optimized workflow, it also offers satisfactory operator experience. Features · Seamless integration, workflow optimization · Uniform software interface, easy of operation · One tube sampling, flexible to test · Technology and quality heritage · Flexible scalability, on-site upgrading · Comprehensive test menu Product Specification Automation Fully Automatic Brand Mindray Model Name/Number SAL 6000 Assays Clinical Chemistry Power Supply 220 V Usage/Application Hospital Frequency 50 Hz

Send Message
product image
Laboratory Usage

Using best-in-class technology, the Mindray CL-6000i is a chemiluminescence immunoassay analyzer with high throughput, high performance and high reliability. Features Throughput: up to 480 tests per hour Measurement principle: enhanced ALP-AMPPD method Reagent carousel: 36 reagent positions with non-stop refrigerating Sample handling: up to 300 samples can be loaded in one batch, sample loading and offloading continuously by sample racks, fast prioritizing STAT samples Sample volume: 5-110 μL Continuously loading of reagents, substrate, cuvettes, wash buffer and waste bags Zero daily maintenance Product Specification Model Name/Number CL-6000i Usage/Application Hospital Brand Mindray Sample Volume Range 5-110 microlitre Throughput up to 480 tests per hour Measurement Principle enhanced ALP-AMPPD method Reagent Carousel 36 reagent positions with non-stop refrigerating Sample Handling up to 300 samples can be loaded in one batch,sample loading and offloading continuously by sample r

Send Message
product image
Clinical Chemistry

Find the Best Semi Automatic Biochemistry Analyzer from Accurex. Buy Acculab At 112 Plus (Semi Auto Biochemistry Analyzer) which is the best Biochemistry Machine with numerous features like Filter Check, Self-check operation for optical filters, Checks the absorbance of each of the 7 filters & free position, Ensures that all the filters are in good working condition. This Biochemistry Analyzer has Improved ergonomic touch screen display, ensures strain free viewing with End point, kinetic, fixed time & absorbance mode. FILTER CHECK • Self-check operation for optical filters. • Checks the absorbance of each of the 7 filters & free position. • Ensures that all the filters are in good working condition. WORKLIST • A unique facility by which a worklist can be prepared for every sample ID. • Printouts can be taken by sample ID or test parameters. • Print by ID : Ensures that no test is left out for a particular ID. • Print by Test : Ensures that all reagents / working solutions are prepared in correct volumes preventing wastage. • The system flags any test which is missed out for a particular ID, ensuring all assay panel is completed. LAMP SAVING • Lamp saving option available ensuring long lamp life. • The lamp can be turned off in case of sporadic sample workload ALARMS • Audio alarm is sounded when results are higher (S) or lower (L) than reference range ensuring that all abnormal samples are flagged for further review. • Improved ergonomic touch screen display, ensures strain free viewing • End point, kinetic, fixed time & absorbance mode • Single & bichromatic measurement • Memory : 3200 results • 112 programmable channels • Calibration modes – 1 standard / multi-point linear / multi-point non-linear • Easy-access maintenance chamber ensures efficient uptime management • Real-time reaction curve display • Anti-vibration & anti-disturbance optical system ensures highly accurate results • Option of 7 filters (340 – 630 nm) & 1 free position • Comprehensive quality control program with L-J graph • Lamp saving feature to prolong lamp life • Audible / visual alarm available • Easy-tear printer design Methodology: End point, kinetic, fixed time & absorbance Calibration: Single standard/multi-point linear/multi-point non-linear Programmable channels: 112 Memory: 3200 results Quality control: Comprehensive QC software with L-J graph Light source:Quartz-Halogen lamp 12V / 20W Photometric range: 0.0000 to 3.0000 Abs, Resolution : 0.0001 Abs : Drift : 0.002 Abs/hour Wavelength range: 7 standard filters: 340, 405, 492, 510, 546, 578, 630 nm & 1 free optional position ; Half Bandwidth < 8 nm : Stray light : < 1.0 % at 340 nm, Stainless steel body with quartz window; Optical path 10 mm Flowcell: Stainless steel body with quartz window; Optical path 10 mm Measuring volume: 32 μl Programmable aspiration volume:: 500-2000 μl Temperature control: Peltier elements : 25°C, 30°C & 37°C ±0.1°C Input: Ergonomic LCD touch screen display Printer: Built-in high speed thermal printer Interface: RS-232 serial port Dimension / Weight: 450 x 360 x 140 mm / 11.5 kgs Operating environment: Temperature: 15-30°C ; Humidity: 20-80 % Power requirement: AC 110-220 V ±10%, 50/60 Hz Safety Information • The position of the LCD display has been designed to reduce cervical (neck muscle) strain during continual use. • The aerial view display design makes it possible to view the screen from multiple perspectives, (standing or sitting, with equal clarity). Direction for Use • A unique facility by which a worklist can be prepared for every sample ID. • Printouts can be taken by sample ID or test parameters. • Print by ID : Ensures that no test is left out for a particular ID. • Print by Test : Ensures that all reagents / working solutions are prepared in correct volumes preventing wastage. • The system flags any test which is missed out for a particular ID, ensuring all assay panel is completed. Other Info • Improved ergonomic touch screen display, ensures strain free viewing • End point, kinetic, fixed time & absorbance mode • Single & bichromatic measurement • Memory : 3200 results • 112 programmable channels • Calibration modes – 1 standard / multi-point linear / multi-point non-linear • Easy-access maintenance chamber ensures efficient uptime management • Real-time reaction curve display • Anti-vibration & anti-disturbance optical system ensures highly accurate results • Option of 7 filters (340 – 630 nm) & 1 free position • Comprehensive quality control program with L-J graph • Lamp saving feature to prolong lamp life • Audible / visual alarm available • Easy-tear printer design

Send Message
product image
Clinical Chemistry

Product Specification Model Name/Number HumaStar 200 Brand Human Automation Fully Automatic Display Digital Dimensions 69 x 76 x 52 cm (WxDxH) Frequency 50/60 Hz Voltage 220-240 or 110-120 Vac Temperature 16-30 Degree C Throughput Up to 200 t/h throughput Weight 51 kg Reaction volume 210-350 il Wash station 6 dispensing needles Water consumption < 2 l/h (8 ml/test) Languages English, French, Spanish Software (other languages can be added) Humidity < 80 % non-condensing Data External computer required (Pentium IV, 2 GHz Mode Open, random-access, STAT Product Description Product Detail : Unique Random-Access Analyzers for Small to Medium Size Laboratories Unique design Unique software architecture Unique features Analysis Endpoint (bichromatic), Differential endpoint (with sample blank), Fixed time, Kinetic (bichromatic) Multi-standard (up to 8), factor, linear, non linear (cubic-spline, poly-linear and logit-log four parameters) Samples Removable sample tray 60 positions: primary tubes 12–12.5x100 mm and 10 mm cups Optional: sample tray for 20 primary tubes 12–16x100 mm and 20 cups 3.5 ml Sample volume: 2–300 µl Internal barcode reader Automatic pre- and post-dilution Test profiles and replicates Reagents Removable reagent tray 30 reagent / diluent positions 50 and 20 ml bottles, adapter for tubes and cups Reagent volumes: 5–350 µl Refrigeration to ~9 Degree C below ambient (at bottom of bottle) Substrates, Enzymatic, Turbidimetric Reaction Reaction volume: 210–350 µl 80 reusable Bionex® cuvettes 6 mm optical path Heat transfer by air Pipetting Needle shock detector Capacitive liquid level detector Wash station 8-step cuvette wash station Systemic and special washing solution HumaStar 200: 6 dispensing needles Water consumption < 2 l/h (8 ml/test) Optical system 9 discrete wavelengths (340, 405, 505, 546, 578, 600, 650, 700 nm, one free position) Band pass: +/– 5 nm Photometric linearity: 0–2.5 Abs Stability: <1 % drift per day Management 20 GB HDD, 512 MB RAM, CD/R, USB) Windows 7® with .NET framework 4.0 English, French, Spanish OS recommended Core i3TM or dedicated graphic card recommended Minimum 900 dots resolution Designed for touch screen (1280x1024 pixel) LIS: Bi-directional, polling mode, ASTM, ethernet Printouts By patient, single test, complete sample, work sheet, method and QCs, calibration curves, kinetics, continuous printing

Send Message
product image
Hemostasis Analyzer

ECL 760 ECL 760 is an advanced Fully automated coagulation analyzer with seven detection channels providing operators with a compact easy-to-use system. Dedicated for mid-volume throughput labs, the ECL 760 been designed to optimize your productivity. ECL 760 is a blend of modernity and simplicity. Erba reagents oers a wide menu of test parameters for automated coagulation analyzers. KEY FEATURES ECL 760 uses the proven system of percentage intensity of light scatter at 640 nm LED. This optical system ensures early light stability, longer duration usage time and greater lamp life. It minimizes the interference of hemolysis, ictericity and lipemia, in samples at each assay, The system monitors the entire clotting process from reagent addition to complete clot formation with the generation of Clot curve. Clotting Tests  All clotting tests, such as Prothrombin Time, Activated Partial Thromboplastin Time, Fibrinogen, Thrombin time, Factors (II / V / Vll / X / Vlll / IX\ Xl / Xll), Lupus and Protein S are performed. Chromogenic Tests  Chromogenic tests use the colorimetric principle of measuring absorbance of light (405nm LED) by the test in a cuvette. Protein C and Antithrombin Illare some of the tests done by this method. Immunological Assay  The change in light intensity caused by the antigen antibody reaction is detected at 575 nm LED, as the change in the transmitted light.  D Dimer is the most common test performed

Send Message

Still searching for
6 mm optical path?